6-sgsn9810 alarm management system

Upload: firas1976

Post on 06-Jul-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/16/2019 6-SGSN9810 Alarm Management System

    1/31

     

    SGSN9810 Alarm Management System

  • 8/16/2019 6-SGSN9810 Alarm Management System

    2/31

     

    Objectives

    Master SGSN9810 alarm system

    structure

    Master SGSN9810 alarm system

    principle

    Master O&M of SGSN9810 alarm

    console

    Master alarm processing flow

    • Upon completion of this course, you will e ale to! 

  • 8/16/2019 6-SGSN9810 Alarm Management System

    3/31

     

    Characteristic of Alarm Management System

    2 Control by grade

    3 simple display and query

    4 send alarm by different ways

    1 Real time

  • 8/16/2019 6-SGSN9810 Alarm Management System

    4/31

     

    Characteristic of Alarm Management System

    real time when SGSN generates alarm, alarm system will process them,

    transmit them at first, then show them through user interface,

    feed back them to operator, so operator can solve problem in

    time.control by grade

    divide alarm into four levels critical , major, minor, warning;

    process high level or more serious alarm at first.

  • 8/16/2019 6-SGSN9810 Alarm Management System

    5/31

     

    Characteristic of Alarm Management System

    simple display and uery display alarm on client alarm console; user can operate by G!"

    send alarm by different ways

    notify operator by call or sending short message when system

    generate alarm; remote maintenance is very convenient.

  • 8/16/2019 6-SGSN9810 Alarm Management System

    6/31

     

    Terms

    "# $larm SN

    1# $larm %

    '# $larm (ype

    )# $larm Se*erity

    +# *ent type

  • 8/16/2019 6-SGSN9810 Alarm Management System

    7/31

     

    Terms

     #larm "$ "n the same product, an alarm "$ specifies a certain alarm or

    event with definite alarm severity and event type. %he alarm

    name, alarm description, handling suggestions and alarm

    causes, etc. can be retrieved according to the alarm "$.

     #larm SN

     #larm SN records the seuence of the alarm generation.

     #larms share the same SN with their cleared alarms.

  • 8/16/2019 6-SGSN9810 Alarm Management System

    8/31

     

    Terms

     #larm %ype  #larm type includes &ault alarm and 'vent alarm.

    &ault alarm : &ault alarm indicates a state of a device. (ne

    value is configured for the alarm state and when the alarm is

    removed, the value of the state is also changed. !sually the

    severity of fault alarms are higher than event alarms, and fault

    alarms and their clearance alarms have a one)to)one

    correspondence relationship.

    'vent alarm : "t only indicates the system is in alarm state at

    a certain time. %here is no cleared alarm for event alarms 。

  • 8/16/2019 6-SGSN9810 Alarm Management System

    9/31

     

    Terms

     #larm Severity  #larm severity is used to indicate the severity level of an alarm,

    including *ritical alarm, +ajor alarm, +inor alarm and arning

    'vent %ype

    %he type of event with which the alarms are reported to the

    centrali-ed network center, including ten types /ower system,

    'nvironment system, Signaling system, %runk system,

    0ardware system, Software system, (perating system,

    *ommunication system, 1oS and 'rror processing.

  • 8/16/2019 6-SGSN9810 Alarm Management System

    10/31

     

    Alarm Management System Strctre

    SGSN management system includes the following

    subsystem

     #larm module

    + subsystem

    2#+ subsystem

    3+% subsystem

     #larm bo4

     #larm indicator 

  • 8/16/2019 6-SGSN9810 Alarm Management System

    11/31

     

    !ata "lo# of Alarm Management System

    Service module)))+ ))) 5fiber6))) 2#+)))network cabling)))alarm console

    Service module of every boards report alarm to +

    subsystem

    + subsystem transfers the alarm message to 2#+

    subsystem on !(+! with fiber 

    2#+ e4plains the alarm message and reports it to 3+%;

    %hen, 2#+ drives alarm bo4 and illuminates alarm

    indicators.

  • 8/16/2019 6-SGSN9810 Alarm Management System

    12/31

     

    !ata "lo# of Alarm Management System

     #pplication

    + subsystem

    2#+ subsystem

    $rive alarm

     bo4

    '4plain and process alarm;

    $ecide alarm level, type,

    generation cause and

    cleared suggestion

     #larm console

     #larm log file

    Generate alarm

    *ollect and transfer alarm

    illuminate alarm

     indicators

  • 8/16/2019 6-SGSN9810 Alarm Management System

    13/31

     

    O$M of Alarm Management System

    %here are two ways to reali-e operation and maintenance

    •  #larm management system

    • (peration 7maintenance system 

  • 8/16/2019 6-SGSN9810 Alarm Management System

    14/31

     

    O%eration an& Maintenance System

    'eali(e alarm management by o%eration$maintenance system of )*

  • 8/16/2019 6-SGSN9810 Alarm Management System

    15/31

     

    O%eration an& Maintenance System

    •  #larm parameter configuration

    • 2asic alarm operation•  #larm shielding

    •  #larm bo4 operation

  • 8/16/2019 6-SGSN9810 Alarm Management System

    16/31

     

    O%eration an& Maintenance System

     #larm /arameter *onfiguration 

    • #dd, +odify, 1uery alarm parameter 

    • 8estore alarm configuration

    • Set, 1uery alarm remarks

  • 8/16/2019 6-SGSN9810 Alarm Management System

    17/31

     

    O%eration an& Maintenance System

    2asic #larm (peration

    • 1uery alarm log

    •3ist mask alarm

    • 3ist statistics alarm

    • 3ist statistics mask alarm

    •  #cknowledge fault and event alarm

    • $elete alarm log

    • 1uery alarm details

  • 8/16/2019 6-SGSN9810 Alarm Management System

    18/31

     

    O%eration an& Maintenance System

     #larm Shielding

    • Set alarm mask

    • $elete alarm mask

    • 1uery alarm mask

  • 8/16/2019 6-SGSN9810 Alarm Management System

    19/31

     

    O%eration an& Maintenance System

     #larm 2o4 (peration

    • 8eset alarm bo4

    • Switch off alarm indicators

    • Stop alarm sound

    • Set alarm location

  • 8/16/2019 6-SGSN9810 Alarm Management System

    20/31

     

    Alarm Management System

  • 8/16/2019 6-SGSN9810 Alarm Management System

    21/31

     

    O%eration an& Maintenance System

  • 8/16/2019 6-SGSN9810 Alarm Management System

    22/31

     

    Alarm Management System

    $isplay *olor Setting

  • 8/16/2019 6-SGSN9810 Alarm Management System

    23/31

     

    Alarm Management System

  • 8/16/2019 6-SGSN9810 Alarm Management System

    24/31

     

    Alarm Management System

    1uery alarm according to the combined conditions

  • 8/16/2019 6-SGSN9810 Alarm Management System

    25/31

     

    Alarm Management System

    1uery alarm according to the combined conditions

  • 8/16/2019 6-SGSN9810 Alarm Management System

    26/31

     

    Alarm Management System

    1uery alarm according to the combined conditions

  • 8/16/2019 6-SGSN9810 Alarm Management System

    27/31

     

    Alarm Management System

    Get detailed alarm message with double)click alarm

  • 8/16/2019 6-SGSN9810 Alarm Management System

    28/31

     

    Alarm Management System

    &ault alarm notify

  • 8/16/2019 6-SGSN9810 Alarm Management System

    29/31

     

    Alarm Management System

  • 8/16/2019 6-SGSN9810 Alarm Management System

    30/31

     

    -rocess alarm

    Alarm %rocessing %roce&re

    Generate alarm

    .uery /etaile/ alarm message

    hoose alarm processing way

  • 8/16/2019 6-SGSN9810 Alarm Management System

    31/31