Model NO.D HT-329MKL1) D HT-329M2(L2)HT-329M3(L3) DHT-329M4(L4)

HT329M1~M4(L1~L4) LCD Screen Mini Wireless Digital PMS

INDEX

1. INTRODUCTION 1

2. CAUTION 2-3

3. INDICATOR AND CONTROLS 4-5

4. PREPARATION FOR USE 6

5. STANDARD ACCESSORIES 7

6. TROUBLESHOOTING 8-9

7. TECHNICAL SPECIFICATIONS 10

8. REFERENCE APPLICATION 11-12

9. WARRANTY 13

D HT329M1(L1) Q HT329M2(L2)D HT329M3(L3) D HT329M4(L4)

A Before using the instrument, please read!\e rat ing inst ruct ions care fu l ly !

INTRODUCTION

What is PMS? PMS stands for Powered Muscle Stimulator

The PMS unit is a battery powered device that transmits a

mild electric impulses through conductive self-adhesive electrodes.

These impulses pass through the skin to underlying nerve

fibers and muscles to modify the perception of pain.PMS is a safe and effective drug free method of reducing pain

that is in use by physicians and in pain clinics all over the world.

The Home Tech PMS system unit is a high quality electric

therapy stimulator that you can use in your home.

Pain therapy with PMS. The PMS provided may be

effective in helping to manage particular pain problems. Its

physiological reasonings are explained as follows:

a. Gate control theory.

b. The endorphin theory.

c. Nerve block theory.

d. Pumping effect.

e. Placebotheory.

No matter what pain theory is applied, PMS is both safe and

effective in pain management for many patients with pain.

• Re-use of the electrode by another user could cause the

cross-infection of skin disease.

• The device's shelf-life is 3 years.

• This device is warranted for a period of one year from the

date of purchase by the original buyer.

• The product complies with the electromagnetic compatibility

requirement of EN60601-1-2 as specified in EEC Directive

93/42/EEC as amended by 2007/47/EC.

• Operation in close proximity ( e.g. 1m ) to shortwave or

microwave therapy equipment may produce instability in

the stimulator output.(IEC601-2-10).

• Don'tapply the electrode pad to broken skin.

• Don't abruptly stop or reset the device. It may cause the

user discomfort.

• Don't re-use too many times, if the electrode has deteriorated.

The user may feel irritation, hotness or no effect.

• PMS should not be used in the presence of cardiac

pace make rsordur ing pregnancy.

CAUTION I-» Keep out of the reach of children.

• The contact period is within 30 min on the same part of

patient's body for each usage, but the contact period can

be adjusted by the physician or therapist.

' Don't stimulate over carotid sinus nerves or around the mouth

region.

1 Always use the specified accessories in the manual. The

use of other parts not approved by the manufacturer may

cause harm.

1 For service information like circuit diagram, parts list etc.,

please contact the distributers.

> To clean the unit apply with water or alcohol after treatment.

1 Clean and dry the area to which the electrodes are to be

applied with water or alcohol prior to application of the

electrode.

I-HT329M1(L1)

s

LCD Screen

On/Raise Switch

L Snap Connector

-Battery Housing

HT329M2(L2)

LCD Screen

L SnapConnector

- Battery Housing

3 INDICATORANDCONTROLS

HT329M3(L3)

-Snap Connector

Battery Housing

LCD Screen

On/Raise Switch

HT329M4(L4)

L Snap Connector

- Battery Housing

LCD Screen

On/Raise Switch

PREPARATION FOR USE

1. Insert 3V battery, making sure it is positioned correctly.

Connect to the pad and place on the skin area.

2. Touch the right button to turn on unit and raise density level

or touch the left button to lower the density level and turn off

the unit.

3. Turn on the unit. The LCD screen display will show P1 (touch

mode button to change program to P2...PO, there are ten

programs).

4. When the program has been changed, the density level will

return to "0". To raise the density, simply press the right

button again.

5. Touching the right or left button will activate the density

function and the LCD display the density level. After 10

seconds the LCD will display the number of minutes that the

unit is on for, the density and the mode every 3 seconds.

6. The unit works for a period of 30 minutes and then will

automatically turn off.

7. If the density level remains at 0 for more than 3 minutes,the

unit will automatically switch off.

8. The mode button will fast forward when pressed, the density

button will not.

5 STANDARD ACCESSORIES

The Electric Stimulator Kit have 3 different Contents:

1.) Electrode contains :a. Electrical Stimulator X 1b. Dual poles Self Adhering Pad X1d. Operating Manual X 1e. 3V(CR2025) Battery X 1g. Packing Plastic Case x 1

2.) Slim belt set contains :a. Electrical Stimulator X 1b. Conductive slim belt X 1c. Conductive gel X 1d. Elastic Strap L X 1e. Elastic Strap S X 1f. Operating Manual X 1g. 3V(CR2025) Battery X 1h. Packing Plastic Case X1

3.) Electrode & Slim belt set contains :a. Electrical Stimulator X 1b. Conductive slim belt X 1c. Conductive gel X 1d. Elastic Strap L X1e. Elastic StrapS X 1f. Dual poles Self Adhering Pad X 1g. Operating Manual X 1h.3V(CR2025) Battery X 1I. Packing Plastic Case X 1

6 TROUBLESHOOTING

ProblemNostimula-tionfelt

Intermittentstimulation

Notpowerfulenough

Surgesofpower

Possible Cause• Dead battery

• Battery in backwards

• Lead-off

• Broken lead wire

• Very dry electrode• Defective unit• Loose connection

unit or electrode• Broken lead wire

• Electrode too dryor worn out

• Battery running low• Electrodes resistance

too high• Improper mode

choice

• Electrode peelinglose from skin

Corrective Action• Replacewithfresh

battery• Remove and insert

correctly• Pullouttheunused

lead plug from unit• Replace cord set with

anothertocheckforbroken wire

• Re-apply electrodes• contact dealer• Reconnect, making

sure contact is secure• Replace cord set with

anothertocheckforbroken wire

• Re-apply electrodes

• Replace battery• Uselowimpedance

electrodes• Proper operation

function mode, pushfunction button foranother mode

• Replace electrode ifnecessary

6 TROUBLESHOOTING I-ProblemStimulationweaknessminutesafter start

Unwantedmuscletwitchesoccur

Stimulationstrong, butineffective

Possible Cause• Normal adaptation

process

•Amplitude too high

• Improper electrodeplacement

Corrective Action• Increase amplitude• Push function button

for another mode

• Decrease amplitude• Push function button

for another mode

• Reposition electrodes;consult your clinician

• Push function buttonfor another mode

If, after using this guide, the unit does not operate properly,theun it should be serviced. Please call yourdealer forinstruction.

Stepl step2 stepS

Dimensions : 5 3 x 3 0 x 1 Omm [HT329MKLD)54dia. x10mm (HT329M2(L2))54 x 35 x 10mm [HT329M3(L3)154x40 x 10mm [HT329M4(L4)J

Weight: Less than 30gm (battery included)Power Supply : 3V battery(CR2025) x 1 PieceChannels Isolation : One channel output by stud connectorOutput Current: 0-90mA peak to peak current into 500 ohm loadDensity : Change of 15 steps pulse amplitudeTimer: 30 minutes backward to auto offWave Form : Dual phase square waveLCD Screen : Exchange display; mode ; timer; densityProgram Mode : P1 ...P5 PMS program, each cycle SOsec., 7 cycles.

P6...PO PMS program, each cycle 1min.,7 cycles, contraction time (on time) 2 or 4 sec.relaxation time (off time) 2 or 4 sec.

^\step

mode\rat&\I

P2P3P4P5-̂""

P6P7P8P9PO

130sec.

25101530

1 min.

28

30366

2SOsec.

48152546

1 min.

515466446

3SOsec

25101586

1 min.

21010468

4SOsec.

610253025

1 min.

68

363664

5SOsec.

28101576

1 min.

410104610

6SOsec

45

253030

1 min.58

307878

7SOsec

68152564

1 min.

615106430

on time/

//

//

/

2/24/42/24/42/4

; All data is ± 10%

STIFF SHOULDER AND NECK. SORE SHOULDER

PARALYSIS OF BODY

61

WRIST NERVE, BACK PAIN, SCIATIC NERVE PAIN

CHRONIC RHEUMATISM; ROUGH SKIN; BLISTERED SKIN

8 REFERENCE APPLICATION

SKINNY;OBESITY

FACIAL NERVE PAIN ; INSOMNIA ; NEURASTHEN1ASLEEPLESS

MENSTRUATION PAIN ANDIRREGULAR MENSTRUATION

Another Clinical Uses:• a single area toner• muscle spasm reduction• tired muscle• nerve block ; reduction• cramp• postinjection scleroma• scar hypertrophy• stiff neck

• tennis elbow• arthritis• headache• insomnia• intercostal neuralgia• paraplegia• enuresis• beauty care etc.

•§-See your physician if you have any problems.

9) WARRANTY

SERVICE CARD

MODEL: TEL:

SERIAL NO : ADDRESS:

DATE PURCHASED: PURCHASED FROM :

OWNER'S NAME :

C€0434

Distributed by:

13 i