5a carson road, malaga wa 6090 w www ...€¦ · 5a carson road, malaga wa 6090 w e...

12
5a Carson Road, Malaga WA 6090 W www.statewestbuildingsupplies.com E [email protected] P (08) 9248 8041 F (08) 9248 8731

Upload: others

Post on 19-Aug-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 5a Carson Road, Malaga WA 6090 W www ...€¦ · 5a Carson Road, Malaga WA 6090 W  E contact@statewestbuildingsupplies.com P (08) 9248 8041 F (08) 9248 8731

5a Carson Road, Malaga WA 6090W www.statewestbuildingsupplies.com

E [email protected] (08) 9248 8041 F (08) 9248 8731

Page 2: 5a Carson Road, Malaga WA 6090 W www ...€¦ · 5a Carson Road, Malaga WA 6090 W  E contact@statewestbuildingsupplies.com P (08) 9248 8041 F (08) 9248 8731

 

 

Polastic Insulation System

for TRANSPORTABLE HOMES

Page 3: 5a Carson Road, Malaga WA 6090 W www ...€¦ · 5a Carson Road, Malaga WA 6090 W  E contact@statewestbuildingsupplies.com P (08) 9248 8041 F (08) 9248 8731

Polastic Insulation System TRANSPORTABLE HOMES

Page 2

Section Title Page

Index 2 Transportable Homes 3

Product Information 4

Specification 5-6

Additional Resources 7

Contact 7

Appendices

R-Values Certificates 8-11

Index

Page 4: 5a Carson Road, Malaga WA 6090 W www ...€¦ · 5a Carson Road, Malaga WA 6090 W  E contact@statewestbuildingsupplies.com P (08) 9248 8041 F (08) 9248 8731

 

 

 

TRANSPORTABLE HOMES

Finally, Insulation for Inside Living!

Web www.proactivetechnology.com.au Email [email protected] Tel 02 9435 4144  

A transportable home must be liveable, energy efficient and able to combat the harsh Australian climate. Polastic Insulation System is a total insulation solution for transportable homes, designed to seal up the building against air leakage, creating an ‘esky effect’ and reducing energy consumption.  

§ Effectively reduces all 3 types of heat transfer - conductive, convective and radiant.

§ Made in Australia.

§ Only Polastic Insulation System provides the ‘Esky effect’ - a sealed internal envelope insulated from the elements.

§ Replaces 3 products in 1. A single application of Polastic Insulation System can provide a thermal break, vapour barrier and slim profile insulation.

§ Entirely non-conductive and non-corrosive. Polastic Insulation System is recyclable and energy efficient, reducing a building’s carbon footprint.

§ Available in Sheets W1200 x

Sheet Dimensions W1200 x L2400 x Thickness 7, 10, 12, 16, 20, or 25mm Roll Dimensions W1200mm x L24m x Thickness 7 or 12mm  

Page 5: 5a Carson Road, Malaga WA 6090 W www ...€¦ · 5a Carson Road, Malaga WA 6090 W  E contact@statewestbuildingsupplies.com P (08) 9248 8041 F (08) 9248 8731

Polastic Insulation System  

Polastic Insulation System is available in sheets and continuous rolls to suit all Roof, Ceiling, Wall and Floor Applications (available in Standard or Permeable). Sheets available in 7mm, 10mm, 12mm, 16mm, 20mm and 25mm thicknesses (W1200mm x L2400mm) Rolls available in 7mm or 12mm thicknesses (W1200mm x L24m) 7mm or 12mm x

W1200mm x L24m

Product Range

Only Polastic Insulation System provides a 3-in-1 application including a thermal break, efficient insulator and vapour/air barrier, in a non-conductive, reflective and highly flexible insulation sheet or continuous roll.

Polastic Insulation System works to effectively reduce all 3 types of heat transfer including:

The key to Polastic Insulation System's superior insulation properties lies in an innovative combination of two highly advanced materials working together to keep the heat outside in summer and inside in winter by creating an Esky effect in the home.

The shielding properties of the highly flexible, specially engineered Expanded Polystyrene (EPS) core together with the thermal blocking power of the ultra-thin, reflective plastic facer (similar to Mylar developed by NASA) combine to make Polastic Insulation System one of the most effective, thin profile insulation solutions available in Australia!

§ Non-conductive § Non-corrosive § No CFCs, HCFCs § Made in Australia

 

Email [email protected] www.proactivetechnology.com.au

Page 6: 5a Carson Road, Malaga WA 6090 W www ...€¦ · 5a Carson Road, Malaga WA 6090 W  E contact@statewestbuildingsupplies.com P (08) 9248 8041 F (08) 9248 8731

Polastic Insulation System TRANSPORTABLE HOMES

Page 5

DATE: Insert PROJECT: Insert BUILDER: Insert ARCHITECT: Insert PRODUCT: POLASTIC INSULATION SYSTEM MANUFACTURER: PROACTIVE TECHNOLOGY AUSTRALIA PTY LTD TABLE OF CONTENTS 1.0 GENERAL 1. 1 SCOPE OF WORK “POLASTIC INSULATION SYSTEM” - INSULATION 1. 2. STANDARDS -INSULATION 1. 3 INSPECTIONS – INSULATION 2.0 MATERIALS DESCRIPTION 2.1 “POLASTIC INSULATION SYSTEM” INSULATION SHEETS/ROLLS – INSULATION 2.2 “POLASTIC INSULATION SYSTEM” SEAM TAPE – INSULATION 2.3 “POLASTIC INSULATION SYSTEM” FIXINGS AND ACCESSORIES – INSULATION 1.0 GENERAL (please delete “items” not relevant to your specification) 1.1 SCOPE OF WORK “POLASTIC INSULATION SYSTEM” INSULATION General: Please refer to the R-Values Certificate for certified R-Values for “POLASTIC INSULATION SYSTEM” for all building configurations issued by Proactive Technology Australia Pty Ltd. Extent: Please refer to the installation recommendations for “POLASTIC INSULATION SYSTEM” for all building configurations issued by Proactive Technology Australia Pty Ltd.

Application R-Value

Certificate Reference

R-Value Required

Polastic Thickness Required

(mm)

Installation Reference

Metal Roof 2(A)1S 4.1 7mm

External Wall PWWFXE2 2.8 20mm

Suspended Floor – Option 1 THF1 R2.25 7mm

Suspended Floor – Option 2 THF2 R2.25 7mm

Please refer to the following information available online: R-Value Certificates: http://www.proactivetechnology.com.au/pages/r-values.php Installation Manual: http://www.proactivetechnology.com.au/pages/installation-manual.php Technical Information: http://proactivetechnology.com.au/pages/downloads-page.php

Specification (Page 1 of 2)

Page 7: 5a Carson Road, Malaga WA 6090 W www ...€¦ · 5a Carson Road, Malaga WA 6090 W  E contact@statewestbuildingsupplies.com P (08) 9248 8041 F (08) 9248 8731

Polastic Insulation System TRANSPORTABLE HOMES

Page 6

DATE: Insert PROJECT: Insert BUILDER: Insert ARCHITECT: Insert PRODUCT: POLASTIC INSULATION SYSTEM MANUFACTURER: PROACTIVE TECHNOLOGY AUSTRALIA PTY LTD 1.2 STANDARDS – INSULATION

General: Included: The following standards and codes are applicable to the Works included in this Section, and unless otherwise described in this Specification shall be regarded as describing the minimum standard of materials and workmanship to be provided. AS 1366.3-1992 Rigid cellular polystyrene - moulded AS/NZS 4859.1-2001 Materials for the thermal insulation of buildings

1.3 INSPECTIONS – INSULATION Witness points:

Notice: Give sufficient notice so that inspection may be made of the following: a. Building framing or substrates prior to installing insulation b. On completion of installing insulation and prior to insulation being covered up or concealed

2.0 MATERIALS DESCRIPTION

2.1 “POLASTIC INSULATION SYSTEM” INSULATION SHEETS/ROLLS – INSULATION Description:

Proprietary item: POLASTIC INSULATION SYSTEM (Patent pending) Insulation Sheets and/or Continuous Rolls manufactured by Proactive Technology Australia Pty Ltd. Sheet size: 2400 x 1200mm available in 7, 10, 12, 16, 20 or 25mm thickness. Roll size: 1200mm x 24m (approx.) available in 7 or 12mm thickness. Edges: Square cut. Standard: Manufactured to comply with AS/NZS 4859.1-2001. Building Code of Australia: All thicknesses of Polastic Insulation System satisfy the requirement for a thermal break. Options: Polastic Insulation System is available in Standard and Permeable options. Three-in-one Application: When installed correctly Polastic Insulation System provides: 1.Thermal Break; 2.Vapour Barrier; 3. Slim Profile Insulation - in a single product application. Insulation panel: Polastic Insulation System has an entirely non-conductive, reflective plastic facer bonded to a polystyrene core with anti-glare on one side. - One side of insulation panel to be coated with an anti-glare coating to reduce reflectivity, product has 100 x 100mm cutting guide lines and manufacturer’s brand name. - Both sides (anti glare and reflective side) have an emissivity of less than 0.03. White finish has a perfect emissivity of 0.0000 - Polystyrene core complying with AS 1366.3-1992 - Adhesive bonding of the outer reflective plastic facer to the polystyrene core: Heat resistant type able to sustain a temperature of 100°C without causing delaminating of the facer from the polystyrene core of the insulation panel.

2.2 “POLASTIC INSULATION SYSTEM” SEAM TAPE – INSULATION

General installations: Proprietary item: POLASTIC INSULATION SYSTEM Seam Tape manufactured by Proactive Technology Australia Pty Ltd.

2.3 “POLASTIC INSULATION SYSTEM” FIXINGS AND ACCESSORIES – INSULATION

Please refer to the installation manual for Polastic Insulation System, issued by Proactive Technology Australia Pty Ltd.

End of Specification

Specification (Page 2 of 2)

Page 8: 5a Carson Road, Malaga WA 6090 W www ...€¦ · 5a Carson Road, Malaga WA 6090 W  E contact@statewestbuildingsupplies.com P (08) 9248 8041 F (08) 9248 8731

Polastic Insulation System TRANSPORTABLE HOMES

Page 7

To access additional technical and product information please refer to the following online resources:

About Polastic Insulation System

http://www.proactivetechnology.com.au

R-Value Certificates

http://www.proactivetechnology.com.au/pages/r-values.php

Installation Manual

http://www.proactivetechnology.com.au/pages/installation-manual.php

Technical Information

http://proactivetechnology.com.au/pages/downloads-page.php

Technical Enquiries

Jasmin Aleknavicius - Director Proactive Technology Australia Pty Ltd Mail PO Box 299, Lindfield NSW 2070 Web www.proactivetechnology.com.au Email [email protected] Office 02 9435 4144 Mobile 0433 221 471

Sales Enquiries

Please refer to our website to locate your nearest Supplier or Installer:

http://www.proactivetechnology.com.au/pages/suppliers.php

Additional Resources

Contact

Page 9: 5a Carson Road, Malaga WA 6090 W www ...€¦ · 5a Carson Road, Malaga WA 6090 W  E contact@statewestbuildingsupplies.com P (08) 9248 8041 F (08) 9248 8731

2(A)1  Skillion  Metal  Roof,  Concealed  Rafters,  Plasterboard  Ceiling,Polastic  Under  Roof

Unventilated  roof  space

Plasterboard  ceiling  lining

Metal  roof  sheeting  on  battens

Rafter

POLASTIC  insulation

R-VALUES System Reference 2(A)1S

Skillion Metal Roof, Concealed Rafters, Plasterboard Ceiling, Polastic Under Roof

Polastic Thickness

Summer R-Value

7mm 4.1

BCA Vol. 1, Table J1.3a Rt3.2-Rt4.2 Summer Climate Zones 1 to 6; and Rt3.7 Winter Climate Zone 7.

BCA Vol. 2, Table 3.12.1.1a Rt4.1 Summer Climate Zones 1 and 2 (<300m); and Rt4.1 Winter Climate Zones 2 (>300m) to 7 (where solar absorptance of roof cladding is not greater than 0.4).

Meets or exceeds the BCA 2011 Deemed-to-satisfy thermal performance requirements in accordance with BCA 2011 Vol. 2, Table 3.12.1.1a; Vol. 1, Table J1.3a; and AS/NZS 4859.1 and certified by an independent engineering consultant.

PDF 2(A)1S System R-Values Revision 1.0 Jun 2012

Brought(to(you(by(

Proactive Technology Australia Pty Ltd ABN 59 138 686 254 Mail PO Box 299, Lindfield NSW 2070 Tel (02) 9435 4144 Fax (02) 8088 0728 Email [email protected] Web www.proactivetechnology.com.au

Page 10: 5a Carson Road, Malaga WA 6090 W www ...€¦ · 5a Carson Road, Malaga WA 6090 W  E contact@statewestbuildingsupplies.com P (08) 9248 8041 F (08) 9248 8731

R-VALUES System Reference PWWFXE2

A: Weatherboard B: Polastic

C: 70mm Frame D: 10mm Plasterboard

Polastic

Thickness R-Value

7mm 1.8

20mm 2.8* Rt2.4 to Rt2.8 required for external walls in BCA 2011 Vol. 2, 3.12.1.3a for Climate Zones 1 to 7. *Meets or exceeds the BCA 2011 Deemed-to-satisfy thermal performance requirements in accordance with BCA 2011 Vol. 2, Table 3.12.1.3a and AS/NZS 4859.1 and certified by an independent engineering consultant.

PDF 5(ED)2 System R-Values Revision 2.0 Jun 2012

Brought to you by Proactive Technology Australia Pty Ltd ABN 59 138 686 254 Mail PO Box 299, Lindfield NSW 2070 Tel (02) 9435 4144 Fax (02) 8088 0728 Email [email protected] Web www.proactivetechnology.com.au

Page 11: 5a Carson Road, Malaga WA 6090 W www ...€¦ · 5a Carson Road, Malaga WA 6090 W  E contact@statewestbuildingsupplies.com P (08) 9248 8041 F (08) 9248 8731

R-VALUES System Reference THF1

Suspended Floor Enclosed, Polastic Applied on

Underside of Ply Floor with Ground Floor Resistance

Polastic Thickness

Downwards R-Value

7mm 2.25

Rt1-3.25 required for suspended floors in Vol. 2, Table 3.12.1.4 for Climate Zones 1 - 8. Meets or exceeds the BCA 2011 Deemed-to-satisfy performance requirements in accordance BCA 2011 3.12.1.4 and AS/NZS 4859.1 and certified by an independent engineering consultant

PDF THF1 System R-Values Revision 1.0 Nov 2012

Proactive Technology Australia Pty Ltd ABN 59 138 686 254 Mail PO Box 299, Lindfield NSW 2070 Tel (02) 9435 4144 Fax (02) 8088 0728 Email [email protected] Web www.proactivetechnology.com.au

Page 12: 5a Carson Road, Malaga WA 6090 W www ...€¦ · 5a Carson Road, Malaga WA 6090 W  E contact@statewestbuildingsupplies.com P (08) 9248 8041 F (08) 9248 8731

R-VALUES System Reference THF2

Suspended Floor Unenclosed,

Polastic Applied on Underside of Floor Joists with Enclosed Reflective Air Space

Polastic Thickness

Downwards R-Value

7mm 2.25

Rt1-3.25 required for suspended floors in BCA 2011 Vol. 2, Table 3.12.1.4 for Climate Zones 1 - 8. Meets or exceeds the BCA 2011 Deemed-to-satisfy performance requirements in accordance BCA 2011 3.12.1.4 and AS/NZS 4859.1 and certified by an independent engineering consultant

PDF THF2 System R-Values Revision 1.0 Nov 2012

Proactive Technology Australia Pty Ltd ABN 59 138 686 254 Mail PO Box 299, Lindfield NSW 2070 Tel (02) 9435 4144 Fax (02) 8088 0728 Email [email protected] Web www.proactivetechnology.com.au