1 25 November 2013 RF Safety Standards Prof Ely Levine AFEKA College of Engineering

Upload: hyun-chong

Post on 02-Jan-2016

15 views

Category:

Documents


1 download

DESCRIPTION

25 November 2013. RF Safety Standards Prof Ely Levine AFEKA College of Engineering. CONTENTS Background Frequencies Standards Guidelines. Non Ionizing Radiation - Any evidence for health risks ?. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: 25 November 2013

1

25 November 2013

RF Safety Standards

Prof Ely LevineAFEKA College of Engineering

Page 2: 25 November 2013

2

CONTENTS

BackgroundFrequenciesStandardsGuidelines

Page 3: 25 November 2013

3

Non Ionizing Radiation -Any evidence for health risks ?

Page 4: 25 November 2013

4

Page 5: 25 November 2013

5

Page 6: 25 November 2013

6

Frequencies

50/60 Hz (power)100-400 kHz (Induction)6.78, 13.56, 27.12 MHz (SRD)VHF/UHF (radio, TV)740-2100 MHz (cellular)S/C (2-8 GHz) (wireless)

Page 7: 25 November 2013

7

ISM - special waivers

6.78, 13.56, 27.12 MHz 433, 868, 915 MHz 2.45, 5.85 GHz24.125 GHz

Page 8: 25 November 2013

8

Standards

Induced Currents [mA] Electric Fields [V/m] Magnetic Fields [A/m]-[mGauss]Radiation [W/m²]-[mW/cm²]

SAR [W/kg]

Page 9: 25 November 2013

9

Standards

ICNIRP (WHO) Worldwide IEEE ANSI C.95 WorldwideFCC CH.15 and CH.18 USAETSI EN300330-1 EuropeCode 6 Canada

Page 10: 25 November 2013

10

Page 11: 25 November 2013

11

Page 12: 25 November 2013

12

Page 13: 25 November 2013

13

Page 14: 25 November 2013

14

Page 15: 25 November 2013

15

Page 16: 25 November 2013

16

Page 17: 25 November 2013

17

Page 18: 25 November 2013

18

Page 19: 25 November 2013

19

Page 20: 25 November 2013

20

Page 21: 25 November 2013

21

Page 22: 25 November 2013

22

Page 23: 25 November 2013

23

Page 24: 25 November 2013

24

SUMMARY (general public)

Magnetic Field 50/60 HzSRD (SAR & magnetic/electric) Terminals (SAR)Far Fields (power density)

Page 25: 25 November 2013

25

Static Magnetic Field (50/60 Hz)

short period of time 1000 mG

constant exposure 2 mG

Page 26: 25 November 2013

26

SAR (W/kg) whole body head ICNIRP 0.08 2.0 IEEE ANSI 0.08 1.6 CODE 6 0.08 1.6 SAR measurements are not practical under 100 MHz

Page 27: 25 November 2013

27

0.5 MHz H (A/m) E (V/m)________ ICNIRP 0.73/f = 18 mG 87 V/m IEEE ANSI 16.3/f = 410 mG 614 V/mCODE 6 2.2 A/m = 27 mG 280 V/m

6.78 MHz H (A/m) E (V/m)________ ICNIRP 0.73/f = 1.3 mG 87/f = 33 V/m IEEE ANSI 16.3/f = 30 mG 824/f = 121 V/mCODE 6 2.2/f = 4 mG 280/f = 41 V/m

13.56 MHz H (A/m) E (V/m)________ ICNIRP 0.073 A/m = 1 mG 28 V/m IEEE ANSI 16.3/f = 15 mG 824/f = 60 V/mCODE 6 2.2/f = 2 mG 28 V/m

27.12 MHz H (A/m) E (V/m)_________ ICNIRP 0.073 A/m = 1 mG 28 V/m IEEE ANSI 16.3/f = 7 mG 824/f = 30 V/mCODE 6 2.2/f = 1 mG 28 V/m

Short Range Devices

1 A/m = 12.56 mG

Page 28: 25 November 2013

28

S(mW/cm²)_______________ 0.4 to 2

ICNIRP f/2000 (400-2000 MHz) 1 (f>2000 MHz) IEEE ANSI f/1500 (300-3000 MHz)CODE 6 f/1500 (300-1500 MHz) 1 (f>1500 MHz)

Far Field 800-2700 MHz