560xl customer conference 2017 - cessna
TRANSCRIPT
• 510 Technical Review− Redbud Room 10:00 – 11:00
• 500 Series Technical Review− Redbud Room 11:00 – 12:00
• 650 Technical Review− Birch 10:00 – 11:00
• ADS-B Out – What’s Next For Textron Aviation− Birch 11:00 – 12:00
• Rockwell Collins PL21 and Fusion Updates, Field Issues and Obsolescence’s− Cedar 10:00 – 11:00 − Osage 11:00 – 12:00
• Jeppesen: JDM Enhancements & Introduction to Operator / Solver− Cedar 11:00 – 12:00
• Premier / Beechjet Pilot Round Table− Maple 10:00 – 11:00
• 525 & M2 Pilot Round Table− Maple 11:00 – 12:00
• CDMS & LinxUs− Osage 10:00 – 11:00
• General Aviation Safety and the NTSB Most Wanted− Oak 10:00 – 11:00
• Flight Department Management – Future Trends, Current Challenges− Oak 11:00 – 12:00
Concurrent Sessions
500 Series NBAA Technical Committee
• Dave Quale – Poet• Mark Werner – CBL & Associates Management• Dick Abernathy – Commerce Bank• John Bell – JB Aviation• Mark Chaney – Coca Cola Bottling Company Consolidated• Lance Ferguson – Commonwealth Eye Surgery• Michael Herman – Bear Air• Rich Pickett – Personal Wings, Inc• James Schmidt – Amway Aviation• Andy Shafer – Scottsdale Hangar One• Mike Strickland – Delhaize America • Patrick Taylor – Southwest Gas Corporation• Pat Welch – West Star Aviation, ALN• Chuck Zahnow – Duncan Aviation, BTL
Team Excel/XLS/XLS+
Ben WestermanPropulsion/Systems
Toll Free 877-560-3960 Intl +1 (316) [email protected]
Mark MetcalfAvionics/Electrical
Martin CranfordPropulsion/Systems
ExcelFleet Size: 369 AirplanesFleet Total Time: 2,262,136 HoursHigh Time Airplane: 13,206 HoursAverage Total Time: 6,301 Hours
XLSFleet Size: 329 AirplanesFleet Total Time: 1,445,896 Hours High Time Airplane: 11,314 HoursAverage Total Time: 4,408 Hours
XLS+Fleet Size: 224 AirplanesFleet Total Time: 298,255 HoursHigh Time Airplane: 8,144 HoursAverage Total Time: 1,320 HoursLast Airplane Delivered: 560-6230
Fleet Statistics Excel/XLS/XLS+
• Issue: ADS-B Out Mandate
• Resolution/Status: XLS+ Certification Complete
– New Aircraft Availability Starting Unit 560XL-6204
– SB560XL-34-76 Released In March– Service Bulletin Adds Wiring, ADS-B
FAIL Indicator, Circuit Breaker Change– Transponders Must Be Upgraded
Which Requires Advanced Scheduling– Must Be Complied With By Textron
Aviation Owned Facility
ADS-B OutExcel/XLS/XLS+
• Resolution/Status: Excel/XLS Certification Complete
– Optional SB560XL-34-77 Released June
• Revision 1 Also In June Revision 2 Released September
– Drawing Correction and Clarifications
• Requires WAAS/SBAS Capable FMS
• Requires Upgraded RM-855 RMUs
• Requires UNS-1EspW SCN 1000.8
ADS-B OutExcel/XLS/XLS+
• Issue: Aft Aileron Sector Corrosion
• Resolution/Status: Mandatory SL560XL-27-35 Released November 2015– Inspect Aft Aileron Sector
• Check For Evidence Of Corrosion On Upper Sector • Check For Drain Holes In Upper Sector
– Accomplish Within 180 Days At Document 4 Or Phase 21– Effects 560-5001 Thru -6075
Aft Aileron Sector InspectionExcel/XLS/XLS+
Aft Aileron Sector InspectionExcel/XLS/XLS+
Old Style Sector Without Drain Holes Tailcone Drains Above Sector Installation
Aft Aileron Sector InspectionExcel/XLS/XLS+
Old Sectors With No Drain Holes New Sector (-17 or -23)
Use A Borescope To Examine The Top Of The Sector.
EASA AD 2015-0093 LCR-100 AHRSXLS
• Issue: EASA AD Issued Against LITEF LCR-100 AHRS With Analog Syncro Output
– Only Aircraft With P/N 145130-7000 Affected
• Resolution/Status: Mandatory SB560XL-34-79 Released In March– Affected Aircraft Have 24 Months From AD Release To Replace Unit
• Affects Serial Numbers: -5783, -5792, -5804, -5811, -5813, -5816 and -5819– AFM Temporary Change Portion Of AD Not Applicable
• Textron Aviation Does Not Use Analog Output For Critical Functions– Engineering Certified New LITEF Part Number
LCR-93 To LCR-100 AHRS Parts SubstitutionExcel/XLS
• Issue: LCR-93 Parts Obsolescence
• Resolution/Status: Service Document In Work– Installs Certified LCR-100 Replacement– Service Document Will Provide Instructions To Modify Wiring – Effects Units 560XL-5002 thru -5758
• Units 5780 And On Delivered With LCR-100 Installed • Units 5759 Thru 5779 Had Wire Changes From Delivery
• Issue: Suspect Missing Fasteners Near Tailcone Access Door
• Resolution/Status: Mandatory SL560XL-53-18 January 2016– Affects Units 560-6001 Thru -6191– Inspect Three Locations At Forward Edge Of Tailcone Access Door
• Provides Instructions To Install Fasteners If Missing Stringers 15 And 16 Only• Revised SL Allows Two Fasteners Missing On Stringer 16
Tailcone Fastener InspectionXLS+
Tailcone Fastener InspectionXLS+
Inside Tailcone Looking Forward and Outboard
Missing Fasteners
S16 Two Fasteners Under Flange
EEC Wire Bundle RoutingXLS+
• Issue: Intermittent AC GENERATOR BEARING – R Messages
• Resolution/Status: Recommended SB560XL-24-19 Released in March– Affects Units 560-6001 Thru 6232– Provides Instructions To Inspect Right Alternator AC Wiring– Adds Clamp To Move And Secure Bundle
Rudder Position Sensor RoutingExcel/XLS/XLS+
• Issue: FDR Rudder Position Sensor Wiring May Interfere With Position Sensor Bellcrank
• Resolution/Status: Mandatory SL560XL-27-37 Rev 2 Released July 2016– Affects Units 560-6001 Thru -6193 With FDR or FDR Partial Provisions– Inspect Position Sensor Wiring– Adds Tie Wrap To Secure Wiring– Adds Mounting Clip Installation Instructions If Not Installed
Main Landing Gear Actuator Lock Tab Verification XLS+
• Issue: Main Landing Gear Lock Tab May Not Be Engaged in the Actuator Shaft.
• Issue: Main Landing Gear Lock Tab May Not Be Engaged in the Actuator Shaft.
• Resolution/Status: Recommended SL560XL-32-29 Released In January 2017– Affects Aircraft 560-6001 thru 6215– Jack Aircraft to Perform Inspection– Replace the Lock Tab if it is Deformed, Damaged, or Broken.
• Do the Main Landing Gear Wheel Camber Adjustment Procedure if the Grooves are Not in Alignment or if the Lock Tab was Replaced.
Main Landing Gear Actuator Lock Tab Verification XLS+
• Issue: XM Graphical Weather Loss Of Terminal Area Forecasts (TAF)
• Resolution/Status: Informational SL560XL-34-25 Released In June– Transmits Rockwell Collins Service Information Letter 16-1
• Disables Reset Override– National Weather Service Added 80 Airport Forecasts To Database
• Increased Airport Data Increased Data Transmission Time– Larger TAF Data Causes XM Receiver Watchdog Timer To Timeout
• TAF Package Continuously Restarts, Never Fully Received
XM Graphical Weather TAF LossXLS+
Copilot Left Brake Cylinder HoseExcel
• Issue: Copilot Left Rudder Pedal Bridge May Contact Left Master Cylinder Brake Hose
Copilot Left Brake Cylinder Hose Excel/XLS/XLS+
• Issue: Copilot Left Rudder Pedal Bridge May Contact Left Master Cylinder Brake Hose
• Resolution/Status: Optional SB560XL-32-43 Released March 2016– Affects Units 560-5001 Thru -5500– Replaces Brake Hose With 45 Degree Fitting– Adds Tie Wrap To Secure Hoses
• Issue: Possible Loose Ground Studs On Engine Fire Bottles– Could Prevent Bottle From Being Electrically Connected
• Resolution/Status: Released CIL-26-01 May 2016 To Inspect For Loose Ground Studs
– Squibs Replaced Or Manufactured Since April 2013 – Provides Instructions To Torque Ground Studs– Affects Units -5002 thru -6185– Compliance Within 3 Years Or 1200 Flight Hours Whichever Occurs First
Fire Bottle Cartridge Ground StudExcel/XLS/XLS+
Corrosion Protection ImprovementExcel/XLS/XLS+
• Issue: Landing Gear Corrosion Protection
• Resolution/Status: Model 560XL MM Revised To Include New Procedures– Notes Added For Lubricating Bolts On Installation
– Sealant And Anti-Seize Added To Many Landing Gear Components• Review Current Maintenance Manual Procedures When Changing Gear
Components– Service Bulletin In Work Improved NLG Bearing Installation And Grease
Procedures• Grease Points, Bearing Seals, Improved Bearing Grease
• Issue: Internal Corrosion Of Water Separator Housing
• Resolution/Status: CIL-21-03 Released October 2015 Transmits Honeywell SB 2341316-21-2828
– Provides Inspection Criteria– Provides Repair Procedures
• Repaired Part Number Changes
Water Separator CorrosionExcel/XLS/XLS+
RH AC Generator Wiring ChafeExcel/XLS/XLS+
• Issue: RH AC Generator Wiring Can Chafe the RH Motive Flow Tube
• Issue: RH AC Generator Wiring Can Chafe the RH Motive Flow Tube– RH AC Generator Wiring Routing– RH Motive Flow Fuel Tube Damage
• Resolution/Status: Mandatory SL560XL-24-07 Released January 2017– Inspect All Aircraft – Secure Wire Routing to Clear– Repair Chafed Wiring– Replace Damaged RH Motive Flow Tube Using Permaswage Fittings
RH AC Generator Wiring ChafeExcel/XLS/XLS+
AD 2017-04-14 Wiring Chafe InspectionExcel/XLS/XLS+
• Issue: AD 2017-04-14 Released Feb 22, 2017• AD Effective Date March 9, 2017• Require Completed SL560XL-24-07 Results Form Delivered to Team XL• Compliance Within 25 Flight Hours / 180 Days After Effective Date of AD• Special Flight Permits Not Allowed
• Issue: Loss of Hydraulic Pressure
• Resolution/Status: Recommended SL560XL-29-05 Engine Driven Hydraulic Pump Verification
– Replacement 9912062-7 Stamped with “A” Suffix on Serial Number• Inspect for Serial Number• Replace Suspect Pumps with Replacement 9912062-7 Pump• Incorporated on Production Airplanes 560-6221 and On
Hydraulic Pump ReplacementExcel/XLS/XLS+
Avionics Equipment Batteries
• Issue: Some Avionics Equipment Require “Keep Alive” Batteries– No Required Replacement Time– Battery Dependent Components Can Include
• Maintenance Diagnostic Computers (MDC)• Flight Management Computers (FMC) • Air Data Computers (ADC)
Avionics Equipment Batteries
• Resolution/Status:– Request CESCOM/CAMP Add Replacement Reminder
• Most Batteries Last Three to Five Years• Collins Replaces Batteries on Exchange Avionics if Battery is Over
One Year Old
• Issue: Maintenance Manual Procedures Missing For Engine Fault Troubleshooting
• Resolution/Status: Troubleshooting Trees Incorporated July 2016– Chapter 76-12-01 Engine Control Fault Indication -Troubleshooting
• Fuel Control Transfer Solenoid Fault• WOW Interface Fault• GND IDLE Annunciator Stays On After Takeoff
– Training Video Available On Txtavsupport.com (Accessing Engine Faults With Collins Proline 21 XLS+)
Engine Control Fault IsolationExcel/XLS/XLS+
Meggitt UpgradeExcel
• Issue: Meggitt Secondary Flight Display Upgrade
• Resolution/Status: SB560XL-34-54 Revision 2 Released In April 2016– Affects Units -5002 thru -5356– Provides Instructions to Install Meggitt iSFD (Integrated Secondary Flight
Display)• Mk1 and Mk2 Display Replacement
– Also Installs New Standby ADC As Mk1 Standby ADC Replacement
Kollsman Pressurization Troubleshooting
• Issue: Enviro Systems Inc. (Formerly Kollsman) Reported Significant Increase In No Fault Found Returned Components Due To Misdiagnosed Pressurization Issues
• Resolution: Kollsman Expert System Located On www.txtavsupport.comAssists Troubleshooting Pressurization Issues
– If Encountering Java System Security Errors Will Need To Add https://support.cessna.com To Trusted Sights Tab In Java Security Settings
Kollsman Pressurization Troubleshooting
• Issue: Improper Maintenance Practices May Induce Pressurization Faults• Resolution: Ensure Maintenance Manual Procedures Followed/Leak Check
of the Manual Pressurization Hoses/Fittings Post Maintenance– Maintenance Manual Procedures State Manual Pressurization Fittings Only be
Tightened ¼ Turn Beyond Hand Tight, Overtightening Can Damage Fittings/Hoses and Cause Leaks
– A Leak Check Of Manual Pressurization Lines Must Be Performed Following Maintenance That Involves Manual Pressurization Lines, Including Outflow Valve Replacement
TEXTRON Customer ConferenceCitation 560XL - PW545 Engines
April 2017
P&WC Proprietary InformationExport Classification: No Technical Data
.
PROPRIETARY RIGHTS NOTICEThis document is the property of Pratt & Whitney Canada Corp. (P&WC). You may not
possess, use, copy or disclose this document or any other information in it, for any purpose, including without limitation to design, manufacture, or repair parts, or obtain FAA or other Government approval to do so, without P&WC express written permission. Neither receipt
nor possession of this document alone, from any source, constitutes such permission.Possession, use, copying or disclosure by anyone without P&WC’s express written
permission is not authorized and may result in criminal or civil liability.
NOTICE - DISCLOSURE OF INFORMATIONThis document contains trade secrets or other confidential information the further Disclosure of which may be harmful to Pratt & Whitney Canada Corp. If the head of
a Government agency or department intends to disclose any of this information,written notice should be given to the Vice President - Legal Services,
Pratt & Whitney Canada Corp., 1000 Marie Victorin (01BE5), Quebec, J4G 1A1.
EXPORT CLASSIFICATION
Classification Instructions: Complete 1. AND at least one of 2-5.If unsure contact your BAER.
1. Canadian ECL(s): NLR Put NLR (No License Required) if there is no ECL controlled technical data or replace with actual classification (e.g. 1-9.E.3.a.3)
2. ECCN(s):
3. P-ECCN(s): 9E991 Contains only non – U.S. origin civil/dual-use data (e.g. 9E991, 9E003).Do not use if an ECCN is provided.
4. USML: Contains US-origin ITAR - controlled technical data (e.g. VIII(i)). Leave blank if no US data.
5. P-USML: Contains non US-origin technical data equivalent to USML (e.g., VIII(i)). Do not use if an ITAR classification is provided.
54
PW545 AGENDA
GLOBAL SUPPORT
OIL ANALYSIS
FLEET STATISTICS
OIL SERVICING
HPC ROTOR 2 DISTRESS
BOV ORIFICE SIZING
ELECTRONIC ENGINE CONTROL
JFC160 FUEL CONTROL
PW545 TBO EXTENSION
PUBLICATIONS
P&WC Proprietary InformationExport Classification: No Technical Data
55
CUSTOMER FIRST CENTRES
VISION Proactive approach to our customers needs with tailoredtechnical support.
MISSION Keep our customers flying with a 24/7/365 technical support thatcovers fleet monitoring to AOG event management.
Longueuil Team Singapore Team
Export Classification: No Technical Data P&WC Proprietary Information
56
CUSTOMER FIRST CENTRE24-hour 7 days a week event
management, technical and commercial support
email: [email protected]
In Canada and United StatesTel: 1-800-268-8000
InternationalInter. Access Code+ 8000-268-8000Tel: (450) 647-8000
Fax:(450) 647-2888
Export Classification: No Technical Data P&WC Proprietary Information
57
CUSTOMER PORTAL
To register for the Portal use the convenient link on the P&WC home page
athttp://www.pwc.ca
or go to
http://eportal.pwc.ca
Export Classification: No Technical Data P&WC Proprietary Information
5858
My Customer Dashboard Online buying
Mobility
Integrated Cart Portal-wide search
A POWERFUL NEW CUSTOMER PORTALRelease 1.0 of the My P&WC Power customer portal is a first step towards market leadership in digital services.
Export Classification: No Technical Data P&WC Proprietary Information
59
Bridgeport
Montreal
BurlingtonLong Beach
Lethbridge
Atlanta
Wichita
Luton
Lanseria
Singapore
Brisbane
Berlin
Sorocaba
AmsterdamMichigan
Service Centers & DOF Parts DistributionFly-in Capability
10,000+ Customers… 200 Countries… 50,000 Engines… 614 Million hours
Service Centers Rental Engines Customer First Field Service Mobile Repair Teams
Toronto
Moscow
Sydney
China
Memphis
Worldwide Services7 Parts Distribution Centers 13 Service Centers17 Independent Facilities100 Field service representatives100 Mobile Repair Teams
Export Classification: No Technical Data
GLOBAL SUPPORT NETWORK
P&WC Proprietary Information
60
P&WC OIL ANALYSIS TECHNOLOGY AT A GLANCE
REVOLUTIONARY OIL ANALYSIS
Monitors the health of oil‐wetted engine components including bearings, carbon seals and gears
Improved precision/sensitivity: Know where it is happening earlier
Demonstrated and proven on specific engines
POTENTIAL BENEFITS FOR OPERATORS
Lower maintenance costs
Predictable maintenance budget planning
Reduce delays and cancellations
Increase aircraft resale value
FROM REACTING TO ANTICIPATINGTOWARD A 100% PLANNED MAINTENANCE ENVIRONMENT
FROM REACTING TO ANTICIPATINGTOWARD A 100% PLANNED MAINTENANCE ENVIRONMENT
UNDER DEVELOPMENT AT THIS TIME
Export Classification: No Technical Data P&WC Proprietary Information
61
Interested in participating? P&WC Proprietary Information
Export Classification: No Technical Data
Interested in participating?
P&WC Proprietary Information
Visit our website for more information
pwc.ca
62
PW545 FLEET STATISTICSMarch 2017
P&WC Proprietary InformationExport Classification: No Technical Data
Cessna Citation Excel
Cessna Citation XLS
Cessna Citation XLS+
Model PW545A PW545B PW545C
Total Produced 774 688 479
Flying population
734 658 438
Total Hours 4,653,400 3,120,300 617,800
High Time / ESN 12,947 10,870 6,593
1st Delivery Sep – 1998 Jul – 2004 Dec – 2008
Total Fleet Hour: 8,391,500 Total Produced: 1941
63
OIL SERVICING – LOW OIL PRESSURE
P&WC Proprietary Information
Adherence to Engine Maintenance Manual Oil Servicing Procedures is critical
IssueMultiple reported events of low/loss of main engine oil pressure
CauseIncorrect oil servicing practice, setting the oil level too low
SolutionImproved oil level indicatorService Bulletin SB30508 published Jan’15Engine Maintenance Manual revised May’16SIL PW500-065 Oil Servicing 19 May’16Video – Oil Servicing PW545 28 Nov’16Canadian Airworthiness AdvisoryCASA No. 2016-13 9 Dec’16
Export Classification: No Technical Data
64
PW545B HPC ROTOR 2 DISTRESSIssue4 events of HPC 2nd stage rotor airfoil distress,3 – IFSD, and 1- DIVData suggests issue isolated to PW545B but PW545C not ruled out
CauseUnder investigation by P&WC
Interim SolutionImplemented logistics to replace HPC2 rotors at overhaul shop visitService Information Letter SIL PW500-067 Feb’17
P&WC Proprietary InformationExport Classification: No Technical Data
BOV ORIFICE SIZING
IssueBOV orifice sizing after torque motor replacement
CauseOptional procedure may be too stringent for aging hardware
SolutionEngine Maintenance Manual will be amended to remove the optional procedure
Requirement of OrificeEngine achieves power of the dayEngine does not surge
Chart for Optional procedure
Export Classification: P-ECCN: 9E991P&WC Proprietary Information
66Export Classification: P-ECCN: 9E991
P&WC Proprietary Information
ELECTRONIC ENGINE CONTROL545C EEC
EEC500
IssueTransient voltage suppressor (TVS) faultsEarly production Low Voltage Power Supply (LVPS) faults
CauseTVS – manufacturing processLVPS – solder joint flaw, batch related
SolutionRetrofit campaign to correct TVS and capture LVPS batchService Bulletin 30478 revised to category 3 15 Jul’15
Commercial Support Program issuedPW545C CSPN 1006723 15 Jul’15CSPN closure Dec 2017
Status
Mar 2017PW 545C, P/N 101240087% complete
67
JFC160 FUEL CONTROL
Export Classification: P-ECCN: 9E991
Issue4 Events of unscheduled FCU removal due to liberated N2 Flyweight Governor bearing post SB30442 (Zero Backlash)
CauseField returned hardware inspection demonstrated varyinglevels of wear.
Solution Bushing type bearing to replace governor ball bearings
Interim SolutionField refresh activity for units over 1000 hrs TSR
Service Bulletin 30512 published Dec’14Commercial Support Program availableCSPN #1007421
Distressed crown retainer
P&WC Proprietary Information
Redesigned Bearing
PW545A PW545B
68
PW545 TBO EXTENSIONAlternative TBO – 5500 hours
P&WC has completed an analysis supporting a proposed alternative TBO interval of 5500 hours.
The alternative TBO is applicable to PW545A/B/C engines which meet the following criteria:
The participation in an engine condition trendmonitoring (ECTM) program, as defined in the P&WC Publication SIL No. GEN-055, is requiredfrom new engine delivery or from a scheduledmaintenance event (HSI / Overhaul).
A list of Service Bulletins to each specificmodule.
StatusMaintenance Manual revised & published 12 Dec’16
PW545A/B/C
P&WC Proprietary InformationExport Classification: P-ECCN: 9E991
Example of EMM Chapter 05-20-00 Scheduled Maintenance Check
69
PUBLICATIONS Maintenance Manual/IPC
Planned next PW500 revisions: June 2017
Service Information Letters / Civil Aviation Safety Alert (Transport Canda)SIL PW500-067 High Compressor Rotor 2nd stageSIL GEN-122R4 Recovery Fee for Maintenance Deviation LettersCASA No. 2016-13 Oil System Servicing
Available Commercial Support Programs CSPN# Ends
Deep Sump (SB30413) 1005541 Dec 2018Oil System Stability (SB30479) 1006977 Dec 2018Rigid Fuel Manifold (SB30405) 1005989, 1006443 Nov 2022Electronic Engine Control (SB30478) 1006723 Dec 2017HFC Inspection (SB30512) 1007421 Jun 2017
P&WC Proprietary InformationExport Classification: No Technical Data
Technical Panel
LARGE CABIN JETS MANAGER – JOHN SZELENYIPROJECT ENGINEERING – AARON HEIMANAES ENGINEERING – RON SHARPFLIGHT TEST – JON COOPERPRATT & WHITNEY CANADA – JOHNNY MARCHETTITEAM EXCEL/XLS/XLS+ – MARK METCALF / BEN WESTERMAN