3 installation equipments bcz85 series explosion-proof plug ......3 3/28 installation equipments...

6
3 3/28 Installation Equipments Catalogue number logic Plug and Sockets BCZ85 Ser ies Explosion-proof Plug and Socke ts Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2 Zone 21 and Zone 22 Four enclosure types; Four current ratings (16A, 32A, 63A, 125A); 3P, 4P or 5P. Plug can only be pulled out when switch is off; turn on the power after inserting the plug. Copper-free aluminium enclosure; powder coated external surface. Zones 1&2; 21&22 http:// www.waromgroup.com General Catalogue 01.01.2012 Z: Socket T: Plug BCZ 85 - / / / Pole number Rated voltage (V) Rated current (A) Design No. Explosion-proof plug and sockets 3P (2P+PE) 4P (3P+PE) 5P (3P+N+PE) 130: 100~130; 57/100~75/130 250: 200~250; 120/208~144/250 415: 380~415; 200/346~240/415 500: 480~500; 277/480~288/500 690: 600~690; 347/600~400/690

Upload: others

Post on 09-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 3 Installation Equipments BCZ85 Series Explosion-proof Plug ......3 3/28 Installation Equipments Catalogue number logic Plug and Sockets BCZ85 Series Explosion-proof Plug and Sockets

3

3/28

Installation Equipments

Catalogue number logic

Plug and Sockets

BCZ85 Series Explosion-proof Plug and Sockets

Explosion protection to

-CENELEC

-IEC

-NEC

Can be used in

Zone 1 and Zone 2

Zone 21 and Zone 22

Four enclosure types; Four current ratings (16A, 32A, 63A,

125A); 3P, 4P or 5P.

Plug can only be pulled out when switch is off; turn on the

power after inserting the plug.

Copper-free aluminium enclosure; powder coated external

surface.

Zones 1&2; 21&22

3

3/29

Plug and Sockets

BCZ85 Series Explosion-proof Plug and Sockets

http:// www.waromgroup.comGeneral Catalogue 01.01.2012 http:// www.waromgroup.comGeneral Catalogue 01.01.2012

Z: Socket

T: Plug

BCZ 85 - / / /

Pole number

Rated voltage (V)

Rated current (A)

Design No.

Explosion-proof plug and sockets

3P (2P+PE)

4P (3P+PE)

5P (3P+N+PE)

130: 100~130; 57/100~75/130

250: 200~250; 120/208~144/250

415: 380~415; 200/346~240/415

500: 480~500; 277/480~288/500

690: 600~690; 347/600~400/690

Selection table

Type Current(A)

BCZ85-16/ / 100~130

200~250

100~130

200~250

380~415

480~500

600~690

57/100~75/130

120/208~144/250

200/346~240/415

277/480~288/500

347/600~400/690

200~250

200~250

380~415

480~500

600~690

120/208~144/250

200/346~240/415

277/480~288/500

347/600~400/690

200~250

380~415

480~500

600~690

120/208~144/250

200/346~240/415

200~250

380~415

480~500

600~690

120/208~144/250

200/346~240/415

Schematic diagram

hOrdering

codeWeight (kg)

Pole number

Voltage (V)

Colour

32

125

16

BCZ85-32/ /

2P+PE

3P+PE

3P+N+PE

2P+PE

3P+PE

3P+N+PE

3P+PE

3P+N+PE

3P+PE

3P+N+PE

4

6

4

9

6

7

5

4

9

6

7

5

6

9

6

7

5

9

6

7

5

9

6

7

5

9

6

9

6

7

5

9

6

Yellow

Blue

Yellow

Blue

Red

Black

Black

Yellow

Blue

Red

Black

Black

Blue

Blue

Red

Black

Black

Blue

Red

Black

Black

Blue

Red

Black

Black

Blue

Red

Blue

Red

Black

Black

Blue

Red

30147

30148

30149

30150

30151

30152

30153

30154

30155

30156

30157

30158

30159

30160

30161

30162

30163

30164

30165

30166

30167

30168

30169

30170

30171

30172

30173

30174

30175

30176

30177

30178

30179

2.60

2.60

2.60

2.60

2.60

2.60

2.60

2.60

2.60

2.60

2.60

2.60

3.40

3.40

3.40

3.40

3.40

3.40

3.40

3.40

3.40

4.50

4.50

4.50

4.50

4.50

4.50

20.0

20.0

20.0

20.0

20.0

20.0

63

BCZ85-63/ /

BCZ85-125/ /

Page 2: 3 Installation Equipments BCZ85 Series Explosion-proof Plug ......3 3/28 Installation Equipments Catalogue number logic Plug and Sockets BCZ85 Series Explosion-proof Plug and Sockets

3

3/28

Installation Equipments

Catalogue number logic

Plug and Sockets

BCZ85 Series Explosion-proof Plug and Sockets

Explosion protection to

-CENELEC

-IEC

-NEC

Can be used in

Zone 1 and Zone 2

Zone 21 and Zone 22

Four enclosure types; Four current ratings (16A, 32A, 63A,

125A); 3P, 4P or 5P.

Plug can only be pulled out when switch is off; turn on the

power after inserting the plug.

Copper-free aluminium enclosure; powder coated external

surface.

Zones 1&2; 21&22

3

3/29

Plug and Sockets

BCZ85 Series Explosion-proof Plug and Sockets

http:// www.waromgroup.comGeneral Catalogue 01.01.2012 http:// www.waromgroup.comGeneral Catalogue 01.01.2012

Z: Socket

T: Plug

BCZ 85 - / / /

Pole number

Rated voltage (V)

Rated current (A)

Design No.

Explosion-proof plug and sockets

3P (2P+PE)

4P (3P+PE)

5P (3P+N+PE)

130: 100~130; 57/100~75/130

250: 200~250; 120/208~144/250

415: 380~415; 200/346~240/415

500: 480~500; 277/480~288/500

690: 600~690; 347/600~400/690

Selection table

Type Current(A)

BCZ85-16/ / 100~130

200~250

100~130

200~250

380~415

480~500

600~690

57/100~75/130

120/208~144/250

200/346~240/415

277/480~288/500

347/600~400/690

200~250

200~250

380~415

480~500

600~690

120/208~144/250

200/346~240/415

277/480~288/500

347/600~400/690

200~250

380~415

480~500

600~690

120/208~144/250

200/346~240/415

200~250

380~415

480~500

600~690

120/208~144/250

200/346~240/415

Schematic diagram

hOrdering

codeWeight (kg)

Pole number

Voltage (V)

Colour

32

125

16

BCZ85-32/ /

2P+PE

3P+PE

3P+N+PE

2P+PE

3P+PE

3P+N+PE

3P+PE

3P+N+PE

3P+PE

3P+N+PE

4

6

4

9

6

7

5

4

9

6

7

5

6

9

6

7

5

9

6

7

5

9

6

7

5

9

6

9

6

7

5

9

6

Yellow

Blue

Yellow

Blue

Red

Black

Black

Yellow

Blue

Red

Black

Black

Blue

Blue

Red

Black

Black

Blue

Red

Black

Black

Blue

Red

Black

Black

Blue

Red

Blue

Red

Black

Black

Blue

Red

30147

30148

30149

30150

30151

30152

30153

30154

30155

30156

30157

30158

30159

30160

30161

30162

30163

30164

30165

30166

30167

30168

30169

30170

30171

30172

30173

30174

30175

30176

30177

30178

30179

2.60

2.60

2.60

2.60

2.60

2.60

2.60

2.60

2.60

2.60

2.60

2.60

3.40

3.40

3.40

3.40

3.40

3.40

3.40

3.40

3.40

4.50

4.50

4.50

4.50

4.50

4.50

20.0

20.0

20.0

20.0

20.0

20.0

63

BCZ85-63/ /

BCZ85-125/ /

Page 3: 3 Installation Equipments BCZ85 Series Explosion-proof Plug ......3 3/28 Installation Equipments Catalogue number logic Plug and Sockets BCZ85 Series Explosion-proof Plug and Sockets

Dimension drawings (all dimensions in mm) - subject to alteration

3

3/30

Plug and Sockets

BCZ85 Series Explosion-proof Plug and Sockets

Technical data

Explosion protection

Gas explosion protection

Dust explosion protection

Certificates

Conformity to standards

Enclosure material

Enclosure colour

Exposed fastener

Rated voltage

Rated current

Pole number

Degree of protection

Ambient temperature

Cable entry of socket

Cable entry of plug

Cable gland (optional)

II 2 G Ex d IIC T6 Gb

II 2 D Ex t IIIC T80 Db IP66

Nemko 12 ATEX_____; FM (USA); GOST.R (Russia); IECEx; CQST(China)

EN 60079-0:2009, EN 60079-1:2007, EN 60079-31:2009

IEC 60079-0:2007, IEC 60079-1:2007, IEC 60079-31:2008

Copper-free aluminium; powder coated external surface

Window grey (RAL7040)

Stainless steel

Max. 690V AC

16A

3P (2P+PE), 4P (3P+PE), 5P (3P+N+PE)

IP66

-60 +55

2 x M25 x 1.5(3P/4P), 2 x M32 x 1.5(5P)

1 x M25 x 1.5(3P/4P) , 1 x M32 x 1.5(5P)

DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/20 25.

Explosion-proof plug and sockets BCZ85-16/ /

3

3/31

Plug and Sockets

BCZ85 Series Explosion-proof Plug and Sockets

http:// www.waromgroup.comGeneral Catalogue 01.01.2012 http:// www.waromgroup.comGeneral Catalogue 01.01.2012

Dimension drawings (all dimensions in mm) - subject to alteration155

21

0

80

65

10

5

7

165

30

8

BCZ85-16/ /3P

BCZ85-16/ /4P

Socket Plug

Plug and Sockets

180

25

0 14

0

75

9

192

35

0

Socket Plug

Plug and Sockets BCZ85-16/ /5P

18

3

94

16

379

Install on the

flameproof enclosure

Install on the

flameproof enclosure

BCZ85-32/ /

180

25

0 14

0

75

9

192

35

0

Socket Plug

Plug and Sockets

18

3

94

Install on the

flameproof enclosure

M84 1.5

15

2

Fla

me

pro

of E

nclo

su

re

Flameproof Thread

26

1

M98 1.5

Fla

me

pro

of E

nclo

su

re

Flameproof Thread

17

0

29

0

M98 1.5

Fla

me

pro

of E

nclo

su

re

Flameproof Thread

17

0

29

0

Technical data

Explosion protection

Gas explosion protection

Dust explosion protection

Certificates

Conformity to standards

Enclosure material

Enclosure colour

Exposed fastener

Rated voltage

Rated current

Pole number

Degree of protection

Ambient temperature

Cable entry of socket

Cable entry of plug

Cable gland (optional)

II 2 G Ex d IIC T6 Gb

II 2 D Ex t IIIC T80 Db IP66

Nemko 12 ATEX_____; FM (USA); GOST.R (Russia); IECEx; CQST(China)

EN 60079-0:2009, EN 60079-1:2007, EN 60079-31:2009

IEC 60079-0:2007, IEC 60079-1:2007, IEC 60079-31:2008

Copper-free aluminium; powder coated external surface

Window grey (RAL7040)

Stainless steel

Max. 690V AC

32A

3P (2P+PE), 4P (3P+PE), 5P (3P+N+PE)

IP66

-60 +55

2 x M32 x 1.5

1 x M32 x 1.5

DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/20 25.

Explosion-proof plug and sockets BCZ85-32/ /

Page 4: 3 Installation Equipments BCZ85 Series Explosion-proof Plug ......3 3/28 Installation Equipments Catalogue number logic Plug and Sockets BCZ85 Series Explosion-proof Plug and Sockets

Dimension drawings (all dimensions in mm) - subject to alteration

3

3/30

Plug and Sockets

BCZ85 Series Explosion-proof Plug and Sockets

Technical data

Explosion protection

Gas explosion protection

Dust explosion protection

Certificates

Conformity to standards

Enclosure material

Enclosure colour

Exposed fastener

Rated voltage

Rated current

Pole number

Degree of protection

Ambient temperature

Cable entry of socket

Cable entry of plug

Cable gland (optional)

II 2 G Ex d IIC T6 Gb

II 2 D Ex t IIIC T80 Db IP66

Nemko 12 ATEX_____; FM (USA); GOST.R (Russia); IECEx; CQST(China)

EN 60079-0:2009, EN 60079-1:2007, EN 60079-31:2009

IEC 60079-0:2007, IEC 60079-1:2007, IEC 60079-31:2008

Copper-free aluminium; powder coated external surface

Window grey (RAL7040)

Stainless steel

Max. 690V AC

16A

3P (2P+PE), 4P (3P+PE), 5P (3P+N+PE)

IP66

-60 +55

2 x M25 x 1.5(3P/4P), 2 x M32 x 1.5(5P)

1 x M25 x 1.5(3P/4P) , 1 x M32 x 1.5(5P)

DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/20 25.

Explosion-proof plug and sockets BCZ85-16/ /

3

3/31

Plug and Sockets

BCZ85 Series Explosion-proof Plug and Sockets

http:// www.waromgroup.comGeneral Catalogue 01.01.2012 http:// www.waromgroup.comGeneral Catalogue 01.01.2012

Dimension drawings (all dimensions in mm) - subject to alteration155

21

0

80

65

10

5

7

165

30

8

BCZ85-16/ /3P

BCZ85-16/ /4P

Socket Plug

Plug and Sockets

180

25

0 14

0

75

9

192

35

0

Socket Plug

Plug and Sockets BCZ85-16/ /5P

18

3

94

16

3

79

Install on the

flameproof enclosure

Install on the

flameproof enclosure

BCZ85-32/ /

180

25

0 14

0

75

9

192

35

0

Socket Plug

Plug and Sockets

18

3

94

Install on the

flameproof enclosure

M84 1.5

15

2

Fla

me

pro

of E

nclo

su

re

Flameproof Thread

26

1

M98 1.5

Fla

me

pro

of E

nclo

su

re

Flameproof Thread

17

0

29

0

M98 1.5

Fla

me

pro

of E

nclo

su

re

Flameproof Thread

17

0

29

0

Technical data

Explosion protection

Gas explosion protection

Dust explosion protection

Certificates

Conformity to standards

Enclosure material

Enclosure colour

Exposed fastener

Rated voltage

Rated current

Pole number

Degree of protection

Ambient temperature

Cable entry of socket

Cable entry of plug

Cable gland (optional)

II 2 G Ex d IIC T6 Gb

II 2 D Ex t IIIC T80 Db IP66

Nemko 12 ATEX_____; FM (USA); GOST.R (Russia); IECEx; CQST(China)

EN 60079-0:2009, EN 60079-1:2007, EN 60079-31:2009

IEC 60079-0:2007, IEC 60079-1:2007, IEC 60079-31:2008

Copper-free aluminium; powder coated external surface

Window grey (RAL7040)

Stainless steel

Max. 690V AC

32A

3P (2P+PE), 4P (3P+PE), 5P (3P+N+PE)

IP66

-60 +55

2 x M32 x 1.5

1 x M32 x 1.5

DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/20 25.

Explosion-proof plug and sockets BCZ85-32/ /

Page 5: 3 Installation Equipments BCZ85 Series Explosion-proof Plug ......3 3/28 Installation Equipments Catalogue number logic Plug and Sockets BCZ85 Series Explosion-proof Plug and Sockets

3

3/32

Plug and Sockets

BCZ85 Series Explosion-proof Plug and Sockets 3

3/33

Plug and Sockets

BCZ85 Series Explosion-proof Plug and Sockets

http:// www.waromgroup.comGeneral Catalogue 01.01.2012 http:// www.waromgroup.comGeneral Catalogue 01.01.2012

Technical data

Explosion protection

Gas explosion protection

Dust explosion protection

Certificates

Conformity to standards

Enclosure material

Enclosure colour

Exposed fastener

Rated voltage

Rated current

Pole number

Degree of protection

Ambient temperature

Cable entry of socket

Cable entry of plug

Cable gland (optional)

II 2 G Ex d IIC T6 Gb

II 2 D Ex t IIIC T80 Db IP66

Nemko 12 ATEX_____; FM (USA); GOST.R (Russia); IECEx; CQST(China)

EN 60079-0:2009, EN 60079-1:2007, EN 60079-31:2009

IEC 60079-0:2007, IEC 60079-1:2007, IEC 60079-31:2008

Copper-free aluminium; powder coated external surface

Window grey (RAL7040)

Stainless steel

Max. 690V AC

63A

4P (3P+PE), 5P (3P+N+PE)

IP66

-60 +55

2 x M40 x 1.5

1 x M40 x 1.5

DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/20 25.

Explosion-proof plug and sockets BCZ85-63/ /

Dimension drawings (all dimensions in mm) - subject to alteration

BCZ85-63/ /

Technical data

Explosion protection

Gas explosion protection

Dust explosion protection

Certificates

Conformity to standards

Enclosure material

Enclosure colour

Exposed fastener

Rated voltage

Rated current

Pole number

Degree of protection

Ambient temperature

Cable entry of socket

Cable entry of plug

Cable gland (optional)

II 2 G Ex d IIC T6 Gb

II 2 D Ex t IIIC T80 Db IP66

Nemko 12 ATEX_____; FM (USA); GOST.R (Russia); IECEx; CQST(China)

EN 60079-0:2009, EN 60079-1:2007, EN 60079-31:2009

IEC 60079-0:2007, IEC 60079-1:2007, IEC 60079-31:2008

Copper-free aluminium; powder coated external surface

Window grey (RAL7040)

Stainless steel

Max. 690V AC

125A

4P (3P+PE), 5P (3P+N+PE)

IP66

-60 +55

1 x M63 x 1.5

1 x M50 x 1.5

DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/20 25.

Explosion-proof plug and sockets BCZ85-125/ /

240

50

5

213

32

5

18685

13

18

0

106

25

0

Socket Plug

Plug and Sockets

Dimension drawings (all dimensions in mm) - subject to alteration

BCZ85-125/ /

290

30

0

330

67

5

270

35

0

240

13

Page 6: 3 Installation Equipments BCZ85 Series Explosion-proof Plug ......3 3/28 Installation Equipments Catalogue number logic Plug and Sockets BCZ85 Series Explosion-proof Plug and Sockets

3

3/32

Plug and Sockets

BCZ85 Series Explosion-proof Plug and Sockets 3

3/33

Plug and Sockets

BCZ85 Series Explosion-proof Plug and Sockets

http:// www.waromgroup.comGeneral Catalogue 01.01.2012 http:// www.waromgroup.comGeneral Catalogue 01.01.2012

Technical data

Explosion protection

Gas explosion protection

Dust explosion protection

Certificates

Conformity to standards

Enclosure material

Enclosure colour

Exposed fastener

Rated voltage

Rated current

Pole number

Degree of protection

Ambient temperature

Cable entry of socket

Cable entry of plug

Cable gland (optional)

II 2 G Ex d IIC T6 Gb

II 2 D Ex t IIIC T80 Db IP66

Nemko 12 ATEX_____; FM (USA); GOST.R (Russia); IECEx; CQST(China)

EN 60079-0:2009, EN 60079-1:2007, EN 60079-31:2009

IEC 60079-0:2007, IEC 60079-1:2007, IEC 60079-31:2008

Copper-free aluminium; powder coated external surface

Window grey (RAL7040)

Stainless steel

Max. 690V AC

63A

4P (3P+PE), 5P (3P+N+PE)

IP66

-60 +55

2 x M40 x 1.5

1 x M40 x 1.5

DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/20 25.

Explosion-proof plug and sockets BCZ85-63/ /

Dimension drawings (all dimensions in mm) - subject to alteration

BCZ85-63/ /

Technical data

Explosion protection

Gas explosion protection

Dust explosion protection

Certificates

Conformity to standards

Enclosure material

Enclosure colour

Exposed fastener

Rated voltage

Rated current

Pole number

Degree of protection

Ambient temperature

Cable entry of socket

Cable entry of plug

Cable gland (optional)

II 2 G Ex d IIC T6 Gb

II 2 D Ex t IIIC T80 Db IP66

Nemko 12 ATEX_____; FM (USA); GOST.R (Russia); IECEx; CQST(China)

EN 60079-0:2009, EN 60079-1:2007, EN 60079-31:2009

IEC 60079-0:2007, IEC 60079-1:2007, IEC 60079-31:2008

Copper-free aluminium; powder coated external surface

Window grey (RAL7040)

Stainless steel

Max. 690V AC

125A

4P (3P+PE), 5P (3P+N+PE)

IP66

-60 +55

1 x M63 x 1.5

1 x M50 x 1.5

DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/20 25.

Explosion-proof plug and sockets BCZ85-125/ /

240

50

5

213

32

5

18685

13

18

0

106

25

0

Socket Plug

Plug and Sockets

Dimension drawings (all dimensions in mm) - subject to alteration

BCZ85-125/ /

290

30

0

330

67

5

270

35

0

240

13