LED Gimbal Down Light Can Retrofit Fixture Important: Read all instructions prior to installation. DL56DS-NW15W User Manual Part Number: Disk Down Light Can Retrofit LED Fixture DL56DS-NW15W Installation Manual Rev Date: V1 12/18/17 Rev Date: V1 12/18/17 Recessed Housing Compatibility 1. Push the black wire from the fixture into the + wire terminal of the female connector and the white wire from the fixture into the - terminal of the female connector. (fig 1) 2. Push the black wire from the socket adapter into the + wire terminal of the male connector and the white wire from the socket adapter into the - terminal of the male connector. (fig 1) 3. Unscrew the two large screws on the top of the fixture and use them to attach the torsion springs to the fixture in either the 5” or 6” position. (fig. 2) 4. Twist the socket adapter into the socket. (fig 3.) 5. Connect the male and female connectors.(fig. 4) 6. Squeeze both torsion spring arms together and insert into torsion spring slots (or receiver brackets) of can (fig. 4). Tuck all wires into can and carefully push retrofit trim into can. To provide enough room in shallow cans, carefully position socket adapter wiring to side of LED driver prior to inserting retrofit trim into the can. Dimmer Compatibility Brand Lutron Leviton Model DVCL-153P-WH 6683 MACL-153M-WH 6672 S-600PR-WH 6631 SPSLV-600-WH 6633-P DVLV-603P-IV 1A23O5 MALV-600-IV 0B33K1 MALV-600 DVW-603PGH-WH 4X603 CTCL-153P SLV-600P-WH CT-603PG NT-1000 S-603P DV-600P RA-6D

Upload: others

Post on 12-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 5yr Rev Date: V1 12/18/17 · 2018-05-21 · LED Gimbal Down Light Can Retrofi t Fixture Important: Read all instructions prior to installation. DL56DS-NW15W User Manual Part Number:

LED Gimbal Down Light Can Retrofi t FixtureImportant: Read all instructions prior to installation. DL56DS-NW15W

User ManualPart Number:

Disk Down Light Can Retrofi t LED Fixture

DL56DS-NW15W

Installation Manual

5yrRev Date: V1 12/18/17Rev Date: V1 12/18/17

Recessed Housing Compatibility

1. Push the black wire from the fi xture into the + wire terminal of the female connector and the white wire from the fi xture into the - terminal of the female connector. (fi g 1)

2. Push the black wire from the socket adapter into the + wire terminal of the male connector and the white wire from the socket adapter into the - terminal of the male connector. (fi g 1)

3. Unscrew the two large screws on the top of the fi xture and use them to attach the torsion springs to the fi xture in either the 5” or 6” position. (fi g. 2)

4. Twist the socket adapter into the socket. (fi g 3.)5. Connect the male and female connectors.(fi g.

4)6. Squeeze both torsion spring arms together

and insert into torsion spring slots (or receiver brackets) of can (fi g. 4). Tuck all wires into can and carefully push retrofi t trim into can. To provide enough room in shallow cans, carefully position socket adapter wiring to side of LED driver prior to inserting retrofi t trim into the can.

Dimmer Compatibility

Brand Lutron LevitonModel DVCL-153P-WH 6683

MACL-153M-WH 6672S-600PR-WH 6631

SPSLV-600-WH 6633-PDVLV-603P-IV 1A23O5MALV-600-IV 0B33K1

MALV-600DVW-603PGH-WH

4X603CTCL-153P

SLV-600P-WHCT-603PGNT-1000S-603P

DV-600PRA-6D

Page 2: 5yr Rev Date: V1 12/18/17 · 2018-05-21 · LED Gimbal Down Light Can Retrofi t Fixture Important: Read all instructions prior to installation. DL56DS-NW15W User Manual Part Number:

DL56DS-NW15W

User ManualPart Number:

Installation Instructions Surface Mount Instructions:

Removing LED Luminaires:

Dimming:

LED Disk Down Light Can Retrofit FixtureImportant: Read all instructions prior to installation.

1. Align holes in junction box with corresponding holes on junction box mounting plate. Using screws provided, attach junction box mounting plate to the junction box so that it is flush with the ceiling. Do not overtighten screws. (fig 1 &2)

2. Connect hot, neutral, and ground wires on fixture to the hot, neutral, and ground wires in the junction box using wire nuts. (fig 3) Then push wires back inside of junction box.

3. Align the two mounting clips on the fixture to the mounting clip holes in the junction box mounting plate and gently push the fixture upward until it locks in place. (fig.3)

1. With fingertips, pull down firmly on trim ring until fixture stops.

2. Squeeze torsion springs together to remove LED fixture.

3. Disconnect fixture from socket adapter.4. Unscrew socket adapter from recessed can.

Rev Date: V1 12/18/17

Wiring Diagram

R e pla c in g L E D L u m in a ir e s :.With fingertips,pull down firmly on trim ring until module stops..Squeeze torsion springs together to remove LED module..Disconnect LED module wiring from recessed can (LED Connector or screw in Edison base.)

In s ta l la tio n i n to H o u s in g s :

W a r r a n ty :We offer 5 years limited warranty.As with any electrical

installation,a qualified electrician must ensure compatibility

of use with a particular housing;this includes all applicable

national and local electrical and building codes.Installer is

responsible to securely retain the LED Module in a housing

at time of installation.

FIG.4 FIG.5

FIG.2 FIG.3

1.Loosen torsion spring bracket with screw;If install into 6" can housings:Remove 2 torsion springbrackets completely to keep them in the out ward postion. (FIG.1-1)If install into 5" can housing: Slide bracket to inward position.(FIG.1-2)Then,Tighten screw.

5.Squeeze both torsion spring arms together and insertinto the torsion spring slots (or receiner bracktes) of thecan.Tuck all wires into the can and carefully push the retrofit trim into can (note:to provide enough room inshallow cans carefully position socket adapter andsocket adjacent to the long side of the LED driver priorto inserting the retrofit tirm into the can.(FIG.5)

4.Plug the female connector of the retrofit trim onto themale connector of the socket adapter assembly.(FIG.4)

3.Thread the socket adapter into the socket.(FIG.3)

2.Unscrew the wing nut inside the can , Upwards move the socket bracket to max from the can.(FIG.2)

P a c k in g L is t:1.LED luminaire(with LED Driver)2.18# Black/White connecting wire with E26 lamp holder (for L/N input)

The LED luminaire can be dimmed with many standard incandescent dimmers,however an electronic low voltage version of a standard dimmer (with neutral connection ) is recommended for many applications.Updates in dimmer technology and special conditions may apply depending on the dimmer type being used.To be assured of the latest information regarding luminaire and dimmer compatibility,please contact dimmer manufacturer.

D im m in g :

Downlight

DIMMER

GND

AC120

N

L

Downlight Downlight

FIG.1-1 FIG.1-2

6"

5"

5-6in c h

E26 SOCKET ADAPTER

LUMINAIRE

Specifications

DLD4-NW9WOperating Voltage Range 120 VACBeam Angle 110 degreeLED Type / Quantity COB / 1 pcsIntensity 1050 lumenColor Temperature 4000KCRI >90Operating Temperature -22 ~ 122°F

(-30 ~ 50 °C)Total Power Consumption 15 WattsDimmable Yes (Triac)Standards and Certifications ETLFixture Weight 14 oz (0.40Kg)Warranty 5 year

Included Parts

1 - LED Disk Down Light Can Retrofit Fixture1 - E26 Socket Adapter1 - Junction Box Mounting Plate

2 - Torsion Springs1 - Male Connector4 - Screws1 - Female Connector3 - Wire Nuts

• CAUTION SHOCK AND FIRE HAZARD, DO NOT USE WHEN ENCLOSURE IS BROKEN.• SUITABLE FOR USE IN ENCLOSED RECESSED LUMINAIRES.• SUITABLE FOR DAMP LOCATIONS.• SUITABLE FOR TYPE IC OR FOR TYPE NON-IC.

Safety and Notes

1. To avoid possible electrical shock, be sure that power supply is turned off at fuse box or circuit breaker before installing or servicing fixture.

2. For indoor use only, suitable for damp locations, avoid direct contact with water and other liquids.

3. Clean with a soft damp cloth only, do not use any chemical cleaners.

4. Before installation of any recessed lighting luminaire check your local electrical code. This code sets the wiring standards for your locality and should be carefully studied before starting.

5. The luminaire light can be dimmed with a standard triac dimmer.

Dimming performance may depend on the dimmer, the dimmer range adjustment setting (for dimmers with brightness range adjustments), the wiring method, and/or the number of LED modules installed onto the dimmer circuit. For dimmer selection, Dimming control manufacturers revise their product often; for the latest list of compatible dimmers please visit our website.For best results, it is recommended to install a minimum of four LED modules onto one dimmer. Before turning on the LED lights, set dimmer position at maximum before adjusting to a lower light level. Please follow the dimming control manufacturer’s instructions for the installation of all dimming controls.

We offer 5 years limited warranty. As with any electrical installation, a qualified electrician must ensure compatibility of use with a particular housing. This includes all applicable national and local electrical and building codes. Installer is responsible to securely install LED fixture into housing at time of installation.

Warranty Information