42ou ocp rack venus - managment software armor · up to 144 x cpu in 42u rack 18 ou node 18 x 48 =...
TRANSCRIPT
157157
42OU OCP Rack Venus - Managment Software
ARMORAIC Remote Management on Rack
FeaturesFacilitate managing large scale hardware deployment • Hardware inventory management Hardware scan Hardware configuration import • BMC IP management Auto static IP assignment IP-Location binding IP-Mac address binding • Group Management Execute tasks against entire rack Execute tasks against multiple racks Execute tasks against user defined groups
Manage hardware remotely with limited impact to service • Remote management Out-of-band managemnt Agentless management iKVM and Virtual Media Redirection Remote server power on/off • User management Local user management User roles definition with granular permissions User action logs • Data center floor plan Customize your own data center layout Location aware alerting
Monitor Hardware Status • Power consumption status • Temperature status
Automate Management Tasks • Auto email alerts • Scheduled or delayed task execution
System Requirements• Intel® Xeon® CPU• 4GB RAM• 1GbE port• 10GB disk space• Fedora 25 Operating System• Latest Java Runtime Environment
This is a customizable requirement. More hardware components details could be listed if needed. Auto-send notification to you once some devices could NOT be detected.
Using Rack Simulation with sensor to replace raw data for monitoring, people could easily know the multi-rack sensor data value change through the dots color on this page. To understand the rack relative location through the floor plan that includes the datacenter layout.
Touching the rack short name on Racks Simulation, people can quickly understand the rack absolute location through the floor plan that includes the datacenter layout and review which tasks had executed in this rack.
158158Global HQ: [email protected] • USA HQ: [email protected] www.aicipc.com
Remark: All specifications and photos are subject to change without notice. © 2020 AIC Inc. All rights reserved.
AR
MO
R
Major Functions• Facilitate managing large scale hardware deployment• Manage hardware remotely with limited impact to service• Monitor hardware status• Automate managing
OverviewRack Venus: OCP compliant rack design that integrates power banks and fans. • High power efficiency • High thermal efficiency • Rack Management Controller (RMC) • Centralized management and monitoring
ARMOR: Management software designed with multi-rack management in mind. • Simplify data center operation • Simplify firmware management • Simplify hardware maintenance
Nodes Pool & Management for single rack: The first part of out-band remote management. Only users with permission could execute these remote control functions. Each user behavior will be recorded.
Group Members & Management: The second part of out-band remote management. Users execute remote management function for the nodes from different racks at the same time by one button. The operation process is as simple as nodes pool, only the background color is different.
600mm
2230.5 mm
Depth 1185mm(with front door)
Up to 144 x CPU in 42U Rack
18 OU Node 18 x 48 = 864mm
Middle 6 OU +0.5 OU Crossbar
1 OU Switch Zone1 OU Switch Zone1 OU Power Shelf1 OU Power Shelf1 OU Switch Zone1 OU RMC Mgmt Module
18 OU Node 18 x 48 = 864mm
Front View