15888-200 bits golf course - key plan a 15888-200-1 bits
TRANSCRIPT
220
222
223
221
201 202
203 204
206 207
210
208
205
209 211
212
MALPAS ST
JACAR
AND
A DR
2
1
PG
NY
3
4
5
6
PRO
7
8
9
10
DAM
DAM
PS
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
FUTURE HOLESTAKE OFF POINT
MAIN PIPE & CABLE PIT
FUTURE HOLESTAKE OFF POINT
MAIN PIPE & CABLE PIT
FUTURE HOLESTAKE OFF POINT
MAIN PIPE & CABLE PIT
11
FUTURE HOLESTAKE OFF POINT
MAIN PIPE & CABLE PIT
T11
12
T12
13
CG
T13
DAM
FUTURE HOLESTAKE OFF POINT
MAIN PIPE & CABLE PIT
CLIENT:
PROJECT:
SHEET OFDRAWING No. REVISION
DES/DRAWN:
APPROVED:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
This document is and shall remain the property ofHYDRO-PLAN PTY. LTD. The document may onlybe used for the purpose for which it wascommissioned and in accordance with the terms ofengagement for the commission.
The arrangement and general details as shown onthis drawing are essentially diagrammatic and mustbe applied to the circumstances as found on site.
COPYRIGHT
SmartApprovedWaterMark
DRAFT REF:
CHECKED:
NORTH
Dra
win
g fil
e: D
:\Wat
erEt
\DW
G C
AD\H
P te
mp\
1588
BIT
S D
ENN
IS P
ARK
(tem
p D
dve
)\H
P up
d ge
o R
1\15
888-
200-
d2 -
Stan
dard
\158
88-2
00-B
ITS
GO
LF_I
RR
IGAT
ION
(d2)
.dw
g - 0
5/08
/202
1 8:
19 P
M O
rigin
al S
ize:
ISO
FU
LL B
LEED
A3
(420
.00
X 29
7.00
MM
)
DATE:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
http://hydroplan.com.au
SYDNEYADELAIDEPERTH BEIJINGBRISBANEMELBOURNEA 30/07/2021 EM SJ CONCEPTS - FOR COMMENT & APPROVAL
GLADESTONE REGIONAL COUNCIL182-21 BITS CLUB SITE & DENNIS PARK SPORTS COMPLEX
DETAILED DESIGN IRRIGATION SYSTEM
EM
PH
SJ
12/05/2021
4-GRC-d2 18 A
BITS GOLF COURSE - KEY PLAN
15888-200 1
SCALE 1: ORIGINAL SIZE
-5 0 5 10 15 20 25 50m
500 A1
DRAWING TABLEDRAWING NUMBER TITLE REV
15888-200 BITS GOLF COURSE - KEY PLAN A15888-200-1 BITS GOLF COURSE - ROTOR PERFORMANCE DATA A15888-201 BITS GOLF COURSE - LAYOUT 1 A
15888-202 BITS GOLF COURSE - LAYOUT 2 A
15888-203 BITS GOLF COURSE - LAYOUT 3 A
15888-204 BITS GOLF COURSE - LAYOUT 4 A
15888-205 BITS GOLF COURSE - LAYOUT 5 A
15888-206 BITS GOLF COURSE - LAYOUT 6 A
15888-207 BITS GOLF COURSE - LAYOUT 7 A
15888-208 BITS GOLF COURSE - LAYOUT 8 A
15888-209 BITS GOLF COURSE - LAYOUT 9 A
15888-210 BITS GOLF COURSE - LAYOUT 10 A
15888-211 BITS GOLF COURSE - LAYOUT 11 A
15888-212 BITS GOLF COURSE - LAYOUT 12 A
15888-220 BITS GOLF COURSE WATER SUPPLY - LAYOUT 1 A
15888-221 BITS GOLF COURSE WATER SUPPLY - LAYOUT 2 A
15888-222 BITS GOLF COURSE WATER SUPPLY - LAYOUT 3 A
15888-223 BITS GOLF COURSE WATER SUPPLY - LAYOUT 4 A
IRR OPTIONS 1&22X OEM ROTOR PERFORMANCE
CONCEPTSFOR COMMENT & APPROVAL
KEY DESIGN DATA - CONCEPT STAGEBITS GOLF CLUB
GOLF COURSE - CURRENT 13 HOLESCURENT AREA (13 HOLES) 11.4 HASOIL, TYPICAL LOAMPLANT SPORTS TURF - HIGH USEPLANT FACTOR 0.8 (OPTIMUM GROWTH)WINDOW 7.00PM TO 4.00AMIRRIGATION TIME 9 HR/DAYPEAK DEMAND 34 MM/WKPUMP DUTY CAPACITY Q= 22 (30^) l/S @ H=70MROTOR GROUPING RANGE: UP TO 15 X ROTORSEXISTING PS POWER 22KW (40 FLA @ 415V) FIXED - GOLFNEW PUMP POWER 33KW^ (60 FLA @ 415V) VFD - GOLFPEAK VOLUME, WEEK 3.9 ML/WKAVERAGE VOLUME, YEAR 66 ML/YRASSUMES YEAR ROUND USAGE & IRRIGATION PROGRAM
ESTIMATES FOR FUTURE GOLF DEMAND - 18 HOLES^AREA 15.8PUMP FUTURE CAPACITY Q= 30 L/S @ H= 70MPEAK VOLUME, WEEK 5.4 ML/WKAVERAGE VOLUME, YEAR 92 ML/YR
POWER SUPPLY - EXISTING BITS PUMPSPOWER/LOAD - GOLF 22KW / 40FLA @ 415POWER/LOAD - SPORTS 22KW / 40FLA @ 415POWER / LOAD - GOLF + SPORTS 44KW / 80FLA @ 415V
POWER SUPPLY - NEW BITS PUMPSINCLUDES FUTURE CAPACITYPOWER/LOAD - GOLF 13 HOLES 22KW / 40FLA @ 415V POWER/LOAD - GOLF 18 HOLES 33KW / 40FLA @ 415VPOWER/LOAD - SPORTS 11KW / 40FLA @ 415VPOWER / LOAD - GOLF + SPORTS 44KW / 80FLA @ 415V
KEY DESIGN DATA - CONCEPT STAGE - RW SUPPLY ALL SITESBITS SPORTS CLUBS, BITS GOLF & DENNIS PARK RL
ALL SITES ESTIMATED DEMAND SUMMARY *AREA, TOTAL SITES 19.43 HAFLOW PEAK DEMAND 42 L/SVOLUME, PEAK WEEK 6.65 ML/WKAVERAGE VOLUME, YEAR 112 ML/YR
CURRENT RECYCLED WATER SUPPLY CAPACITY ^FLOW, IN/OUT BITS TANKS 30 TO 35 L/SFLOW, IN/OUT DENNIS PARK TANKS 13 L/SCOMBINED FLOW, IN/OUT BITS & DP 43 L/SPEAK VOLUME, WEEK ## ML/WK (GRC-TBC)AVERAGE VOLUME, YEAR 119 ML/YR (GRC-IMP)
NOTES:A. (*) BASED ON AVERAGE BOM DATA, CURRENT SITE AREAS INCLUDE PROPOSED SPORTS FIELD EXTENSIONS
WHERE SHOWN ON DRAWINGS. DOES NOT INCLUDE POTENTIAL FUTURE 5 GOLF HOLES, WHICH WOULDINCREASE GOLF PUMP STATION FLOW FROM 22 L/S TO 30 L/S AND TOTAL FLOW DEMAND TO 50 L/S.
C. (^) BITS TANK IS LIMITED TO 30 L/S WHEN DENNIS PARK IS OPERATING AT THE SAME TIME (8.30PM TO 3AM).GRC WATER OPERATORS ADVISED DENNIS PARK USAGE TIMES ARE SIGNIFICANTLY LOWER THAN BITS,PERHAPS RELATED TO SEASONAL FIELD USAGE, WHICH MAY OFFER SOME ALLOCATION FLEXIBILITY. GOLFHOURS 7PM-4AM.
D. (^) IF GOLF COURSE AREAS ARE SIGNIFICANTLY EXTENDED (EG, 5 HOLES ~ 4.4 HA) IN THE FUTURE THE STPCAPACITY, INCLUDING VOLUME, PUMP/PIPE SIZE, TANKS AND IN FLOWS WILL REQUIRE REVIEW AS THEESTIMATED GOLF DEMAND WILL INCREASE PROPORTIONALLY BY 38% AND THE SYSTEM DESIGN IS AT ORNEAR CAPACITY WITHIN THE AVAILABLE TIME WINDOWS, BASED ON THE INFORMATION PROVIDED BY GRCTO DATE.
E. GRC TO CONFIRM RW SUPPLY CAPACITY TO BITS/DENNIS PARK, STP MAY HAVE ALLOCATION SUPPLYOTHER SITES, EG - RED MUD DAM DURING DAY TIME HOURS
220
222
223
221
201 202
203 204
206 207
210
208
205
209 211
212
MALPAS ST
JACAR
AND
A DR
2
1
PG
NY
3
4
5
6
PRO
7
8
9
10
DAM
DAM
PS
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
FUTURE HOLESTAKE OFF POINT
MAIN PIPE & CABLE PIT
FUTURE HOLESTAKE OFF POINT
MAIN PIPE & CABLE PIT
FUTURE HOLESTAKE OFF POINT
MAIN PIPE & CABLE PIT
11
FUTURE HOLESTAKE OFF POINT
MAIN PIPE & CABLE PIT
T11
12
T12
13
CG
T13
DAM
FUTURE HOLESTAKE OFF POINT
MAIN PIPE & CABLE PIT
CLIENT:
PROJECT:
SHEET OFDRAWING No. REVISION
DES/DRAWN:
APPROVED:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
A 30/07/2021 EM SJ CONCEPTS - FOR COMMENT & APPROVAL
GLADESTONE REGIONAL COUNCIL182-21 BITS CLUB SITE & DENNIS PARK SPORTS COMPLEX
DETAILED DESIGN IRRIGATION SYSTEM
EM
PH
SJ
12/05/2021
4-GRC-d2 18 A
BITS GOLF COURSE - ROTOR PERFORMANCE DATA
15888-200-1 2
SCALE 1: ORIGINAL SIZE
-5 0 5 10 15 20 25 50m
500 A1
IRR OPTIONS 1&22X OEM ROTOR PERFORMANCE
CONCEPTSFOR COMMENT & APPROVAL
This document is and shall remain the property ofHYDRO-PLAN PTY. LTD. The document may onlybe used for the purpose for which it wascommissioned and in accordance with the terms ofengagement for the commission.
The arrangement and general details as shown onthis drawing are essentially diagrammatic and mustbe applied to the circumstances as found on site.
COPYRIGHT
SmartApprovedWaterMark
DRAFT REF:
CHECKED:
NORTH
Dra
win
g fil
e: D
:\Wat
erEt
\DW
G C
AD\H
P te
mp\
1588
BIT
S D
ENN
IS P
ARK
(tem
p D
dve
)\H
P up
d ge
o R
1\15
888-
200-
d2 -
Stan
dard
\158
88-2
00-B
ITS
GO
LF_I
RR
IGAT
ION
(d2)
.dw
g - 0
5/08
/202
1 8:
19 P
M O
rigin
al S
ize:
ISO
FU
LL B
LEED
A3
(420
.00
X 29
7.00
MM
)
DATE:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
http://hydroplan.com.au
SYDNEYADELAIDEPERTH BEIJINGBRISBANEMELBOURNE
DESIGN NOTESSCHEDULING COEFFICIENT - PERFORMANCE OPTIONS:DESIGN SPACING AND PATTERNS ARE MOSTLY DICTATEDBY SHAPES AND OBSTACLES TO DETERMINE THE LAYOUTTHAT BEST SUITS THE SITE, THEN A PRESSURE ISSELECTED FOR THE RESULTANT LAYOUT TO PROVIDE THEOPTIMUM PERFORMANCE IN TERMS OF DISTRIBUTIONUNIFORMITY (%), COEFFICIENT OF UNIFORMITY -CHRISTIANSEN (%) AND SCHEDULING COEFFICIENT. THEPERFORMANCE IS LARGELY RELIANT ON THE PRODUCTSAVAILABLE TO MEET CRITERIA, AND THERE IS NO VALUE INA SUBSTANDARD HYDRAULIC DESIGN AND STOCK LILACPIPE IS GENERALLY LIMITED TO PN12.5. IN THIS CASE TWOMANUFACTURERS WITH THE BEST PERFORMANCE DATA TOCOMPARE HAVE BEEN SELECTED ACROSS THE RANGE OFSPACINGS BEING USED IN THE DESIGN. BOTH OPTIONSHAVE A HIGH LEVEL UNIFORMITY AND VERY GOODSCHEDULING COEFFICIENT, AND EITHER CAN BERECOMMENDED ON THIS BASIS. ROTOR COSTS WILL NOT BESIGNIFICANTLY DIFFERENT IN THE SCALE OF PROJECT.OTHER KEY PERFORMANCE INDICATORS MAY BECONSIDERED OF VALUE, SUCH AS; PRESSURE, FLOW RATES& PRECIPITATION RATES - IN WHICH CASE OPTION 1 HASSEVERAL ADVANTAGES WITH LOWER OPERATINGPRESSURE, FLOWS & PRECIPITATION RATES WHILSTOFFERING THE SAME SCHEDULING COEFFICIENT INMAJORITY OF SPACINGS. OTHER FACTORS TO CONSIDERFOR SELECTING ROTOR OPTIONS INCLUDE THE CONTROLSYSTEM CAPABILITY, AS VALVE IN HEAD TYPE GOLFROTORS ARE INTEGRAL WITH THE MANUFACTURERSCONTROL SYSTEM & SOFTWARE.
CONTROL SYSTEM OPTIONS - OVERVIEW:BOTH SYSTEMS ARE INTEGRAL WITH THE MANUFACTURERSROTORS AND HAVE THE CAPABILITY FOR REQUIREDPROGRAMMING WITH MAPS & SENSOR INPUTS SUCH ASFLOW METERS AND ENVIRONMENTAL SENSORS FORADVANCED FLOW MANAGEMENT AND SEASONALSCHEDULING.
OPTION 1 - TOROCENTRAL CONTROL SOFTWARE - LYNX W/ MOBILE APP/NSNINTERFACE HARDWARE, I/O - SMART MODULE FOR ROTORSWITH SMART HUB FOR PUMP STN & FLOW METER CONNECT.2 WIRE (2.5MM²) CONTROL SYSTEM & GROUNDINGOPTION 2 - RAIN BIRDCENTRAL CONTROL SOFTWARE-STRATUS II C/W MI APP/GSPINTERFACE HARDWARE, I/O - IC-OUT FOR ROTORS WITHIC-IN FOR PUMP STN & FM CONNECT.2 WIRE (2.5MM²) CONTROL SYSTEM & GROUNDING
RECOMMENDATIONIN THE EARLY STAGES OF DETAILED DESIGN, OPERATORSRECEIVE A INTERACTIVE DEMONSTRATION OF THECENTRAL CONTROL SOFTWARE FROM EACHMANUFACTURER OF THE NOMINATED OPTIONS TO ACCESS.SUGGESTED AGENDA 1 HOUR FOR HARDWARE & 1 HOURFOR SOFTWARE EVALUATION OF EACH OEM CONTROLS.ALTERNATIVELY HYDROPLAN CAN PROVIDE A BRIEFEVALUATION OF THE TWO OPTIONS.
DESIGN NOTESCORECARD DATA TO BE CONFIRMED INDETAILED DESIGN WITH INPUT FROMBITS GOLF CLUB FOR EXISTING &FUTURE IRRIGATED AREAS
OPTION 2 - RAIN BIRDMODEL 702 & 752 (IC-NP)
OPTION 1 - TOROMODEL INF34 - SM (E)
REF
ER T
O D
WG
158
88-2
01
REF
ER T
O D
WG
158
88-2
02
REFER TO DWG 15888-201
REFER TO DWG 15888-203 REFER TO DWG 15888-203
REFER TO DWG 15888-202
REF
ER T
O D
WG
158
88-2
01
REF
ER T
O D
WG
158
88-2
02
T2
FUTURE HOLESTAKE OFF POINT
MAIN PIPE & CABLE PIT
11
T12
FUTURE HOLESTAKE OFF POINT
MAIN PIPE & CABLE PIT
CLIENT:
PROJECT:
SHEET OFDRAWING No. REVISION
DES/DRAWN:
APPROVED:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
This document is and shall remain the property ofHYDRO-PLAN PTY. LTD. The document may onlybe used for the purpose for which it wascommissioned and in accordance with the terms ofengagement for the commission.
The arrangement and general details as shown onthis drawing are essentially diagrammatic and mustbe applied to the circumstances as found on site.
COPYRIGHT
SmartApprovedWaterMark
DRAFT REF:
CHECKED:
NORTH
Dra
win
g fil
e: D
:\Wat
erEt
\DW
G C
AD\H
P te
mp\
1588
BIT
S D
ENN
IS P
ARK
(tem
p D
dve
)\H
P up
d ge
o R
1\15
888-
200-
d2 -
Stan
dard
\158
88-2
00-B
ITS
GO
LF_I
RR
IGAT
ION
(d2)
.dw
g - 0
5/08
/202
1 8:
19 P
M O
rigin
al S
ize:
ISO
FU
LL B
LEED
A3
(420
.00
X 29
7.00
MM
)
DATE:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
http://hydroplan.com.au
SYDNEYADELAIDEPERTH BEIJINGBRISBANEMELBOURNE
GLADESTONE REGIONAL COUNCIL182-21 BITS CLUB SITE & DENNIS PARK SPORTS COMPLEX
DETAILED DESIGN IRRIGATION SYSTEM
EM
PH
SJ
12/05/2021
4-GRC-d2 18 A
BITS GOLF COURSE - LAYOUT 1
15888-201 3
SCALE 1: SIZE A3SCALE 1: ORIGINAL SIZE
-4 0 4 8 12 16 20 40m
400 A1 800
IRR OPTIONS 1&22X OEM ROTOR PERFORMANCE
CONCEPTSFOR COMMENT & APPROVAL
LEGEND:
DN### HDPE PN12.5 LILAC MAIN PIPE - A
DN### HDPE PN12.5 LILAC LAT PIPE - A* (CONCEPT)
CONTROL WIRE ROUTE B, ## (NOT SHOWN) CONTROL WIRE ROUTE A, ## (NOT SHOWN)
PUMP: TYPE/SIZE ####
IRRIGATION CONTROLLER, TYPE ####
ISOLATION VALVE (DN## LINE SIZE) C/W 910 VB
DN50 AIR VALVE C/W 910VB (NOT SHOWN DN25 QCV C/W 910VB (NOT SHOWN)
BACKFLOW ASSEMBLY, TYPE/SIZE ####
WEATHER SENSOR, TYPE ####
DN## SOLENOID VALVE , TYPE ####
FILTER AUTO SCREEN, DN###, 200 MICRON
DN25/32 ROTOR A C/W SJR, MODEL ### FULL CIRCLE
DN### HDPE PN12.5 LILAC MAIN PIPE - B* (CONCEPT)
FLOW METER, TYPE/SIZE ####
LOW LEVEL SENSOR (NOT SHOWN)
DN## SOLENOID VALVE , TYPE #### * (CONCEPT)
DN25/32 ROTOR B C/W SJR, MODEL ### PART CIRCLE
TANK, TYPE/SIZE ####
RECYCLED WATER SIGN, TYPE/SIZE ####
DN### HDPE PN12.5 LILAC MAIN PIPE - C
DN### HDPE PN12.5 LILAC LAT PIPE - BDN### HDPE PN12.5 LILAC LAT PIPE - CPOWER CABLE & CONDUIT ROUTE (240-415V)
FOR ROTOR MODEL & NOZZLE REFER ROTOR TABLE, BASED ON SPACING
A 30/07/2021 EM SJ CONCEPTS - FOR COMMENT & APPROVAL
18
18
18
18
15
15
REFER TO DWG 15888-204
REFER TO DWG 15888-202
REF
ER T
O D
WG
158
88-2
01
REF
ER T
O D
WG
158
88-2
02
REFER TO DWG 15888-203
REFER TO DWG 15888-202
REF
ER T
O D
WG
158
88-2
01
REF
ER T
O D
WG
158
88-2
02
MALPAS ST
7
10
T8
T11
12
T13
DAM
CLIENT:
PROJECT:
SHEET OFDRAWING No. REVISION
DES/DRAWN:
APPROVED:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
This document is and shall remain the property ofHYDRO-PLAN PTY. LTD. The document may onlybe used for the purpose for which it wascommissioned and in accordance with the terms ofengagement for the commission.
The arrangement and general details as shown onthis drawing are essentially diagrammatic and mustbe applied to the circumstances as found on site.
COPYRIGHT
SmartApprovedWaterMark
DRAFT REF:
CHECKED:
NORTH
Dra
win
g fil
e: D
:\Wat
erEt
\DW
G C
AD\H
P te
mp\
1588
BIT
S D
ENN
IS P
ARK
(tem
p D
dve
)\H
P up
d ge
o R
1\15
888-
200-
d2 -
Stan
dard
\158
88-2
00-B
ITS
GO
LF_I
RR
IGAT
ION
(d2)
.dw
g - 0
5/08
/202
1 8:
19 P
M O
rigin
al S
ize:
ISO
FU
LL B
LEED
A3
(420
.00
X 29
7.00
MM
)
DATE:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
http://hydroplan.com.au
SYDNEYADELAIDEPERTH BEIJINGBRISBANEMELBOURNE
GLADESTONE REGIONAL COUNCIL182-21 BITS CLUB SITE & DENNIS PARK SPORTS COMPLEX
DETAILED DESIGN IRRIGATION SYSTEM
EM
PH
SJ
12/05/2021
4-GRC-d2 18 A
BITS GOLF COURSE - LAYOUT 2
15888-202 4
SCALE 1: SIZE A3SCALE 1: ORIGINAL SIZE
-4 0 4 8 12 16 20 40m
400 A1 800
IRR OPTIONS 1&22X OEM ROTOR PERFORMANCE
CONCEPTSFOR COMMENT & APPROVAL
LEGEND:
DN### HDPE PN12.5 LILAC MAIN PIPE - A
DN### HDPE PN12.5 LILAC LAT PIPE - A* (CONCEPT)
CONTROL WIRE ROUTE B, ## (NOT SHOWN) CONTROL WIRE ROUTE A, ## (NOT SHOWN)
PUMP: TYPE/SIZE ####
IRRIGATION CONTROLLER, TYPE ####
ISOLATION VALVE (DN## LINE SIZE) C/W 910 VB
DN50 AIR VALVE C/W 910VB (NOT SHOWN DN25 QCV C/W 910VB (NOT SHOWN)
BACKFLOW ASSEMBLY, TYPE/SIZE ####
WEATHER SENSOR, TYPE ####
DN## SOLENOID VALVE , TYPE ####
FILTER AUTO SCREEN, DN###, 200 MICRON
DN25/32 ROTOR A C/W SJR, MODEL ### FULL CIRCLE
DN### HDPE PN12.5 LILAC MAIN PIPE - B* (CONCEPT)
FLOW METER, TYPE/SIZE ####
LOW LEVEL SENSOR (NOT SHOWN)
DN## SOLENOID VALVE , TYPE #### * (CONCEPT)
DN25/32 ROTOR B C/W SJR, MODEL ### PART CIRCLE
TANK, TYPE/SIZE ####
RECYCLED WATER SIGN, TYPE/SIZE ####
DN### HDPE PN12.5 LILAC MAIN PIPE - C
DN### HDPE PN12.5 LILAC LAT PIPE - BDN### HDPE PN12.5 LILAC LAT PIPE - CPOWER CABLE & CONDUIT ROUTE (240-415V)
FOR ROTOR MODEL & NOZZLE REFER ROTOR TABLE, BASED ON SPACING
A 30/07/2021 EM SJ CONCEPTS - FOR COMMENT & APPROVAL
20
15
15
18
18
15
15
14
14
17
14
1416
18
15
REFER TO DWG 15888-203
REFER TO DWG 15888-206
REFER TO DWG 15888-201
REFER TO DWG 15888-203 REFER TO DWG 15888-203
REFER TO DWG 15888-202
REF
ER T
O D
WG
158
88-2
03
REF
ER T
O D
WG
158
88-2
04
7T2
FUTURE HOLESTAKE OFF POINT
MAIN PIPE & CABLE PIT
CLIENT:
PROJECT:
SHEET OFDRAWING No. REVISION
DES/DRAWN:
APPROVED:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
This document is and shall remain the property ofHYDRO-PLAN PTY. LTD. The document may onlybe used for the purpose for which it wascommissioned and in accordance with the terms ofengagement for the commission.
The arrangement and general details as shown onthis drawing are essentially diagrammatic and mustbe applied to the circumstances as found on site.
COPYRIGHT
SmartApprovedWaterMark
DRAFT REF:
CHECKED:
NORTH
Dra
win
g fil
e: D
:\Wat
erEt
\DW
G C
AD\H
P te
mp\
1588
BIT
S D
ENN
IS P
ARK
(tem
p D
dve
)\H
P up
d ge
o R
1\15
888-
200-
d2 -
Stan
dard
\158
88-2
00-B
ITS
GO
LF_I
RR
IGAT
ION
(d2)
.dw
g - 0
5/08
/202
1 8:
19 P
M O
rigin
al S
ize:
ISO
FU
LL B
LEED
A3
(420
.00
X 29
7.00
MM
)
DATE:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
http://hydroplan.com.au
SYDNEYADELAIDEPERTH BEIJINGBRISBANEMELBOURNE
GLADESTONE REGIONAL COUNCIL182-21 BITS CLUB SITE & DENNIS PARK SPORTS COMPLEX
DETAILED DESIGN IRRIGATION SYSTEM
EM
PH
SJ
12/05/2021
4-GRC-d2 18 A
BITS GOLF COURSE - LAYOUT 3
15888-203 5
SCALE 1: SIZE A3SCALE 1: ORIGINAL SIZE
-4 0 4 8 12 16 20 40m
400 A1 800
IRR OPTIONS 1&22X OEM ROTOR PERFORMANCE
CONCEPTSFOR COMMENT & APPROVAL
LEGEND:
DN### HDPE PN12.5 LILAC MAIN PIPE - A
DN### HDPE PN12.5 LILAC LAT PIPE - A* (CONCEPT)
CONTROL WIRE ROUTE B, ## (NOT SHOWN) CONTROL WIRE ROUTE A, ## (NOT SHOWN)
PUMP: TYPE/SIZE ####
IRRIGATION CONTROLLER, TYPE ####
ISOLATION VALVE (DN## LINE SIZE) C/W 910 VB
DN50 AIR VALVE C/W 910VB (NOT SHOWN DN25 QCV C/W 910VB (NOT SHOWN)
BACKFLOW ASSEMBLY, TYPE/SIZE ####
WEATHER SENSOR, TYPE ####
DN## SOLENOID VALVE , TYPE ####
FILTER AUTO SCREEN, DN###, 200 MICRON
DN25/32 ROTOR A C/W SJR, MODEL ### FULL CIRCLE
DN### HDPE PN12.5 LILAC MAIN PIPE - B* (CONCEPT)
FLOW METER, TYPE/SIZE ####
LOW LEVEL SENSOR (NOT SHOWN)
DN## SOLENOID VALVE , TYPE #### * (CONCEPT)
DN25/32 ROTOR B C/W SJR, MODEL ### PART CIRCLE
TANK, TYPE/SIZE ####
RECYCLED WATER SIGN, TYPE/SIZE ####
DN### HDPE PN12.5 LILAC MAIN PIPE - C
DN### HDPE PN12.5 LILAC LAT PIPE - BDN### HDPE PN12.5 LILAC LAT PIPE - CPOWER CABLE & CONDUIT ROUTE (240-415V)
FOR ROTOR MODEL & NOZZLE REFER ROTOR TABLE, BASED ON SPACING
A 30/07/2021 EM SJ CONCEPTS - FOR COMMENT & APPROVAL
16
16
20
18
18
REFER TO DWG 15888-204
REFER TO DWG 15888-202
REFER TO DWG 15888-204
REFER TO DWG 15888-207
REFER TO DWG 15888-203
REFER TO DWG 15888-202
REF
ER T
O D
WG
158
88-2
04
REF
ER T
O D
WG
158
88-2
05
REF
ER T
O D
WG
158
88-2
03
REF
ER T
O D
WG
158
88-2
04
1
7T8
CLIENT:
PROJECT:
SHEET OFDRAWING No. REVISION
DES/DRAWN:
APPROVED:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
This document is and shall remain the property ofHYDRO-PLAN PTY. LTD. The document may onlybe used for the purpose for which it wascommissioned and in accordance with the terms ofengagement for the commission.
The arrangement and general details as shown onthis drawing are essentially diagrammatic and mustbe applied to the circumstances as found on site.
COPYRIGHT
SmartApprovedWaterMark
DRAFT REF:
CHECKED:
NORTH
Dra
win
g fil
e: D
:\Wat
erEt
\DW
G C
AD\H
P te
mp\
1588
BIT
S D
ENN
IS P
ARK
(tem
p D
dve
)\H
P up
d ge
o R
1\15
888-
200-
d2 -
Stan
dard
\158
88-2
00-B
ITS
GO
LF_I
RR
IGAT
ION
(d2)
.dw
g - 0
5/08
/202
1 8:
19 P
M O
rigin
al S
ize:
ISO
FU
LL B
LEED
A3
(420
.00
X 29
7.00
MM
)
DATE:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
http://hydroplan.com.au
SYDNEYADELAIDEPERTH BEIJINGBRISBANEMELBOURNE
GLADESTONE REGIONAL COUNCIL182-21 BITS CLUB SITE & DENNIS PARK SPORTS COMPLEX
DETAILED DESIGN IRRIGATION SYSTEM
EM
PH
SJ
12/05/2021
4-GRC-d2 18 A
BITS GOLF COURSE - LAYOUT 4
15888-204 6
SCALE 1: SIZE A3SCALE 1: ORIGINAL SIZE
-4 0 4 8 12 16 20 40m
400 A1 800
IRR OPTIONS 1&22X OEM ROTOR PERFORMANCE
CONCEPTSFOR COMMENT & APPROVAL
A 30/07/2021 EM SJ CONCEPTS - FOR COMMENT & APPROVAL
20
20
18
18
15
REFER TO DWG 15888-205
REFER TO DWG 15888-208
REF
ER T
O D
WG
158
88-2
04
REF
ER T
O D
WG
158
88-2
05
JACAR
AND
A DR
CLIENT:
PROJECT:
SHEET OFDRAWING No. REVISION
DES/DRAWN:
APPROVED:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
This document is and shall remain the property ofHYDRO-PLAN PTY. LTD. The document may onlybe used for the purpose for which it wascommissioned and in accordance with the terms ofengagement for the commission.
The arrangement and general details as shown onthis drawing are essentially diagrammatic and mustbe applied to the circumstances as found on site.
COPYRIGHT
SmartApprovedWaterMark
DRAFT REF:
CHECKED:
NORTH
Dra
win
g fil
e: D
:\Wat
erEt
\DW
G C
AD\H
P te
mp\
1588
BIT
S D
ENN
IS P
ARK
(tem
p D
dve
)\H
P up
d ge
o R
1\15
888-
200-
d2 -
Stan
dard
\158
88-2
00-B
ITS
GO
LF_I
RR
IGAT
ION
(d2)
.dw
g - 0
5/08
/202
1 8:
19 P
M O
rigin
al S
ize:
ISO
FU
LL B
LEED
A3
(420
.00
X 29
7.00
MM
)
DATE:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
http://hydroplan.com.au
SYDNEYADELAIDEPERTH BEIJINGBRISBANEMELBOURNE
GLADESTONE REGIONAL COUNCIL182-21 BITS CLUB SITE & DENNIS PARK SPORTS COMPLEX
DETAILED DESIGN IRRIGATION SYSTEM
EM
PH
SJ
12/05/2021
4-GRC-d2 18 A
BITS GOLF COURSE - LAYOUT 5
15888-205 7
SCALE 1: SIZE A3SCALE 1: ORIGINAL SIZE
-4 0 4 8 12 16 20 40m
400 A1 800
IRR OPTIONS 1&22X OEM ROTOR PERFORMANCE
CONCEPTSFOR COMMENT & APPROVAL
LEGEND:
DN### HDPE PN12.5 LILAC MAIN PIPE - A
DN### HDPE PN12.5 LILAC LAT PIPE - A* (CONCEPT)
CONTROL WIRE ROUTE B, ## (NOT SHOWN) CONTROL WIRE ROUTE A, ## (NOT SHOWN)
PUMP: TYPE/SIZE ####
IRRIGATION CONTROLLER, TYPE ####
ISOLATION VALVE (DN## LINE SIZE) C/W 910 VB
DN50 AIR VALVE C/W 910VB (NOT SHOWN DN25 QCV C/W 910VB (NOT SHOWN)
BACKFLOW ASSEMBLY, TYPE/SIZE ####
WEATHER SENSOR, TYPE ####
DN## SOLENOID VALVE , TYPE ####
FILTER AUTO SCREEN, DN###, 200 MICRON
DN25/32 ROTOR A C/W SJR, MODEL ### FULL CIRCLE
DN### HDPE PN12.5 LILAC MAIN PIPE - B* (CONCEPT)
FLOW METER, TYPE/SIZE ####
LOW LEVEL SENSOR (NOT SHOWN)
DN## SOLENOID VALVE , TYPE #### * (CONCEPT)
DN25/32 ROTOR B C/W SJR, MODEL ### PART CIRCLE
TANK, TYPE/SIZE ####
RECYCLED WATER SIGN, TYPE/SIZE ####
DN### HDPE PN12.5 LILAC MAIN PIPE - C
DN### HDPE PN12.5 LILAC LAT PIPE - BDN### HDPE PN12.5 LILAC LAT PIPE - CPOWER CABLE & CONDUIT ROUTE (240-415V)
FOR ROTOR MODEL & NOZZLE REFER ROTOR TABLE, BASED ON SPACING
A 30/07/2021 EM SJ CONCEPTS - FOR COMMENT & APPROVAL
REFER TO DWG 15888-203
REFER TO DWG 15888-206
REF
ER T
O D
WG
158
88-2
06
REF
ER T
O D
WG
158
88-2
07
REFER TO DWG 15888-206
REFER TO DWG 15888-209
3
T4
FUTURE HOLESTAKE OFF POINT
MAIN PIPE & CABLE PIT
CLIENT:
PROJECT:
SHEET OFDRAWING No. REVISION
DES/DRAWN:
APPROVED:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
This document is and shall remain the property ofHYDRO-PLAN PTY. LTD. The document may onlybe used for the purpose for which it wascommissioned and in accordance with the terms ofengagement for the commission.
The arrangement and general details as shown onthis drawing are essentially diagrammatic and mustbe applied to the circumstances as found on site.
COPYRIGHT
SmartApprovedWaterMark
DRAFT REF:
CHECKED:
NORTH
Dra
win
g fil
e: D
:\Wat
erEt
\DW
G C
AD\H
P te
mp\
1588
BIT
S D
ENN
IS P
ARK
(tem
p D
dve
)\H
P up
d ge
o R
1\15
888-
200-
d2 -
Stan
dard
\158
88-2
00-B
ITS
GO
LF_I
RR
IGAT
ION
(d2)
.dw
g - 0
5/08
/202
1 8:
19 P
M O
rigin
al S
ize:
ISO
FU
LL B
LEED
A3
(420
.00
X 29
7.00
MM
)
DATE:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
http://hydroplan.com.au
SYDNEYADELAIDEPERTH BEIJINGBRISBANEMELBOURNE
GLADESTONE REGIONAL COUNCIL182-21 BITS CLUB SITE & DENNIS PARK SPORTS COMPLEX
DETAILED DESIGN IRRIGATION SYSTEM
EM
PH
SJ
12/05/2021
4-GRC-d2 18 A
BITS GOLF COURSE - LAYOUT 6
15888-206 8
SCALE 1: SIZE A3SCALE 1: ORIGINAL SIZE
-4 0 4 8 12 16 20 40m
400 A1 800
IRR OPTIONS 1&22X OEM ROTOR PERFORMANCE
CONCEPTSFOR COMMENT & APPROVAL
LEGEND:
DN### HDPE PN12.5 LILAC MAIN PIPE - A
DN### HDPE PN12.5 LILAC LAT PIPE - A* (CONCEPT)
CONTROL WIRE ROUTE B, ## (NOT SHOWN) CONTROL WIRE ROUTE A, ## (NOT SHOWN)
PUMP: TYPE/SIZE ####
IRRIGATION CONTROLLER, TYPE ####
ISOLATION VALVE (DN## LINE SIZE) C/W 910 VB
DN50 AIR VALVE C/W 910VB (NOT SHOWN DN25 QCV C/W 910VB (NOT SHOWN)
BACKFLOW ASSEMBLY, TYPE/SIZE ####
WEATHER SENSOR, TYPE ####
DN## SOLENOID VALVE , TYPE ####
FILTER AUTO SCREEN, DN###, 200 MICRON
DN25/32 ROTOR A C/W SJR, MODEL ### FULL CIRCLE
DN### HDPE PN12.5 LILAC MAIN PIPE - B* (CONCEPT)
FLOW METER, TYPE/SIZE ####
LOW LEVEL SENSOR (NOT SHOWN)
DN## SOLENOID VALVE , TYPE #### * (CONCEPT)
DN25/32 ROTOR B C/W SJR, MODEL ### PART CIRCLE
TANK, TYPE/SIZE ####
RECYCLED WATER SIGN, TYPE/SIZE ####
DN### HDPE PN12.5 LILAC MAIN PIPE - C
DN### HDPE PN12.5 LILAC LAT PIPE - BDN### HDPE PN12.5 LILAC LAT PIPE - CPOWER CABLE & CONDUIT ROUTE (240-415V)
FOR ROTOR MODEL & NOZZLE REFER ROTOR TABLE, BASED ON SPACING
A 30/07/2021 EM SJ CONCEPTS - FOR COMMENT & APPROVAL
20
20
18
18
15
REFER TO DWG 15888-204
REFER TO DWG 15888-207
REF
ER T
O D
WG
158
88-2
06
REF
ER T
O D
WG
158
88-2
07
REF
ER T
O D
WG
158
88-2
07
REF
ER T
O D
WG
158
88-2
08
REFER TO DWG 15888-207
REFER TO DWG 15888-210
8
9
DAM
DAM
PS
T1
T10
CLIENT:
PROJECT:
SHEET OFDRAWING No. REVISION
DES/DRAWN:
APPROVED:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
This document is and shall remain the property ofHYDRO-PLAN PTY. LTD. The document may onlybe used for the purpose for which it wascommissioned and in accordance with the terms ofengagement for the commission.
The arrangement and general details as shown onthis drawing are essentially diagrammatic and mustbe applied to the circumstances as found on site.
COPYRIGHT
SmartApprovedWaterMark
DRAFT REF:
CHECKED:
NORTH
Dra
win
g fil
e: D
:\Wat
erEt
\DW
G C
AD\H
P te
mp\
1588
BIT
S D
ENN
IS P
ARK
(tem
p D
dve
)\H
P up
d ge
o R
1\15
888-
200-
d2 -
Stan
dard
\158
88-2
00-B
ITS
GO
LF_I
RR
IGAT
ION
(d2)
.dw
g - 0
5/08
/202
1 8:
19 P
M O
rigin
al S
ize:
ISO
FU
LL B
LEED
A3
(420
.00
X 29
7.00
MM
)
DATE:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
http://hydroplan.com.au
SYDNEYADELAIDEPERTH BEIJINGBRISBANEMELBOURNE
GLADESTONE REGIONAL COUNCIL182-21 BITS CLUB SITE & DENNIS PARK SPORTS COMPLEX
DETAILED DESIGN IRRIGATION SYSTEM
EM
PH
SJ
12/05/2021
4-GRC-d2 18 A
BITS GOLF COURSE - LAYOUT 7
15888-207 9
SCALE 1: SIZE A3SCALE 1: ORIGINAL SIZE
-4 0 4 8 12 16 20 40m
400 A1 800
IRR OPTIONS 1&22X OEM ROTOR PERFORMANCE
CONCEPTSFOR COMMENT & APPROVAL
LEGEND:
DN### HDPE PN12.5 LILAC MAIN PIPE - A
DN### HDPE PN12.5 LILAC LAT PIPE - A* (CONCEPT)
CONTROL WIRE ROUTE B, ## (NOT SHOWN) CONTROL WIRE ROUTE A, ## (NOT SHOWN)
PUMP: TYPE/SIZE ####
IRRIGATION CONTROLLER, TYPE ####
ISOLATION VALVE (DN## LINE SIZE) C/W 910 VB
DN50 AIR VALVE C/W 910VB (NOT SHOWN DN25 QCV C/W 910VB (NOT SHOWN)
BACKFLOW ASSEMBLY, TYPE/SIZE ####
WEATHER SENSOR, TYPE ####
DN## SOLENOID VALVE , TYPE ####
FILTER AUTO SCREEN, DN###, 200 MICRON
DN25/32 ROTOR A C/W SJR, MODEL ### FULL CIRCLE
DN### HDPE PN12.5 LILAC MAIN PIPE - B* (CONCEPT)
FLOW METER, TYPE/SIZE ####
LOW LEVEL SENSOR (NOT SHOWN)
DN## SOLENOID VALVE , TYPE #### * (CONCEPT)
DN25/32 ROTOR B C/W SJR, MODEL ### PART CIRCLE
TANK, TYPE/SIZE ####
RECYCLED WATER SIGN, TYPE/SIZE ####
DN### HDPE PN12.5 LILAC MAIN PIPE - C
DN### HDPE PN12.5 LILAC LAT PIPE - BDN### HDPE PN12.5 LILAC LAT PIPE - CPOWER CABLE & CONDUIT ROUTE (240-415V)
FOR ROTOR MODEL & NOZZLE REFER ROTOR TABLE, BASED ON SPACING
A 30/07/2021 EM SJ CONCEPTS - FOR COMMENT & APPROVAL
18
16
16
16
16
18
18
18
18
18
15
15
DISCONNECT SUCTION PIPE & POWERTO EXISTING PUMP SHED, MAKE SAFE
CONNECT NEW SUCTIONPIPE TO NEW PUMP UNIT/S
REF
ER T
O D
WG
158
88-2
07
REF
ER T
O D
WG
158
88-2
08
REFER TO DWG 15888-205
REFER TO DWG 15888-208
REFER TO DWG 15888-208
REFER TO DWG 15888-211
PG
NY
5
PRO
T6
T10
13
CG
CLIENT:
PROJECT:
SHEET OFDRAWING No. REVISION
DES/DRAWN:
APPROVED:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
This document is and shall remain the property ofHYDRO-PLAN PTY. LTD. The document may onlybe used for the purpose for which it wascommissioned and in accordance with the terms ofengagement for the commission.
The arrangement and general details as shown onthis drawing are essentially diagrammatic and mustbe applied to the circumstances as found on site.
COPYRIGHT
SmartApprovedWaterMark
DRAFT REF:
CHECKED:
NORTH
Dra
win
g fil
e: D
:\Wat
erEt
\DW
G C
AD\H
P te
mp\
1588
BIT
S D
ENN
IS P
ARK
(tem
p D
dve
)\H
P up
d ge
o R
1\15
888-
200-
d2 -
Stan
dard
\158
88-2
00-B
ITS
GO
LF_I
RR
IGAT
ION
(d2)
.dw
g - 0
5/08
/202
1 8:
19 P
M O
rigin
al S
ize:
ISO
FU
LL B
LEED
A3
(420
.00
X 29
7.00
MM
)
DATE:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
http://hydroplan.com.au
SYDNEYADELAIDEPERTH BEIJINGBRISBANEMELBOURNE
GLADESTONE REGIONAL COUNCIL182-21 BITS CLUB SITE & DENNIS PARK SPORTS COMPLEX
DETAILED DESIGN IRRIGATION SYSTEM
EM
PH
SJ
12/05/2021
4-GRC-d2 18 A
BITS GOLF COURSE - LAYOUT 8
15888-208 10
SCALE 1: SIZE A3SCALE 1: ORIGINAL SIZE
-4 0 4 8 12 16 20 40m
400 A1 800
IRR OPTIONS 1&22X OEM ROTOR PERFORMANCE
CONCEPTSFOR COMMENT & APPROVAL
LEGEND:
DN### HDPE PN12.5 LILAC MAIN PIPE - A
DN### HDPE PN12.5 LILAC LAT PIPE - A* (CONCEPT)
CONTROL WIRE ROUTE B, ## (NOT SHOWN) CONTROL WIRE ROUTE A, ## (NOT SHOWN)
PUMP: TYPE/SIZE ####
IRRIGATION CONTROLLER, TYPE ####
ISOLATION VALVE (DN## LINE SIZE) C/W 910 VB
DN50 AIR VALVE C/W 910VB (NOT SHOWN DN25 QCV C/W 910VB (NOT SHOWN)
BACKFLOW ASSEMBLY, TYPE/SIZE ####
WEATHER SENSOR, TYPE ####
DN## SOLENOID VALVE , TYPE ####
FILTER AUTO SCREEN, DN###, 200 MICRON
DN25/32 ROTOR A C/W SJR, MODEL ### FULL CIRCLE
DN### HDPE PN12.5 LILAC MAIN PIPE - B* (CONCEPT)
FLOW METER, TYPE/SIZE ####
LOW LEVEL SENSOR (NOT SHOWN)
DN## SOLENOID VALVE , TYPE #### * (CONCEPT)
DN25/32 ROTOR B C/W SJR, MODEL ### PART CIRCLE
TANK, TYPE/SIZE ####
RECYCLED WATER SIGN, TYPE/SIZE ####
DN### HDPE PN12.5 LILAC MAIN PIPE - C
DN### HDPE PN12.5 LILAC LAT PIPE - BDN### HDPE PN12.5 LILAC LAT PIPE - CPOWER CABLE & CONDUIT ROUTE (240-415V)
FOR ROTOR MODEL & NOZZLE REFER ROTOR TABLE, BASED ON SPACING
A 30/07/2021 EM SJ CONCEPTS - FOR COMMENT & APPROVAL
16
16
FOR PUMP STATION DETAILSREFER DWG # 15888-220
FOR POTABLE WATER SUPPLYOPTION REFER DWG # 15888-220
20
20
20
20
18
18
15
15
14
14
18
18
REFER TO DWG 15888-206
REFER TO DWG 15888-209
REF
ER T
O D
WG
158
88-2
09
REF
ER T
O D
WG
158
88-2
10
2
T3
CLIENT:
PROJECT:
SHEET OFDRAWING No. REVISION
DES/DRAWN:
APPROVED:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
This document is and shall remain the property ofHYDRO-PLAN PTY. LTD. The document may onlybe used for the purpose for which it wascommissioned and in accordance with the terms ofengagement for the commission.
The arrangement and general details as shown onthis drawing are essentially diagrammatic and mustbe applied to the circumstances as found on site.
COPYRIGHT
SmartApprovedWaterMark
DRAFT REF:
CHECKED:
NORTH
Dra
win
g fil
e: D
:\Wat
erEt
\DW
G C
AD\H
P te
mp\
1588
BIT
S D
ENN
IS P
ARK
(tem
p D
dve
)\H
P up
d ge
o R
1\15
888-
200-
d2 -
Stan
dard
\158
88-2
00-B
ITS
GO
LF_I
RR
IGAT
ION
(d2)
.dw
g - 0
5/08
/202
1 8:
19 P
M O
rigin
al S
ize:
ISO
FU
LL B
LEED
A3
(420
.00
X 29
7.00
MM
)
DATE:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
http://hydroplan.com.au
SYDNEYADELAIDEPERTH BEIJINGBRISBANEMELBOURNE
GLADESTONE REGIONAL COUNCIL182-21 BITS CLUB SITE & DENNIS PARK SPORTS COMPLEX
DETAILED DESIGN IRRIGATION SYSTEM
EM
PH
SJ
12/05/2021
4-GRC-d2 18 A
BITS GOLF COURSE - LAYOUT 9
15888-209 11
SCALE 1: SIZE A3SCALE 1: ORIGINAL SIZE
-4 0 4 8 12 16 20 40m
400 A1 800
IRR OPTIONS 1&22X OEM ROTOR PERFORMANCE
CONCEPTSFOR COMMENT & APPROVAL
LEGEND:
DN### HDPE PN12.5 LILAC MAIN PIPE - A
DN### HDPE PN12.5 LILAC LAT PIPE - A* (CONCEPT)
CONTROL WIRE ROUTE B, ## (NOT SHOWN) CONTROL WIRE ROUTE A, ## (NOT SHOWN)
PUMP: TYPE/SIZE ####
IRRIGATION CONTROLLER, TYPE ####
ISOLATION VALVE (DN## LINE SIZE) C/W 910 VB
DN50 AIR VALVE C/W 910VB (NOT SHOWN DN25 QCV C/W 910VB (NOT SHOWN)
BACKFLOW ASSEMBLY, TYPE/SIZE ####
WEATHER SENSOR, TYPE ####
DN## SOLENOID VALVE , TYPE ####
FILTER AUTO SCREEN, DN###, 200 MICRON
DN25/32 ROTOR A C/W SJR, MODEL ### FULL CIRCLE
DN### HDPE PN12.5 LILAC MAIN PIPE - B* (CONCEPT)
FLOW METER, TYPE/SIZE ####
LOW LEVEL SENSOR (NOT SHOWN)
DN## SOLENOID VALVE , TYPE #### * (CONCEPT)
DN25/32 ROTOR B C/W SJR, MODEL ### PART CIRCLE
TANK, TYPE/SIZE ####
RECYCLED WATER SIGN, TYPE/SIZE ####
DN### HDPE PN12.5 LILAC MAIN PIPE - C
DN### HDPE PN12.5 LILAC LAT PIPE - BDN### HDPE PN12.5 LILAC LAT PIPE - CPOWER CABLE & CONDUIT ROUTE (240-415V)
FOR ROTOR MODEL & NOZZLE REFER ROTOR TABLE, BASED ON SPACING
A 30/07/2021 EM SJ CONCEPTS - FOR COMMENT & APPROVAL
15
15
18
1616
REFER TO DWG 15888-207
REFER TO DWG 15888-210
REF
ER T
O D
WG
158
88-2
09
REF
ER T
O D
WG
158
88-2
10
REF
ER T
O D
WG
158
88-2
10
REF
ER T
O D
WG
158
88-2
11
4
6
T5
T7
T9
CLIENT:
PROJECT:
SHEET OFDRAWING No. REVISION
DES/DRAWN:
APPROVED:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
This document is and shall remain the property ofHYDRO-PLAN PTY. LTD. The document may onlybe used for the purpose for which it wascommissioned and in accordance with the terms ofengagement for the commission.
The arrangement and general details as shown onthis drawing are essentially diagrammatic and mustbe applied to the circumstances as found on site.
COPYRIGHT
SmartApprovedWaterMark
DRAFT REF:
CHECKED:
NORTH
Dra
win
g fil
e: D
:\Wat
erEt
\DW
G C
AD\H
P te
mp\
1588
BIT
S D
ENN
IS P
ARK
(tem
p D
dve
)\H
P up
d ge
o R
1\15
888-
200-
d2 -
Stan
dard
\158
88-2
00-B
ITS
GO
LF_I
RR
IGAT
ION
(d2)
.dw
g - 0
5/08
/202
1 8:
19 P
M O
rigin
al S
ize:
ISO
FU
LL B
LEED
A3
(420
.00
X 29
7.00
MM
)
DATE:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
http://hydroplan.com.au
SYDNEYADELAIDEPERTH BEIJINGBRISBANEMELBOURNE
GLADESTONE REGIONAL COUNCIL182-21 BITS CLUB SITE & DENNIS PARK SPORTS COMPLEX
DETAILED DESIGN IRRIGATION SYSTEM
EM
PH
SJ
12/05/2021
4-GRC-d2 18 A
BITS GOLF COURSE - LAYOUT 10
15888-210 12
SCALE 1: SIZE A3SCALE 1: ORIGINAL SIZE
-4 0 4 8 12 16 20 40m
400 A1 800
IRR OPTIONS 1&22X OEM ROTOR PERFORMANCE
CONCEPTSFOR COMMENT & APPROVAL
LEGEND:
DN### HDPE PN12.5 LILAC MAIN PIPE - A
DN### HDPE PN12.5 LILAC LAT PIPE - A* (CONCEPT)
CONTROL WIRE ROUTE B, ## (NOT SHOWN) CONTROL WIRE ROUTE A, ## (NOT SHOWN)
PUMP: TYPE/SIZE ####
IRRIGATION CONTROLLER, TYPE ####
ISOLATION VALVE (DN## LINE SIZE) C/W 910 VB
DN50 AIR VALVE C/W 910VB (NOT SHOWN DN25 QCV C/W 910VB (NOT SHOWN)
BACKFLOW ASSEMBLY, TYPE/SIZE ####
WEATHER SENSOR, TYPE ####
DN## SOLENOID VALVE , TYPE ####
FILTER AUTO SCREEN, DN###, 200 MICRON
DN25/32 ROTOR A C/W SJR, MODEL ### FULL CIRCLE
DN### HDPE PN12.5 LILAC MAIN PIPE - B* (CONCEPT)
FLOW METER, TYPE/SIZE ####
LOW LEVEL SENSOR (NOT SHOWN)
DN## SOLENOID VALVE , TYPE #### * (CONCEPT)
DN25/32 ROTOR B C/W SJR, MODEL ### PART CIRCLE
TANK, TYPE/SIZE ####
RECYCLED WATER SIGN, TYPE/SIZE ####
DN### HDPE PN12.5 LILAC MAIN PIPE - C
DN### HDPE PN12.5 LILAC LAT PIPE - BDN### HDPE PN12.5 LILAC LAT PIPE - CPOWER CABLE & CONDUIT ROUTE (240-415V)
FOR ROTOR MODEL & NOZZLE REFER ROTOR TABLE, BASED ON SPACING
A 30/07/2021 EM SJ CONCEPTS - FOR COMMENT & APPROVAL
16
18
18
18
18
18
16
15
REFER TO DWG 15888-208
REFER TO DWG 15888-211
REF
ER T
O D
WG
158
88-2
10
REF
ER T
O D
WG
158
88-2
11
REFER TO DWG 15888-211
REFER TO DWG 15888-212
FUTURE HOLESTAKE OFF POINT
MAIN PIPE & CABLE PIT
CLIENT:
PROJECT:
SHEET OFDRAWING No. REVISION
DES/DRAWN:
APPROVED:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
This document is and shall remain the property ofHYDRO-PLAN PTY. LTD. The document may onlybe used for the purpose for which it wascommissioned and in accordance with the terms ofengagement for the commission.
The arrangement and general details as shown onthis drawing are essentially diagrammatic and mustbe applied to the circumstances as found on site.
COPYRIGHT
SmartApprovedWaterMark
DRAFT REF:
CHECKED:
NORTH
Dra
win
g fil
e: D
:\Wat
erEt
\DW
G C
AD\H
P te
mp\
1588
BIT
S D
ENN
IS P
ARK
(tem
p D
dve
)\H
P up
d ge
o R
1\15
888-
200-
d2 -
Stan
dard
\158
88-2
00-B
ITS
GO
LF_I
RR
IGAT
ION
(d2)
.dw
g - 0
5/08
/202
1 8:
19 P
M O
rigin
al S
ize:
ISO
FU
LL B
LEED
A3
(420
.00
X 29
7.00
MM
)
DATE:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
http://hydroplan.com.au
SYDNEYADELAIDEPERTH BEIJINGBRISBANEMELBOURNE
GLADESTONE REGIONAL COUNCIL182-21 BITS CLUB SITE & DENNIS PARK SPORTS COMPLEX
DETAILED DESIGN IRRIGATION SYSTEM
EM
PH
SJ
12/05/2021
4-GRC-d2 18 A
BITS GOLF COURSE - LAYOUT 11
15888-211 13
SCALE 1: SIZE A3SCALE 1: ORIGINAL SIZE
-4 0 4 8 12 16 20 40m
400 A1 800
IRR OPTIONS 1&22X OEM ROTOR PERFORMANCE
CONCEPTSFOR COMMENT & APPROVAL
LEGEND:
DN### HDPE PN12.5 LILAC MAIN PIPE - A
DN### HDPE PN12.5 LILAC LAT PIPE - A* (CONCEPT)
CONTROL WIRE ROUTE B, ## (NOT SHOWN) CONTROL WIRE ROUTE A, ## (NOT SHOWN)
PUMP: TYPE/SIZE ####
IRRIGATION CONTROLLER, TYPE ####
ISOLATION VALVE (DN## LINE SIZE) C/W 910 VB
DN50 AIR VALVE C/W 910VB (NOT SHOWN DN25 QCV C/W 910VB (NOT SHOWN)
BACKFLOW ASSEMBLY, TYPE/SIZE ####
WEATHER SENSOR, TYPE ####
DN## SOLENOID VALVE , TYPE ####
FILTER AUTO SCREEN, DN###, 200 MICRON
DN25/32 ROTOR A C/W SJR, MODEL ### FULL CIRCLE
DN### HDPE PN12.5 LILAC MAIN PIPE - B* (CONCEPT)
FLOW METER, TYPE/SIZE ####
LOW LEVEL SENSOR (NOT SHOWN)
DN## SOLENOID VALVE , TYPE #### * (CONCEPT)
DN25/32 ROTOR B C/W SJR, MODEL ### PART CIRCLE
TANK, TYPE/SIZE ####
RECYCLED WATER SIGN, TYPE/SIZE ####
DN### HDPE PN12.5 LILAC MAIN PIPE - C
DN### HDPE PN12.5 LILAC LAT PIPE - BDN### HDPE PN12.5 LILAC LAT PIPE - CPOWER CABLE & CONDUIT ROUTE (240-415V)
FOR ROTOR MODEL & NOZZLE REFER ROTOR TABLE, BASED ON SPACING
A 30/07/2021 EM SJ CONCEPTS - FOR COMMENT & APPROVAL
EXISTING RECYCLED WATER SUPPLY TANKSREFER DWG # 1588-223 FOR NOTES & DETAILS
REFER TO DWG 15888-211
REFER TO DWG 15888-212
CLIENT:
PROJECT:
SHEET OFDRAWING No. REVISION
DES/DRAWN:
APPROVED:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
This document is and shall remain the property ofHYDRO-PLAN PTY. LTD. The document may onlybe used for the purpose for which it wascommissioned and in accordance with the terms ofengagement for the commission.
The arrangement and general details as shown onthis drawing are essentially diagrammatic and mustbe applied to the circumstances as found on site.
COPYRIGHT
SmartApprovedWaterMark
DRAFT REF:
CHECKED:
NORTH
Dra
win
g fil
e: D
:\Wat
erEt
\DW
G C
AD\H
P te
mp\
1588
BIT
S D
ENN
IS P
ARK
(tem
p D
dve
)\H
P up
d ge
o R
1\15
888-
200-
d2 -
Stan
dard
\158
88-2
00-B
ITS
GO
LF_I
RR
IGAT
ION
(d2)
.dw
g - 0
5/08
/202
1 8:
19 P
M O
rigin
al S
ize:
ISO
FU
LL B
LEED
A3
(420
.00
X 29
7.00
MM
)
DATE:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
http://hydroplan.com.au
SYDNEYADELAIDEPERTH BEIJINGBRISBANEMELBOURNE
GLADESTONE REGIONAL COUNCIL182-21 BITS CLUB SITE & DENNIS PARK SPORTS COMPLEX
DETAILED DESIGN IRRIGATION SYSTEM
EM
PH
SJ
12/05/2021
4-GRC-d2 18 A
BITS GOLF COURSE - LAYOUT 12
15888-212 14
SCALE 1: SIZE A3SCALE 1: ORIGINAL SIZE
-4 0 4 8 12 16 20 40m
400 A1 800
IRR OPTIONS 1&22X OEM ROTOR PERFORMANCE
CONCEPTSFOR COMMENT & APPROVAL
LEGEND:
DN### HDPE PN12.5 LILAC MAIN PIPE - A
DN### HDPE PN12.5 LILAC LAT PIPE - A* (CONCEPT)
CONTROL WIRE ROUTE B, ## (NOT SHOWN) CONTROL WIRE ROUTE A, ## (NOT SHOWN)
PUMP: TYPE/SIZE ####
IRRIGATION CONTROLLER, TYPE ####
ISOLATION VALVE (DN## LINE SIZE) C/W 910 VB
DN50 AIR VALVE C/W 910VB (NOT SHOWN DN25 QCV C/W 910VB (NOT SHOWN)
BACKFLOW ASSEMBLY, TYPE/SIZE ####
WEATHER SENSOR, TYPE ####
DN## SOLENOID VALVE , TYPE ####
FILTER AUTO SCREEN, DN###, 200 MICRON
DN25/32 ROTOR A C/W SJR, MODEL ### FULL CIRCLE
DN### HDPE PN12.5 LILAC MAIN PIPE - B* (CONCEPT)
FLOW METER, TYPE/SIZE ####
LOW LEVEL SENSOR (NOT SHOWN)
DN## SOLENOID VALVE , TYPE #### * (CONCEPT)
DN25/32 ROTOR B C/W SJR, MODEL ### PART CIRCLE
TANK, TYPE/SIZE ####
RECYCLED WATER SIGN, TYPE/SIZE ####
DN### HDPE PN12.5 LILAC MAIN PIPE - C
DN### HDPE PN12.5 LILAC LAT PIPE - BDN### HDPE PN12.5 LILAC LAT PIPE - CPOWER CABLE & CONDUIT ROUTE (240-415V)
FOR ROTOR MODEL & NOZZLE REFER ROTOR TABLE, BASED ON SPACING
A 30/07/2021 EM SJ CONCEPTS - FOR COMMENT & APPROVAL
PG
NY
PRO
CLIENT:
PROJECT:
SHEET OFDRAWING No. REVISION
DES/DRAWN:
APPROVED:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
This document is and shall remain the property ofHYDRO-PLAN PTY. LTD. The document may onlybe used for the purpose for which it wascommissioned and in accordance with the terms ofengagement for the commission.
The arrangement and general details as shown onthis drawing are essentially diagrammatic and mustbe applied to the circumstances as found on site.
COPYRIGHT
SmartApprovedWaterMark
DRAFT REF:
CHECKED:
NORTH
Dra
win
g fil
e: D
:\Wat
erEt
\DW
G C
AD\H
P te
mp\
1588
BIT
S D
ENN
IS P
ARK
(tem
p D
dve
)\H
P up
d ge
o R
1\15
888-
200-
d2 -
Stan
dard
\158
88-2
00-B
ITS
GO
LF_I
RR
IGAT
ION
(d2)
.dw
g - 0
5/08
/202
1 8:
19 P
M O
rigin
al S
ize:
ISO
FU
LL B
LEED
A3
(420
.00
X 29
7.00
MM
)
DATE:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
http://hydroplan.com.au
SYDNEYADELAIDEPERTH BEIJINGBRISBANEMELBOURNE
GLADESTONE REGIONAL COUNCIL182-21 BITS CLUB SITE & DENNIS PARK SPORTS COMPLEX
DETAILED DESIGN IRRIGATION SYSTEM
EM
PH
SJ
12/05/2021
4-GRC-d2 18 A
BITS GOLF COURSE WATER SUPPLY - LAYOUT 1
15888-220 15
SCALE 1: SIZE A3SCALE 1: ORIGINAL SIZE
-2 0 2 4 6 8 10 20m
200 A1 400
IRR OPTIONS 1&22X OEM ROTOR PERFORMANCE
CONCEPTSFOR COMMENT & APPROVAL
LEGEND:
DN### HDPE PN12.5 LILAC MAIN PIPE - A
DN### HDPE PN12.5 LILAC LAT PIPE - A* (CONCEPT)
CONTROL WIRE ROUTE B, ## (NOT SHOWN) CONTROL WIRE ROUTE A, ## (NOT SHOWN)
PUMP: TYPE/SIZE ####
IRRIGATION CONTROLLER, TYPE ####
ISOLATION VALVE (DN## LINE SIZE) C/W 910 VB
DN50 AIR VALVE C/W 910VB (NOT SHOWN DN25 QCV C/W 910VB (NOT SHOWN)
BACKFLOW ASSEMBLY, TYPE/SIZE ####
WEATHER SENSOR, TYPE ####
DN## SOLENOID VALVE , TYPE ####
FILTER AUTO SCREEN, DN###, 200 MICRON
DN25/32 ROTOR A C/W SJR, MODEL ### FULL CIRCLE
DN### HDPE PN12.5 LILAC MAIN PIPE - B* (CONCEPT)
FLOW METER, TYPE/SIZE ####
LOW LEVEL SENSOR (NOT SHOWN)
DN## SOLENOID VALVE , TYPE #### * (CONCEPT)
DN25/32 ROTOR B C/W SJR, MODEL ### PART CIRCLE
TANK, TYPE/SIZE ####
RECYCLED WATER SIGN, TYPE/SIZE ####
DN### HDPE PN12.5 LILAC MAIN PIPE - C
DN### HDPE PN12.5 LILAC LAT PIPE - BDN### HDPE PN12.5 LILAC LAT PIPE - CPOWER CABLE & CONDUIT ROUTE (240-415V)
FOR ROTOR MODEL & NOZZLE REFER ROTOR TABLE, BASED ON SPACING
A 30/07/2021 EM SJ CONCEPTS - FOR COMMENT & APPROVAL
BITS CLUBS - WATER SUPPLY PUMP OPTION 3 (FOR ALTERNATIVE REFER INSERT OPTION 4)NEW SHED (9X4X2.7M) & PUMP SYSTEMCOMBINED GOLF (30 L/S*) + SPORTS FIELDS (10 L/S) PUMP UNIT & FILTER FOR BOTH AREASGRUNDFOS MPC 4X CRNE32-4-2 (11KW / 20FLA @ 415V EACH) 4X DUTY, Q= 40 L/S @ H=70M*AUTO FLUSH SCREEN FILTER , FILTAWORX FW200 (FULL 316SS), C/W 316SS BYPASS MANIFOLD &3X BUTTERFLY VALVESNOTE (*) GOLF PUMP/MAINS CAPACITY INCLUDES FUTURE 5 HOLES FOR TOTAL 18 HOLES, EXISTING13 HOLES DUTY OF Q= 22 L/S @ H=70M, THEREFORE DUTY FOR EXISTING COMBINED AREAS Q=32L/S @H=70M TO STAY WITH RECYCLED WATER INFLOW CAPACITY. INFLOW CAPACITY REQUIRESINCREASE WHEN GOLF COURSE IF EXTENDED BEYOND EXISTING AREAS (13 HOLES) NOMINATED
BITS CLUBS - WATER SUPPLY PUMP OPTION 4(FOR ALTERNATIVE REFER OPTION 3 - ON BASE DRAWING)NEW SHED (9X5X2.7M) & PUMP SYSTEMSEPARATE PUMP UNITS & FILTERS FOR GOLF & SPORTS FIELDSGOLF MPC 3X CRNE32-4-2 (11KW EACH) 3X DUTY*, Q= 30 L/S @ H=70MAUTO FLUSH SCREEN FILTER , FILTAWORX FW150EX (316SS) & BYPASSSPORTS MPC 2X CRNE15-4 (5.5KW EACH) 2X DUTY, Q= 10 L/S @ H=70MAUTO FLUSH SCREEN FILTER , FILTAWORX FW100EX (316SS) & BYPASSNOTE (*) GOLF CAPACITY FOR EXISTING 13 HOLES IS Q= 22 L/S @ H=70M,THEREFORE COMBINED FLOW CAPACITY Q= 32 L/S FOR EXISTING AREAS.
95
BITS CLUBS - WATER SUPPLY PUMP OPTION 5 - PART BPOTABLE WATER BACKUP FOR LIMITED CAPACITY AT Q=10 l/S INTO 46.4 KL TANK, IFRECYCLED WATER IS UNAVAILABLE FOR AN EXTENDED PERIOD.CLUB ALLOCATION ESTIMATES AT RESTRICTED PUMP OUT RATE OF 10L/S AS FOLLOWS;· GOLF - TEES & GREENS ONLY (UP TO 2HA ) : 2 NIGHTS / WEEK· AFL & CRICKET (1.8HA): 2 NIGHTS / WEEK· SOCCER (2HA): 2 X NIGHTS PER WEEKTHE CONCEPT IS TO ALLOW EACH CLUB TO APPLY AT LEAST 17MM/WEEK USING ANEXTENDED TIME WINDOW OF 9.5HR/NIGHT FOR BASIC MAINTENANCE IRRIGATION FOR ALIMITED PERIOD UNTIL RECYCLED WATER IS AVAILABLE. ONE SPARE NIGHT IS AVAILABLETO THE SPORTS CLUBS WHICH CAN BE BASED ON SEASONAL DEMAND & FIELD CONDITION
BITS CLUBS - WATER SUPPLY OPTION 5 - PART ACONNECT TO EXISTING POTABLE WATER SUPPLY WITH DN80
BACKFLOW ASSEMBLY & 110MM HDPE PIPE TO TANKNOMINAL DUTY: Q 10L/S @ H= 25M
DESIGN OPERATING TIME WINDOW FOR POTABLE: 8.30PM TO 6AM
POWER SUPPLYCONNECT TO EXISTING MAIN DISTRIBUTION BOARD TO SUB-BOARD IN SHEDTOTAL LOAD, PUMPS 44KW ~ 80A 415V PLUS CIRCUITS FOR 240V GENERAL POWER & LIGHTING.DECOMMISSION POWER SUPPLY TO EXISTING PUMP SHED (44KW CAPACITY, 80FLA @ 415V)
RECYCLED WATER SUPPLY - NEW SUCTION PIPE ROUTEREDIRECT EXISTING PIPE FROM NEAREST CONNECTION POINT, CONCRETE WELL.DECOMMISSION EXISTING PUMP SHED, POWER SUPPLY & CAP PUMP SUCTIONNEAREST TO THE NEW CONNECTION POINT. GRC TO PROVIDE AS-CONSTRUCTEDDRAWINGS OF RW PIPE FROM EXISTING TANKS WITH DETAILED PIPE SIZES.NOMINAL PEAK FLOW DEMAND 40 L/S FOR GOLF + SPORTS FEILD DEMANDCOMBINED, PROPOSED CONCEPT PIPE SIZING 280MM HDPE PN12.5 (LILAC) FORTOTAL FUTURE DEMAND (BITS 18 HOLES GOLF PLUS BITS SPORTS FIELDS)
BITS CLUBS - WATER SUPPLY PUMP OPTION 5 - PART BAS SHOWN & NOTES ON BASE DRAWING ABOVE
EXISTING DN100 POTABLEMETERED WATER SUPPLYC/W BACKFLOW ASSEMBLY.NOMINAL STATIC HEAD = 64M
49
7
7
R2.3
POTENTIAL TO REDUCE SHED TO ~ 8MBY OPTION TO WALL MOUNT PUMP
CONTROL PANEL, IF REQUIRED
POTENTIAL TO BLANK ONE PUMPBRANCH FOR FUTURE HOLES HOLES,
IF REQUIRED OR KEEP IN AS STANDBY
COMBINED GOLF + SPORTS PUMP UNIT GA - 4XCRNE32-4-2INCLUDES FUTURE OR STANDBY
NTS
GOLF ONLY PUMP UNIT GA - 3XCRNE32-4-2INCLUDES FUTURE OR STANDBY
NTS
SPORTS ONLY PUMP UNIT GA - 2XCRNE15-4NTS
316SS AUTO SCREEN FILTER - BY PASS NOT SHOWNDN200 COMBINED OR DN150 GOLF & DN100 SPORTS
NTS
DOSING:NO SPECIFIC ALLOWANCE HAS BEEN MADE AT THE CONCEPTSTAGE ON-SITE, OR AT STP, FOR ADDITIONAL WATER TREATMENTOR DOSING. POTENTIAL OPTIONS ARE ACID (pH), LIQUID CALCIUM(Na) & SURFACANTS (HW/HS). CHEMICAL STORAGE, BUNDING,SAFETY SHOWER & OPERATOR TRAINING TO BE CONSIDERED.GRC TO CONFIRM IF ANY SPECIFIC DOSING REQUIREMENT ON-SITE.
PRO
9
DAM
PS
T6
T10
13
CG
CLIENT:
PROJECT:
SHEET OFDRAWING No. REVISION
DES/DRAWN:
APPROVED:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
This document is and shall remain the property ofHYDRO-PLAN PTY. LTD. The document may onlybe used for the purpose for which it wascommissioned and in accordance with the terms ofengagement for the commission.
The arrangement and general details as shown onthis drawing are essentially diagrammatic and mustbe applied to the circumstances as found on site.
COPYRIGHT
SmartApprovedWaterMark
DRAFT REF:
CHECKED:
NORTH
Dra
win
g fil
e: D
:\Wat
erEt
\DW
G C
AD\H
P te
mp\
1588
BIT
S D
ENN
IS P
ARK
(tem
p D
dve
)\H
P up
d ge
o R
1\15
888-
200-
d2 -
Stan
dard
\158
88-2
00-B
ITS
GO
LF_I
RR
IGAT
ION
(d2)
.dw
g - 0
5/08
/202
1 8:
19 P
M O
rigin
al S
ize:
ISO
FU
LL B
LEED
A3
(420
.00
X 29
7.00
MM
)
DATE:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
http://hydroplan.com.au
SYDNEYADELAIDEPERTH BEIJINGBRISBANEMELBOURNE
GLADESTONE REGIONAL COUNCIL182-21 BITS CLUB SITE & DENNIS PARK SPORTS COMPLEX
DETAILED DESIGN IRRIGATION SYSTEM
EM
PH
SJ
12/05/2021
4-GRC-d2 18 A
BITS GOLF COURSE WATER SUPPLY - LAYOUT 2
15888-221 16
SCALE 1: SIZE A3SCALE 1: ORIGINAL SIZE
-2 0 2 4 6 8 10 20m
200 A1 400
IRR OPTIONS 1&22X OEM ROTOR PERFORMANCE
CONCEPTSFOR COMMENT & APPROVAL
LEGEND:
DN### HDPE PN12.5 LILAC MAIN PIPE - A
DN### HDPE PN12.5 LILAC LAT PIPE - A* (CONCEPT)
CONTROL WIRE ROUTE B, ## (NOT SHOWN) CONTROL WIRE ROUTE A, ## (NOT SHOWN)
PUMP: TYPE/SIZE ####
IRRIGATION CONTROLLER, TYPE ####
ISOLATION VALVE (DN## LINE SIZE) C/W 910 VB
DN50 AIR VALVE C/W 910VB (NOT SHOWN DN25 QCV C/W 910VB (NOT SHOWN)
BACKFLOW ASSEMBLY, TYPE/SIZE ####
WEATHER SENSOR, TYPE ####
DN## SOLENOID VALVE , TYPE ####
FILTER AUTO SCREEN, DN###, 200 MICRON
DN25/32 ROTOR A C/W SJR, MODEL ### FULL CIRCLE
DN### HDPE PN12.5 LILAC MAIN PIPE - B* (CONCEPT)
FLOW METER, TYPE/SIZE ####
LOW LEVEL SENSOR (NOT SHOWN)
DN## SOLENOID VALVE , TYPE #### * (CONCEPT)
DN25/32 ROTOR B C/W SJR, MODEL ### PART CIRCLE
TANK, TYPE/SIZE ####
RECYCLED WATER SIGN, TYPE/SIZE ####
DN### HDPE PN12.5 LILAC MAIN PIPE - C
DN### HDPE PN12.5 LILAC LAT PIPE - BDN### HDPE PN12.5 LILAC LAT PIPE - CPOWER CABLE & CONDUIT ROUTE (240-415V)
FOR ROTOR MODEL & NOZZLE REFER ROTOR TABLE, BASED ON SPACING
A 30/07/2021 EM SJ CONCEPTS - FOR COMMENT & APPROVAL
18
18
15
15
DISCONNECT SUCTION PIPE & POWERTO EXISTING PUMP SHED, MAKE SAFE
RW JUNCTION PIT, GRC TO PROVIDE AS-CONSTRUCTED DWG FILES FORRECYLED WATER PIPEWORK FROM EXISTING TANKS TO EXISTING PUMPS
CONNECT TO EXISTING RW PIPE & EXTEND NEW DN280HDPE PN12.5 TO SUCTION OF NEW PUMP UNIT/S
PG
5
PRO
T6
CLIENT:
PROJECT:
SHEET OFDRAWING No. REVISION
DES/DRAWN:
APPROVED:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
This document is and shall remain the property ofHYDRO-PLAN PTY. LTD. The document may onlybe used for the purpose for which it wascommissioned and in accordance with the terms ofengagement for the commission.
The arrangement and general details as shown onthis drawing are essentially diagrammatic and mustbe applied to the circumstances as found on site.
COPYRIGHT
SmartApprovedWaterMark
DRAFT REF:
CHECKED:
NORTH
Dra
win
g fil
e: D
:\Wat
erEt
\DW
G C
AD\H
P te
mp\
1588
BIT
S D
ENN
IS P
ARK
(tem
p D
dve
)\H
P up
d ge
o R
1\15
888-
200-
d2 -
Stan
dard
\158
88-2
00-B
ITS
GO
LF_I
RR
IGAT
ION
(d2)
.dw
g - 0
5/08
/202
1 8:
19 P
M O
rigin
al S
ize:
ISO
FU
LL B
LEED
A3
(420
.00
X 29
7.00
MM
)
DATE:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
http://hydroplan.com.au
SYDNEYADELAIDEPERTH BEIJINGBRISBANEMELBOURNE
GLADESTONE REGIONAL COUNCIL182-21 BITS CLUB SITE & DENNIS PARK SPORTS COMPLEX
DETAILED DESIGN IRRIGATION SYSTEM
EM
PH
SJ
12/05/2021
4-GRC-d2 18 A
BITS GOLF COURSE WATER SUPPLY - LAYOUT 3
15888-222 17
SCALE 1: SIZE A3SCALE 1: ORIGINAL SIZE
-2 0 2 4 6 8 10 20m
200 A1 400
IRR OPTIONS 1&22X OEM ROTOR PERFORMANCE
CONCEPTSFOR COMMENT & APPROVAL
LEGEND:
DN### HDPE PN12.5 LILAC MAIN PIPE - A
DN### HDPE PN12.5 LILAC LAT PIPE - A* (CONCEPT)
CONTROL WIRE ROUTE B, ## (NOT SHOWN) CONTROL WIRE ROUTE A, ## (NOT SHOWN)
PUMP: TYPE/SIZE ####
IRRIGATION CONTROLLER, TYPE ####
ISOLATION VALVE (DN## LINE SIZE) C/W 910 VB
DN50 AIR VALVE C/W 910VB (NOT SHOWN DN25 QCV C/W 910VB (NOT SHOWN)
BACKFLOW ASSEMBLY, TYPE/SIZE ####
WEATHER SENSOR, TYPE ####
DN## SOLENOID VALVE , TYPE ####
FILTER AUTO SCREEN, DN###, 200 MICRON
DN25/32 ROTOR A C/W SJR, MODEL ### FULL CIRCLE
DN### HDPE PN12.5 LILAC MAIN PIPE - B* (CONCEPT)
FLOW METER, TYPE/SIZE ####
LOW LEVEL SENSOR (NOT SHOWN)
DN## SOLENOID VALVE , TYPE #### * (CONCEPT)
DN25/32 ROTOR B C/W SJR, MODEL ### PART CIRCLE
TANK, TYPE/SIZE ####
RECYCLED WATER SIGN, TYPE/SIZE ####
DN### HDPE PN12.5 LILAC MAIN PIPE - C
DN### HDPE PN12.5 LILAC LAT PIPE - BDN### HDPE PN12.5 LILAC LAT PIPE - CPOWER CABLE & CONDUIT ROUTE (240-415V)
FOR ROTOR MODEL & NOZZLE REFER ROTOR TABLE, BASED ON SPACING
A 30/07/2021 EM SJ CONCEPTS - FOR COMMENT & APPROVAL
CLIENT:
PROJECT:
SHEET OFDRAWING No. REVISION
DES/DRAWN:
APPROVED:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
This document is and shall remain the property ofHYDRO-PLAN PTY. LTD. The document may onlybe used for the purpose for which it wascommissioned and in accordance with the terms ofengagement for the commission.
The arrangement and general details as shown onthis drawing are essentially diagrammatic and mustbe applied to the circumstances as found on site.
COPYRIGHT
SmartApprovedWaterMark
DRAFT REF:
CHECKED:
NORTH
Dra
win
g fil
e: D
:\Wat
erEt
\DW
G C
AD\H
P te
mp\
1588
BIT
S D
ENN
IS P
ARK
(tem
p D
dve
)\H
P up
d ge
o R
1\15
888-
200-
d2 -
Stan
dard
\158
88-2
00-B
ITS
GO
LF_I
RR
IGAT
ION
(d2)
.dw
g - 0
5/08
/202
1 8:
19 P
M O
rigin
al S
ize:
ISO
FU
LL B
LEED
A3
(420
.00
X 29
7.00
MM
)
DATE:
APRVDD.DWN REVISION DESCRIPTIONREV ISSUED
http://hydroplan.com.au
SYDNEYADELAIDEPERTH BEIJINGBRISBANEMELBOURNE
GLADESTONE REGIONAL COUNCIL182-21 BITS CLUB SITE & DENNIS PARK SPORTS COMPLEX
DETAILED DESIGN IRRIGATION SYSTEM
EM
PH
SJ
12/05/2021
4-GRC-d2 18 A
BITS GOLF COURSE WATER SUPPLY - LAYOUT 4
15888-223 18
SCALE 1: SIZE A3SCALE 1: ORIGINAL SIZE
-2 0 2 4 6 8 10 20m
200 A1 400
IRR OPTIONS 1&22X OEM ROTOR PERFORMANCE
CONCEPTSFOR COMMENT & APPROVAL
LEGEND:
DN### HDPE PN12.5 LILAC MAIN PIPE - A
DN### HDPE PN12.5 LILAC LAT PIPE - A* (CONCEPT)
CONTROL WIRE ROUTE B, ## (NOT SHOWN) CONTROL WIRE ROUTE A, ## (NOT SHOWN)
PUMP: TYPE/SIZE ####
IRRIGATION CONTROLLER, TYPE ####
ISOLATION VALVE (DN## LINE SIZE) C/W 910 VB
DN50 AIR VALVE C/W 910VB (NOT SHOWN DN25 QCV C/W 910VB (NOT SHOWN)
BACKFLOW ASSEMBLY, TYPE/SIZE ####
WEATHER SENSOR, TYPE ####
DN## SOLENOID VALVE , TYPE ####
FILTER AUTO SCREEN, DN###, 200 MICRON
DN25/32 ROTOR A C/W SJR, MODEL ### FULL CIRCLE
DN### HDPE PN12.5 LILAC MAIN PIPE - B* (CONCEPT)
FLOW METER, TYPE/SIZE ####
LOW LEVEL SENSOR (NOT SHOWN)
DN## SOLENOID VALVE , TYPE #### * (CONCEPT)
DN25/32 ROTOR B C/W SJR, MODEL ### PART CIRCLE
TANK, TYPE/SIZE ####
RECYCLED WATER SIGN, TYPE/SIZE ####
DN### HDPE PN12.5 LILAC MAIN PIPE - C
DN### HDPE PN12.5 LILAC LAT PIPE - BDN### HDPE PN12.5 LILAC LAT PIPE - CPOWER CABLE & CONDUIT ROUTE (240-415V)
FOR ROTOR MODEL & NOZZLE REFER ROTOR TABLE, BASED ON SPACING
A 30/07/2021 EM SJ CONCEPTS - FOR COMMENT & APPROVAL
RECYCLED WATER STORAGETANKS, CAPACITY 2X 46KL
EXISTING RECYCLED WATERSUPPLY INFRASTRUCRE
RECYCLED WATER SUPPLY CONTROL ENCLOSURERETAIN EXISTING PLC & SCADA INPUTS/OUTPUTS, INCL;TANK LEVEL(3), VALVE, FLOW METER.PLC LOGIC PUMP AT STP STARTS ON LEVEL SWITCHTHEN OPENS VALVE AT TANK
INFLOW FROM STPDUTY Q= 30 TO 35 L/S
GRC TO PROVIDE AS-CONSTRUCTED DWGFILES FOR RECYCLED WATER SUCTION PIPESTO EXISTING BITS PUMP SHED