4024 ser ie s...aion led is not liable f or damages incurred by negligence, fault y wiring, poor...

2
Primary, task, accent, cabinet, cove, counter, sofmU CBr, display, curved elevation, edge-lit glass, handrail, path, signage, art, ropelight/ neoO nVPrescent replacement (36) SMD LED/ft Draw: 2.6 - 3 W/ft Voltage: 24 DC TYPE: PS Indoor only IP62 Easy installation with adhesive backing LxWxH: 16.3 ft x 0.39" x 0.10" 16.3 ft x 0.49" x 0.17" WR Wet location IP67 Cut, Connect, & Seal WR-MK Mounting kit included Requires silicone adhesive or WR-MT mounting tape sold separately 4024-X-PS 4024-X-WR *5 year warranty on Aion LED Linear Fixture parts only; against manufacturing defects. Must be purchased new, as a complete system, and installed per Aion LED guidelines by a licensed electrician. UL Approved Class 2 CEC TITLE 24 Listed 50,000 lamp hours Custom Fabrication Per Two Inches 5 Year Standard Warranty* (multiple pages) WR-MK Rigid ABS Mounting Clip 1.14 WR-MT Aion LED WR Type Mounting Tape A-CORD Aion LED Class 2 Power Cable BC-SERIES Heat-shrinkable Cable Splice © Copyright 2012 Aion LED All Rights Reserved Warning: Installation should only be attempted by qualified and authorized personnel. Licensed electricians and trained technicians must wire all components in strict compliance with local building codes. Installer assumes all liability for safety and hazard mitigation. Aion LED is not liable for damages incurred by negligence, faulty wiring, poor design, overloading, or other. Authorized Aion LED Installers are trained in installation methods, materials, and code-related protocol. www.AionLED.com AION LED, LLC 2325 3RD ST #330 SAN FRANCISCO, CA 94107 TOLL FREE: (877) 345-AION [2466] FAX: (415) 285-1335 [email protected] Class 2 24V High Output High Quality Components Interior/Exterior Residential/Commercial New Construction/Retrofit 4024 SERIES ELECTRICIAN INSTALLED Wall penetrations require electrical junction boxes per local code. Long cable runs & in-wall wiring require proper cord gage and type, per local code. To avoid voltage drop, multiple power feeds may be required. LED Linear Fixture max length = 30 ft (per circuit/ homerun lead from LED Driver). Per CLASS 2 requirements [NEC Article 725]. MAY REQUIRE LARGER GAGE CABLE TO EXTEND POWER FEEDS BEYOND 40 FEET. ACCESSORIES [NOT INCLUDED -SOLD SEPARATELY] COMPATIBLE WITH AION LED DRIVERS, A-TRACK MODULAR MOUNTING SYSTEM WITH DIFFUSER LENS & A-CORD IN-WALL APPROVED 18/2 POWER CABLE WR TYPE INCLUDES WR-MK MOUNTING KIT WITH STRAPS & SCREWS. SUPPLEMENT WITH AION LED WR-MT MOUNTING TAPE (INDOOR/ NON-POROUS) OR CLEAR SILICONE ADHESIVE CAULKING (OUTDOOR -OR- POROUS)

Upload: others

Post on 06-Oct-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 4024 SER IE S...Aion LED is not liable f or damages incurred by negligence, fault y wiring, poor design, overloading, or other. Authorized A ion LED Inst allers are t rained in inst

Primary, task, accent, cabinet, cove, counter, sofmU �CBr, display, curved elevation, edge-lit glass, handrail, path, signage, art, ropelight/ neoO��nVPrescent replacement

(36) SMD LED/ftDraw: 2.6 - 3 W/ftVoltage: 24 DC

TYPE: PS

Indoor only IP62Easy installation withadhesive backing

LxWxH: 16.3 ft x 0.39" x 0.10" 16.3 ft x 0.49" x 0.17"

WR

Wet location IP67 Cut, Connect, & SealWR-MK Mounting kit includedRequires silicone adhesive or WR-MT mounting tape sold separately

4024-X-PS

4024-X-WR

*5 year warranty on Aion LED Linear Fixture parts only; against manufacturing defects. Must be purchased new, as a complete system, and installed per Aion LED guidelines by a licensed electrician.

UL Approved Class 2CEC TITLE 24 Listed50,000 lamp hoursCustom Fabrication Per Two Inches5 Year Standard Warranty*

(multiple pages)

WR-MK

Rigid ABSMounting Clip

1.14

WR-MT

Aion LED WR TypeMounting Tape

A-CORD

Aion LED Class 2 Power Cable

BC-SERIES

Heat-shrinkableCable Splice

© Copyright 2012 Aion LED All Rights Reserved

Warning: Insta l la t ion should only be at tempted by qual i f ied and author ized personnel . L icensed e lect r ic ians and t ra ined technic ians must wire a l l components in s t r ic t compl iance wi th local bui ld ing codes. Insta l ler assumes al l l iab i l i ty for safety and hazard mi t igat ion. Aion LED is not l iab le for damages incurred by negl igence, faul ty wir ing, poor design, over loading, or other . Author ized Aion LED Insta l lers are t ra ined in insta l la t ion methods, mater ia ls , and code-re lated protocol .

www.AionLED.com

AION LED, LLC 2325 3RD ST #330 SAN FRANCISCO, CA 94107 TOLL FREE: (877) 345-AION [2466] FAX: (415) 285-1335 [email protected]

Class 2 24VHigh Output

High Quality ComponentsInterior/Exterior

Residential/CommercialNew Construction/Retrofit

4024 SERIES

ELECTRICIAN INSTALLED

Wall penetrations require electrical junction boxes per local code. Long cable runs & in-wall wiring require proper cord gage and type, per local code. To avoid voltage drop, multiple power feeds may be required. LED Linear Fixture max length = 30 ft (per circuit/ homerun lead from LED Driver).Per CLASS 2 requirements [NEC Article 725].

MAY REQUIRE LARGER GAGE CABLE TO EXTEND POWER FEEDS BEYOND 40 FEET.

ACCESSORIES [NOT INCLUDED -SOLD SEPARATELY]

COMPATIBLE WITH AION LED DRIVERS, A-TRACK MODULAR MOUNTING SYSTEM WITH DIFFUSER LENS & A-CORD IN-WALL APPROVED 18/2 POWER CABLE

WR TYPE INCLUDES WR-MK MOUNTING KIT WITH STRAPS & SCREWS. SUPPLEMENT WITH AION LED WR-MT MOUNTING TAPE (INDOOR/ NON-POROUS) OR CLEAR SILICONE ADHESIVE CAULKING (OUTDOOR -OR- POROUS)

Page 2: 4024 SER IE S...Aion LED is not liable f or damages incurred by negligence, fault y wiring, poor design, overloading, or other. Authorized A ion LED Inst allers are t rained in inst

PS TYPEIP62Indoor UseWhite4024-XW26-PS4024-XW27-PS4024-XW28-PS4024-WW32-PS4024-PW43-PS4024-PW60-PS

4024-22-PS

WR TYPEIP66Damp Location

4024-XW26-WR4024-XW27-WR4024-XW28-WR4024-WW32-WR4024-PW43-WR4024-PW60-WR

4024-22-WR

~CCT

2600K2700K2800K3200K4300K6000K

2200K

333333

2.6

223232261226248265

737684788587

Single Colors: Red, Green, Blue, Yellow

(IP62 Indoor Use)4024-R-PS4024-G-PS4024-B-PS4024-Y-PS4024-P-PS

(IP66 Damp Location)4024-R-WR4024-G-WR4024-B-WR4024-Y-WR4024-P-WR

FIRM

JOB

TYPE

MEMO

SKU

DESC

PACKAGING: 16.3 ft reel (sold per foot)

TEST #: L09111205CATALOG #: 4000-XW28-XXLUMINAIRE: 11-13/16"L. X 5/16"W. X 1/16"H. LED STRIP 12 MODULES, EACH MODULE

HAS 3 2800K LEDS WITH 63/64" SPACING TOTAL 36 LEDS WITH 11/32"SPACING

LAMP CAT #: 2800K LEDLAMP OUTPUT: 1 LAMP(S), RATED LUMENS/LAMP: 260.9005

TEST BASED ON ABSOLUTE PHOTOMETRY *INPUT WATTAGE: 3.0LUMINOUS OPENING:RECTANGLE (L: 11.59", W: 0.12") MAX CD: 92.0 AT HORIZONTAL: 0°, VERTICAL: 0°ROADWAY CLASS: TYPE VS

SERIES4024

COLOR TEMP (K)XW26 = 2600XW27 = 2700XW28 = 2800WW32 = 3200PW43 = 4300PW60 = 600022 = 2200

COATINGWR = IP66 OUTDOOR DAMP LOCATIONPS = IP62 INDOOR USE

0 2 4WHITE LINEAR FIXTURE SKU

CUSTOM FABRICATED PER TWO INCHESSPECIFY LINEAL DIMENSION ON FIXTURE SCHEDULECONFIRM ACTUAL LENGTHS WHEN ORDERING FIXTURE POWER FEEDS CAN BE EXTENED OR TRANSITIONED TO BUILDING WIRE WITHIN ELECTRICAL JUNCTION BOXES OR BY UTILIZING BC SERIES CONNECTORS

(Continued)

4024 SERIES

4

2"

(30 ft)

0.39" PS (0.49" WR)

0.10" PS (0.17" WR)2 INCHES

*5 year warranty on Aion LED Linear Fixture parts only; against manufacturing defects. Must be purchased new, as a complete system, and installed per Aion LED guidelines by a licensed electrician.

© Copyright 2012 Aion LED All Rights Reserved

Warning: Insta l la t ion should only be at tempted by qual i f ied and author ized personnel . L icensed e lect r ic ians and t ra ined technic ians must wire a l l components in s t r ic t compl iance wi th local bui ld ing codes. Insta l ler assumes al l l iab i l i ty for safety and hazard mi t igat ion. Aion LED is not l iab le for damages incurred by negl igence, faul ty wir ing, poor design, over loading, or other . Author ized Aion LED Insta l lers are t ra ined in insta l la t ion methods, mater ia ls , and code-re lated protocol .

www.AionLED.com

AION LED, LLC 2325 3RD ST #330 SAN FRANCISCO, CA 94107 TOLL FREE: (877) 345-AION [2466] FAX: (415) 285-1335 [email protected]

New! Candle Light 2100-2200K 90+ CRI

(Candle Light color LM Data Pending, 90+CRI, exceeds CEC Title 24 requirements for high efficacy)

W/ft Lm/ft Eff icacy