    BACKFLOW PREVENTION

    Prepared by

    Catherine L. Morley, P.E.

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    2/40

    The Surcharged Sewer Problem

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    3/40

    WHEN MIGHT IT BE NEEDED?

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    4/40

    Common Situations

    Geographical Low Point

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    5/40

    Bottom of the Hill

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    6/40

    Common Situations

    Geographical Low Point

    Influence of Pump Station Wet Well

    Sewer Lateral Connects to Interceptor

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    7/40

    Common Situations

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    8/40

    Common Situations

    Geographical Low Point

    Influence of Pump Station Wet Well

    Sewer Lateral Connects to Interceptor Downstream of Force Main Discharge

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    9/40

    Downstream of Force Main Discharge

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    10/40

    Common Situations

    Geographical Low Point

    Influence of Pump Station Wet Well

    Sewer Lateral Connects to Interceptor Downstream of Force Main Discharge

    Downstream Interceptor Exhibits Control

    Reverse Flow

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    11/40

    Downstream Control

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    0 10 20 30 40 50 60 70 80 90

    Flow(

    MGD)

    Depth of Flow (in)

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    12/40

    Common Situations

    Geographical Low Point

    Influence of Pump Station Wet Well

    Sewer Lateral Connects to Interceptor Downstream of Force Main Discharge

    Downstream Interceptor Exhibits Control

    Reverse Flow Amid Foundation Drain Clusters

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    13/40

    BACKFLOW PREVENTION OPTIONS

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    14/40

    Backflow Prevention Options

    Floor Plug

    Stand Pipe

    Backwater Valve Clean Check

    Overhead Sewer

    External Pump-Over (EverReady)

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    15/40

    Floor Plug / Stand-pipe

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    16/40

    Floor Plug / Stand-pipe

    Pros

    Cheapest options

    Easily accessible

    Cons

    Effective up to 3 head

    Need good seal with floor

    Cannot use basement facilities whileoperating

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    17/40

    Floor Plug / Stand-pipe

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    18/40

    Backwater Valve

    Internal installation shown

    Can be installed externally butneeds access chamber

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    19/40

    Backwater Valve

    Pros

    Cheapest of the valve-type options ($2,000 -$4,000)

    Easily accessible Cons

    All drains need to connect prior to be effective

    Should not be used if foundation drainconnected

    Cannot use basement facilities while operating

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    20/40

    Clean Check

    PVC THREADED PLUG

    PVC FEMALE

    ADAPTER

    PVC RISER PIPE*

    VALVE BODY

    PVC INSERT PIPE

    FLAPPER ASSEMBLY

    FLAPPER

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    21/40

    Clean Check

    Pros Relatively inexpensive ($2,500 - $6,000)

    Low maintenance

    Easily accessible

    Also a cleanout

    Cons

    Cannot be used if foundation drainconnected

    Minimal use of facilities while operating

    Roto-rooter

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    22/40

    Before Overhead Sewer Installation

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    23/40

    After Overhead Sewer Installation

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    24/40

    Overhead Sewer

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    25/40

    Overhead Sewer

    Pros

    Full protection

    May remove foundation drain from sanitary

    system

    Cons

    Expensive ($7,000 - $15,000)

    Requires battery back-up system for poweroutages

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    26/40

    External Pump-Over

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    27/40

    External Pump-Over

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    28/40

    External Pump-Over

    Pros

    Full protection

    May remove foundation drain from sanitary

    system

    Cons

    Very Expensive ($15,000 - $20,000)

    Requires auxiliary generator for poweroutages

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    29/40

    LIMITATIONS

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    30/40

    Limitations

    Maintenance Rags, check valve blockages, etc.

    Power Outages (overhead systems)

    Requires backup power supply or cannot usefacilities

    Limited Facility Use (check valve systems)

    Laundry and toilet overflows COSTS

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    31/40

    MUNICIPAL INVOLVEMENT

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    32/40

    Municipal Involvement

    Education Benefits

    Cost Sharing

    Ordinance Changes

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    33/40

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    34/40

    Overhead Sewer Conundrum

    Current Basement Backups

    Excess flow migrated upstream

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    35/40

    Benefits

    Less Complaints Less Reporting to IEPA - SSOs

    I/I Removal Through I/I Compliance

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    36/40

    Cost Sharing

    Various Plans 50/50 up to max amount

    Full cost up to a max amount

    Higher reimbursement (or %) for FD removal

    100% front with clawback

    100% for at risk properties

    Funding

    Capital allocation Sewer surcharge

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    37/40

    Ordinance Changes

    Any Backflow Prevention Building permit

    I/I compliant

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    38/40

    Foundation Drain

  • 8/10/2019 8-When All Else Fails Backflow Prevention

    39/40

    Ordinance Changes

    Any Backflow Prevention Building permit

    I/I compliant

    Cost Sharing

    Closing Ordinance Sump pump removal

    Fines for reconnection

    Teardown Policies I/I Compliance Remodeling Policies