4 ht-329m3(l3 2 d 1 d -...
TRANSCRIPT
HT329M1~M4(L1~L4) LCD Screen Mini Wireless Digital PMS
INDEX
1. INTRODUCTION 1
2. CAUTION 2-3
3. INDICATOR AND CONTROLS 4-5
4. PREPARATION FOR USE 6
5. STANDARD ACCESSORIES 7
6. TROUBLESHOOTING 8-9
7. TECHNICAL SPECIFICATIONS 10
8. REFERENCE APPLICATION 11-12
9. WARRANTY 13
D HT329M1(L1) Q HT329M2(L2)D HT329M3(L3) D HT329M4(L4)
A Before using the instrument, please read!\e rat ing inst ruct ions care fu l ly !
INTRODUCTION
What is PMS? PMS stands for Powered Muscle Stimulator
The PMS unit is a battery powered device that transmits a
mild electric impulses through conductive self-adhesive electrodes.
These impulses pass through the skin to underlying nerve
fibers and muscles to modify the perception of pain.PMS is a safe and effective drug free method of reducing pain
that is in use by physicians and in pain clinics all over the world.
The Home Tech PMS system unit is a high quality electric
therapy stimulator that you can use in your home.
Pain therapy with PMS. The PMS provided may be
effective in helping to manage particular pain problems. Its
physiological reasonings are explained as follows:
a. Gate control theory.
b. The endorphin theory.
c. Nerve block theory.
d. Pumping effect.
e. Placebotheory.
No matter what pain theory is applied, PMS is both safe and
effective in pain management for many patients with pain.
• Re-use of the electrode by another user could cause the
cross-infection of skin disease.
• The device's shelf-life is 3 years.
• This device is warranted for a period of one year from the
date of purchase by the original buyer.
• The product complies with the electromagnetic compatibility
requirement of EN60601-1-2 as specified in EEC Directive
93/42/EEC as amended by 2007/47/EC.
• Operation in close proximity ( e.g. 1m ) to shortwave or
microwave therapy equipment may produce instability in
the stimulator output.(IEC601-2-10).
• Don'tapply the electrode pad to broken skin.
• Don't abruptly stop or reset the device. It may cause the
user discomfort.
• Don't re-use too many times, if the electrode has deteriorated.
The user may feel irritation, hotness or no effect.
• PMS should not be used in the presence of cardiac
pace make rsordur ing pregnancy.
CAUTION I-» Keep out of the reach of children.
• The contact period is within 30 min on the same part of
patient's body for each usage, but the contact period can
be adjusted by the physician or therapist.
' Don't stimulate over carotid sinus nerves or around the mouth
region.
1 Always use the specified accessories in the manual. The
use of other parts not approved by the manufacturer may
cause harm.
1 For service information like circuit diagram, parts list etc.,
please contact the distributers.
> To clean the unit apply with water or alcohol after treatment.
1 Clean and dry the area to which the electrodes are to be
applied with water or alcohol prior to application of the
electrode.
I-HT329M1(L1)
s
LCD Screen
On/Raise Switch
L Snap Connector
-Battery Housing
HT329M2(L2)
LCD Screen
L SnapConnector
- Battery Housing
3 INDICATORANDCONTROLS
HT329M3(L3)
-Snap Connector
Battery Housing
LCD Screen
On/Raise Switch
HT329M4(L4)
L Snap Connector
- Battery Housing
LCD Screen
On/Raise Switch
PREPARATION FOR USE
1. Insert 3V battery, making sure it is positioned correctly.
Connect to the pad and place on the skin area.
2. Touch the right button to turn on unit and raise density level
or touch the left button to lower the density level and turn off
the unit.
3. Turn on the unit. The LCD screen display will show P1 (touch
mode button to change program to P2...PO, there are ten
programs).
4. When the program has been changed, the density level will
return to "0". To raise the density, simply press the right
button again.
5. Touching the right or left button will activate the density
function and the LCD display the density level. After 10
seconds the LCD will display the number of minutes that the
unit is on for, the density and the mode every 3 seconds.
6. The unit works for a period of 30 minutes and then will
automatically turn off.
7. If the density level remains at 0 for more than 3 minutes,the
unit will automatically switch off.
8. The mode button will fast forward when pressed, the density
button will not.
5 STANDARD ACCESSORIES
The Electric Stimulator Kit have 3 different Contents:
1.) Electrode contains :a. Electrical Stimulator X 1b. Dual poles Self Adhering Pad X1d. Operating Manual X 1e. 3V(CR2025) Battery X 1g. Packing Plastic Case x 1
2.) Slim belt set contains :a. Electrical Stimulator X 1b. Conductive slim belt X 1c. Conductive gel X 1d. Elastic Strap L X 1e. Elastic Strap S X 1f. Operating Manual X 1g. 3V(CR2025) Battery X 1h. Packing Plastic Case X1
3.) Electrode & Slim belt set contains :a. Electrical Stimulator X 1b. Conductive slim belt X 1c. Conductive gel X 1d. Elastic Strap L X1e. Elastic StrapS X 1f. Dual poles Self Adhering Pad X 1g. Operating Manual X 1h.3V(CR2025) Battery X 1I. Packing Plastic Case X 1
6 TROUBLESHOOTING
ProblemNostimula-tionfelt
Intermittentstimulation
Notpowerfulenough
Surgesofpower
Possible Cause• Dead battery
• Battery in backwards
• Lead-off
• Broken lead wire
• Very dry electrode• Defective unit• Loose connection
unit or electrode• Broken lead wire
• Electrode too dryor worn out
• Battery running low• Electrodes resistance
too high• Improper mode
choice
• Electrode peelinglose from skin
Corrective Action• Replacewithfresh
battery• Remove and insert
correctly• Pullouttheunused
lead plug from unit• Replace cord set with
anothertocheckforbroken wire
• Re-apply electrodes• contact dealer• Reconnect, making
sure contact is secure• Replace cord set with
anothertocheckforbroken wire
• Re-apply electrodes
• Replace battery• Uselowimpedance
electrodes• Proper operation
function mode, pushfunction button foranother mode
• Replace electrode ifnecessary
6 TROUBLESHOOTING I-ProblemStimulationweaknessminutesafter start
Unwantedmuscletwitchesoccur
Stimulationstrong, butineffective
Possible Cause• Normal adaptation
process
•Amplitude too high
• Improper electrodeplacement
Corrective Action• Increase amplitude• Push function button
for another mode
• Decrease amplitude• Push function button
for another mode
• Reposition electrodes;consult your clinician
• Push function buttonfor another mode
If, after using this guide, the unit does not operate properly,theun it should be serviced. Please call yourdealer forinstruction.
Stepl step2 stepS
Dimensions : 5 3 x 3 0 x 1 Omm [HT329MKLD)54dia. x10mm (HT329M2(L2))54 x 35 x 10mm [HT329M3(L3)154x40 x 10mm [HT329M4(L4)J
Weight: Less than 30gm (battery included)Power Supply : 3V battery(CR2025) x 1 PieceChannels Isolation : One channel output by stud connectorOutput Current: 0-90mA peak to peak current into 500 ohm loadDensity : Change of 15 steps pulse amplitudeTimer: 30 minutes backward to auto offWave Form : Dual phase square waveLCD Screen : Exchange display; mode ; timer; densityProgram Mode : P1 ...P5 PMS program, each cycle SOsec., 7 cycles.
P6...PO PMS program, each cycle 1min.,7 cycles, contraction time (on time) 2 or 4 sec.relaxation time (off time) 2 or 4 sec.
^\step
mode\rat&\I
P2P3P4P5-̂""
P6P7P8P9PO
130sec.
25101530
1 min.
28
30366
2SOsec.
48152546
1 min.
515466446
3SOsec
25101586
1 min.
21010468
4SOsec.
610253025
1 min.
68
363664
5SOsec.
28101576
1 min.
410104610
6SOsec
45
253030
1 min.58
307878
7SOsec
68152564
1 min.
615106430
on time/
//
//
/
2/24/42/24/42/4
; All data is ± 10%
STIFF SHOULDER AND NECK. SORE SHOULDER
PARALYSIS OF BODY
61
WRIST NERVE, BACK PAIN, SCIATIC NERVE PAIN
CHRONIC RHEUMATISM; ROUGH SKIN; BLISTERED SKIN
8 REFERENCE APPLICATION
SKINNY;OBESITY
FACIAL NERVE PAIN ; INSOMNIA ; NEURASTHEN1ASLEEPLESS
MENSTRUATION PAIN ANDIRREGULAR MENSTRUATION
Another Clinical Uses:• a single area toner• muscle spasm reduction• tired muscle• nerve block ; reduction• cramp• postinjection scleroma• scar hypertrophy• stiff neck
• tennis elbow• arthritis• headache• insomnia• intercostal neuralgia• paraplegia• enuresis• beauty care etc.
•§-See your physician if you have any problems.
9) WARRANTY
SERVICE CARD
MODEL: TEL:
SERIAL NO : ADDRESS:
DATE PURCHASED: PURCHASED FROM :
OWNER'S NAME :
C€0434
Distributed by:
13 i