45996 en-np24-12r-01 (page 1) - battery universe · 2012. 10. 25. · publication no:...

2
Publication No: EN-NP24-12R-01 • January 2005 Dimensions Specifications NOMINAL VOLTAGE: 12V NOMINAL CAPACITY: 20 hr. rate of 1.25A to 10.5V 25.0Ah 10 hr. rate of 2.25A to 10.5V 22.5Ah 5 hr. rate of 4.0A to 10.2V 20.0Ah 1 hr. rate of 15.0A to 9.60V 15.0Ah WEIGHT (approx.): 19 pounds (8.8 Kg) ENERGY DENSITY (20 hr. rate): 1.35 WH/cubic inch (79 WH/liter) SPECIFIC ENERGY (20 hr. rate): 15.8 WH/pound (35 WH/Kg) INTERNAL RESISTANCE OF CHARGED BATTERY: 10 milliohms (approx.) MAXIMUM DISCHARGE CURRENT WITH STANDARD TERMINALS: 150 amperes MAXIMUM SHORT-DURATION DISCHARGE CURRENT: 500 amperes OPERATING TEMPERATURE RANGE: CHARGE 5 0 F to 122 0 F (-15 0 C to 50 0 C) DISCHARGE -4 0 F to 140 0 F (-20 0 C to 60 0 C) CHARGE RETENTION (shelf life) at 68˚F (20˚C): 1 month 97% 3 months 91% 6 months 85% LIFE EXPECTANCY: STANDBY USE 3 to 5 years CYCLE USE (approx.): 100% depth of discharge 250 cycles 50% depth of discharge 550 cycles 30% depth of discharge 1200 cycles SEALED CONSTRUCTION: Can be operated in any position without leakage. STANDARD TERMINAL: Receptacle M5 HOUSING MATERIAL: ABS Resin OPTIONAL: Container and cover made from Flame Retardant ABS (UL94-V0/L.O.I.>28%) HARDWARE: 2-M5-.8 x 12mm Bolt w/ lock washer & flat washer NP NP24-12R NP24-12RFR Sealed Rechargeable Lead-Acid Battery 12V, 24Ah DIMENSIONS: MM (INCHES) Terminal DIMENSIONS: MM (INCHES) Φ12.0(0.47) M5 UL listing pending - File No MH16464

Upload: others

Post on 28-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • Publication No: EN-NP24-12R-01 • January 2005

    Dimensions

    Spec i f icat ions

    • NOMINAL VOLTAGE: 12V

    • NOMINAL CAPACITY:20 hr. rate of 1.25A to 10.5V 25.0Ah10 hr. rate of 2.25A to 10.5V 22.5Ah

    5 hr. rate of 4.0A to 10.2V 20.0Ah1 hr. rate of 15.0A to 9.60V 15.0Ah

    • WEIGHT (approx.): 19 pounds (8.8 Kg)

    • ENERGY DENSITY (20 hr. rate):1.35 WH/cubic inch (79 WH/liter)

    • SPECIFIC ENERGY (20 hr. rate):15.8 WH/pound (35 WH/Kg)

    • INTERNAL RESISTANCE OF CHARGED BATTERY: 10 milliohms (approx.)

    • MAXIMUM DISCHARGE CURRENT WITH STANDARD TERMINALS: 150 amperes

    • MAXIMUM SHORT-DURATIONDISCHARGE CURRENT:500 amperes

    • OPERATING TEMPERATURE RANGE: CHARGE 50F to 1220F

    (-150C to 500C)DISCHARGE -40F to 1400F

    (-200C to 600C)

    • CHARGE RETENTION (shelf life) at 68˚F (20˚C):1 month 97%3 months 91%6 months 85%

    • LIFE EXPECTANCY:STANDBY USE 3 to 5 yearsCYCLE USE (approx.):100% depth of discharge 250 cycles 50% depth of discharge 550 cycles30% depth of discharge 1200 cycles

    • SEALED CONSTRUCTION: Can be operated in any position without leakage.

    • STANDARD TERMINAL:Receptacle M5

    • HOUSING MATERIAL: ABS Resin

    • OPTIONAL:Container and cover made from Flame Retardant ABS (UL94-V0/L.O.I.>28%)

    • HARDWARE:2-M5-.8 x 12mm Bolt w/lock washer & flat washer

    NPNP24-12R

    NP24-12RFRSealed Rechargeable

    Lead-Acid Battery

    12V, 24Ah

    DIMENSIONS: MM (INCHES)

    Terminal

    DIMENSIONS: MM (INCHES)

    Φ12.0(0.47)

    M5

    UL listing pending - File No MH16464

  • Represented by:

    CHARGING METHODS (At 20ºC) Cycle use: Maximum charging current 0.25CCharging voltage 14.4 to 15.0V

    Standby use: Float charging voltage 13.50 to 13.80VCAUTION •Avoid short circuit

    •Do not charge in a sealed container.

    When the battery will be used by current in excess of 3C, consult with EnerSys prior to use.

    SELF DISCHARGE CHARACTERISTICS OPEN CIRCUIT VOLTAGEVS REMAINING CAPACITY

    CYCLE SERVICE LIFE IN RELATIONTO DEPTH OF DISCHARGE

    FLOAT SERVICE LIFE

    REM

    AINI

    NG C

    APAC

    ITY

    (%)100

    75

    50

    25

    0

    (AH%)

    120

    100

    80

    60

    40

    20

    0

    (V)14.0

    13.0

    12.0

    11.0

    10.0

    STORAGE TIME (MONTHS)

    PERC

    ENTA

    GE O

    F CA

    PACI

    TY A

    VAIL

    ABLE

    PERC

    ENTA

    GE O

    F CA

    PACI

    TY A

    VAIL

    ABLE

    NUMBER OF CYCLES

    TESTING CONDITIONS: DISCHARGE CURRENT: 0.17C AMP. (F.V. 1.7V/CELL)CHARGING CURRENT: 0.09C AMP.CHARGING VOLUME: 125% OF DISCHARGED CAPACITYAMBIENT TEMPERATURE: 200C TO 250C (680F TO 770F)

    TESTING CONDITIONS: FLOATING VOLTAGE 2.25 TO 2.30V/CELLAMBIENT TEMPERATURE: 200C TO 220C (640F TO 720F)

    OPEN

    CIR

    CUIT

    VOL

    TAGE

    REMAINING CAPACITY (%)

    3 6 9 12 15 18 0 20 40 60 80 100

    (AH%)120

    100

    80

    60

    40

    20

    0

    LIFE (YEARS)

    1 2 3 4 5 5.5

    200 400 600 800 1000 1200 1400

    200C (680F)

    AT 250C (770F)

    300C (860F)400C (1040F)

    30% DEPTH OF DISCHARGE50% D.O.D.100% D.O.D.

    PERC

    ENTA

    GE O

    F CA

    PACI

    TY A

    VAIL

    ABLE

    TEMPERATURE EFFECTS IN RELATIONTO BATTERY CAPACITY

    DISCHARGE CHARACTERISTIC CURVES AT 250C (770F)

    TERM

    INAL

    VOL

    TAGE

    Publ

    icat

    ion

    No:

    EN

    -NP2

    4-12

    R-01

    • Ja

    nuar

    y 20

    05Su

    bjec

    t to

    rev

    isio

    ns w

    ithou

    t pr

    ior

    notic

    e. E

    .&O

    .E.

    www.enersys.com

    EnerSys EMEABrussels, BelgiumTel:+32 (0)2 247 94 47

    EnerSys AsiaGuangdong, ChinaTel:+86-755-2689 3639

    EnerSys LimitedRake Lake,Clifton Junction,Swinton, ManchesterM27 8LR, UKTel:+44 (0) 161 794 4611Fax:+44 (0) 161 727 3809

    Global HeadquartersP.O. Box 14145Reading, PA 19612-4145USATel: +1-610-208-1991

    +1-800-538-3627Fax:+1-610-372-8613