22-1807-07 product data - · pdf file©2012 trane pub. no. 22-1807-07 product data...

28
© 2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

Upload: trinhnga

Post on 30-Jan-2018

229 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

© 2012 Trane Pub. No. 22-1807-07

Product Data4WCZ6036A through 4WCZ6060ASingle Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 TonR-410A

22-1807-07

Page 2: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

2

It's Hard to Stop a Trane.Single Packaged Electric Heat Pump SystemTrane offers a complete family of electric heat pump heating and cooling sys-tems, designed to keep you comfortable all year long, regardless of the weath-er, while keeping your operating costs as low as possible. A heat pump oper-ates efficiently as both an air conditioner and a heater. In the summer, the heat pump cools your home just like any other air conditioner by pulling the heat from the inside and releasing it outdoors. In the winter, it captures the heat that is always present in the outdoor air and transfers it indoors.

Introducing the new TRANE Single Packaged Electric Heat Pump System.

Single Packaged Electric Heat Pump Systems are easy and versatile to install. Because cooling and heating functions are all contained in a single cabinet, a Trane packaged heat pump system is easy to install and service. It can be flush mounted beside your home at ground level or placed on the roof for horizontal or downflow installation. When connected to an optional Trane thermo-stat control and air distribution ducts, you have a highly efficient, total home comfort system.

Single Packaged Electric Heat Pump Systems are unmatched in quality and reliability. All major components on these products, including the com-pressor, have been designed and manu-factured for maximum service. Every Climatuff® compressor is designed and manufactured to exacting specifications. Each design is life tested in extreme en-vironments to ensure reliable and long lasting operation in normal applications. Each compressor has internal motor protection for added reliability.

Page 3: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

3

Contents

Optional Equipment Listing 4

General Data 5

Heater Data 8

SPEK Data 9

Performance Data

Indoor Blower 12

Typical Wiring 14

Optional Equipment 16

Dimensional Data 22

Mechanical Specifications 27

Page 4: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

4

Optional EquipmentOPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [✓] indicates accessories included)

Hinged Filter Access Door (4WCZ6036) 0 ......................................................................... BAYACCDOR1A[ ]Hinged Filter Access Door (4WCZ6048-060) 0 .................................................................. BAYACCDOR2A[ ]Roof Curb Full Perimeter (4WCZ6036A) 3 .........................................................................BAYCURB050A[ ]Roof Curb Full Perimeter (4WCZ6048-060A) 3 ..................................................................BAYCURB051A[ ]Roof Curb Utility Extension Kit (BAYCURB050A) ......................................................................BAYUTIL101B[ ]Roof Curb Utility Extension Kit (BAYCURB051A) ......................................................................BAYUTIL102B[ ]0-25% Motorized Outside Air Damper (4WCZ6036) ............................................................BAYDMPR101A[ ]0-25% Motorized Outside Air Damper (4WCZ6048-060) .....................................................BAYDMPR102A[ ]Outside Air Control for V.S. Economizer (4WCZ6036-060A) 9 .............................................BAYOSAC001B[ ]0-25% Manual Fresh Air Damper (4WCZ6036A) 1. ..............................................................BAYOSAH001A[ ]0-25% Manual Fresh Air Damper (4WCZ6048-060A) 1. .......................................................BAYOSAH002A[ ]16" Round Duct Adapter (2 per box) (4WCZ6036A) 6 ........................................................ BAYSQRD001A[ ]18" Round Duct Adapter (2 per box) (4WCZ6024-060A) 6 ................................................. BAYSQRD002A[ ]0-100% Mod Economizer w/Baro. Relief (4WCZ6036A) 124 ........................................... BAYECON103A[ ]0-100% Mod. Economizer w/Baro. Relief (4WCZ6048-060A) 124. ................................... BAYECON104A[ ]0-100% Horizontal Economizer (4WCZ6036A) 12 . ........................................................... BAYECON203A[ ]0-100% Horizontal Economizer (4WCZ6048-060A) 12 . .................................................... BAYECON204A[ ]Economizer Relay Kit (required for Heat Pump applications) ..................................................BAYRLAY006A[ ] Enthalpy Control for Economizer (solid state). ........................................................................BAYENTH001A[ ]Remote Potentiometer (All-BAYECON***A) ...............................................................................BAYSTAT023[ ]1"-2" Filter Frame (4WCZ6036A) (20 x 25 filter not included) 1. ............. BAYFLTR101B[ ]1"-2" Filter Frame (4WCZ6048-060A) (20 x 20,20X18 filter not included) 1. ....... BAYFLTR201B[ ]Evaporator Defrost Control (Low Ambient Cooling) Kit 5. .....................................................BAYLOAM011A[ ]Head Pressure Control (Low Ambient Cool) (208/240v) Kit 5. .............................................BAYLOAM105A[ ] Crankcase Heater Scroll (4WCZ6036,048A1/3,060A1/3)(230v) 5. .......................................BAYCCHT102A[ ]Crankcase Heater Scroll (4WCZ6036-060A3)(460v) 5. ........................................................BAYCCHT404B[ ]Adapter Curb 4WCZ6036A to BAYCURB030,38................................................................... BAYADAP050A[ ] Adapter Curb 4WCZ6036A to BAYCURB033........................................................................ BAYADAP051A[ ] Adapter Curb 4WCZ6048-060A to BAYCURB030,38 ........................................................... BAYADAP052A[ ] Adapter Curb 4WCZ6048-060A to BAYCURB033 ................................................................ BAYADAP053A[ ] Adapter Curb 4WCZ6048-060A to BAYCURB034 ................................................................ BAYADAP054A[ ]12" Duct Shroud Covers Horizontal 4WCZ6036-060A7. .......................................................BAYCOVR112A[ ]18" Duct Shroud Covers Horizontal 4WCZ6036-060A 7. ......................................................BAYCOVR118A[ ] Extreme Condition Mounting Kit - All BAYCURB & BAYADAP ...............................................BAYEXMK001A[ ]Extreme Condition Mounting Kit - All BAYUTIL ......................................................................BAYEXMK002A[ ] Extreme Condition Mounting Kit - All Slab Mounts .................................................................BAYEXMK003A[ ]Lifting Lug Kit BAYLlFT002B[ ]SUPPLEMENTARY HEATERS (1 PHASE)3.76/5.00 KW Heater (208/240V 1PH) (4WCZ6036-060A1) .................................................. BAYHTRV105E[ ]6.00/8.00 KW Heater (208/240V 1PH( (4WCZ6036-060A1) ...................................................BAYHTRV108E[ ] 7.50/10.00 KW Heater (208/240V 1PH) (4WCZ6036-0601) .................................................. BAYHTRV110E[ ]11.27/15.00 KW Heater (208/240V 1PH) (4WCZ6036-060A1) .............................................. BAYHTRV115E[ ]15.00/20.00 KW Heater (208/240V 1PH) (4WCZ6048-060A1) .............................................. BAYHTRV120E[ ]18.78/25.00 KW Heater (208/240V 1PH) (4WCZ6048-060A1) ...............................................BAYHTRV125E[ ]SUPPLEMENTARY HEATERS (3 PHASE)3.76/5.00 KW Heater (208/240V 3PH) (4WCZ6036-060A3) ...................................................BAYHTRV305E[ ]6.00/8.00 KW Heater (208/240V 3PH( (4WCZ6036-060A3) ...................................................BAYHTRV308E[ ] 7.50/10.00 KW Heater (208/240V 3PH) (4WCZ6036-060A3) .................................................BAYHTRV310E[ ]11.27/15.00 KW Heater (208/240V 3PH) (4WCZ6036-060A3) ...............................................BAYHTRV315E[ ]15.00/20.00 KW Heater (208/240V 3PH) (4WCZ6048-060A3) ...............................................BAYHTRV320E[ ]18.78/25.00 KW Heater (208/240V 3PH) (4WCZ6048-060A3) ...............................................BAYHTRV325E[ ]5.00 KW Heater (460V 3PH) (4WCZ6036-060A4) ..................................................................BAYHTRV405E[ ]8.00 KW Heater (460V 3PH( (4WCZ6036-060A4) ..................................................................BAYHTRV408E[ ] 10.00 KW Heater (460V 3PH) (4WCZ6036-060A4) ................................................................BAYHTRV410E[ ]10.00 KW Heater (460V 3PH) (4WCZ6036-060A4) ................................................................BAYHTRV415E[ ]10.00 KW Heater (460V 3PH) (4WCZ6048-060A4) ................................................................BAYHTRV420E[ ]15.00 KW Heater (460V 3PH) (4WCZ6048-060A4) ................................................................BAYHTRV425E[ ]Single Power Entry Kit 8 . ...................................................................................................... BAYSPEK060F[ ]Single Power Entry Kit 8 . ...................................................................................................... BAYSPEK061E[ ]Single Power Entry Kit 8 . ...................................................................................................... BAYSPEK062F[ ]Single Power Entry Kit 8 . ...................................................................................................... BAYSPEK063F[ ]Single Power Entry Kit 8 . ...................................................................................................... BAYSPEK064E[ ]Single Power Entry Kit 8 . ...................................................................................................... BAYSPEK065E[ ]

NOTES: 1 Must use internal filter frame when economizer or fresh air kit is used. 2 Dry bulb control standard with economizer. 3 Ships knocked down. 4 Downflow only. 5 Low Ambient cooling requires crankcase heater (BAYCCHT----A). 6 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 7 BAYCOVR112,118A will not cover BAYSQRD002A applications. 8 See tables on pages 8 - 11 for matching kit with units and heaters. 9 BAYOSAC001B is not compatible with BAYACCDOR1A or BAYACCDOR2A. 0 BAYACCDOR1A requires BAYFLTR101B & BAYACCDOR2A requires BAYFLTR201B. They are not backward compatible to BAYFLTR101/201A.

Page 5: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

5

MODELRATED Volts/PH/HzPerformance CoolingBTUH (High)Indoor Airflow (CFM)Power Input (KW)BTUH (Low)Indoor Airflow (CFM)Power Input (KW)EER - HI / LOW / SEER Sound Power Rating [dB(A)]Performance Heating(High Temp.)BTUH / COP (High)Power Input (KW)(Low Temp.) BTUH / COP (High)Power Input (KW)(High Temp.)BTUH / COP (Low)Power Input (KW)(Low Temp.) BTUH / COP (Low)Power Input (KW)HSPF (BTU / Watt-Hr.)POWER CONN.—V/Ph/HzMin. Brch. Cir. AmpacityFuse Size — Max. / Recmd. (amps) COMPRESSORVolts/Ph/HzR.L. Amps — L.R. AmpsOUTDOOR COIL — TYPERows/F.P.I.Face Area (sq.ft.)Tube Size (in.)Refrigerant ControlINDOOR COIL — TYPERows/F.P.I.Face Area (sq.ft.)Tube Size (in.)Refrigerant ControlDrain Conn. Size (in.)OUTDOOR FAN — TYPEDia. (in.)Drive/No. SpeedsCFM @ 0.0 in. w.g.Motor — HP/R.P.M.Volts/Ph/HzF.L. Amps/L.R. AmpsINDOOR FAN — TYPEDia x Width (in.)Drive/No. SpeedsCFM @ 0.0 in. w.g.Motor — HP/R.P.M.Volts/Ph/HzF.L. Amps/L.R. AmpsFILTER / FURNISHEDType RecommendedRecmd. Face Area (sq. ft.)REFRIGERANT / Charge (lbs.)DIMENSIONSCrated (in.)WEIGHT / Shipping / Net (lbs.)

1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240.

2 Sound Power values are not adjusted for ARI 270-95 tonal corrections.

3 Calculated in accordance with currently prevailing Nat'l Electrical Code.

4 Standard Air — Dry Coil — Outdoor.

5 Standard Air — Wet Coil — Indoor.

6 Rated in accordance with D.O.E. test procedure.

7 Filters must be installed in return air system. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendations with clean resistance of 0.05" W.C.

4WCZ6036A1000A208-230/1/60

3600011252.61

252008251.8

12.2 / 13.3 / 16.470

34000 / 3.92.59

20800 / 2.622.371

23400 / 3.91.8

13300 / 2.21.78

9208-230/1/60

26.240 / 40

2-STAGE SCROLL208-230/1/60

16.7 / 82SPINE-FIN

2 / 2415.493/8

EXPANSION VALVEPLATE FIN

4 / 153.543/8

EXPANSION VALVE3/4 FEMALE NPT

PROPELLER23.4

DIRECT / 13020

1/6 / 830208-230/1/60

0.9 / 1.65CENTRIFUGAL

10 X 10DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE1/2 / VARIABLE208-230/1/60

4.3 / 4.3NO

THROWAWAY4.0

R410A / 7.8H X W X L

47.86 / 44.5 / 52.03468 / 372

4WCZ6036A3000A208-230/3/60

3600011252.61

252008251.8

12.2 / 13.3 / 16.470

34000 / 3.92.59

20800 / 2.622.371

23400 / 3.91.8

13300 / 2.21.78

9208-230/3/60

19.130 / 30

2-STAGE SCROLL208-230/3/60

11.2 / 58SPINE-FIN

2 / 2415.493/8

EXPANSION VALVEPLATE FIN

4 / 153.543/8

EXPANSION VALVE3/4 FEMALE NPT

PROPELLER23.4

DIRECT / 13020

1/6 / 830208-230/1/60

0.9 / 1.65CENTRIFUGAL

10 X 10DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE1/2 / VARIABLE208-230/1/60

4.3 / 4.3NO

THROWAWAY4.0

R410A / 7.8H X W X L

47.86 / 44.5 / 52.03468 / 372

4WCZ6036A4000A460/3/60

3600011252.61

252008251.8

12.2 / 13.3 / 16.470

34000 / 3.92.59

20800 / 2.622.371

23400 / 3.91.8

13300 / 2.21.78

9460/3/60

10.415 / 15

SCROLL460/3/604.5 / 29

Spine-Fin2 / 2415.493/8

EXPANSION VALVEPLATE FIN

4 / 153.543/8

EXPANSION VALVE3/4 FEMALE NPT

PROPELLER23.4

DIRECT / 13020

1/6 / 830460/1/600.5 / 0.84

CENTRIFUGAL10 X 10

DIRECT / VARIABLESEE FAN PERFORMANCE TABLE

1/2 / VARIABLE208-230/1/60

4.3 / 4.3NO

THROWAWAY4.0

R410A / 7.8H X W X L

47.86 / 44.5 / 52.03468 / 372

General Data

Page 6: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

6

MODELRATED Volts/PH/HzPerformance CoolingBTUH (High)Indoor Airflow (CFM)Power Input (KW)BTUH (Low)Indoor Airflow (CFM)Power Input (KW)EER - HI / LOW / SEER Sound Power Rating [dB(A)]Performance Heating(High Temp.)BTUH / COP (High)Power Input (KW)(Low Temp.) BTUH / COP (High)Power Input (KW)(High Temp.)BTUH / COP (Low)Power Input (KW)(Low Temp.) BTUH / COP (Low)Power Input (KW)HSPF (BTU / Watt-Hr.)POWER CONN.—V/Ph/HzMin. Brch. Cir. AmpacityFuse Size — Max. / Recmd. (amps) COMPRESSORVolts/Ph/HzR.L. Amps — L.R. AmpsOUTDOOR COIL — TYPERows/F.P.I.Face Area (sq.ft.)Tube Size (in.)Refrigerant ControlINDOOR COIL — TYPERows/F.P.I.Face Area (sq.ft.)Tube Size (in.)Refrigerant ControlDrain Conn. Size (in.)OUTDOOR FAN — TYPEDia. (in.)Drive/No. SpeedsCFM @ 0.0 in. w.g.Motor — HP/R.P.M.Volts/Ph/HzF.L. Amps/L.R. AmpsINDOOR FAN — TYPEDia x Width (in.)Drive/No. SpeedsCFM @ 0.0 in. w.g.Motor — HP/R.P.M.Volts/Ph/HzF.L. Amps/L.R. AmpsFILTER / FURNISHEDType RecommendedRecmd. Face Area (sq. ft.)REFRIGERANT / Charge (lbs.)DIMENSIONSCrated (in.)WEIGHT / Shipping / Net (lbs.)

1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240.

2 Sound Power values are not adjusted for ARI 270-95 tonal corrections.

3 Calculated in accordance with currently prevailing Nat'l Electrical Code.

4 Standard Air — Dry Coil — Outdoor.

5 Standard Air — Wet Coil — Indoor.

6 Rated in accordance with D.O.E. test procedure.

7 Filters must be installed in return air system. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendations with clean resistance of 0.05" W.C.

General Data4WCZ6048A1000A

208-230/1/60

4750015753.26

3450011502.58

12.0 / 13.6 / 16.071

44500 / 4.03.26

27000 / 2.672.96

32400 / 4.02.37

18500 / 2.422.249.0

208-230/1/6034.1

50 / 502-STAGE SCROLL

208-230/1/6021.2 / 96.0SPINE-FIN

2 / 2423.573/8

EXPANSION VALVEPLATE FIN

4 / 155.03/8

EXPANSION VALVE3/4 FEMALE NPT

PROPELLER28.2

DIRECT / 14220

1/6 / 830208-230/1/60

0.9 / 1.65CENTRIFUGAL

10 X 10DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE3/4 / VARIABLE208-230/1/60

6.8 / 6.8NO

THROWAWAY5.3

R410A / 8.8H X W X L

52.0 / 47.0 / 62.0607 / 479

4WCZ6048A3000A208-230/3/60

4750015753.26

3450011502.58

12.0 / 13.6 / 16.071

44500 / 4.03.26

27000 / 2.672.96

32400 / 4.02.37

18500 / 2.422.249.0

208-230/3/6024.5

35 / 352-STAGE SCROLL

208-230/3/6013.5 / 88.0SPINE-FIN

2 / 2423.573/8

EXPANSION VALVEPLATE FIN

4 / 155.03/8

EXPANSION VALVE3/4 FEMALE NPT

PROPELLER28.2

DIRECT / 14220

1/6 / 830208-230/1/60

0.9 / 1.65CENTRIFUGAL

10 X 10DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE3/4 / VARIABLE208-230/1/60

6.8 / 6.8NO

THROWAWAY5.3

R410A / 8.8H X W X L

52.0 / 47.0 / 62.0607 / 479

4WCZ6048A4000A460/3/60

4750015753.26

3450011502.58

12.0 / 13.6 / 16.071

44500 / 4.03.26

27000 / 2.672.96

32400 / 4.02.37

18500 / 2.422.249.0

460/3/6015.3

20 / 202-STAGE SCROLL

460/3/606.4 / 41.0SPINE-FIN

2 / 2423.573/8

EXPANSION VALVEPLATE FIN

4 / 155.03/8

EXPANSION VALVE3/4 FEMALE NPT

PROPELLER28.2

DIRECT / 14220

1/6 / 830460/1/600.5 / 0.84

CENTRIFUGAL10 X 10

DIRECT / VARIABLESEE FAN PERFORMANCE TABLE

3/4 / VARIABLE208-230/1/60

6.8 / 6.8NO

THROWAWAY5.3

R410A / 8.8H X W X L

52.0 / 47.0 / 62.0607 / 479

Page 7: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

7

MODELRATED Volts/PH/HzPerformance CoolingBTUH (High)Indoor Airflow (CFM)Power Input (KW)BTUH (Low)Indoor Airflow (CFM)Power Input (KW)EER - HI / LOW / SEER Sound Power Rating [dB(A)]Performance Heating(High Temp.)BTUH / COP (High)Power Input (KW)(Low Temp.) BTUH / COP (High)Power Input (KW)(High Temp.)BTUH / COP (Low)Power Input (KW)(Low Temp.) BTUH / COP (Low)Power Input (KW)HSPF (BTU / Watt-Hr.)POWER CONN.—V/Ph/HzMin. Brch. Cir. AmpacityFuse Size — Max. / Recmd. (amps) COMPRESSORVolts/Ph/HzR.L. Amps — L.R. AmpsOUTDOOR COIL — TYPERows/F.P.I.Face Area (sq.ft.)Tube Size (in.)Refrigerant ControlINDOOR COIL — TYPERows/F.P.I.Face Area (sq.ft.)Tube Size (in.)Refrigerant ControlDrain Conn. Size (in.)OUTDOOR FAN — TYPEDia. (in.)Drive/No. SpeedsCFM @ 0.0 in. w.g.Motor — HP/R.P.M.Volts/Ph/HzF.L. Amps/L.R. AmpsINDOOR FAN — TYPEDia x Width (in.)Drive/No. SpeedsCFM @ 0.0 in. w.g.Motor — HP/R.P.M.Volts/Ph/HzF.L. Amps/L.R. AmpsFILTER / FURNISHEDType RecommendedRecmd. Face Area (sq. ft.)REFRIGERANT / Charge (lbs.)DIMENSIONSCrated (in.)WEIGHT / Shipping / Net (lbs.)

1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240.

2 Sound Power values are not adjusted for ARI 270-95 tonal corrections.

3 Calculated in accordance with currently prevailing Nat'l Electrical Code.

4 Standard Air — Dry Coil — Outdoor.

5 Standard Air — Wet Coil — Indoor.

6 Rated in accordance with D.O.E. test procedure.

7 Filters must be installed in return air system. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendations with clean resistance of 0.05" W.C.

General Data4WCZ6060A1000A

208-230/1/60

5650019004.18

4080013503.23

11.5 / 12.5 / 15.273

55000 / 3.854.18

35000 / 2.583.97

38900 / 3.83.14

22800 / 2.23.048.6

208-230/1/6037.1

60 / 602-STAGE SCROLL

208-230/1/6023.0 / 118.0SPINE-FIN

2 / 2423.573/8

EXPANSION VALVEPLATE FIN

4 / 155.03/8

EXPANSION VALVE3/4 FEMALE NPT

PROPELLER28.2

DIRECT / 14720

1/4 / 830208-230/1/60

1.4 / 3.37CENTRIFUGAL

11 X 10DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE1 / VARIABLE208-230/1/60

6.9 / 6.9NO

THROWAWAY5.3

R410A / 9.7H X W X L

52.0 / 47.0 / 62.0623 / 495

4WCZ6060A3000A208-230/3/60

5650019004.18

4080013503.23

11.5 / 12.5 / 15.273

55000 / 3.854.18

35000 / 2.583.97

38900 / 3.83.14

22800 / 2.23.048.6

208-230/3/6030.3

45 / 452-STAGE SCROLL

208-230/3/6017.6 / 123.0SPINE-FIN

2 / 2423.573/8

EXPANSION VALVEPLATE FIN

4 / 155.03/8

EXPANSION VALVE3/4 FEMALE NPT

PROPELLER28.2

DIRECT / 14720

1/4 / 830208-230/1/60

1.4 / 3.37CENTRIFUGAL

11 X 10DIRECT / VARIABLE

SEE FAN PERFORMANCE TABLE1 / VARIABLE208-230/1/60

6.9 / 6.9NO

THROWAWAY5.3

R410A / 9.7H X W X L

52.0 / 47.0 / 62.0623 / 495

4WCZ6060A4000A460/3/60

5650019004.18

4080013503.23

11.5 / 12.5 / 15.273

55000 / 3.854.18

35000 / 2.583.97

38900 / 3.83.14

22800 / 2.23.048.6

460/3/6019.2

25 / 252-STAGE SCROLL

460/3/609.2 / 62.0SPINE-FIN

2 / 2423.573/8

EXPANSION VALVEPLATE FIN

4 / 155.03/8

EXPANSION VALVE3/4 FEMALE NPT

PROPELLER28.2

DIRECT / 14720

1/4 / 830460/1/600.7 / 1.68

CENTRIFUGAL11 X 10

DIRECT / VARIABLESEE FAN PERFORMANCE TABLE

1 / VARIABLE208-230/1/60

6.9 / 6.9NO

THROWAWAY5.3

R410A / 9.7H X W X L

52.0 / 47.0 / 62.0623 / 495

Page 8: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

8

Heater DataTable 1. 4WCZ6036A to 4WCZ6060A Heater Data

NOTES:

1. Any power supply and circuits must be wired and protected in accordance with local electrical codes. 2. The MCA values listed are for electric heater only. 3. Field wire must be rated at least 75°C 4. The HACR circuit breaker is for U.S.A. installations only. 5. For Canada installation reference only. # Heater uses fuses.

KW BTUH 1 2

^W/TC*3018-060‡1^W/TCY4024-060‡1^WCZ6036-060‡1

^W/TC*3018-060‡1^W/TCY4024-060‡1^WCZ6036-060‡1

BAYHTRV108E 208/240 1 29/33 6.0/8.0 20500/27300 1 6.0/8.0 36/41 40/45 40/45

^W/TC*3024-060‡1^W/TCY4024-060‡1^WCZ6036-060‡1

^W/TC*3030-060‡1^W/TCY4030-060‡1^WCZ6036-060‡1

^W/TC*3042-060‡1^W/TCY4042-060‡1^WCZ6048-060‡1

4WC*3042‡1^W/TC*3060‡1

^W/TCY4042-060‡1^WCZ6048-060‡1

^W/TC*3036-060‡3^W/TCY4036-060‡3^WCZ6036-060‡3

^W/TC*3036-060‡3^W/TCY4036-060‡3^WCZ6036-060‡3

BAYHTRV308E 208/240 3 17/19 6.0/8.0 20500/27300 1 6.0/8.0 21/24 25/25 25/25

^W/TC*3036-060‡3^W/TCY4036-060‡3^WCZ6036-060‡3

^W/TC*3036-060‡3^W/TCY4036-060‡3^WCZ6036-060‡3

^W/TC*3048-060‡3^W/TCY4048-060‡3^WCZ6048-060‡3

^W/TC*3036-060‡4^WCZ6036-060‡4

BAYHTRV408E 480 3 10 8.0 27300 1 8.0 13 15 15

^WCZ6036-060‡4

^W/TC*3036-060‡4^WCZ6036-060‡4

^W/TC*3048-060‡4^WCZ6048-060‡4

^W/TC*3060‡4^WCZ6048-060‡4

7.5/10.0

40/45 40/45

208/240 3 42/48 15.0/20.0 51200/68300 2 7.5/10.0

45/60

208/240 1 54/63 11.27/15.0 38500/51200 2 7.5/10.0

1 36/42 7.5/10.0 25600/34100

^W/TC*3036-060‡4

BAYHTRV115E#

BAYHTRV110E

BAYHTRV120E#

BAYHTRV305E

BAYHTRV310E

BAYHTRV315E

BAYHTRV320E

BAYHTRV325E#

MAX FUSE OR HACR CKT

BKR SIZE (4)

CANADA ONLY MAX. CKT BKR

SIZE (5)MCA AMPS

NO. OF STAGES

KW/STAGEHEATER CAPACITY

PHASEELECTRIC

HEATER MODELRATED

VOLTAGEUNIT MODEL

3

3

3

BAYHTRV105E

480

208/240 3

208/240

480 24 20.0

90/104 18.78/25.0

3

480

31/36 11.27/15.0

68300

8530025.030

5120015.018

12 10.0 34100

2

2

2

1

10.0

38

30

235.010.0

10.0

10.0 040.51

25

30

40

25

30

15

52/60 60/60

65/75

8

15

08/072

15

5.0

1 10.0

11.26/15.0 7.5/10.0

2 7.5/10.0 3.76/5.0

7.5/10.0

39/45

26/30 30/30 30/30

10/12 3.76/5.0 12800/17100 1 3.76/5.0

21/24 7.5/10.0 25600/34100 1

90/110

3.76/5.0 68/78

64100/85300 2 11.26/15.0 7.5/10.0

70/80

113/130 125/150

7.5/10.0 90/104 90/110

3.76/5.0 12800/17100 1 3.76/5.0

1 7.5/10.0

25/3023/26

45/52 45/60

25/30

70/80

208/240 1 72/83 15.0/20.0 51200/68300 2 7.5/10.0

BAYHTRV420E

BAYHTRV425E

60/60

70/80

15 15BAYHTRV405E

BAYHTRV410E

480

480

208/240 1 18/21

BAYHTRV415E

208/240

208/240 3

208/240 3

3

^W/TC*3060‡3^W/TCY4048-060‡3^WCZ6048-060‡3

^W/TC*3036-060‡4^WCZ6036-060‡4

BAYHTRV125E#

38500/51200

171006 5.0

52/60 18.78/25.0 64100/85300

125/150

208/240 3 13/15 15/15 15/15

1

Page 9: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

9

Single Power Entry Kit DataTable 2. BAYSPEK060F Ampacity and Max Fusing/Circuit Breakers

Page 10: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

10

Single Power Entry Kit DataTable 3. BAYSPEK061E Ampacity and Max Fusing/Circuit Breakers

Page 11: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

11

Single Power Entry Kit DataTable 4. BAYSPEK062F,63F,64E & 65E Ampacity and Max Fusing/Circuit Breakers

Page 12: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

12

Indoor Fan Performance 4WCZ6048A

Indoor Fan Performance 4WCZ6060A

Indoor Blower PerformanceIndoor Fan Performance 4WCZ6036A

Page 13: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

13

SWITCH SETTINGS SELECTION NOMINAL AIRFLOW

7-OFF 8-OFF LOW 1400 CFM

7-ON 8-OFF HIGH 1600 CFM

7-OFF 8-ON HIGH 1600 CFM

7-ON 8-ON HIGH 1600 CFM

SWITCH SETTINGS SELECTION NOMINAL AIRFLOW

7-OFF 8-OFF LOW 1050 CFM

7-ON 8-OFF HIGH 1200 CFM

7-OFF 8-ON HIGH 1200 CFM

7-ON 8-ON HIGH 1200 CFM

4WCZ6048 AIRFLOW WITH AUXILIARY HEAT (CFM)

4WCZ6036 AIRFLOW WITH AUXILIARY HEAT (CFM)

5-OFF 6-OFF NONE 100%5-ON 6-OFF 45 SEC 100%5-OFF 6-ON 90 SEC 50%5-ON 6-ON ** 50-100%

** This ENHANCED MODE selection provides a ramping up and ramping down of the indoor blower speed to provide improved comfort, quietness, and potential energy savings. The Graph below shows the ramping process

COOLING FAN DELAY OPTIONS

SWITCH SETTINGS DELAYNOMINAL AIRFLOW

4WCZ6060 AIRFLOW WITH AUXILIARY HEAT (CFM)

SWITCH SETTINGS SELECTION NOMINAL AIRFLOW

7-OFF 8-OFF LOW 1400 CFM

7-ON 8-OFF HIGH 1600 CFM

7-OFF 8-ON HIGH 1600 CFM

7-ON 8-ON HIGH 1600 CFM

Indoor Blower Performance

OFF OFF

35%

56%

35% Dehumidify

Fast Coil Cooling

EnhancedEfficiency

7.5minutes

3minutes

(Fan Only)

1minute

SY

ST

EM

AIR

FL

OW

(C

FM

) 50%

80%

50%

100%

Only if required

SECOND STAGE

FIRST STAGE

70% Only if required

EnhancedComfort

COMPRESSOR OPERATION ON OFF

Page 14: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

14

Typical Wiring

Page 15: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

15

Typical Wiring

Page 16: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

16

Optional Equipment

BAYCURB050A FULL PERIMETER ROOF MOUNTING CURB FOR 4WCZ6036A

46 3/8

17 7/8

3

3 5/8

19 1/2

2 3/16

19 1/2

14

1 1/2

38 7/8

15

35 7/843 3/8

The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use.

Page 17: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

17

Optional Equipment

BAYCURB051A Full Perimeter Roof Mounting Curb for 4WCZ6048-060A

56 1/8

15 7/8

3

10 7/819 1/2

4 3/4

19 1/2

14

41 7/8

20

1 1/2

38 7/8 53 1/8

The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use.

Page 18: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

18

Optional Equipment

The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not respon-sible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use.

BAYFLTR101, 201B, 1" - 2" Filter Rack(Mounts in Filter/Coil Section)

BAYACCDOR1A & BAYACCDOR2A Hinged Filter Access DoorReplaces Filter/Coil Access Panel

Filter

Page 19: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

19

BAYECON103,104A Down Discharge Economizer and Rain Hood(Mounts Over Horizontal Return Air Opening)

A

B

C D

E

BAYCON203,204A Horizontal Economizer and Rain Hood

Optional Equipment

Return DuctRoofcurb

Relief damper

Mist elimi-nator

Economizer rain hood

HVAC Unit

Outside air dampers

Return air dampers

Required filter kit, order separately

A

The drawings on this page are prepared by the manu-facturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items de-picted in the drawings. The manufacturer is not respon-sible for the unauthorized use of these drawings and expressly disclaims any liability for damages result-ing from such unauthorized use.

Economizer

Gaskets (2)

Rain HoodDuct

Mixed Air Sensor

Economizer Models A

BAYECON103A4WCZ6036A4DCZ6036A4YCZ6036A

20 1/8"

BAYECON104A4WCZ6048-060A4DCZ6048-060A4YCZ6048-060A

24 3/8"

Economizer A B C D E F

BAYECON203AA 22" 20"16

7/8"15

11/16"11

11/16"15"

BAYECON204AA 26"22

21/32"19"

17 11/16"

14 11/16"

21-3/8"

Page 20: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

20

Optional Equipment

A

B

CD

FULLYOPEN

2/31/3

FULLYCLOSED

BAYOSAH001,002A, 25% Outside Air Damper(Replaces Filter/Coil Access Panel)

The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for dam-ages resulting from such unauthorized use.

BAYDMPR101,102A, 25% Motorized Outside Air Damper(Mounts Over Horizontal Return AIr Opening)

D

C B

A

E

Manual Fresh

Air ModelUnit Application Models A B C D

BAYOSAH001

4YC,WC3018-036

4TC*3018-036

4W/T/Y/DCY4024-036

4W/Y/DCZ6036

22 7/16" 20 11/16" 12 3/8" 9 3/16"

BAYOSAH002

4YC,WC3042-060

4TC*3042-060

4W/T/Y/DCY4042-060

4W/Y/DCZ6048-060

25 3/16" 20 11/16" 12 3/8" 9 3/16"

Unit Application Models A B C D E

BAYDMPR101A

4YC,WC3018-036

4TC3018-036

4W/T/Y/DCY4024-036

4W/Y/DCZ6036

15 13/16" 11 13/16" 10 1/4" 11 1/2" 12 1/4"

BAYDMPR102A

4YC,WC3042-060

4TC3042-060

4W/T/Y/DCY4042-060

4W/Y/DCZ6048-060

18 3/16" 15 1/8" 10 1/4" 11 1/2" 12 1/4"

Page 21: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

21

Dimensional Data and Weights

Figure 1. WCZ6036A (1 of 3)

NOTE: The view labeled “Bottom Side” represents the Base as viewed looking up from

underneath the unit.

Page 22: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

22

Dimensional Data and Weights

Figure 2. WCZ6036A (2 of 3)

Page 23: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

23

Dimensional Data and Weights

Figure 3. WCZ6036A (3 of 3)

Page 24: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

24

Dimensional Data and Weights

Figure 4. WCZ6048A through WCZ6060A (1 of 3)

NOTE: The view labeled “Bottom Side” represents the Base as viewed looking up from

underneath the unit.

Page 25: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

25

Dimensional Data and Weights

Figure 5. WCZ6048A through WCZ6060A (2 of 3)

Page 26: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

26

Dimensional Data and Weights

Figure 6. WCZ6048A through WCZ6060A (3 of 3)

Page 27: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

27

Mechanical SpecificationsGeneral

The units shall be horizontal airflow as shipped and convertible to downflow. All units shall be factory assembled, piped, internally wired and fully charged with refrigerant. Units shall be certified to UL Standard 1995. All units shall be factory run tested to check cooling operation, fan and blower rotation and control or TXV se-quence. Units shall be designed to operate at ambient temperatures between 115°F and 55°F in cooling as manufactured. Cooling performance shall be rated in ac-cordance with A.H.R.I. standards.

Unit Casing

All components shall be mounted in a weather-resistant steel cabinet with an enamel finish. Access panels shall be pro-vided for unit controls and indoor coil and fans. Indoor air section compartment shall be completely insulated with fireproof, permanent, odorless glass fiber material. Knockouts shall be provided for utility and control connections. Drain connections shall be provided to accommodate indoor water runoff.

Compressor

The compressor shall be hermetically sealed, high efficiency Climatuff® two-stage compressors. Internal overcurrent and over temperature protection, internal pressure relief shall be standard.

Refrigeration System

All units shall have TXV in cooling and TXV in heating. Service pressure tap ports, and a refrigerant line filter dryer shall be stan-dard.

Indoor Coil

Coils shall be internally finned or smooth bore 3/8" copper tubes mechanically bonded to configured aluminum plate fin as standard. Evaporator coil leak and pressure tested to 200 psig; condenser coil tested to 450 psig.

Condenser Coil —

The Spine Fin™ condenser coil shall be continuously wrapped, corrosion resis-tant all aluminum with minimum brazed joints. This coil is 3/8 inch O.D. seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels.

Indoor Air Fan — Direct-drive, forward-curved, centrifugal wheel in a Composite Vortica® Blower housing. Motor shall have thermal overload protection. Permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber mounts.

Condenser Fan — Direct-drive, draw thru propeller type. Weather-proofed permanent split capacitor fan motor shall have built-in thermal overload and per-manently lubricated motor bearings.

System Controls

System controls include condenser fan, evaporator fan and compressor contac-tors.

Accessories

Roof Curb — The roof curb shall be de-signed to mate with the unit and provide support and complete weathertight instal-lation when properly installed. Adhesive back polyurethane sealing strips shall be provided to ensure an airtight seal be-tween supply and return openings of the curb and unit. The roof curb design allows field fabricated ductwork to be connected directly to the curb. Curb ships knocked down for field assembly, and includes factory-installed wood nailer strips.

Electric Heaters — Each heater assem-bly shall include power supply fusing if over 48 amps, automatic resetting limit switches and heat limiters for thermal protection. Heaters shall be provided with polarized plugs for quick connection to unit low voltage wiring. Electric heat mod-ules shall be UL listed.

Single Source Power Entry — This ac-cessory when used with electric heat accessory shall allow single source power connection to unit and heater combina-tion. Single source power entry kits shall have specific matching heater(s). Kit shall include high voltage terminal blocks, fuse blocks and fuses, cut-to-length in-terconnecting wiring, and junction box (if required) to provide power sources with fuse protection as required for both the unit and accessory heater. Kit compo-nents shall install within the unit cabinet in the heater access section. Single source branch power circuit shall be protected and wired in accordance with local codes.

Fully Modulating Economizer — This accessory shall be field installed and be composed of the following items: 0-100% fresh air damper, damper drive motor, fixed dry bulb enthalpy control, and low voltage wiring plug for electrical connections. Solid state enthalpy or differential enthalpy con-trol is optional. Economizer operations shall be controlled by the preset position of the enthalpy control. A barometic relief damper shall be standard with the econo-mizer and provide a pressure operated damper that shall be gravity closing and prohibit entrance of outside air on equip-ment “off” cycle. Economizer requires BAYRLAY004A relay kit to interface the economizer to the heat pump.

Manual Outside Air Dampers — Rain hood and screen shall be field installed. Suitable for up to 25% outside air.

Start Kit — Extra compressor starting ca-pacity for single phase equipment.

Control Options

Standard Indoor Thermostats — Two stage heating/cooling or one stage heat-ing/cooling thermostats shall be available in either manual or automatic changeover.

Programmable Electronic Night Set-back Thermostat — Programmable electronic thermostat shall provide heat-ing setback and cooling setup with 7-day, programming capability. 1H/1C or 2H/2C models available.

Page 28: 22-1807-07 Product Data - · PDF file©2012 Trane Pub. No. 22-1807-07 Product Data 4WCZ6036A through 4WCZ6060A Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A 22-1807-07

28

The manufacturer has a policy of continuous product and product data improvement and it reserves the right

to change design and specifications without notice.

Trane6200 Troup HighwayTyler, TX 75707-9010