Thank you for choosing another quality product from Amperes Electronics. INSTRUCTION MANUAL LS4600 Speaker Line Surveillance VER 3 / 2015 LS4600 was produced out of extensive research and development effort in which every aspect of line surveillance require- ments are studied. It solves the problem faced by many installers using the conventional line monitoring method, by adopt- ing impedance measurement methodology. This shall eliminate the needs to add coupling capacitors to every speakers, rigid cabling rules as well as inaccuracy in detection. Thereby, LS4600 allows branching in cabling works, direct tapping of line to speakers as well as easier setup, without having to trim impedance against a preset reference. LS4600 is built and run by a micro-controller , thus providing a digital platform in setting up your system. User can set various parameters by following the menu displayed in the LCD screen. Among them shall be the high and low limits, buzzer on / off, display backlight, monitoring setup time, auto or manual mode as well as doing manual testing. It shall not be difficult to understand or to install the unit, but it is recommended that a trained personnel is engaged in order to tap the many features available. Before installation, we suggest a thorough read through of the manual is done to avoid any unnecessary damage to your setup. Please keep this manual handy for any future references.

Upload: others

Post on 17-Sep-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INSTRUCTION MANUAL · 12. OUTPUT FAULT CONTACT ... Speakers Parallel ZONE 6 RACK MOUNT ZONE VOL.CTRL. SPEAKER ZONE SELECTOR POWER AMPLIFIERS LS4600 24V DC VOLTAGE AUDIO SIGNAL INPUTS

Thank you for choosing another quality product from Amperes Electronics.

INSTRUCTION MANUAL

LS4600Speaker Line Surveillance

VER 3 / 2015

LS4600 was produced out of extensive research and development effort in which every aspect of line surveillance require-ments are studied. It solves the problem faced by many installers using the conventional line monitoring method, by adopt-ing impedance measurement methodology. This shall eliminate the needs to add coupling capacitors to every speakers, rigid cabling rules as well as inaccuracy in detection. Thereby, LS4600 allows branching in cabling works, direct tapping of line to speakers as well as easier setup, without having to trim impedance against a preset reference.

LS4600 is built and run by a micro-controller , thus providing a digital platform in setting up your system. User can set various parameters by following the menu displayed in the LCD screen. Among them shall be the high and low limits, buzzer on / off, display backlight, monitoring setup time, auto or manual mode as well as doing manual testing.

It shall not be difficult to understand or to install the unit, but it is recommended that a trained personnel is engaged in order to tap the many features available. Before installation, we suggest a thorough read through of the manual is done to avoid any unnecessary damage to your setup.

Please keep this manual handy for any future references.

Page 2: INSTRUCTION MANUAL · 12. OUTPUT FAULT CONTACT ... Speakers Parallel ZONE 6 RACK MOUNT ZONE VOL.CTRL. SPEAKER ZONE SELECTOR POWER AMPLIFIERS LS4600 24V DC VOLTAGE AUDIO SIGNAL INPUTS

Parts Identifications

PAGE 2 LS4600 | 6 CHANNEL SPEAKER LINE SURVEILLANCE

1 6

8

72 3 4 5

9 10 11 12 13

Front view

Rear view

1. LCD DISPLAY

2. MENU BUTTON

3. ENTER BUTTON

Previous key to scroll back to last menu or sub menu.

4. PREV BUTTON

Next key to scroll forward of menus.

5. NEXT BUTTON

6. GREEN NORMAL LEDs

7. RED FAULT LEDs

2 x 16 digit LCD display with back light setting is used as programming guide as well as measurement indications. The back light can be set to off if required by accessing menu 6 (see programming chart). The back light is set to ON in default.

Menu switch is used to access main menus. Once pressed momentarily, it shall revert to Menu 1.0 - Setup. Use Next and Prev keys to scroll through other main menus. Once the relevant menu is found, use Enter key to access its following sub menu. To exit sub menus, press Menu key momentararily.

Used to enter required main menu or its sub menus, confirm values, data or settings.

The arrays of green LEDs provides the status of the channel which show the normal condition if lit. If both green and red LEDs do not lit for the particular channel, it means that the channel has been bypassed from monitoring.

Once lit, it indicates that the particular channel is at fault ; either open, short or leakage. Refer to the LCD panel for exact condition of fault.

Page 3: INSTRUCTION MANUAL · 12. OUTPUT FAULT CONTACT ... Speakers Parallel ZONE 6 RACK MOUNT ZONE VOL.CTRL. SPEAKER ZONE SELECTOR POWER AMPLIFIERS LS4600 24V DC VOLTAGE AUDIO SIGNAL INPUTS

Parts Identifications

PAGE 3LS4600 | 6 CHANNEL SPEAKER LINE SURVEILLANCE

The unit requires 24V DC power supply and recommended PSU shall be Amperes PS9400. Only use regulated power supply if other than PS9400 is installed.

9. 24V DC POWER SUPPLY PORT

If fault is detected, a buzzing sound shall be emitted with the LED lit. Buzzer alert can be turned off via programming and this is indicated by this LED.

8. BUZZER LED

When line monitoring is initiated either manually or auto, it shall start in sequence from ch.1 to 6. With each channel under monitoring, a dry contact shall be available at its correspondence zone. This shall provide 24V overriding voltage to volume controllers or local patch panel with overriding relay, thus allowing direct measurement to the speakers. (Refer to Connecting the unit section of the manual). Overriding is required for accurate sensing in which volume controllers set in various position shall have different impedances and such circumstances shall provide false alarm or alert.

Recommended practice is that every zone shall have its own 24V overriding circuit back to the rack. If all the overriding circuits are looped, and if the particular zone with volume controller is set to off, the monitoring activity shall cause a burst of audio signal (such as BGM), which lasted for approximately 18 seconds. This shall happen only when a BGM source is presence. If the particular zone is set to OFF (without BGM), the monitoring activity shall not emit audible sound.

10. ZONE TRIGGER OUTPUT PORT

It is for connections of incoming 100V line signal and output to speakers. Refer to Connecting the Unit in following section.

11. AMP / ZONE IN - OUT PORTS

Whenever a fault condition is detected, this port shall provide a dry contact to link to external alerting devices, such as mimic panel, etc.

12. OUTPUT FAULT CONTACT

Event triggered data shall be transmitted with RS485 protocol. This feature is optional and shall be available in future.

13. RS485 OUTPUT (OPTIONAL)

Page 4: INSTRUCTION MANUAL · 12. OUTPUT FAULT CONTACT ... Speakers Parallel ZONE 6 RACK MOUNT ZONE VOL.CTRL. SPEAKER ZONE SELECTOR POWER AMPLIFIERS LS4600 24V DC VOLTAGE AUDIO SIGNAL INPUTS

Configuration / Schematic

PAGE 4 LS4600 | 6 CHANNEL SPEAKER LINE SURVEILLANCE

Zone 1Speakers Parallel

ZONE 6

RACK MOUNTZONE

VOL.CTRL.

SPEAKER ZONE

SELECTOR

POWER AMPLIFIERS

LS4600

24V DC VOLTAGE

AUDIO SIGNALINPUTS NOT

SHOWN

VOLUME CONTROLLERS /

PATCH PANEL

AUDIO SIGNAL

24V DC OVERRIDING

The LS4600 detects circuit faults using impedance measurement method. In general, there is no limitation on how the external cabling to speakers or volume controller are run, ie. branching is allow and does not need end line resistors as well as speaker capacitor couplings.

LS4600 have been improve all accuracy. It is recommended that periodical manual checking or setup to be made as connections may deteriorate over time and thus affecting overall impedance value.

Only 4 wire system is suitable for measurement. 3 wire system may cause undesirable result each time checking is being made due to the presence of volume controllers.

PUBLIC ADDRESS POWER AMPLIFIER

SIGNAL -40 dB

SIGNAL -10 dB

POWER

PROTECT

CLIP

PA 2480 amperes

PUBLIC ADDRESS POWER AMPLIFIER

SIGNAL -40 dB

SIGNAL -10 dB

POWER

PROTECT

CLIP

PA 2480 amperes

ZS5121

OVERRIDE 21 3 54SPEAKER ZONE SELECT6 7 8 9 10 1211

CALLALL

Zone 2Direct VC

Zone 3VC Parallel

Zone 6

Page 5: INSTRUCTION MANUAL · 12. OUTPUT FAULT CONTACT ... Speakers Parallel ZONE 6 RACK MOUNT ZONE VOL.CTRL. SPEAKER ZONE SELECTOR POWER AMPLIFIERS LS4600 24V DC VOLTAGE AUDIO SIGNAL INPUTS

PAGE 5LS4600 | 6 CHANNEL SPEAKER LINE SURVEILLANCE

Connecting The Unit

24V DC OVERRIDING CONTROL (EP1200A ETC)

+24V

RS 485 OUTPUT(OPTIONAL)

VOLUME CONTROLLERS WITH OVERRIDING RELAY

+24V-VE

TO SPEAKERSTO SPEAKERS

FROM ZONE SELECTOR100V LINE OUTPUT

FROM ZONE SELECTOR100V LINE OUTPUT

24V DC POWER

repeat

Loop the 24V DC overriding trigger to the Zone Trig. O/P port

Max rating per zone trigger is 3A. Use external relay if required

+VE-VE -VE

+VE repeat

add diode

TO MIMIC PANEL / EXTERNAL FAULT INDICATOR ETC ( A DRY CONTACT OUT)

It is recommended that separate zone shall have separate overriding circuit. Otherwise, loop all outputs. Disadvantage of looping all outputs : If a particular zone is active (zone on) but the volume controller at a certain area is shut off (eg. zone 1), activation of monitor-ing from LS4600 of zone 2 shall override the volume controllers at zone 1, thus a burst of audio shall be heard ( such as BGM being currently played).

Programming And Setup

MAIN MENU

1.0 SETUPo<>

2.0 MANUAL TESTo<>

3.0 MEM. RECALLo<>

4.0 AUTO TESTo<>

5.0 BUZZERo<>

6.0 LCD LIGHTo<>

7.0 MEMORYo<>

The last part of the unit installation shall be programming as well as entering required values. Program the unit by following the menus shown in the LCD display panel. Each of the menu and sub menus shall be explained in the following sections.

In general, there are 7 main menus as shown below :

Initializing... LS4600 VER: X.XX

AMPERES ELEC. S/B LINE SUPERVISORY>>

POWER UP

TO ENTER SETUP

1.0 SETUPo<>

NOTE :

>>

< denotes PRE > denotes NEXT and[] as ENTER

Upon powering for the first time, the unit shall display introduction wordings in running mode. The green and red LEDs shall lit in sequence indicating sequence of initialisation.

Minumum setup required for the system to run shall be Menu 1.0 and 4.0. If other menus are not set, they shall run according to default parameters.

To begin programming, press, hold and release MENU button, and the SETUP menu shall be displayed.

Page 6: INSTRUCTION MANUAL · 12. OUTPUT FAULT CONTACT ... Speakers Parallel ZONE 6 RACK MOUNT ZONE VOL.CTRL. SPEAKER ZONE SELECTOR POWER AMPLIFIERS LS4600 24V DC VOLTAGE AUDIO SIGNAL INPUTS

PAGE 6 LS4600 | 6 CHANNEL SPEAKER LINE SURVEILLANCE

1.0 Setup Menu

Press ENTER and PRE or NEXT key for setting up remaining channels or MENU to return to previous menu. BP = Bypass

1.1 CH.No.#Accept?/Bypass?

1.1 CH.No.# Bypass ?

1.1 CH.No.# Accept ?

1.1 CH.No.# Bypass OK

1.1 CH.No.# *o<> Imp xxxx

1.1 CH.No.# Accept OK

1.2 BP ON FAULTo<> <ON> CH.#

1.2 BP ON FAULTo<> <OFF> CH.#

ENTER>>

ENTER>>

NEXT>

NEXT>

PRE>PRE>* Default <ON>

>

ENTER

>

>Channel bypass mark *

BASIC SETUP

Use PRE or NEXT keys to select the required channel. Imp value shall be shown, otherwise OPEN or SHORT shall appear. Press ENTER to proceed to the next setting for the selected channel. A channel with or without value can be bypassed from surveillance or accepted for monitoring. Select PRE to accept for monitoring or NEXT to bypass.

In BASIC Mode Hi and Lo function will be disabled, only OPEN and SHORT monitoring available.

To enable Hi and Lo function use ADVANCE setup in menu 1.0 (SETUP)

The ' * ' symbol will show when the value measured is out of preset range of Hi and Lo limits.

Short or Open condition is self explainatory.A fault condition shall have red LED lit and vice versa.

NEXT to Menu 2.0>1.0 SETUPo<> PRE to Menu 7.0

>

ENTER>

1.0 BASIC SETUPo<>

ENTER>1.1 CH.No.#o<> Imp xxxx

ENTER>

Use < or > to toggle between Basic and Advance Setup

Press < or > to switch channel number.

Press < or > to accept the value of status.

MENUBack to Menu 1.0

>

There are 2 modes of operation available : Basic and Advance.

In Basic setup mode, LS4600 shall detect the circuit for Open and Short only. The timing of detection shall depend on the intervals set in Auto Detection mode, ( Refer to Auto Test section ). Follow the steps below to use this mode.

Page 7: INSTRUCTION MANUAL · 12. OUTPUT FAULT CONTACT ... Speakers Parallel ZONE 6 RACK MOUNT ZONE VOL.CTRL. SPEAKER ZONE SELECTOR POWER AMPLIFIERS LS4600 24V DC VOLTAGE AUDIO SIGNAL INPUTS

PAGE 7LS4600 | 6 CHANNEL SPEAKER LINE SURVEILLANCE

1.0 Setup Menu

ENTER>

ADVANCE SETUP

Use PRE or NEXT keys to select the required channel. Imp value shall be shown, otherwise OPEN or SHORT shall appear. Press ENTER to proceed to the next setting for the selected channel.

A channel with or without value can be bypassed from surveillance or accepted for monitoring. Select PRE to accept for monitoring or NEXT to bypass.

The preselected values for high limit and low limits are from 00 ohm to 500 ohm, with incremental of 20 Ohms. We recommend 50 % higher or lower values to avoid unnecessary false triggering.Once the required value is selected, press ENTER to proceed to the next sub menu.

1.0 SETUPo<>

1.0 SETUPo<> ADVAN SETUP

ENTER>

1.1 CH.No.#o<> Imp xxxx

ENTER>

1.1 CH.No.#Accept? / Bypass

1.1 CH.No.# Accept OK

ENTER>

Accept

1.2 BP ON FAULTo<> <ON> CH.#

ENTER>

1.3 H-LIMIT +##o<> Imp xxxx

1.4 L-LIMIT -##o<> Imp xxxx

ENTER>

ENTER>

1.5 EXIT ?o<> Y?/N?

To select Bypass or On upon fault detection

Bypass1.1 CH.No.# Bypass OK

1.1 CH.No.# *o<> Imp xxxx

>

Channel bypass mark *

>

On selected set High-limit

On selected set Low-limit

Page 8: INSTRUCTION MANUAL · 12. OUTPUT FAULT CONTACT ... Speakers Parallel ZONE 6 RACK MOUNT ZONE VOL.CTRL. SPEAKER ZONE SELECTOR POWER AMPLIFIERS LS4600 24V DC VOLTAGE AUDIO SIGNAL INPUTS

PAGE 8 LS4600 | 6 CHANNEL SPEAKER LINE SURVEILLANCE

2.0 Manual Test

3.0 MEM RECALLO<>

3.1 CH#=xxxxH=xxxx L=xxxx

>

ENTER

>

# Use PRE or NEXT keysto select channel number

> Press NEXT to Menu 4.0PRE to Menu 2.0

>

MENU

ENTER

3.0 Mem. Recall

Use this function to test speaker line impedance of each channel. Please note that the value shown are approximated figure. To obtain the actual value, use a dedicated Impedance Measurement meter.

This menu enable the user to view the values of impedance of selected channels, which had been accepted earlier during setup (Menu 1.0).

To clear the memories, use the MEMORY Menu (Menu 7.0) and all previously stored values and settings shall be erased.

2.0 MANUAL TESTo<>

PRE to Menu 1.0

>

> Press NEXT to Menu 3.0

> ENTER

2.1 +Hi>xxxxCH# Imp XXXX

2.2 EXITO<>

>

ENTER

>To Sub Menu 2.0

>

>To Sub Menu 2.0YES

NO

To Sub Menu 2.1

< or > to select Ch number and check impedance

< or > to select Yes or No

Page 9: INSTRUCTION MANUAL · 12. OUTPUT FAULT CONTACT ... Speakers Parallel ZONE 6 RACK MOUNT ZONE VOL.CTRL. SPEAKER ZONE SELECTOR POWER AMPLIFIERS LS4600 24V DC VOLTAGE AUDIO SIGNAL INPUTS

PAGE 9LS4600 | 6 CHANNEL SPEAKER LINE SURVEILLANCE

4.0 Auto Test

4.0 AUTO TESTO<>

4.1 SELECT TIMERO<> Test Seq=off

> ENTER

# Use < or > to select Auto or Manual mode

> Press NEXT to Menu 5.0PRE to Menu 3.0

>

4.2 AT.TEST ON?O<> Y?/N?

>

ENTER

LS4600 VX.XX[SPEAKER LINE SURVEILLANCE]<<Auto Test xxh:xxm:xxs<<-Remaining..<xxx

>

This menu must be accessed for first time programming, in which shall determine how the unit shall run, either manually or automatically.

If SELECT TIMER mode is selected, testing interval time should be entered, otherwise, the default timer is set to off.

Once timer has been entered and auto mode selected, the unit shall immediately start testing sequence and the counter began from then onwards.

To access to the main menu again, press Menu key

>

Return to Submenu 4.0

If Off is selectedIf a test interval is selected (from 1 min to 24 hours). By default, auto mode is set to off. Use < or > key to select time.

ENTER>

>

If NO is selected

Return to Submenu 4.0

Press < or > to select ON or OFF for Auto Test.

If Auto Test is ON

Menu

The test sequence is started and repeated at the preset interval. Remainning time for the next sequence is displayed.

5.0 Buzzer

5.0 BUZZERo<>

5.1 KEY BEEP

ENTER> Press NEXT to Menu 6.0PRE to Menu 4.0

>

5.2 FAULT BUZZER

>

Buzzer is available for button pressing and alert / fault signal. This feature can be turned off to fit to ones' preference.

For fault alert buzzer, if this is switch on, the Buzzer LED shall not lit when a failure is detected. If the buzzer is switched off, the buzzer LED and the correspondence channel fault LED shall lit.

>

ENTER

>

Press < or > to select ON / OFF whenever fault is detected.

Return to Buzzer Menu

Press < or > to select ON / OFF for key select.

Page 10: INSTRUCTION MANUAL · 12. OUTPUT FAULT CONTACT ... Speakers Parallel ZONE 6 RACK MOUNT ZONE VOL.CTRL. SPEAKER ZONE SELECTOR POWER AMPLIFIERS LS4600 24V DC VOLTAGE AUDIO SIGNAL INPUTS

PAGE 10 LS4600 | 6 CHANNEL SPEAKER LINE SURVEILLANCE

6.0 LCD Back Light

6.0 LCD LIGHT

> ENTER

This menu provides the option to turn ON or OFF the LCD back light.

6.0 LCD BACK LIGHT > Press NEXT to Menu 7.0PRE to Menu 5.0

>

Press < or > to switch ON or OFF Back Light for LCD display.

> ENTER

Return to LCD Back Light Menu

7.0 Memory

7.0 MEMORYo<>

7.0 MEMORYO<> RESET?

> ENTER

> Press NEXT to Menu 1.0PRE to Menu 6.0

>7.1 MEMORY SAVEO<> Y?/N?

>

7.0 MEMORYO<> SAVE?

If earlier settings are to be wiped off, use this memory reset and the system shall return to default.

After completing all channel setting, the changed parameters MUST be saved.

DC power to the unit can be switched off when system is not in use. Settings shall be retained in the memory.

>

Save > <

>>

< or > to reset or save the memory and press Enter

< or > to select

ENTER

Select < or > to save / No

Return to Memory Menu

Page 11: INSTRUCTION MANUAL · 12. OUTPUT FAULT CONTACT ... Speakers Parallel ZONE 6 RACK MOUNT ZONE VOL.CTRL. SPEAKER ZONE SELECTOR POWER AMPLIFIERS LS4600 24V DC VOLTAGE AUDIO SIGNAL INPUTS

Technical Specifications

PAGE 11LS4600 | 6 CHANNEL SPEAKER LINE SURVEILLANCE

Summary Of Features

6 channel speaker line monitoring and expandable

Basic and Advance level of detection setup

Detection of faulty cable and speaker in individual zone or circuit

Impedance measurement method - no capacitor coupling required and cable branching allowed.

Faulty circuit disconnection option

Built in impedance meter, range within 10 Ohm to 10 K Ohm

LCD display to facilitate system setup, measurement and monitoring

Fault alert with LED indicators and switchable buzzer

Detection test interval setting from 1 min to 48 hours

Short burst test signal, minimizing interruption to PA operation

User setting for detection sensitivity for open, short and leakage

Aux 24V DC output for volume controller overriding during testing mode

■■■■■■■■■■■■

Operating voltage 24V DC via PS9400 PSUPower consumption 3.5WCapacity 6 channel and expandableProcessor PIC micro controller with 12 bit ADCImpedance detection range 10 to 10 K OhmPower measurement range 3 to 1000W 100V lineMeasurement accuracy +/- 3% within rangePilot tone injection frequency 1 KHzPilot tone signal output level 5V sineTransmittal detection period 3 seconds per channelDetection interval User preset from 1 min to 48 hrsSensitivity setting User preset at each channelIndicators - LED Normal, Fault, Buzzer, Auto runDisplay LCD 2 x 16 characters w back lightAudible output signal Continuous buzzer with Off optionDry contact setting 3ADC output in detection mode 24V DC for individual channelDimensions (WxHxD) 482 x 44 x 180 mmWeight 2.3 kg

Note:The above specifications are correct at time of printing but subjected to changes without prior notice due to product improvements.

Page 12: INSTRUCTION MANUAL · 12. OUTPUT FAULT CONTACT ... Speakers Parallel ZONE 6 RACK MOUNT ZONE VOL.CTRL. SPEAKER ZONE SELECTOR POWER AMPLIFIERS LS4600 24V DC VOLTAGE AUDIO SIGNAL INPUTS

Warranty Conditions

Disclaimer

AMPERES ELECTRONICS SDN BHDMADE IN MALAYSIAPublished : March 2015

ISO 9001: 2008Design & Manufacture of Public Address Equipment and Systems

Certi�cate No. 16895 / A / 0001 / UK / En

Only Amperes Electronics Service Centres are allowed to make warranty repairs : a list of Amperes Electronics Service Centres may be asked for by the purchaser or send directly to Amperes Electronics Sdn Bhd at 70 Jalan Industri PBP 3, Tmn Perindustrian Pusat Bandar Puchong, 47100, Puchong, Selangor, Malaysia or its authorized master distributor, TNT Links Sdn Bhd / MyPA Systems Sdn Bhd. This warranty is not valid if repairs are performed by unauthorized personnel or service centres.

This warranty covers only repairs and replacement of defective parts ; cost and risks of transportation as well as removal and installation of the product from the main system are for the account of the purchaser. This warranty shall not extend to the replacement of the unit.

This warranty does not cover damages caused by misuse, neglect, accident of the product as well as using the product with power supply voltage other than shown on the product, or any other power supply source / adaptor not recommended by the manufacturer.

This warranty does not cover damages caused by fire, earthquakes, floods, lightning and every cause not directly related to the unit.

This warranty does not include any indemnity in favor of the purchaser or the dealer for the period out of use of the unit; moreover the warranty does not cover any damages which may be caused to people and things when using the product.

This warranty certificate is valid only for the described product, and is not valid if modifications are made on this certificate or on the identification label applied on the product.

This warranty covers all the material and manufacturing defects and is valid for a period of 12 months from the date of purchase or for a longer period in countries where this is stated by a national law. In this case, the extension is valid only in the country where the product is purchased.

Amperes Electronics Sdn Bhd is not obliged to modify previously manufactured products under warranty if the design changes or improvements are made.

Information contained in this manual is subject to change without prior notice and does not represent a commitment on the part of the vendor. AMPERES ELECTRONICS SDN BHD shall not be liable for any loss or damages whatsoever arising from the use of information or any error contained in this manual.

It is recommended that all services and repairs on this product be carried out by AMPERES ELECTRONICS SDN BHD or its authorized service agents.

AMPERES series must only be used for the purpose they were intended by the manufacturer and in conjunction with this operating manual.

AMPERES ELECTRONICS SDN BHD cannot accept any liability whatsoever for any loss or damages caused by service, maintenance or repair by unauthorized personnel, or by use other than that intended by the manufacturer.