217A Multiparameter Patient Simulator 217A Multiparameter Patient Simulator The 217A Multiparameter Patient Simulator has been labeled solid and dependable by satisfied users worldwide. This “veteran" is quite popular with customers requiring a comprehensive and portable multiparameter patient simulator. This product has been discontinued. This product has been discontinued. Service and repair is guaranteed until October 17, 2011. Service and repair is guaranteed until October 17, 2011. We recommend the We recommend the in place of this product. in place of this product. Standard Accessories Miscellaneous Accessories Miscellaneous Accessories Controller/Co Simulator 217A-21A, Controller/Co Simulator (part# 2246913)(for use with 217A) 9530-0019FG 9530-0019FG Overlay kit (part# 2392790)(for use with 21A Controller for 217A) Cables (IBP) Cables (IBP) 3010-0048FG 3010-0048FG unterminated UU-1 BP cable (part# 2392173)

Upload: others

Post on 11-Apr-2022

16 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 217A Multiparameter Patient Simulator

217A Multiparameter Patient Simulator217A Multiparameter Patient SimulatorThe 217A Multiparameter Patient Simulator has been labeled solid and dependable by satisfied users worldwide. This “veteran" is quite popular with customersrequiring a comprehensive and portable multiparameter patient simulator.

This product has been discontinued. This product has been discontinued. Service and repair is guaranteed until October 17, 2011.Service and repair is guaranteed until October 17, 2011. We recommend the We recommend the in place of this product.in place of this product.

Standard Accessories

Miscellaneous AccessoriesMiscellaneous Accessories

Controller/Co Simulator

217A-21A, Controller/Co Simulator (part# 2246913)(for use with 217A)

9530-0019FG

9530-0019FG Overlay kit (part# 2392790)(for use with 21A Controller for 217A)

Cables (IBP)Cables (IBP)

3010-0048FG

3010-0048FG unterminated UU-1 BP cable (part# 2392173)

Page 2: 217A Multiparameter Patient Simulator

3010-0076

3010-0076 TK-1 (6M) BP Cable (part# 2198879)

3010-0110

HP-3 BP cable (12M 5\u00b5V) 120 in, Mini-DIN to 12 pin HP/PH (part# 2198902)

3010-0111

3010-0111 HP-4 BP cable (12M 40\u00b5V) (part# 2198916)

3010-0114

Siemens-SM-1, BP cable

3010-0115

3010-0115 Mennen Medical MM-1 (6M) (6-pin) (part# 2198933)

3010-0116

3010-0116 PC-1 BP cable (6M) (6-pin) (part# 2198940)

3010-0122

3010-0122 GE Marquette Medical MQ-2 (8M round) (7-pin) (part# 2198978)

3010-0208

Nihon Kohden-NK-1 BP cable (5M) (5-pin) (part# 2462263)

3010-0248

QM-1 (6M) Blood pressure cable (10-pin orange) (part# 2198925)

3010-0308

Unterminated BP cable 4100-01 (part# 2199393)(7-pin DIN, one end only)

3010-0357

GE Marquette Medical MQ-3 BP cable (rectangular -11 M) (part# 2199627)

3010-0366

3010-0366 SM-3 BP cable (15M) (part# 2199666)

3010-0584

Page 3: 217A Multiparameter Patient Simulator

3010-0584 DX-1 BP cable (10F) (10-pin) (part# 2200955)

CablesCables

11451

E-input meas. Cable 2M, black

3010-0117 (part number)

SpaceLabs (ALPHA9/703R) SL-1 (5M) BP Cable

3010-0120

LT-1 BP cable - (intrauterine pressure – 10M) (part# 2198969)

Provides interface with the following:

Airshields (Fetascan 1400)Advanced Medical Systems (FM 660, FM 670)

3010-0206 (part number)

Kontron Medical (Mini-, Super-, Color-Mon series) KT-1 (6M) BP Cable

3010-0284

3010-0284 COA-1 Cardiac output adapter (part# 2199240)

4100-04 HP cable (12M)

Hewlett Packard 5\u00b5V (78300, -500, -800, and Merlin/Viridia/Omnicare) 4100-04 (12 meter)

HP/Philips HP-9 BP cable

HP/Philips (8040A) HP-9 (intrauterine pressure only – 12M 5 \u00b5V) BP Cable

3010-0377

3010-0377 DS-A IABP Sync Datascope (part# 2199747)(for use with 217A/medSim 300B)

3010-0386FG

3010-0386FG CI-2B Interface Cable (part# 2392224)(for use with 21A Controller to 217A)

3010-0441

Interface cable, medTester to IDA 4 Plus (without wedge adapter) (RS-232; female DB9 to female DB25) (part# 2200102) (medTester toSigmaPace\™1000/PC/Index 2XL/IDA 4 Plus [IDA 4 to wedge requires cable# 2201042]; Impulse 4000 to PC)

Page 4: 217A Multiparameter Patient Simulator

Carrying CasesCarrying Cases

9530-0062

9530-0062, Multipurpose Hard-Sided Watertight Carrying Case 1400 (part# 2248546)(for use with 217A)

9530-0064

Multipurpose Hard-Sided Watertight Carrying Case (part# 2248568)(contains “pick & pluck” foam) (17” L x 11 \u00be” W x 6” H)

Patient Monitor SimulatorsPatient Monitor Simulators

PT MONITOR W/ECG/RESP/BP/TEMP(ZOLL)

SIM TEST SET USA,TEST SET

217A-multiparameter-patient-simulator217A-multiparameter-patient-simulator

ECG GeneralECG General

Lead Configuration:Lead Configuration:

12-lead ECG with nine independent outputs for each signal leadreferenced to RL

Output Update Rate:Output Update Rate:

2 ms

Output Impedance:Output Impedance:

1000 \u03a9 to RL

1 V Output:1 V Output:

Lead II at 1 V peak

Amplitude Accuracy:Amplitude Accuracy:

5 % 2 Hz square wave at 1 mV p-p (Lead II)

Normal Sinus RhythmNormal Sinus Rhythm

Rates:Rates:

30, 60, 80, 120, 160, 200, 240, and 300 BPM

Page 5: 217A Multiparameter Patient Simulator

Amplitudes:Amplitudes:

0.5, 1.0, 1.5, 2.0 mV (Lead II)

ST Segment:ST Segment:

0.05, 0.10, 0.15, 0.20, 0.50, and 0.80 mV (positive and negativepolarity)

Axis Deviation:Axis Deviation:

Normal, horizontal, and vertical

Pediatric ECG:Pediatric ECG:

40 ms R-Wave width

ECG PerformanceECG Performance

Square Wave:Square Wave:

2 Hz at 1 mV bipolar

Pulse:Pulse:

4 s at 1 mV

Sine Waves:Sine Waves:

10, 40, 50, 60, and 100 Hz at 1 mV

Triangle Wave:Triangle Wave:

2 Hz and 3 mV

ArrhythmiasArrhythmias

Selections:Selections:

45 total ventricular, supraventricular, premature, conduction, andpacemaker

Base Rhythm:Base Rhythm:

80 BPM, 1.0 mV/Lead II

Pacemaker Spike Duration:Pacemaker Spike Duration:

0.15 ms

Pacemaker Spike Amplitude:Pacemaker Spike Amplitude:

4.8 mV on lead II, 2.4 mV on leads I and III and V1-V6, 5 %

Output ConnectorsOutput Connectors

High Level:High Level:

0.25 in standard phone jack

Low Level:Low Level:

Ten AHA (American Heart Association) or European (IEC) color-coded binding posts (as ordered)

Binding posts compatible with disposable snaps and 3.2 or 4.0 mmelectrodes

TemperatureTemperature

Page 6: 217A Multiparameter Patient Simulator

TemperatureTemperature

Channel One:Channel One:

Fixed at 37 \u00b0C/98.6 \u00b0F

Channel Two:Channel Two:

30 \u00b0C / 86 \u00b0F; 37 \u00b0C / 98.6 \u00b0 F; 40\u00b0C / 104 \u00b0F (selectable)

Temp Probe Compatibility:Temp Probe Compatibility:

400/700 YSI series

Accuracy:Accuracy:

0.25 \u00b0C

ArtifactArtifact

ECG:ECG:

50 Hz, 60 Hz, muscle and baseline wander. Any single artifact can beadded to the ECG selection at three different levels to all or to anysingle-signal lead.

BP/Respiration:BP/Respiration:

Two pressure values in phase with respiration can be injected intoall BP channels. Arterial and LV waveforms are modulated at theselected respiratory rate. All right-heart waveforms have therespiration offset signal added to the output.

RespirationRespiration

Baseline Impedances:Baseline Impedances:

500 \u03a9 or 1000 \u03a9

Impedance Variations:Impedance Variations:

0.0, 0.1, 0.2, 0.5, 1.0, and 3.0 \u03a9

Rates:Rates:

15, 20, 30, 40, 60, and 120 BrPM

Apnea:Apnea:

Continuous (off), momentary, 12 s. and 32 s

Ventilator Simulation:Ventilator Simulation:

Rate 40 BPM, delta impedance 3 \u03a9

Output Configuration:Output Configuration:

Lead I, lead II / RL-LL

Blood Pressure (Three Channels)Blood Pressure (Three Channels)

Input /Output Impedance:Input /Output Impedance:

300 \u03a9

Exciter Input Voltage Range:Exciter Input Voltage Range:

2 to 10 V

Page 7: 217A Multiparameter Patient Simulator

Exciter Input Frequency Range:Exciter Input Frequency Range:

DC to 4000 Hz

Transducer Sensitivity:Transducer Sensitivity:

5 to 40 uV/V/mmHg

Level Accuracy:Level Accuracy:

1 % of range + 1 % of setting + 1 count

Calibrated Rate:Calibrated Rate:

80 BPM

Waveform Update Rate:Waveform Update Rate:

10 ms

BP Selections:BP Selections:

Dynamic (mmHg):Dynamic (mmHg):

BP1BP1ATM(0)Arterial (120/80)Left ventricle (120/0)Right ventricle (25/0)Pulmonary artery (25/10)PA wedge (10/2)

BP2BP2ATM (0)Central venous pressure (15//10)Right ventricle (25/0)Pulmonary artery (25/10)PA wedge (10/2)

BP3BP3

Simulates a Swan-Ganz catheterization procedure, including right-heart navigation, and balloon inflation/deflation and removal

Static (mmHg):Static (mmHg):

BP1BP1

ATM (0), 10, 20, 40, 80, 100, 200, 250, and 300

BP2BP2

5, 10, 20, and 30

BP3BP3

(No static level selections)

Arrhythmia SelectionsArrhythmia Selections

SupraventricularSupraventricularAtrial fibrillation 1Atrial fibrillation 2Atrial flutter

Sinus arrhythmia

Page 8: 217A Multiparameter Patient Simulator

Sinus arrhythmiaMissed beat 80 BPMMissed beat 120 BPMParoxysmal atrial tachycardia (PAT)NodalSupraventricular tachycardia

Premature beatsPremature beatsAtrial (PAC)Nodal (PNC)PVC 1 StandardPVC 1 EarlyPVC 1 R on TPVC 2 StandardPVC 2 EarlyPVC 2 R on TMultifocal PVCs

Conduction defectsConduction defectsFirst degreeSecond-degree type 1Second-degree type 2Third degreeRight-bundle-branch blockLeft-bundle-branch block

Ventricular rhythmsVentricular rhythmsPVCs 6/minutePVCs 12/minutePVCs 24/minuteFrequent multifocal PVCs 20/minBigeminyTrigeminyPair PVCsRun of 5 PVCsRun of 11 PVCsVentricular tachycardiaV-Fibrillation (fine)V-Fibrillation (coarse)Dying heart complex (EMD)Asystole

Pacemaker (transvenous)Pacemaker (transvenous)AsynchronousDemand with frequent sinus beatDemand with occasional sinus beatAV sequentialNoncaptureNonfunction

Defibrillator TrainingDefibrillator Training

Emergency 1:Emergency 1:

Normal Sinus Rhythm (NSR) with PVC activity terminating into V-FIB

Emergency 2:Emergency 2:

NSR with a run of five PVCs terminating into V-FIB

Cardioversion:Cardioversion:

Page 9: 217A Multiparameter Patient Simulator

Atrial fibrillation is output until defibrillator is discharged, at whichpoint conversion to NSR will occur if properly synchronized with theR-Wave. If the discharge is not synchronized, the ECG output willdegrade to V-FIB. Emergency defibrillation must then be performedto achieve conversion to NSR.

Intra-Aortic Balloon Assist Pump (IABP) SimulationIntra-Aortic Balloon Assist Pump (IABP) Simulation

Demonstrates the interactive simulation of the patient and the IABP.Synchronization signal from the IABP augments the simulated arterialpressure waveform.

Available ECG Simulations:Available ECG Simulations:

Normal sinus rhythm(30, 60, 80, and 120 BPM)Atrial fibrillationPremature ventricular contraction (PVCs 6/min)Asynchronous pacemaker (75 BPM)Run of five PVCsRun of eleven PVCs

CaseCase

High-impact polystyrene

PowerPower

9 V alkaline battery or battery eliminator (115 V or 230 V available)

DimensionsDimensions

7.5 in L x 5.4 in W x 1.8 in H (19.0 cm L x 13.8 cm W x 4.4 cm H)

WeightWeight

2 lb (0.9 kg)