2009 Ductless Mini Splits. “Affordable Comfort”. Quietside Mini Splits . Cooling Only Single Zone High Wall 9,000 to 24,000 Btu/h – 13 SEER Heat Pump Single Zone High Wall 9,000 to 24,000 Btu/h – 13 SEER & 7.7 HSPF Heat Pump Dual Zone High Wall - PowerPoint PPT Presentation

TRANSCRIPT

2009 Ductless Mini Splits

“Affordable Comfort”

Quietside Mini Splits • Cooling Only Single Zone High Wall

9,000 to 24,000 Btu/h – 13 SEER

• Heat Pump Single Zone High Wall9,000 to 24,000 Btu/h – 13 SEER & 7.7 HSPF

• Heat Pump Dual Zone High Wall 2 x 9,000 Btu/h & 2 x 12,000 Btu/h – 15 SEER & 7.7 HSPF

Single Zone Cooling Only• QSCE 091, 121, 181 &

241 Model series• 13 SEER efficiency• Low Noise levels• Small Indoor and Outdoor

unit footprints• 50ft line set lengths• 20ft vertical separation

included• Hi Voltage Power and

Control wiring required between Outdoor and Indoor units

Single Zone Cooling Only • Wireless Remote control

with Auto, Cool, De-hum, Fan modes and Auto Restart features

• Flare refrigerant connections

• Environmentally friendly R410A refrigerant

• 5/16” Gauge access port to differentiate for R410A refrigerant – NEEDS an adaptor #R410A-ADPT

C/O Specifications QSCE-091 QSCE-121 QSCE-181 QSCE-241

Nominal Btu/h 9,000 12,000 18,000 22,000

SEER 13 13 13 13

Voltage 115V-1Ph-60Hz 115V-1Ph-60Hz 208/230V-1Ph-60Hz 208/230V-1Ph-60Hz

Breaker Size (A) 15A 15A 20A 25A

RLA (A) 6.7A 8.8A 5.3A 8.6A

Indoor Unit QSCE-091 QSCE-121 QSCE-181 QSCE-241

Airflow Hi Speed (CFM) 360 400 610 765

Noise Level (Db) 42 45 45 48

Width (Inches) 30 7/8" 35 1/4" 42 1/8" 48 7/8"

Depth (Inches) 6 7/8" 6 7/8" 8 7/8" 8 7/8"

Height (Inches) 11" 11" 12 3/4" 12 3/4"

Unit Weight (lbs) 9lbs 14lbs 18lbs 20lbs

Outdoor Unit QSCC-091 QSCC-121 QSCC-181 QSCC-241

Noise Level (Db) 55 55 60 62

Width (Inches) 31 3/8" 33 1/2" 34 1/4" 34 1/4"

Depth (Inches) 8 7/8" 8 7/8" 11 3/8" 11 3/8"

Height (Inches) 21 3/8" 24" 33 1/2" 33 1/2"

Unit Weight (lbs) 31lbs 48lbs 62lbs 65lbs

Line Sets        

Ref Pipe Sizes (Inches) 1/4" & 1/2" 1/4" & 1/2" 3/8" & 5/8" 3/8" & 5/8"

Maximum Length (ft) 50ft 50ft 50ft 50ft

Max Vertical Sep (ft) 20ft 20ft 20ft 20ft

Factory Charge for (ft) 25ft 25ft 25ft 25ft

Addl Charge (oz/ft) 0.3oz/ft 0.3oz/ft 0.5oz/ft 0.5oz/ft

Single Zone Heat Pump • QSHE 091, 121, 181 &

241• 13 SEER and 7.7 HSPF

efficiency• 50ft Line Set length• 20ft Vertical Separation

included• Demand defrost initiated

by Outdoor unit coil temperature sensor

• Capillary expansion devices are located in Outdoor unit

Single Zone Heat Pump • Auto swing feature on air

direction louvers • High Efficiency Toshiba

Rotary compressors• Environmentally friendly

R410A refrigerant • Flare connections on

Indoor and Outdoor unit, gauge access is also 5/16”

• Low Noise levels, especially for the Outdoor units

Specifications QSHE-091 QSHE-121 QSHE-181 QSHE-241Nom Cool/Heat Btu/h 9,000/9,000 12,000/12,000 18,000/17,000 22,000/24,000

SEER 13 13 13 13

HSPF 7.7 7.7 7.7 7.7

Voltage 115V-1Ph-60Hz 115V-1Ph-60Hz 208/230V-1Ph-60Hz 208/230V-1Ph-60Hz

Breaker Size (A) 15A 15A 20A 25A

RLA (A) 6.9A 9.0A 5.5A 8.6A

Indoor Unit QSHE-091 QSHE-121 QSHE-181 QSHE-241

Airflow Hi Speed (CFM) 360 400 610 765

Noise Level (Db) 42 45 45 48

Width (Inches) 30 7/8" 35 1/4" 42 1/8" 48 7/8"

Depth (Inches) 6 7/8" 6 7/8" 8 7/8" 8 7/8"

Height (Inches) 11" 11" 12 3/4" 12 3/4"

Unit Weight (lbs) 9lbs 14lbs 18lbs 20lbs

Outdoor Unit QSHC-091 QSHC-121 QSHC-181 QSHC-241

Noise Level (Db) 55 55 60 62

Width (Inches) 31 3/8" 33 1/2" 34 1/4" 34 1/4"

Depth (Inches) 8 7/8" 8 7/8" 11 3/8" 11 3/8"

Height (Inches) 21 3/8" 24" 33 1/2" 33 1/2"

Unit Weight (lbs) 31lbs 48lbs 62lbs 65lbs

Line Sets        

Ref Pipe Sizes (Inches) 1/4" & 1/2" 1/4" & 1/2" 3/8" & 5/8" 3/8" & 5/8"

Maximum Length (ft) 50ft 50ft 50ft 50ft

Max Vertical Sep (ft) 20ft 20ft 20ft 20ft

Factory Charge for (ft) 25ft 25ft 25ft 25ft

Addl Charge (oz/ft) 0.3oz/ft 0.3oz/ft 0.5oz/ft 0.5oz/ft

Dual Zone Heat Pump • QSHD 181 and 241• 2 x 9,000 Btu/h and 2 x

12,000 Btu/h systems• SINGLE Inverter drive

compressor provides refrigerant flow for both Indoor units

• Up to 15.6 SEER and 8.1 HSPF

• Units can operate independently but one unit cannot be in Heating when the other is in cooling

Dual Zone Heat Pump • 50ft max line set including a

vertical separation of 20ft to each Indoor unit

• R410A refrigerant• Cooling operation down to

32 DegF ambient• Heating operation down to 5

DegF• Inverter Drive compressor

controls capacity based on Indoor unit operation, set points, ambient temperature and Indoor coil temperatures

Dual Zone - Outdoor • Electronic Expansion

Valves control refrigerant flow to each Indoor unit providing precise control across all conditions

• Inverter Drive compressor is covered in a blanket to reduce noise levels

• System uses demand defrost, with both units having to defrost at the same time even if one does not need it

Dual Zone Outdoor • 24k system uses a

manifold style connection with a single set of service valves, the 18k unit has dual service valves

18k

24k

24k

Dual Zone • SINGLE wire low

voltage communication signal between Indoor units and Outdoor units Separation required to the high voltage power wiring

• Multiple fault codes displayed on the Indoor units

Specifications QSHD-181 QSHD-241Nom Cooling Btu/h per Indoor Unit 9,000 12,000SEER 15.6 14.2Modulation range in Cooling per Indoor unit (Btu/h) 3,500 - 11,500 5,000 - 14,500Nom Heating Btu/h per Indoor Unit 11,000 12,500HSPF 8.1 7.9Modulation range in Heating per Indoor unit (Btu/h) 4,750 - 12,000 4,750 - 13,500Voltage Breaker Size (A) 20A 20ARLA Cool/Heat (A) 10.5/9.8A 13/13.7A

Indoor Unit QSIHD-091 QSIHD-121Airflow Hi/Med/Low Speed (CFM) 350/300/200 460/400/220Noise Level Hi Speed (Db) 42 45Width (Inches) 31 1/8" 36 5/8"Depth (Inches) 8 1/4" 8 1/4"Height (Inches) 10 5/8" 10 7/8"Unit Weight (lbs) 26lbs 31lbs

Outdoor Unit QSOHD-181 QSOHD-241Noise Level (Db) 57 57Width (Inches) 36 1/2" 35 1/2"Depth (Inches) 14 1/4" 13"Height (Inches) 27 5/8" 32"Unit Weight (lbs) 154lbs 163lbs

Line SetsRefrigerant Ref Pipe Sizes to each Indoor unit (Inches) 1/4" & 3/8" 1/4" & 1/2"Maximum Length to each Indoor unit (ft) 50ft 50ftMax Vertical Sep to each Indoor unit (ft) 20ft 20ftFactory Charge for (ft) 25ft 25ftAddl Charge (oz/ft) 0.3oz/ft 0.3oz/ft

ControlsControl MethodCommunication Control Voltage

CertificationSafetyPerformance

Options Refrigerant Line Sets 25ft ILS2506, 50ft ILS5006 25ft ILS2507, 50ft ILS5007Condensate Pumps ASP-MO-230 ASP-MO-230

All performance shown is at ARI 210/240 conditionsETL & ETLc

Wireless Remote control with a temp sensor in each Indoor Unit

208-230V-1Ph-60Hz

208/230V

R410A

Accessories • Line Sets for Single

zones – 25ft and 50ft lengths, both lines are insulated and include 14-7 Interconnecting wire

• Interconnecting Wire, 14-7

• 5/16” Adaptor to access Refrigerant circuit

Accessories

• Line Sets for Dual zones – 25ft and 50ft lengths, both lines are insulated and include 14-3 and 16-2 Shielded Interconnecting wire

• 2 Line Sets needed per system

Accessories• Low Ambient Control

MANDATORY for all Quietside unit Data Room applications or when using cooling below 65 DegF Ambient

• Condensate Pump for unit installations on interior walls – Pumps are available in several styles with and without covers

• Condenser Brackets

Other items to sell with a Ductless

• Line Set covers, Quietside recommends the Slimduct covers

• Condenser Pad• Electrical Disconnect and Whip• Condenser feet/risers• Condensate Hose extension and/or trap for

humid areas, we recommend rigid piping whenever draining condensate anything but vertical

Quietside Unit Warranty

• 5 Years Compressor• 1 Year all other parts, including

refrigeration system parts• 90 Days limited labor from date of start up

• All warranties commence on date of installation

• Warranty parts are shipped ground on receipt of a completed warranty claim form

Thanks for listening Any Questions???