power relays, a compact and small in size with high dielectric strength of 2000V. Designed applying Maximum function minimum space principles. 22 series are suitable for both 50Hz & 60Hz. Available with a contact capacity of 10 Amps. All fixed contacts powered by WERNER AFT (Anti-Fuse-Technology)TRANSCRIPT
Relays
PRODUCT SPECIFICATIONS
Living Industrial Partnerships
22Series
22 Series Relays
Specifications ................................................................................................................ 222/
Model Number Structure ..................................................................................................22/3
Technical Data .................................................................................................................22/1
Protection & Safety Precautions . 22/........................................................................ 10 - 22/11
Model Number Selection - Blade Type ............................................................... 22/4 - 22/5
Accessories & Dimensional Details .......................................................................22/7 - 22/8
Electrical Characteristics ..................................................................................................22/6
Internal Connections (Bottom View) ................................................................................22/9
22 Series Relays
22 Series Relays
22 Series Relays
WERNER`s 22 Series General Purpose & Power Relays represent the most complete line of state-of-the-art high
performance electrical relays, designed and manufactured to highest international industry standards. Mechanical
lifetimes of up to 10 Million operations and electrical durability of up to 250,000 switching cycles under full load
make WERNER Relays your best choice of all.
22 Series General Purpose & Power Relays by WERNER provide our highly demanding industrial customers out of
all industry verticals worldwide with the most reliable devices in the industry. Combined with the vast selection of
sockets in our 70 – 75 Product Series you will find an industrial solution exceeding your expectations whilst
satisfying you're every need and design requirement.
Features Overview
Highlights
? All models designed applying MFMS design principles (Max Function Min Space)
? All models designed applying solid modeling and finite elements design methods
? All Power Relay Series are equipped with mechanical operation status indicator
? All models design for heavy duty or even vibrating environments
? All models available for use with 50 Hz and 60 Hz cycles
? All fixed contacts powered by WERNER AFT (Anti-Fuse-Technology)
? All Power Relays Series provide massive silver blade or pin contacts
? Power Relay Series with up to 10 Ampere Continuous Load Current
? Most models available in 6V, 12V, 24V, 110V & 220V AC or DC
? Most models available in SPDT, DPDT, 3PDT as well as 4DPT
? Up to 7 types of operation status indication available
Relays
Features:
Relays
Dielectric strength 2,000V
Compact and small
10A Contact Capacity.
Built-in Diode modelsLarge Capacity
SPDT & DPDT
6V
12V
24V
110V
120V
220V
240V
48V
±15% at 20°C
AC Coil Ratings
Voltage
ContinuousVoltage
PickupVoltage
DropoutVoltage
Operation PropertiesCoil Resistance (Ù)Rated Current (mA)
110% max.
80%max.
30%min.
AC 50HzAC 60Hz
18.8
78.8
300
–
8,100
25,892
26,710
1,280
150
75
37
18
ApprovalsApprobations and Declaration of conformity
Overvoltage category
III, as per EN IEC 60947-5-1
Weight
Weight (approx.)
Model No. 22.12 & 22.22 (DPDT)
37g
22.12 & 22.22 (DPDT)
37g
6V
12V
24V
110V
48V
110% max. 80% max. 10% min.
DC Coil Ratings
Voltage
Continuous Voltage Pickup Voltage Dropout Voltage
Rated Current (mA) Coil Resistance (Ù) Operation Properties
±15% at 20°C
R
UL
CE
RoHS
CCC
Demko
S
DPDTSPDT DPDTSPDT DPDTSPDT
8.4
7.5
4.1
4.3
170
86
42
20.5
9.6
8.6
4.7
4.9
128
64
32
18
DPDTSPDT DPDTSPDT
8
47
188
750
2,660
10,000
150
75
37
18
8.4
7.5
4.1
4.3
170
86
42
20.5
9.6
8.6
4.7
4.9
18.8
78.8
300
6,950
8,100
25,892
26,710
1,280
128
64
32
18
8
47
188
750
2,660
10,000
22 Series Relays
22 Series Relays
Relays
22/1
Mechanical Durability
Shock Resistance
Vibration Resistance
Dielectric Strength
Contact Resistance
Operating Humidity
Insulation Resistance
Operating Temperature
Electrical Durability
Operate Time
Power Consumption(approx.)
50,000,000 operations minimum
Damage limits:
Operating extremes:
1,000m/s² (100G)
200m/s² (20G) - SPDT & DPDT
100m/s² (10G) - 3PDT & 4PDT
Damage limits:
Operating extremes:
10 to 55Hz, amplitude 0.5 mm
10 to 55Hz, amplitude 0.5 mm
Between live and dead parts: 2,000V AC, 1 minute
Between contact and coil: 2,000V AC, 1 minute
Between contacts of different poles: 2,000V AC, 1 minute
Between contacts of the same pole: 1,200V AC, 1 minute
Specifications
50mÙ maximum at 5V DC, 1A
45% to 85% RH (No condensation)
100MÙ minimum
–25 to +40°C (No freezing)
–25 to +40°C ( o freezing)N
20ms maximum at 20°C
20ms maximum at 20°C
AC: 1.1VA (50Hz), 1.2VA (60Hz) DC: 0.9W
AC: 1.4 VA (50 Hz), 1.2 VA (60 Hz) DC: 0.9W
25ms maximum at 20°C
25ms maximum at 20°C
SPDT
DPDT
DPDT
SPDT
200,000 operations minimum (120V AC, 10A)SPDT
200,000 operations minimum (120V AC, 10A)DPDT
SPDT
DPDT
DPDT
DPDT
SPDT
SPDT
Operating Frequency
Contact Material
Minimum Applicable Load
Release Time
Electrical: 1,800 operations/hour maximum
Mechanical: 18,000 operations/hour maximum
Silver cadmium oxide
24V DC, 30 mA5V DC, 100 mA (reference value)
Contact Ratings
Allowable Contact Power Rated Load
Model
DPDT
SPDT
Continuous Current
10A
5A
Resistive Load
1540VA300W
600VA90W
Inductive Load
990VA 210W
176VA 45W
Voltage
110V AC
110V AC
220V AC
220V AC
30V DC
30V DC
Res. Load
10 A
7 A
10 A
Ind. Load
7A
7A
4.5A
4.5A
7A
7A
–
–
–
–
–
–
–
–
–
10 A
7 A
10 A
22 Series Relays
22 Series Relays
Maximum Contact Capacity
22/2
Model Number Structure - Relays
Terminal Type
1 Blade
Series
22 Series Relays
Number of Poles
SPDT
DPDT
1
2
22. 12. 11. 120
Types
Basic0
LED
LED & Check button & Diode
LED & Diode
LED & RC
1
4
2
5
3
6 LED & Check button & RC
LED & Check button
22 Series Relays
22 Series Relays 22/3
Voltage
012
048
120
024
110
220
240
12V
48V
120V
24V
110V
220V
240V
006 6V
AC
DC
Coil
1
2
Appearance
Basic
TerminalType
VoltageTypes
LED
LED & Diode
LED &
Check button Diode &
LED & Check button
LED &
Check buttonRC &
LED & RC
Model Number Selection
Blade
Model No.
SPDT
AC
6V
12V
24V
48V
110V
120V
220V
240V
6V
6V
6V
6V
6V
6V
12V
12V
12V
12V
12V
12V
24V
24V
24V
24V
24V
24V
48V
48V
48V
48V
48V
48V
110V
110V
110V
110V
110V
110V
120V
120V
120V
120V
120V
120V
220V
220V
220V
220V
220V
220V
240V
240V
240V
240V
240V
240V
22.11.51.012
22.11.51.024
22.11.51.048
22.11.51.110
22.11.51.120
22.11.51.220
22.11.51.240
22.11.51.006
22.11.01.006
22.11.01.012
22.11.01.024
22.11.01.048
22.11.01.110
22.11.01.120
22.11.01.220
22.11.01.240
22.11.11.006
22.11.11.012
22.11.11.024
22.11.11.048
22.11.11.110
22.11.11.120
22.11.11.220
22.11.11.240
22.11.31.012
22.11.31.024
22.11.31.048
22.11.31.110
22.11.31.120
22.11.31.220
22.11.31.240
–
–
–
–
–
–
–
–
22.11.31.006
–
–
–
–
–
–
–
–
22.11.61.012
22.11.61.024
22.11.61.048
22.11.61.110
22.11.61.120
22.11.61.220
22.11.61.006
22.11.61.240
SPDT
DPDT
22 Series Relays
22 Series Relays22/4
Model Number Selection
Model No.
DPDT
AC DC
Model No.
SPDT
DC
22.12.02.006
22.12.02.012
22.12.02.024
22.12.02.048
22.12.02.110
22.12.02.120
22.12.02.220
22.12.02.240
22.12.12.006
22.12.12.012
22.12.12.024
22.12.12.048
22.12.12.110
22.12.12.120
22.12.12.220
22.12.12.240
22.12.22.006
22.12.22.012
22.12.22.024
22.12.22.048
22.12.22.110
22.12.22.120
22.12.22.220
22.12.22.240
22.12.32.006
22.12.32.012
22.12.32.024
22.12.32.048
22.12.32.110
22.12.32.120
22.12.32.220
22.12.32.240
22.12.42.006
22.12.42.012
22.12.42.024
22.12.42.048
22.12.42.110
22.12.42.120
22.12.42.220
22.12.42.240
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
22.12.51.012
22.12.51.024
22.12.51.048
22.12.51.110
22.12.51.120
22.12.51.220
22.12.51.240
22.12.51.006
22.12.01.006
22.12.01.012
22.12.01.024
22.12.01.048
22.12.01.110
22.12.01.120
22.12.01.220
22.12.01.240
22.12.11.006
22.12.11.012
22.12.11.024
22.12.11.048
22.12.11.110
22.12.11.120
22.12.11.220
22.12.11.240
22.12.31.012
22.12.31.024
22.12.31.048
22.12.31.110
22.12.31.120
22.12.31.220
22.12.31.240
–
–
–
–
–
–
–
–
22.12.31.006
–
–
–
–
–
–
–
–
22.12.61.012
22.12.61.024
22.12.61.048
22.12.61.110
22.12.61.120
22.12.61.220
22.12.61.006
22.12.61.240
22.11.52.012
22.11.52.024
22.11.52.048
22.11.52.110
22.11.52.120
22.11.52.220
22.11.52.240
22.11.52.006
22.11.02.006
22.11.02.012
22.11.02.024
22.11.02.048
22.11.02.110
22.11.02.120
22.11.02.220
22.11.02.240
22.11.12.006
22.11.12.012
22.11.12.024
22.11.12.048
22.11.12.110
22.11.12.120
22.11.12.220
22.11.12.240
22.11.32.012
22.11.32.024
22.11.32.048
22.11.32.110
22.11.32.120
22.11.32.220
22.11.32.240
–
–
–
–
–
–
–
–
22.11.32.006
–
–
–
–
–
–
–
–
22.11.62.012
22.11.62.024
22.11.62.048
22.11.62.110
22.11.62.120
22.11.62.220
22.11.62.006
22.11.62.240
22 Series Relays
22 Series Relays 22/5
UL - Voltage Ratings
Model
240V AC
120V AC
30V DC
28V DC
Resistive
SPDT SPDTDPDT DPDT
General
–
–
10A
10A 10A
10A
7.5A
– –
–
7.5A
6.5A7A
7A
–
–
AC DC
20.12 & 20.22 (DPDT)
1 3 5 7 92 4 6 8 1 0
50
20
10
100
500
1000
Load Current (A)
110V AC resistive
220V AC inductive
110V AC inductive
220V AC resistive
Life
(×
X 1
0,0
00 o
pera
tions)
Switching Capacity
22.11 & 22.21 SPDT
22.12 & 22.22 DPDT
1 5
0.5
1.0
5.0
10.0
10 100500.1
DC inductiveDC resistive
AC inductive
AC resistive
200 300
22 Series Relays
22 Series Relays22/6
Electrical Characteristics
45
977.03.10
Mounting Clips
Mounting Clips No. Rails WeightWidth
77.03.10 77.02.10 15.2 g45 mm
77.02.10 Aluminum 1000 mm 200 g
DIN Rail No. Material Length Weight Width
374” (9mm)
77.02.10 31
1.7
12.5
5.5
35
25
7.5
DIN Rail35-mm-wide
77.02.10 31.00
10.50
25.18
35.00
41.00 51.00
3.8
0
12.501000
Socket Specification
Accessories
DIN Rails
Mounting Type
DIN Rail
M3 screws - coil M3.5 screws - contact
M3 screws - coil M3.5 screws - contact
72.12.01
300V, 10A
1 Poles 2 PolesWire SizeTorque
72.12.00Without
Finger-safe
With Finger-safe
Up to 3.5mm²(12AWG)
Up to 3.5mm²(12AWG)
0.6 to 1.0 N.m
0.6 to 1.0 N.m
Terminal
12.5
72.11.01
72.11.00
22 Series Relays
22 Series Relays 22/7
22.11 (SPDT)
Dimensions
Blade Terminal
Hold Down Springs & Clips
22 Series Relays
Appearance Suitable For PCB Mount Socket
RelayDescription Suitable For DINMount Socket
Leaf Spring(top latch)
70.03.02
22.12 & 22.22 (DPDT)
22.13 & 22.23 (3PDT)
22.14 & 22.24 (4PDT)
70.03.01
Wire Spring70.02.02
70.02.41
70.02.31
70.02.2122.12 & 22.22 (DPDT)
22.13 & 22.23 (3PDT)
22.14 & 22.24 (4PDT)
22.12 (DPDT)
13
1
5
9
14
14
27
.5
4.7 ø2.6 hole
0.5
6.4
5.4
35.6 max.
22 Series Relays22/8
22 Series Relays
22 Series Relays
Basic Type - Internal Connection (Bottom View)
LED Type - Internal Connection (Bottom View)
LED & Diode Type - Internal Connection (Bottom View)
LED & RC Type - Internal Connection (Bottom View)
SPDT
SPDT
SPDT
DPDT
DPDT
DPDT
DPDT
22/9
Prevents
This protection circuit is very effective in arc suppression whenopening the contact however, the capacitor is charged while thecontacts are opened else the capacitor is discharged through thecontacts, increasing the possibility of contact welding.
This protection circuit is very effective in arc suppression whenopening the contact however, a current flows to charge the capacitor,causing contact welding when the contacts are closed.
Protection
When an inrush current flows through the load, the contact may become welded. The contact ratings show maximum values,Make sure that these values are not exceeded. Contact a contact protection circuit, such as a current limiting resistoras a optional solution.
This protection circuit can be used when the load impedance is smaller than theRC impedance in an AC load power circuit.R: Resistor of approximately the same resistance value as the loadC: 0.1 to 1 µF
This protection circuit can be used for both AC and DC load power circuits.R: Resistor of approximately the same resistance value as the loadC: 0.1 to 1 µF
This protection circuit can be used for DC load power circuits. Use a diode withthe following ratings.Reverse withstand voltage: Power voltage of the load circuit x 10Forward current: More than the load current.
Instructions
+
–R
Incorrect
R
Io
TE
Correct
Back emf suppressing diode
Apply rated voltage to the relay coil to ensure correct relay type.When using a power supply containing a ripple voltage, suppressthe ripple factor within 6% however, a complete DC voltage is best for the coilpower to make sure of stable relay operation.Pickup voltage and dropout voltage depend on the ripple factorwhen power is supplied through a rectificationcircuit. Include a smoothing capacitor for betteroperation.
Special consideration should be taken when driving an element at the same time as the relay operation for the circuit design. Leakage current (Io) flows through the relay coil while the relay is off. Leakage current causes coilrelease failure or adversely affects the vibration resistance and shock resistance. It is advisable to design a circuit as shown.
Connecting a diode to suppress at the back electromotive force prevents a high-voltage pulse which is generated when the relay coil is turned off, causing transistor to deteriorate or break, make sure the coil release time is slightly longer.To shorten the coil release time, connect a Zener diode which is slightly higherthan the power voltage, between the collector and emitter of the transistor.
22 Series Relays
22 Series Relays22/10
Safety Precautions
Do not drop, shock or remove the relay cover to maintain the initial characteristics.The relay cover cannot be removed from the base during normal operation.Use the relay in environments free from dust, condensation, dioxide or hydrogen sulfide.
Make sure that the coil voltage does not exceed applicable coil voltage range.Prevent usage of relays in the vicinity of strong magnetic field, as that my cause in malfunctioning of relays.
Failure to turn off power before wiring, installation, removal andmaintenance may cause electrical shock or fire hazard.
Attention on specifications and rated values to prevent electrical shock or fire hazard.Use wires of the proper size to meet voltage and current requirements.
Tighten the terminal screws on the relay socket to the proper tightening torque.
Prevent using the check button as a switch.The durability of the check button is a minimum of 200 operations.It is advisable to apply a positive voltage to terminals of neighboring poles and a negative voltage to the other terminals of neighboringpoles when using DC loads on 4PDT relays to prevent the possibility of short circuits.
A soldering iron of 30 to 60W would be recommended when soldering the relay terminals and the preferredtime to complete soldering is within 4 seconds approximately.
22 Series Relays
22 Series Relays 22/11
Copyright WERNER Electric. All Right Reserved.
22 Series Relays
WERNER shall not be responsible for conformity with any , codes or standards that apply to use of the products.WERNER shall provide applicable third party certification documents identifying ratings and limitations of use that apply to theproducts in case of the customer's request.
Prevent use of the products for an application involving risk to life or property. Be sure that the WERNER’s products are properly rated and installed for the overall system or equipment. WERNER shall not be responsible for the user's programming of a programmable products.
regulations
Application Considerations
WERNER shall practice to change type/model numbers when published ratings or features are changed, however some specifications and international certifications of the products may be changed without any notice.
When in doubt, please consult with your WERNER representative to confirm actual specifications & approvals on the products.
product specifications and accessories at any time based on improvements and other reasons.WERNER shall change
The information in this catalog has been carefully checked. However, WERNER take no responsibilities for clerical, typographical or proofreading errors.
All marks and symbols use for representation in catalogues belongs to the respective owners.
Please check with WERNER representative for the available marks.
Disclaimers
Warranty
's warranty represents that the products are free from defects in materials and workmanship for a period of one year.
WERNER shall not be responsible for any special loss of profit, commercial loss, indirect consequential damages relevant to products.
WERNER shall not be responsible for repair, warranty or any claims regarding the products unless WERNER’s Analysis conform that the products were properly stored, installed, handled, maintained and not a the results from accident, insufficient,abuse, misuse, natural disaster, improper installation excessive electrical supply, environmental conditions or abnormal mechanical.
WERNER
or
Terms And Conditions
Please read this catalog before purchasing any products. Please consult your WERNER representative for any clarifications or comments.
Product specifications are subject to change without notice.
Thank you for choosing WERNER products.E l e c t r I c Inventing Innovation
Werner Electric India (P) Ltd.No. 38, Hunsur RoadMysore 570012.T : +91 821-425 4500F : +91 821-425 4599E : [email protected]: www.wernerelectric.de