Means of EgressExit RoutesSubpart E

الهروب مسالكFrom

29 CFR 1910.35

To

29 CFR 1910.38

Page 2: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

المقدمة

• This Subpart is about ensuring that when people need to have a safe and efficient means of leaving a building or facility under emergency situations, that means will be there and they will have minimal problems finding it and using it.

• The entire Subpart E is promulgated from NFPA 101 Life Safety Code.

وسائل • وجود من للتأكدمخارج و آمنة هروب

إلخراج كافية للطوارىءفى المبنى شاغلى

الطوارىء حاالتلهذه • المرجع

: هو NFPAالمواصفاتالمواصفات 101 وهى

األرواح بإنقاذ الخاصة

Page 3: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

تعريفات29 CFR 1910.35

• Means of Egress:It is a continuous and unobstructed way of exit travel from any point in a building or structure to a public way, and consists of three separate and distinct parts:

1- The way of exit access2- The Exit,3- The exit discharge.

•: الهروب مسالكاإلنتقال • مسارات هى

شاغلو يسلكها التىبها يوجد وال المبنى

أية من عوائق أيةإلى بالمبنى نقطة

وتتكون العام الطريق: أجزاء ثالثة من

إلى 1. الوصول مسارالمخرج

المخرج2.

المخرج 3. صرف منفذ

Page 4: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

إلى الوصول مسارالمخرج

Page 5: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

المخرج

Page 6: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

المخرج صرف منفذ

Page 7: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Exit Access الوصول مسار للمخرج

Is that portion of a means of egress which leads to an entrance to an exit

Page 8: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Access to ExitsMirrors must not be placed on or near exit doors

مرا تركيب الطوارىء ياعدم مخارج من بالقرب تRoutes of exit access must never be toward a high

hazard location, unless effectively shielded أماكن خالل من يكون أال يجب المخرج إلى الطريق

. عزلها تم قد األماكن هذه تكن لم ما الخطورة عاليةMinimum width of any way of exit access is 28 inches

عن عرضه يقل أال يجب المخرج إلى 28الطريق(70بوصة ) سم

Page 9: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38
Page 10: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Exterior Routes of Exit Access

Permanent, reasonably straight route of travel للمخرج للوصول الحركة مسارات تكون أن يجب

مستقيمة مسارات تكون أن ويفضل دائمة مساراتNo obstructions of exterior access route

للوصول الحركة مسارات فى عوائق أية توجد أال يجبللمخرج

No dead ends longer than 20 feet إلى الوصول ومسار المسدودة النهاية بين المسافة

مسافة تسمى القريب المخرج مدخل أو المخرجعن تزيد أال يجب والتى الميتة (6قدم )20النهاية متر

Page 11: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Unobstructed Access

– Maintain exit routes free of obstructions

– Exit route cannot require travel to a dead end

– Exit route cannot go through a room that might be locked

Page 12: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38
Page 13: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38
Page 14: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38
Page 15: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38
Page 16: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Exit Route Capacityand Dimensions

• Must support the maximum permitted occupant load for each floor served

• Capacity must not decrease in the direction of exit route travel to the exit discharge

• Ceiling must be at least 7-½ ft. high with no projection reaching a point less than 6 ft.-8 in. from floor

• An exit access must be at least 28 in. wide at all points

Page 17: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Exit routes must have adequate capacity & size

• Exit routes must be at least:– 6 feet, 8 inches high– 28 inches wide

7b

Page 18: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Exit Route Capacity and Dimensions

• Ceiling must be at least 7-½ ft. high with no projection reaching a point less than 6 ft.- 8 in. from floor

• An exit access must be at least 28 in. wide at all points

1910.36 (g)(1) and (2)

7-½ ft.

6 ft.- 8 in.

Page 19: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

ExitالمخرجIs that portion of a means of egress which is separated from all other spaces of the building or structure by

construction or equipment to provide a protected way of travel to the exit discharge

Page 20: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Means of Egress, General29 CFR 1910.37

• Protective Enclosure of Exits:

When an exit is protected by separation from

Other parts of the building, the separating

Construction shall meet the following:

1- Three Stories or less – 1hr. Fire resistance

2- Four or more stories – 2hrs. Fire resistance

Page 21: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

One - hour fire resistance - rating: three or fewer stories

Exit Routes:Basic Requirements

An exit must be separated by fire resistant materials.

1910.36(a)(2)

Exit enclosure

Two - hour fire resistance – rating for four or more stories.

Page 22: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Three Stories or Less

Page 23: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Four Stories or More

Page 24: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Positive Pressure - Stairs

Page 25: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38
Page 26: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

المخرج صرف ExitمنفذDischarge

Is that portion of a means of egress between the termination of an exit and a public way.

Page 27: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Exit discharge. . . must lead directly outside or to a street,

walkway, refuge area, public way, or open space with access to the outside . . .(This area) must be large enough . . .

Fabricating shop

Offices Storage

Exit access

Exit

Discharge

1910.36 (c)(1) and (2)

Exit

Discharge

Page 28: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

29 CFR – 1910.36General Requirements

• Requirements that apply to all buildings:

1. Shall have exits sufficient for prompt and convenient escape of occupants in emergency.

2. Building structure shall not cause danger to occupants during period necessary for escape.

Page 29: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Continued

3-There shall be no locks or devices to prevent

emergency egress except in specialized facilities.

4-Means of egress shall be clearly visible and understandable to occupants who are physically and mentally capable to know the direction of escape.

5-Minimum ceiling height of 7 feet, 6 inches

6- Projections from the ceiling )lights, etc.( must be at least 6 feet, 8 inches from the floor

Page 30: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Emergency exit locked

Page 31: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38
Page 32: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38
Page 33: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38
Page 34: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38
Page 35: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38
Page 36: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Continued

7- Any doorway or passageway not constituting an exit or way to occupants to reach an exit, shall be clearly marked “Not an Exit”.

8- Adequate and reliable illumination shall be provided for all exit facilities in every building or structure.

9- Signs clearly visible with the word “EXIT” in plain letters at least 6 inches high and at least a ¾” stroke width

Page 37: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Exit Marking

• Each exit must be clearly visible and marked with an “Exit” sign

• Each exit route door must be free of decorations or signs that obscure the visibility of the door

Page 38: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Exit routes must be marked

• Each exit must be clearly visible and marked with a sign that says:

9a

Page 39: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38
Page 40: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Not an Exit

Page 41: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Exit Markings Illuminated by a light source at least 5 foot-

candles on the illuminated surface

Exit signs are not to be obscured by furnishings, decorations, etc.

Page 42: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Requirements for alarm systems

• Workplaces must have operable employee alarm systems

• Alarms must have distinctive signals to warn employees of fire or other emergencies

10a

Page 43: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Maintenance

• Maintenance is important to prevent protective device failures or impeded travel during an emergency.

• Every required exit, way of approach thereto, and way of travel from the exit into the street or open space shall be continuously maintained free of all obstructions or impediments to full instant use in the case of fire or other emergency.

Page 44: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Maintenance

• Every automatic sprinkler system, fire detection and alarm system, exit lighting, fire door, and other item or equipment, where provided, shall be continuously in proper operating condition.

Page 45: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Maintenance requirements

• Keep the following in proper working order:– sprinkler systems– alarm systems– fire doors– exit lighting– other safeguards to

protect employees

11b

Page 46: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38
Page 47: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

GENERAL GUIDELINESWidth and capacity of means of egress

Level egress components: 100 persons/unit )Including Class A ramps(

Inclined egress components: 60 persons/unit )Including Class B ramps(

LESSON 2

Page 48: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Exit Routes Width and Capacity

• Capacity is a measure of persons per exit width. To understand capacity, it is important to understand the term exit width.

• Means of egress shall be measured in exit width units of 22 inches.

• Fractions of an exit width unit shall be counted as:

– Zero if the fractional unit is less than 12 inches

– One-half if the fraction is greater than 12 inches and less than 22 inches.

Page 49: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Egress Capacity and Occupant Load اإلشغال حمل

• When capacity has been determined for each means of egress, the projected occupant load for the means of egress must be calculated.

• Capacity of means of egress shall be sufficient for occupant load of any space served.

Page 50: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Continued

• Occupant Load is the maximum number of persons that may be in a space at any time.

• The occupant load in any building thereof shall not be assumed to be less than the number determined by dividing the floor area assigned to that use by the occupant load factor for individual occupancies.

Page 51: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Continued

• Capacity of the exits at a floor can be based on individual floor occupant loads (not additive).

• Some important occupant load factors:

- Classroom area 20 Ft2 1.9 m2

- Research Labs 50 Ft2 4.6 m2

- Offices 100 Ft2 9.3 m2

- General and High

- Hazard industrial 100 Ft2 9.3 m2

Page 52: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Number of Means of Egress

• The minimum number of means of egress from any story or portion thereof shall be Two. )Remote from each other(

• The minimum number of means of egress:

• Occupant Load more than 500 but less than 1000: 3

• Occupant Load more than 1000: 4

Page 53: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Number of Means of Egress

Page 54: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

The number of exit routes must be adequate.

1910.36(b)

Normally two or more depending on

•the size of the building, •its occupancy, or •the arrangement of the workplace

Remotely located to provide options for evacuation

Page 55: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38
Page 56: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Travel Distance to Exits

• Distance to exits shall be measured from the most remote point subject to occupancy.

• Travel distance to at least one exit shall not exceed 200 Ft. (60 m) in buildings not sprinklered or exceed 250 Ft. (76 m) in buildings protected through – out by approved supervised Sprinkler System.

Page 57: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Travel Distance

Page 58: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Emergency Plans

Page 59: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38
Page 60: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38
Page 61: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38
Page 62: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

(b) Written and oral emergency action

plans. An emergency action plan must be in

writing, kept in the workplace, and available to employees for review.

However, an employer with 10 or fewer employees may

communicate the plan orally to employees.

Page 63: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

(c) Minimum elements of an emergency action plan.

An emergency action plan must include at a minimum:

(1) Procedures for reporting a fire or

other emergency;

Page 64: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

(c) Minimum elements of an emergency action plan.

(2) Procedures for emergency evacuation, including type of evacuation and exit route assignments;

Page 65: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

(c) Minimum elements of an emergency action plan.

(3) Procedures to be followed by employees who remain to

operate critical plant operations before they evacuate;

Page 66: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

(c) Minimum elements of an emergency action plan.

(4) Procedures to account for all employees after evacuation;

Verify that employees are safe.

Page 67: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Fire

(c) Minimum elements of an emergency action plan.

(5) Procedures to be followed by employees performing rescue or medical duties; and

Page 68: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

(c) Minimum elements of an emergency action plan.

(6) The name or job title of every employee

who may be contacted by employees who need more information about the plan or an explanation of their duties under the plan.

What do I do??

We do this!

Page 69: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

(d) Employee alarm system.

An employer must have and maintain an employee alarm system.

Page 70: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

(d) Employee alarm system.

. . .The employee alarm system must use a

distinctive signal for each purpose and

comply with the requirements in §

1910.165.

Page 71: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

(e) Training.

An employer must designate and train

employees to assist in a safe and orderly

evacuation of

other employees. EAP

Fire

Warden

Page 72: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

(f) Review of emergency action plan.An employer must review the . . .

EAP. . . with each employee covered by the plan:

)1( When the plan is developed or the employee is assigned initially to a job;

)2( When the employee's responsibilities under the plan change; and

)3( When the plan is changed.

Informingemployees

EAPMe

MeToo

Page 73: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38
Page 74: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Emergency Action Plan

Know what to do BEFOREan emergency occurs!

Page 75: Means of Egress Exit Routes Subpart E مسالك الهروب From 29 CFR 1910.35 To 29 CFR 1910.38

Know where YOU are supposed to

go if an evacuation occurs.