7528
TRANSCRIPT
8/12/2019 7528
http://slidepdf.com/reader/full/7528 1/3
Bulletin #: 7528
Date: 11/30/11
Subject: Unit Life Optimized Settings
bizhub 223: 014 bizhub 283: 014 bizhub 363: 014
bizhub 423: 014 bizhub 552: 004 bizhub 652: 004
bizhub C203: 030 bizhub C220: 052 bizhub C253: 030
bizhub C280: 052 bizhub C353: 030 bizhub C360: 052
bizhub C451: 077 bizhub C452: 088 bizhub C550: 086
bizhub C552: 098 bizhub C552DS: 036 bizhub C650: 070
bizhub C652: 098 bizhub C652DS: 036
Supersedes Bulletin #7528 dated 8/3/11. Revised to reflect current firmware versions.
Based upon feedback from the dealer community, new firmware has been released that allows suppression oftoner warning messages. The end-of-life function and stop messages for fuser units, imaging and drum units,developer and developing units, and transfer belt units can be eliminated. Replacement of these units is basedupon usage instead of counter clicks. There are several benefits to turning these settings off:
Reduced customer downtime
Elimination of emergency calls forthese units
Elimination of emergency shipping charges for spare parts
PM is scheduled on the next customer-placed call
IMPORTANT: Because the end-of-life message is eliminated, print quality is not guaranteed if the lifecounter exceeds the specification value Consequently moni toring image quality depends upon both
8/12/2019 7528
http://slidepdf.com/reader/full/7528 2/3
8/12/2019 7528
http://slidepdf.com/reader/full/7528 3/3
Group A
bizhub C650/C550/C451
bizhub C353/C253/C203
Group B
bizhub C652/C552/C452
bizhub C652DS/C552DS
bizhub 652/552
Group C
bizhub C360/C280/C220
Group D
bizhub 423/363/283/223
Not Applicable Not Applicable Not Applicable
* IU
* Drum Unit
* Developing
Unit
Press Stop->0->Clear to enter
“Enhanced Security mode”
> Life Stop Setting
Set to "No Stop"
* Transfer Belt
Unit
* Fusing Unit
> System 2
> Software Switch Setting
Switch No. : 55
Bit Assignment : bit2, bit3
Set “SW Switch Setting”
4. Eliminate Life Message Display Setting > System 2
> Software Switch Setting
Switch No. : 51
Bit Assignment :>>>>
Set “SW Switch Setting”
1. Unit Replacement & Toner Warning Settings
> System 2
> Unit Change
Set to "Service" Group A, B & C only
> Warning Display - Toner Near Empty
Set to "No"
2. IU life Extension Setting > System 1
> IU Life Stop Setting
Set to "Suspend"
3. Select No-Stop unit
Group A Group B Group C
bit3bit2
Transfer Belt UnitFusing Unit
1: No Stop 0 : Stop
1: No Display 0 : Display
One setting for all units
Suspend
No Stop No Stop No Stop
No Stop
55
00001100
XXXXX00
51
F0
0C
Please verify these settings and set if needed.
Apply "Fix" after setting has been done.
" *(asterisk) "will be indicated next to the life counter on “Machine Management List” for the unitwhose life message is set as “No Display”,.
Apply "Fix" after setting has been done.
Note: Verify bit2 is set to "0" on all machines.
Servic
User
Servic
User
Servic
User
N/A for C650/C550/C451
N/A for 652/552
User
1: No Stop 0 : Stop Notes:(*1) For Group A products, leave thesetting at "0" and do not change it.(*2) The bit No. for the IU is changed fromthe previous version (Ver. GFF-R6).