180 mw power plant +++ - intecteammw+power+… · after that, and a ncnda, ... coal-fired power...

13
Anemonenweg 9 D-97084 Würzburg Tel.: +49 (0) 931 - 35990861 Fax: +49 (0) 931 - 35990862 Web. : www.intecteam.eu E-Mail: [email protected] JV-Team Service, Worldwide Trading in the Energy Business ----------------------------------------------------------------------------------------------------------------------------------- Website: www.intecteam.eu E-Mail: [email protected] For Sale Used: 180 MW Gas Turbine Power Plant Out Put +/- 180 MW Frequency 50 Hz Manufacture: 2000 Price: 15.000.000,- EUR Location: Europe

Upload: hakhanh

Post on 13-Mar-2018

227 views

Category:

Documents


8 download

TRANSCRIPT

Page 1: 180 MW Power Plant +++ - IntecteamMW+Power+… · After that, and a NCNDA, ... coal-fired power plant or communicate via e-mail. ... Microsoft Word - 180 MW Power Plant +++.docx

Anemonenweg 9 D-97084 Würzburg

Tel.: +49 (0) 931 - 35990861 Fax: +49 (0) 931 - 35990862

Web. : www.intecteam.eu E-Mail: [email protected]

JV-Team Service, Worldwide Trading in the Energy Business -----------------------------------------------------------------------------------------------------------------------------------

Website: www.intecteam.eu E-Mail: [email protected]

For Sale Used: 180 MW Gas Turbine Power Plant

• Out Put

+/- 180 MW

• Frequency

50 Hz

• Manufacture:

2000

• Price:

15.000.000,- EUR

• Location:

Europe

Page 2: 180 MW Power Plant +++ - IntecteamMW+Power+… · After that, and a NCNDA, ... coal-fired power plant or communicate via e-mail. ... Microsoft Word - 180 MW Power Plant +++.docx

Anemonenweg 9 D-97084 Würzburg

Tel.: +49 (0) 931 - 35990861 Fax: +49 (0) 931 - 35990862

Web. : www.intecteam.eu E-Mail: [email protected]

For sale: Used 180 MW Gas Turbine Power Plant

PLANT OVERVIEW

� COMBINED CYCLE POWER PLANT, CONSISTING IN: o N° 2 x AE64.3 GAS TURBINES o N° 1 x STEAM TURBINE o N° 3 x GENERATORS WY18Z

� 2+1 C.C. ARRANGEMENT SCHEME

� ROTATING EQUIPMENT MANUFACTURED BY ANSALDO ENERGIA; HRSG BOILERS BY FOSTER WHEELER

� COMMISSIONED BY ANSALDO ENERGIA IN THE YEAR 2000

� OVERHAULED BY ANSALDO ENERGIA o Gr 1 last MO 2010 @ 90,800 EOH o Gr 2 last MO 2012 @ 99,800 EOH

� IN OPERATION UNTIL APRIL 2015, CUMULATED EOH: o Gr 1 @ 111,000 EOH (ABOUT 5,000 EOH TO NEXT

OVERHAUL) o Gr 2 @ 113,000 EOH (ABOUT 12,000 EOH TO

NEXT OVERHAUL)

� COMBINED CYCLE POWER PLANT, CONSISTING IN:

• N° 2 x AE64.3 GAS TURBINES

• N° 1 x STEAM TURBINE

• N° 3 x GENERATORS WY18Z

� 2+1 C.C. ARRANGEMENT SCHEME

� ROTATING EQUIPMENT MANUFACTURED BY ANSALDO ENERGIA; HRSG BOILERS BY FOSTER WHEELER

� COMMISSIONED BY ANSALDO ENERGIA IN THE YEAR 2000

� OVERHAULED BY ANSALDO ENERGIA

• Gr 1 last MO 2010 @ 90,800 EOH

• Gr 2 last MO 2012 @ 99,800 EOH

� IN OPERATION UNTIL APRIL 2015, CUMULATED EOH:

• Gr 1 @ 111,000 EOH (ABOUT 5,000 EOH TO NEXT OVERHAUL)

• Gr 2 @ 113,000 EOH (ABOUT 12,000 EOH TO NEXT OVERHAUL)

Page 3: 180 MW Power Plant +++ - IntecteamMW+Power+… · After that, and a NCNDA, ... coal-fired power plant or communicate via e-mail. ... Microsoft Word - 180 MW Power Plant +++.docx

Anemonenweg 9 D-97084 Würzburg

Tel.: +49 (0) 931 - 35990861 Fax: +49 (0) 931 - 35990862

Web. : www.intecteam.eu E-Mail: [email protected]

For sale: Used 180 MW Gas Turbine Power Plant

Gas Turbines

� MANUFACTURER: ANSALDO ENERGIA

� TYPE: 64.3

� NR OF INSTALLED EQUIPMENT: 2

� NOMINAL SPEED: 3000 rpm (1)

� POWER OUTPUT: ABOUT 55 MW (2)

� EFFICIENCY: ABOUT 35 % (2)

� FUEL: NATURAL GAS

1. 5434 rpm REDUCED TO 3000 rpm BY REDUCTION GEARBOX

2. NEW & CLEAN @ ISO CONDITIONS (Ambient Pressure 1013 mbar; Ambient Temperature 15 °C; Relative Humidity 65%)

3. THE UNITS CAN BURN VARIOUS TYPES OF GASES AND OILS, BUT THE PRESENT CONFIGURATION IS NG-ONLY. EVENTUAL MODIFICATIONS TO COMBUSTION SYSTEM NEED A SPECIFIC ENGINEERING ACTIVITY AND VARIATIONS TO THE INVOLVED EQUIPMENT CONFIGURATION.

Gas Turbines

� MANUFACTURER: ANSALDO ENERGIA

� NR OF INSTALLED EQUIPMENT: 1

� NOMINAL SPEED: 3000 rpm

� POWER OUTPUT: UP TO 48 - 50 MW

� NR OF STAGES: 16

� INLET STEAM: 508 C @ 58.4 BAR

(1) DEPENDING ON OPERATING CONDITIONS

Page 4: 180 MW Power Plant +++ - IntecteamMW+Power+… · After that, and a NCNDA, ... coal-fired power plant or communicate via e-mail. ... Microsoft Word - 180 MW Power Plant +++.docx

Anemonenweg 9 D-97084 Würzburg

Tel.: +49 (0) 931 - 35990861 Fax: +49 (0) 931 - 35990862

Web. : www.intecteam.eu E-Mail: [email protected]

For sale: Used 180 MW Gas Turbine Power Plant

GENERATORS

� MANUFACTURER: ANSALDO ENERGIA

� TYPE: WY18Z-049LLT

� NR OF INSTALLED EQUIPMENT: 3

� NOMINAL POWER OUTPUT: 70000 kVA

� NOMINAL VOLTAGE: 11500 V

� NOMINAL CURRENT: 3514 A

� cosφ: 0,85

� COOLING: AIR

� EXCITER TYPE: STATIC

� FREQUENCY: 50 Hz

� NR OF POLES: 2

� NOMINAL SPED: 3000 rpm

GAS TURBINE & AUXILIARY SYSTEMS

Page 5: 180 MW Power Plant +++ - IntecteamMW+Power+… · After that, and a NCNDA, ... coal-fired power plant or communicate via e-mail. ... Microsoft Word - 180 MW Power Plant +++.docx

Anemonenweg 9 D-97084 Würzburg

Tel.: +49 (0) 931 - 35990861 Fax: +49 (0) 931 - 35990862

Web. : www.intecteam.eu E-Mail: [email protected]

For sale: Used 180 MW Gas Turbine Power Plant

GAS TURBINE GENERATOR LAYOUT (1) TYPICAL FOR 64.3 MODEL

Page 6: 180 MW Power Plant +++ - IntecteamMW+Power+… · After that, and a NCNDA, ... coal-fired power plant or communicate via e-mail. ... Microsoft Word - 180 MW Power Plant +++.docx

Anemonenweg 9 D-97084 Würzburg

Tel.: +49 (0) 931 - 35990861 Fax: +49 (0) 931 - 35990862

Web. : www.intecteam.eu E-Mail: [email protected]

For sale: Used 180 MW Gas turbine Power Plant

GAS TURBINE GENERATOR LAYOUT (1) TYPICAL FOR 64.3 MODEL

Page 7: 180 MW Power Plant +++ - IntecteamMW+Power+… · After that, and a NCNDA, ... coal-fired power plant or communicate via e-mail. ... Microsoft Word - 180 MW Power Plant +++.docx

Anemonenweg 9 D-97084 Würzburg

Tel.: +49 (0) 931 - 35990861 Fax: +49 (0) 931 - 35990862

Web. : www.intecteam.eu E-Mail: [email protected]

For sale: Used 180 MW Gas Turbine Power Plant

GAS TURBINE & GENERATOR LAYOUT (2) PLANT LAYOUT – VALID FOR EACH GAS TURBINE

GAS TURBINE & GENERATOR LAYOUT (3) PLANT LAYOUT – VALID FOR EACH GAS TURBINE

Page 8: 180 MW Power Plant +++ - IntecteamMW+Power+… · After that, and a NCNDA, ... coal-fired power plant or communicate via e-mail. ... Microsoft Word - 180 MW Power Plant +++.docx

Anemonenweg 9 D-97084 Würzburg

Tel.: +49 (0) 931 - 35990861 Fax: +49 (0) 931 - 35990862

Web. : www.intecteam.eu E-Mail: [email protected]

For sale: Used 180 MW Gas Turbine Power Plant

GAS TURBINE DIMENSION & WEIGHT (1) TYPICAL FOR 64.3 MODEL

GAS TURBINE DIMENSION & WEIGHT (2) TYPICAL FOR 64.3 MODEL

Page 9: 180 MW Power Plant +++ - IntecteamMW+Power+… · After that, and a NCNDA, ... coal-fired power plant or communicate via e-mail. ... Microsoft Word - 180 MW Power Plant +++.docx

Anemonenweg 9 D-97084 Würzburg

Tel.: +49 (0) 931 - 35990861 Fax: +49 (0) 931 - 35990862

Web. : www.intecteam.eu E-Mail: [email protected]

For sale: Used 180 MW Gas turbine Power Plant

STEAM TURBINE SHIPPING

TOTAL SHIPMENT WEIGHT 72500 kg (WITHOUT SLEDGE)

GENERATOR SHIPPING TYPICAL FOR WY18Z-049LLT TYPE

TOTAL SHIPMENT WEIGHT 1040 KN

Important Disclaimer Although the statements and technical information contained herein are believed to be materially accurate as of the date hereof, no representation or warranty is given as to the accuracy of any of the information provided. This document contains confidential information intended only for the use of the addressee. If you are not the intended recipient of this information then you are hereby notified that any use, dissemination, distribution or reproduction of this message is prohibited.

Page 10: 180 MW Power Plant +++ - IntecteamMW+Power+… · After that, and a NCNDA, ... coal-fired power plant or communicate via e-mail. ... Microsoft Word - 180 MW Power Plant +++.docx

Anemonenweg 9 D-97084 Würzburg

Tel.: +49 (0) 931 - 35990861 Fax: +49 (0) 931 - 35990862

Web. : www.intecteam.eu E-Mail: [email protected]

For sale: Used 180 MW Gas Turbine Power Plant

Photo documentation

Page 11: 180 MW Power Plant +++ - IntecteamMW+Power+… · After that, and a NCNDA, ... coal-fired power plant or communicate via e-mail. ... Microsoft Word - 180 MW Power Plant +++.docx

Anemonenweg 9 D-97084 Würzburg

Tel.: +49 (0) 931 - 35990861 Fax: +49 (0) 931 - 35990862

Web. : www.intecteam.eu E-Mail: [email protected]

For sale: Used 180 MW Gas Turbine Power Plant

Photo documentation

Page 12: 180 MW Power Plant +++ - IntecteamMW+Power+… · After that, and a NCNDA, ... coal-fired power plant or communicate via e-mail. ... Microsoft Word - 180 MW Power Plant +++.docx

Anemonenweg 9 D-97084 Würzburg

Tel.: +49 (0) 931 - 35990861 Fax: +49 (0) 931 - 35990862

Web. : www.intecteam.eu E-Mail: [email protected]

For sale: Used 180 MW Gas turbine Power Plant

Photo documentation

Page 13: 180 MW Power Plant +++ - IntecteamMW+Power+… · After that, and a NCNDA, ... coal-fired power plant or communicate via e-mail. ... Microsoft Word - 180 MW Power Plant +++.docx

Anemonenweg 9 D-97084 Würzburg

Tel.: +49 (0) 931 - 35990861 Fax: +49 (0) 931 - 35990862

Web. : www.intecteam.eu E-Mail: [email protected]

For sale: Used 180 MW Gas Turbine Power Plant

For transportation and erection we can recommend you experienced companies, if you are in need of. These costs are in addition to the purchase price. If you are interested, we need a Letter of Interest, a Proof of Funds, a confirmation of our commission, and the name of the country of destination. After that, and a NCNDA, you will get further information, and we can arrange a visit (inspection) at the place of storage. If you agree, I will send you the address of the owner. So you can communicate with the owner of the coal-fired power plant or communicate via e-mail. We look forward to your reply

Important Disclaimer

Although the statements and technical information contained herein are believed to be materially accurate as of the date hereof, no representation or warranty is given as to the accuracy of any of the information provided. This document contains confidential information intended only for the use of the addressee. If you are not the intended recipient of this information then you are hereby notified that any use, dissemination, distribution or reproduction of this message is prohibited.

Confidentially & special references 1) This communication is confidential. The news sent by us has in principle no right binding explanations. The electronic message (including any attachments) contains confidential information and may be privileged or otherwise protected from disclosure. The information is intended to be for the use of the intended addressee only. Please be aware that any disclosure, copy, distribution or use of the contents of this message is prohibited. If you have received this e-mail in error please notify us immediately by reply e-mail and delete this message and any attachments from your system. If you are not one of the intended recipients, please notify the sender immediately, and destroy this email; you must not copy, distribute or take any action in reliance upon it. 2) Whilst all efforts are made to safeguard Inbound and Outbound e-mails, Intecteam cannot guarantee that attachments are Virus-free or compatible with your systems and does not accept any liability in respect of viruses or computer problems experienced. 3) In the case of competition or other/similar problems, we ask you to avoid unnecessary litigation and costs, contact us in advance. The cost of a legal notices without prior contact with us is rejected (§254 para. 2 BGB) as ill-founded within the meaning of the duty to mitigate damages.