29 cfr 1910.304(f)(4); or 29 cfr 1910.304(f)(5)(v); or 29 cfr 1910.334(a)(3)(i)

18
•29 CFR 1910.304(f)(4); or •29 CFR 1910.304(f)(5)(v); or •29 CFR 1910.334(a)(3)(i) Portable electric equipment must be grounded (unless double insulated type).

Upload: wynne-keller

Post on 03-Jan-2016

200 views

Category:

Documents


4 download

DESCRIPTION

29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or 29 CFR 1910.334(a)(3)(i) Portable electric equipment must be grounded (unless double insulated type). 29 CFR 1910.303(g)(1) & 1910.303(b)(2) – Maintain ready access to panel & repair panel door. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: 29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or  29 CFR 1910.334(a)(3)(i)

•29 CFR 1910.304(f)(4); or•29 CFR 1910.304(f)(5)(v); or •29 CFR 1910.334(a)(3)(i)Portable electric equipment must be grounded (unless double insulated type).

Page 2: 29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or  29 CFR 1910.334(a)(3)(i)

•29 CFR 1910.303(g)(1) & 1910.303(b)(2) – Maintain ready access to panel & repair panel door.

•29 CFR 1910.305(b)(2) – Cover open junction box.

•29 CFR 1910.157(c)(1) – Do not block fire extinguisher.

Page 3: 29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or  29 CFR 1910.334(a)(3)(i)

29 CFR 1910.219(d)(1) & 1910.219(e)(1) Guard belt and pulleys.

Page 4: 29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or  29 CFR 1910.334(a)(3)(i)

29 CFR 1910.151(c) – Provide immediate access to emergency eyewash; maybe need an emergency shower.29 CFR 1910.22(a)(1) – Maintain clean & orderly workspace.More…

Page 5: 29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or  29 CFR 1910.334(a)(3)(i)

29 CFR 1926.1053(b)(13) – construction29 CFR 1910.25(d)(2)(xii) – general industry

Top of stepladder must not be used as a step.

Page 6: 29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or  29 CFR 1910.334(a)(3)(i)

•29 CFR 1910.157(c)(1)

Do not block fire extinguisher.

Page 7: 29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or  29 CFR 1910.334(a)(3)(i)

29 CFR 1910.23(c)(1)

Open-sided floor or platform 4 feet or more above adjacent floor or ground level must have guardrail except where there is entrance to a ramp, stairway, or fixed ladder.

Page 8: 29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or  29 CFR 1910.334(a)(3)(i)

29 CFR 1926.405(b)(1) – construction29 CFR 1910.305(b)(1) – general industry

Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed.

Page 9: 29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or  29 CFR 1910.334(a)(3)(i)

29 CFR 1910.178(g)(12)

Tools and other metallic objects shall be kept away from the top of uncovered batteries.

Page 10: 29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or  29 CFR 1910.334(a)(3)(i)

General Duty Clause

Employer must provide a safe surface from which to work.

Page 11: 29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or  29 CFR 1910.334(a)(3)(i)

29 CFR 1926.501(b)(4)(i)

Each employee on walking/working surfaces shall be protected from falling through holes more than 6 feet above lower levels…

Page 12: 29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or  29 CFR 1910.334(a)(3)(i)

•29 CFR 1910.106(e)(2)(iv) or 1910.106(e)(2)(ii) and

•29 CFR 1910.1200(f)(5)

Containers must be closed and labeled…more…

Page 13: 29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or  29 CFR 1910.334(a)(3)(i)

•29 CFR 1910.1030(d)(4)(iii)(A)(3)(i)

Prevent protrusion of contaminated sharps.

Page 14: 29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or  29 CFR 1910.334(a)(3)(i)

29 CFR 1926.1052(c)(1) Stairways with four or more risers or higher than 30” must be equipped with a stair-rail system along each unprotected side or edge.

Page 15: 29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or  29 CFR 1910.334(a)(3)(i)

•29 CFR 1910.134(h)(1)-(4) & 1910.94(a)(5)(iv)

Abrasive blasting respirator must be cleaned, stored in a clean environment, inspected, and repaired.

Page 16: 29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or  29 CFR 1910.334(a)(3)(i)

•29 CFR 1910.305(g)(1)(iii)

Flexible cord is not to be used as a substitute for fixed wiring.

Page 17: 29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or  29 CFR 1910.334(a)(3)(i)

•29 CFR 1910.213(h)(1) & (h)(4)

Radial arm saw needs lower guard and saw blade needs to automatically return to the starting position when released.

Page 18: 29 CFR 1910.304(f)(4); or 29 CFR 1910.304(f)(5)(v); or  29 CFR 1910.334(a)(3)(i)

29 CFR 1910.23(c)(1) and 1910.178(l)(4)

Employee must be provided a safe work surface with guardrails; employee needs refresher forklift training.