36” downdraft hood proud mounting · if you would like to reduce the environmental impact of your...
TRANSCRIPT
![Page 1: 36” Downdraft Hood Proud Mounting · If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed](https://reader034.vdocument.in/reader034/viewer/2022042918/5f5df8da859cc67471242f96/html5/thumbnails/1.jpg)
36” Downdraft HoodProud Mounting
DA 6891
8mieleusa.comSpecification Sheets TRS 08122019
Shown: KM 6375 with DA 6891 Flush MountedPlease note: This information is subject to change
![Page 2: 36” Downdraft Hood Proud Mounting · If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed](https://reader034.vdocument.in/reader034/viewer/2022042918/5f5df8da859cc67471242f96/html5/thumbnails/2.jpg)
Page 2 of 14
SPECIFICATIONS
Overall Unit Dimensions 36” (915 mm) W x 2511/16” (652 mm) H (Unextended) x 43/4” (120 mm) D
Overall Canopy Height 16” (406 mm)
Built-In
Minimum Opening Dimensions 3115/16” (812 mm) W x 2513/16” (656 mm) H (Including Countertop) x 41/4” (108 mm) D
Fan
Fan Speeds 4
Maximum CFM DA 6891 w/DAG 600 g 500 CFMDA 6891 w/DAG 1000 g 1000 CFM
Duct
Duct Diameter DAG 600 g 6” (150 mm)DAG 1000 g 10” (254 mm)
Electrical
Electrical Requirements 120V, 60Hz,15A
Power Cable Ventilation system must be hard wired
Shipping
Shipping Weight 74 lbs (33.6 kg)
Shipping Dimensions 427/8” W x 305/8” H x 107/8” D
Support
Call Miele (800) 999-1360
Miele Website 8www.mieleusa.com
20/20 Link 82020technologies.com
36” Downdraft HoodProud Installation
DA 6891 w/DAG600Item DA6891+internal
DA 6891 w/DAG1000Item DA6891+external
![Page 3: 36” Downdraft Hood Proud Mounting · If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed](https://reader034.vdocument.in/reader034/viewer/2022042918/5f5df8da859cc67471242f96/html5/thumbnails/3.jpg)
Page 3 of 14
STANDARD ACCESSORIES
Two Support Brackets for One or Two Cutout(s) Instal-
lation
Single Support Bracket for One Cutout Installation
36” Downdraft HoodProud Installation
DUU 151
Recirculation kit for use with DAG 600
DUU 150
Recirculation kit for use with DAG 600
OPTIONAL ACCESSORIES
DAG 600
500 CFM Internal Blower
R2000
Reducing collar limits air flow to less than 300 CFM
with DAG 600
DAG 1000
1000 CFM External Blower
DUU 2900
Recirculation kit for use with DAG 600
DKF18-900
Replacement OdorFree charcoal filter
(Used with DUU 2900)
DKF22-900
Replacement OdorFree charcoal filter
(Used with DUU 150 and DUU 151)
![Page 4: 36” Downdraft Hood Proud Mounting · If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed](https://reader034.vdocument.in/reader034/viewer/2022042918/5f5df8da859cc67471242f96/html5/thumbnails/4.jpg)
PRODUCT SPECIFICATIONS
Page 4 of 14
36” Downdraft HoodProud Installation
![Page 5: 36” Downdraft Hood Proud Mounting · If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed](https://reader034.vdocument.in/reader034/viewer/2022042918/5f5df8da859cc67471242f96/html5/thumbnails/5.jpg)
OPTION 1ONE CUTOUT INSTALLATION SPECIFICATIONSCutout Dimensions for One (1) Cutout
- Proud Mount Installation
Page 5 of 14
36” Downdraft HoodProud Installation
![Page 6: 36” Downdraft Hood Proud Mounting · If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed](https://reader034.vdocument.in/reader034/viewer/2022042918/5f5df8da859cc67471242f96/html5/thumbnails/6.jpg)
OPTION 1INSTALLATION SPECIFICATIONSOne Cutout Options with Support Bracket(s) (Included)
The following situation, the support bracket should be replaced with two small angle brackets. The downdraft extractor and cooktop are installed in a common cutout, but the cutout for the cooktop is narrower k.
Single Support Bracket
Two Angle Support Brackets
A support bracket is mounted on the downdraft extractor. It serves as a support for the cooktop when the downdraft extractor and the cooktop are installed in a common cutout j.
Page 6 of 14
36” Downdraft HoodProud Installation
![Page 7: 36” Downdraft Hood Proud Mounting · If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed](https://reader034.vdocument.in/reader034/viewer/2022042918/5f5df8da859cc67471242f96/html5/thumbnails/7.jpg)
OPTION 2TWO CUTOUT INSTALLATION SPECIFICATIONSCutout Dimensions for Two (2) Cutout
- Proud Mount Installation
- Allows for Installation with Proud Mounted Downdraft in Combination with Flush or Proud Mounted Combisets and Cooktops
Page 7 of 14
36” Downdraft HoodProud Installation
![Page 8: 36” Downdraft Hood Proud Mounting · If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed](https://reader034.vdocument.in/reader034/viewer/2022042918/5f5df8da859cc67471242f96/html5/thumbnails/8.jpg)
Two small angle brackets are mounted on the downdraft extractor. They serve as a support for the downdraft extractor when the downdraft extractor and cooktop are installed in two separate cutouts.
OPTION 2INSTALLATION SPECIFICATIONSTwo (2) Cutout Option with Support Brackets (Included)
Two Angle Support Brackets
Page 8 of 14
36” Downdraft HoodProud Installation
![Page 9: 36” Downdraft Hood Proud Mounting · If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed](https://reader034.vdocument.in/reader034/viewer/2022042918/5f5df8da859cc67471242f96/html5/thumbnails/9.jpg)
EXTERNAL BLOWER DAG 1000(Optional Accessory)
Page 9 of 14
36” Downdraft HoodProud Installation
![Page 10: 36” Downdraft Hood Proud Mounting · If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed](https://reader034.vdocument.in/reader034/viewer/2022042918/5f5df8da859cc67471242f96/html5/thumbnails/10.jpg)
EXTERNAL BLOWER DAG 1000 - CONTINUED(Optional Accessory)
Page 10 of 14
36” Downdraft HoodProud Installation
![Page 11: 36” Downdraft Hood Proud Mounting · If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed](https://reader034.vdocument.in/reader034/viewer/2022042918/5f5df8da859cc67471242f96/html5/thumbnails/11.jpg)
Recirculation Kit DUU 2900(Optional Accessory)
Ventilation Cutout
Page 11 of 14
36” Downdraft HoodProud Installation
![Page 12: 36” Downdraft Hood Proud Mounting · If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed](https://reader034.vdocument.in/reader034/viewer/2022042918/5f5df8da859cc67471242f96/html5/thumbnails/12.jpg)
Recirculation Kit DUU 150(Optional Accessory)
Page 12 of 14
36” Downdraft HoodFlush Installation
![Page 13: 36” Downdraft Hood Proud Mounting · If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed](https://reader034.vdocument.in/reader034/viewer/2022042918/5f5df8da859cc67471242f96/html5/thumbnails/13.jpg)
Recirculation Kit DUU 151(Optional Accessory)
Page 13 of 14
36” Downdraft HoodFlush Installation
![Page 14: 36” Downdraft Hood Proud Mounting · If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed](https://reader034.vdocument.in/reader034/viewer/2022042918/5f5df8da859cc67471242f96/html5/thumbnails/14.jpg)
Reducing Collar(Optional Accessory)
If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed. It reduces the air flow to less than 300 CFM in use with DAG 600. Check local building codes for maximum CFM requirements.
Specification Sheets TRS 08122019Page 14 of 14
36” Downdraft HoodProud Installation