DRAWING INDEX
C1 COVER PAGE
A1 FOUNDATION PAGE
A2 FLOOR PLAN
A3 ELECTRICAL PLAN
A4 EXTERIOR ELEVATIONS
A5 HVAC PLAN
A6 ROOF PLAN
S1 ENGINEER DETAIL PAGE
S2 ENGINEER DETAIL PAGE
A CUSTOM MODEL FOR:
GROZA BUILDERS, INC.
BUTTONWOOD KW GBI
BUTTONWOOD KEYWEST SPEC
302 SW KANE AVE
PORT ST. LUCIE, FL
8
BU
TT
ON
WO
OD
K
W G
BI
BU
TT
ON
WO
OD
K
EY
WE
ST
S
PE
C
302 S
W K
AN
E A
VE
PO
RT
S
T LU
CIE
, F
L511 SW
PO
RT SAIN
T LU
CIE BLVD
.
PO
RT ST. LU
CIE, FL 34953
P1 10/10/19
P2 10/31/19
SHINGLE
ROOF
FRONT ELEVATION
1
HARDI SIDING
DECORATIVE STUCCO FINISH
4'' RAISED STUCCO BAND
FLOAT FINISH
4'' RAISED STUCCO BAND
FLOAT FINISH
4x8 WOOD
BEAM
4x8 WOOD
BEAM
4x8 WOOD
BEAM
HARDI SIDING
DECORATIVE STUCCO FINISH
HARDI SIDING
2'WX3'H BARN DOOR
Z FACE W/ DECO HINGES
3'-0"
2'-0"
TOP OF WINDOWS TO FASCIA=11-3/16'' +/- W/2X4 END RAIL
+27.0/
+39.2/
-42.6
SCALE:
1
8
'' = 1'-0''
BIRDSEYE
CITY OF PORT ST. LUCIE BUILDING DEPARTMENT PRODUCT APPROVAL SUBMITTAL AFFIDAVIT
BUILDING PERMIT
OWNERS NAME
CONTRACTOR - GROZA BUILDERS CONTRACTOR'S ADDRESS 511 SW PORT ST LUCIE BLVD
PORT ST LUCIE FL 34953
OPENING SCHEDULE: SWING DOORS, OVERHEAD DOORS, SLIDING DOORS, FIXED GLASS, WINDOWS & SKYLIGHTS
FL= OR MIAMI-DADE PRODUCT MODEL NUMBER MANUFACTURER GLASS DESCRIPTION METHOD OF ATTACHMENT
BUILDING DESIGN
PRESSURE
PRODUCT DESIGN
PRESSURE
FL= OR MIAMI-DADE MODEL NUMBER MANUFACTURER METHOD OF ATTACHMENT
BUILDING DESIGN
PRESSURE
PRODUCT DESIGN
PRESSURE
NOTE:
ALL MANUFACTURED HOLES MUST BE FILLED WITH APPROPRIATE FASTENERS
I HAVE REVIEWED THE ABOVE COMPONANTS AND CLADDING AND HAVE APPROVED THEIR
USE IN TEH STRUCTURE TO PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND FORCES
SPECIFIED BY CURRENT CODE PROVISIONS.
NAME SIGNATURE
DATE:
DESIGN FIRM CERT. NO
FL 16177.1 IMPACT
FL 11103.1 IMPACT
20468.4
SLIDING GLASS DOOR
FIBERGLASS DOOR
SH8100 PVC SINGLE HUNG
IMPACT
8900 PVC SGD
CWS WINDOWS
CWS WINDOWS
THERMA TRU
IMPACT
LOW-E 366 INSULATED
NON-IMPACT
IMPACT
LOW-E 366 INSULATED
PLAG ANGLE TO HAVE (3)
5
16
" X 1-5/8" LAG SCREWS
AND DOOR BRACKET TO HAVE LAG SCREWS 24" O.C.
MAX AND 6" FROM CORNERS
SEE ELEVATION PAGE
SEE ELEVATION PAGE
SEE ELEVATION PAGE
+27.0/-30.0
+/- 60 PSF
MULLIONS
METAL ROOF
SIDING
SOFFIT
HURRICANE PANELS
LESS THAN 5'-7'' SPAN
HURRICANE PANELS
5'-7'' SPAN OR MORE
HARDI
FL-9520.1
CMU COMPLYING WITH ASTM C90 W/0 .14'' SHANK BY 0.300 #HD BY 1-
1
4
'' LONG ET&F BRAND STUD NAILS.
DIRECT MOUNT TO BLOCK 12" O.C.
+/- 70 PSF
16-0329.13 IKO 6 ROOFING NAILS PER TAB, CLASS F OR H
1
4
" Tapcons, 1-1/4" Min. Embed in
Head & Jamb, in all mfg. holes
1
4
" Tapcons, 1-1/4" Min. Embed in
Head & Jamb, in all mfg. holes
1
4
" T.C. at 14" O.C. 1-1/4" EMBED AT
6" FROM CORNERS
2X4 BRACE AT CENTER OF PANEL
+23.6/-28.8
+70/-61.3
SHINGLE ROOF
17-0919.12
GARAGE DOOR 16'W824/811
DAB
FL23352 Ply Gem Siding Group
SEE ELEVATION PAGE
SEE ELEVATION PAGE
WINDOWS
SINGLE HUNG
3
16
" Elco Ultracon, 1-1/4" Min. Embed in Head
& Jamb, in all mfg. holes
+/- 50 PSF
ROOF VENT
FL-21580.3
FLORIDA METAL PRODUCTS,
INC.
Apply roofing cement to the underside, back and side flanges of the roof vent. Cement should be
1
4
" thick and
extend 2" onto roof underlayment
JOB NO.
SHEET
Port Orange, Fl
www.bluestreamdesignstudio.com
(386) 256-8978
DESCRIPTION
1
2
3
4
5
6
7
8
Port Charlotte, Fl
(941) 275-9931
DATE
CHECKED BY:
DESIGN BY:
REV
Although every effort is made toensure the accuracy of theseplans it is the responsibility ofthe builder to verify alldimensions, details andspecifications shown.Bluestream Design Studio willnot be held liable for any errorsor omissions on these plans.
Design and layout or conceptsfor this design were provided toBluestream Design Studio bythe builder shown. Anysimilarities to other plans orblueprints is solely theresponsibility of the builder.Plans may not be reproduced orcopied without the expresswritten consent of the Buildershown.
SCALE:
OF
TMB
LBB
1/4" = 1'-0"
BUTTONWOOD KW GBI PERMITSET.dwg
11/7/19
C1
COVER
1
TERMITE NOTES:
1. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND
NEED FOR RE-INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE
PROVIDED.
2. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1'-0" AWAY
FROM BUILDING SIDE WALLS,
3. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL IS
COMPLETE.
4. MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST
RAINFALL DILUTION.
5. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE
WITHIN 1'-0" OF THE STRUCTURE SIDEWALLS.
6. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER
CONSTRUCTION.
7. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT
BY A LICENSED PEST CONTROL COMPANY BEFORE FINAL INSPECTION.
39'-10"
72'-0"
39'-10"
72'-0"
25'-0"
5'-8"
4'-4"
30'-4"
6'-8"
20'-0"
5'-4"
24'-0"
25'-0"
2'-2"2'-9"3'-9"
16'-8"
4'-4" 10'-2"
8"
3'-0"
8"
4'-4"
1'-4"
25'-4" 14'-6"
20'-8"
12'-4
1 2
"13'-11
1 2
"
10'-10" 18'-10"
10"3'-10"6'-0"9'-6"
8'-10"
8'-4"
16'-6"
25'-0"
9'-5"
5'-11
1 2
"14'-11
1 2
"
1
2
" X 8" Wedge Anchors @ 32" o.c. w/
2 washers & nuts
F1 CURB
F1 CURB
F1 CURB
F2
F2
F2
F3
F1
F1
F1
F1
F1
F1
F1
F2
F2
F2
FINISH FLOOR ELEVATION
0'-0''
NOTE: PROVIDE LINE FOR
ICE MAKER
8"19'-4"
2'-3"1'-7"
CRASH
POLE
SLAB NOTE
3000 PSI CONCRETE SLAB
4'' THICK W/ FIBERMESH
(OR 6''X6'' 10 /10 W.W.F.)
OVER 6 MILL VISQUEEN AND
CLEAN, COMPACTED, TERMITE
TREATED FILL
SLOPED RECESS AT GARAGE DOOR
RECESS SLAB1-1/2"
RECESS SLAB 1-1/2''
RECESS
SHOWER
TYPICAL CONCRETE SLAB
FILL TO BE TREATED FOR TERMITES BEFORE
CONCRETE SLAB
FINISH FLOOR
6 MIL POLY VAPOR BARRIER
COMPACTED FILL
POURING BUT AFTER PLUMBING ROUGH IN.
FIBER-MESH MATERIAL
OR WIRE-MESH MATERIAL
F3
F1
F1
F2
1'-4"
6'-0" 13'-10"
F1
5'-2"
3'-0"
2'-6"
F1S
8
BU
TT
ON
WO
OD
K
W G
BI
BU
TT
ON
WO
OD
K
EY
WE
ST
S
PE
C
302 S
W K
AN
E A
VE
PO
RT
S
T LU
CIE
, F
L511 SW
PO
RT SAIN
T LU
CIE BLVD
.
PO
RT ST. LU
CIE, FL 34953
P1 10/10/19
P2 10/31/19
JOB NO.
SHEET
Port Orange, Fl
www.bluestreamdesignstudio.com
(386) 256-8978
DESCRIPTION
1
2
3
4
5
6
7
8
Port Charlotte, Fl
(941) 275-9931
DATE
CHECKED BY:
DESIGN BY:
REV
Although every effort is made toensure the accuracy of theseplans it is the responsibility ofthe builder to verify alldimensions, details andspecifications shown.Bluestream Design Studio willnot be held liable for any errorsor omissions on these plans.
Design and layout or conceptsfor this design were provided toBluestream Design Studio bythe builder shown. Anysimilarities to other plans orblueprints is solely theresponsibility of the builder.Plans may not be reproduced orcopied without the expresswritten consent of the Buildershown.
SCALE:
OF
TMB
LBB
1/4" = 1'-0"
BUTTONWOOD KW GBI PERMITSET.dwg
11/7/19
A1
FOUNDTION
2
MONO EDGE FOOTER W/RECESS SHOWER
4" SHOWER
RECESS
Ducts in the garage and ducts penetrating thewalls or ceilings separating the dwelling fromthe garage shall be constructed of a minimumNo. 26 gage (0.48 mm) sheet steel, 1 inch(25.4 mm) minimum rigid nonmetallic Class0 or Class 1 duct board, or other approvedmaterial and shall not have openings into thegarage
LIVING
GARAGE
LANAI
ENTRY PORCH
TOTAL
LIVING C.F. = +/- 15,770
1,848
408
117
124
2,497
SQUARE FOOTAGE
39'-10"
25'-4" 14'-6"
9'-8" 3'-2" 12'-6" 1'-4"
72'-0"
39'-10"
72'-0"
25'-0"
10'-0"
30'-4"
6'-8"
20'-0"
2'-0" 16'-0" 2'-0"
3'-2" 3'-0"
40'-0"
4'-6"
9'-0"
3'-2"
15'-4"
15'-0"
3'-2"
6'-10"
1'-4"
8'-8"
11'-0"
2'-8"
16'-8"
8" 14'-0" 5'-0" 5'-8"
8" 6'-8" 3'-8" 3'-8" 10'-0" 8"
8"
10'-11"
2'-5"
11'-0"
10'-8
1 2
"
7'-0"
4'-3
1 2
"
4'-4"
20'-0"
8"
8"
21'-8
1 2
"
5'-8"
12'-8"
6'-0"
8"
8" 10'-2" 2'-0" 16'-2" 8" 9'-6" 8"
8"
4'-4"
8"8"
3'-8" 10'-8"
7'-0"
4'-3
1 2
"
4'-4"
20'-0"
8"
8"
18'-8" 8"4" 3'-4"
14'-0"
3'-8"
3
1 2
"
8"
6'-4"
8'-8"
3'-0"
4"
2'-3"
2'-5"
8"
2'-9
1
2
"7'-10
1
2
"
18'-4"10'-2"8"
8"
6'-11
1
2
" 12'-0
1
2
"
5'-2" 4'-4" 6'-0" 4'-0" 8"
4
'
-
6
"
1
0
"
3'-0"
8"
8'-10"4'-4"
CRASH
POLE
10'-4"8"
SIMPSON HTS20CONNECTED TOEACH TRUSS ALONGFRAMED BEARINGWALLS U.N.O
SIMPSON HTS20CONNECTED TOEACH TRUSS ALONGFRAMED BEARINGWALLS U.N.O
30"X30"
ATTIC ACCESS
FIELD LOCATE
30"X30"
ATTIC ACCESS
FIELD LOCATE
1'-4"3'-2"
1'-4" 11'-2" 1'-4"
5'-4"
1'-4"
2'-6"8"2'-4"
14'-0"
8"
19'-0" 5'-2" 14'-4" 8"
5'-4"
1'-4"
6'-0" 13'-10"
8
BU
TT
ON
WO
OD
K
W G
BI
BU
TT
ON
WO
OD
K
EY
WE
ST
S
PE
C
302 S
W K
AN
E A
VE
PO
RT
S
T LU
CIE
, F
L511 SW
PO
RT SAIN
T LU
CIE BLVD
.
PO
RT ST. LU
CIE, FL 34953
P1 10/10/19
P2 10/31/19
JOB NO.
SHEET
Port Orange, Fl
www.bluestreamdesignstudio.com
(386) 256-8978
DESCRIPTION
1
2
3
4
5
6
7
8
Port Charlotte, Fl
(941) 275-9931
DATE
CHECKED BY:
DESIGN BY:
REV
Although every effort is made toensure the accuracy of theseplans it is the responsibility ofthe builder to verify alldimensions, details andspecifications shown.Bluestream Design Studio willnot be held liable for any errorsor omissions on these plans.
Design and layout or conceptsfor this design were provided toBluestream Design Studio bythe builder shown. Anysimilarities to other plans orblueprints is solely theresponsibility of the builder.Plans may not be reproduced orcopied without the expresswritten consent of the Buildershown.
SCALE:
OF
TMB
LBB
1/4" = 1'-0"
BUTTONWOOD KW GBI PERMITSET.dwg
11/7/19
A2
FLOOR PLAN
3
SIZE SERVICE 200 AMPS
CONDUCTOR SIZE 2/0 CU
METER CAN ONLY
CONST. TYPE RESIDENTIAL
#4 Bare copper
to steel of footer
with one ground
rod 6’ away
200 AMP OVERHEAD
ELECTRIC SERVICE
1. ELECTRICAL CONTRACTOR TO VERIFY SERVICE REQUIREMENTS
2. 200 AMP SERVICE
3. ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY W/
APPLICABLE PROVISIONS OF THE NATIONAL ELEC. CODE, LOCAL
CODES, AND THE LOCAL POWER CO.
4. SMOKE DETECTORS ARE REQUIRED
5. CARBON MONOKIDE DETECTORS AS REQUIRED
6. FIELD VERIFY RECEPTACLE LOCATIONS
7. ALL RECEPTACLES NOT REQ'D. TO BE GFI SHALL BE ARC FAULT
PROTECTED PER NEC 210.12
8. ALL RECEPTACLES TO BE TAMPERPROOF WHERE REQ'D. BY NEC
406.11 ARC-FAULT CIRCUIT INTERRUPTER SHALL BE INSTALLED
IN A READILY ACCESSIBLE LOCATION
9. RECESSED LIGHTING FIXTURES MUST COMPLY WITH FLORIDA
ENERGY CODE 606.1.ABC. 1.2.4, PRODUCT APPROVAL (TOTALY
ENCLOSED)
10. DISHWASHER OUTLET TO BE UNDER SINK FOR ACCESS
11. EXHAUST IN BATHROOMS EXHAUSTED DIRECTLY TO OUTDOORS
12. WIRE FOR GARBAGE DISPOSAL WITH SWITCHED OUTLET
13. KITCHEN OUTLETS TO BE GFI
14. FIELD VERIFY WELL PUMP AND AC EQUIPMENT LOCATIONS
15. ALL LIGHTING FIXTURES, RECEPTACLES AND LIGHT SWITCHES
MUST COMPLY WITH ART. 410 OF NEC
16. W/P GFI OUTLET WITHIN 25' OF AC COMPRESSOR
17. WIRE FOR GARAGE DOOR OPENER
18. ALL SWITCHES WITH DECORA ROCKER
19. WIRE FOR VENTLESS MICROWAVE, OUTLET IN CABINET ABOVE
MUST BE HOME RUN
20. IF NEC, PREWIRE FOR MIN SEWER ALARM BOX OR DOZER SEPTIC
SYSTEM (FIELD VERIFY)
21. ALL SMOKE DETECTORS MUST BE A MINIMUM OF 3' FROM ANY
BATHROOM DOOR
22. ARC FAULT PROTECTION TO BE USED IN ALL BEDROOMS
23. ELECTRICIAN TO SUPPLY ALL SMOKE DETECTORS AND DOOR BELL
CHIMES
24. ALL CHANGES MUST BE DONE IN WRITING BY GROZA BUILDERS,
INC. HOME OWNERS DO NOT HAVE THE RIGHT TO CREATE
CHANGES WITHOUT DOCUMENTS
CRASH
POLE
30"X30"
ATTIC ACCESS
FIELD LOCATE
30"X30"
ATTIC ACCESS
FIELD LOCATE
8
BU
TT
ON
WO
OD
K
W G
BI
BU
TT
ON
WO
OD
K
EY
WE
ST
S
PE
C
302 S
W K
AN
E A
VE
PO
RT
S
T LU
CIE
, F
L
511 SW
PO
RT SAIN
T LU
CIE BLVD
.
PO
RT ST. LU
CIE, FL 34953
P1 10/10/19
P2 10/31/19
JOB NO.
SHEET
Port Orange, Fl
www.bluestreamdesignstudio.com
(386) 256-8978
DESCRIPTION
1
2
3
4
5
6
7
8
Port Charlotte, Fl
(941) 275-9931
DATE
CHECKED BY:
DESIGN BY:
REV
Although every effort is made toensure the accuracy of theseplans it is the responsibility ofthe builder to verify alldimensions, details andspecifications shown.Bluestream Design Studio willnot be held liable for any errorsor omissions on these plans.
Design and layout or conceptsfor this design were provided toBluestream Design Studio bythe builder shown. Anysimilarities to other plans orblueprints is solely theresponsibility of the builder.Plans may not be reproduced orcopied without the expresswritten consent of the Buildershown.
SCALE:
OF
TMB
LBB
1/4" = 1'-0"
BUTTONWOOD KW GBI PERMITSET.dwg
11/7/19
A3
ELECTRICAL
4
REAR ELEVATION
SCALE:
1
4
'' = 1'-0''
DECORATIVE
STUCCO FIINISH
SHINGLE
ROOF
ROOF VENT ROOF VENT
FLORIDA BUILDING CODE RESIDENTIAL 2017 6TH EDITION
BASIC WIND SPEED: 170 MPH
RISK CATEGORY: II
NOMINAL WIND SPEED (vasd): 132 MPH
FLOOD ZONE: ZONE X
INTERNAL PRESSURE COEFFICEINT: +/-0.18
EXPOSURE CATEGORY: C
STRUCTURAL FORCES:
FLOOR LIVE LOAD: 40 PSF
ROOF LIVE LOAD: 30 PSF
FLOOR DEAD LOAD: 30 PSF
ROOF DEAD LOAD 25 PSF
ROOF SLOPE: 5/12
COMPONENTS AND CLADDING DESIGN PRESSURES
ZONE 1: +23.3/-37.0
ZONE 2: +23.3/-64.4
ZONE 3: +23.3/-95.2
ZONE 4: +40.3/-43.7
ZONE 5: +40.3/-54.0
WINDOWS AND DOOR WIND PRESSURE DESIGN LOADING
WINDOWS: +40.3/-43.7
DOORS: +38.9/-42.3
GARAGE DOOR: +27/-32
MEAN ROOF HEIGHT: 12 FEET
SHINGLE
ROOF
FRONT ELEVATION
SCALE:
1
4
'' = 1'-0''
HARDI SIDING
DECORATIVE STUCCO FINISH
4'' RAISED STUCCO BAND
FLOAT FINISH
4'' RAISED STUCCO BAND
FLOAT FINISH
4x8 WOOD
BEAM
4x8 WOOD
BEAM
4x8 WOOD
BEAM
LEFT ELEVATION
SCALE:
1
4
'' = 1'-0''
DECORATIVE
STUCCO FIINISH
RIGHT ELEVATION
SCALE:
1
4
'' = 1'-0''
DECORATIVE
STUCCO FIINISH
SHINGLE
ROOF
ROOF VENT
ROOF VENT
SHINGLE
ROOF
ROOF VENT
ROOF VENT
HARDI SIDING
DECORATIVE STUCCO FINISH
HARDI SIDING
2'WX3'H BARN DOOR
Z FACE W/ DECO HINGES
3'-0"
2'-0"
TOP OF WINDOWS TO FASCIA=11-3/16'' +/- W/2X4 END RAIL
TOP OF WINDOWS TO FASCIA=11-3/16'' +/- W/2X4 END RAIL
TOP OF WINDOWS TO FASCIA=11-3/16'' +/- W/2X4 END RAIL
TOP OF WINDOWS TO FASCIA=11-3/16'' +/- W/2X4 END RAIL
+38.5/
-41.9
+27.0/
-30.0
+39.2/
-42.6
+39.2/
-42.6
+39.2/
-42.6
+38.2/
-41.7
+38.2/
-41.7
+39.2/
-42.6
+38.9/
-42.3
+38.2/
-41.7
+39.2/
-42.6
+40.3/
-43.7
8
BU
TT
ON
WO
OD
K
W G
BI
BU
TT
ON
WO
OD
K
EY
WE
ST
S
PE
C
302 S
W K
AN
E A
VE
PO
RT
S
T LU
CIE
, F
L511 SW
PO
RT SAIN
T LU
CIE BLVD
.
PO
RT ST. LU
CIE, FL 34953
P1 10/10/19
P2 10/31/19
JOB NO.
SHEET
Port Orange, Fl
www.bluestreamdesignstudio.com
(386) 256-8978
DESCRIPTION
1
2
3
4
5
6
7
8
Port Charlotte, Fl
(941) 275-9931
DATE
CHECKED BY:
DESIGN BY:
REV
Although every effort is made toensure the accuracy of theseplans it is the responsibility ofthe builder to verify alldimensions, details andspecifications shown.Bluestream Design Studio willnot be held liable for any errorsor omissions on these plans.
Design and layout or conceptsfor this design were provided toBluestream Design Studio bythe builder shown. Anysimilarities to other plans orblueprints is solely theresponsibility of the builder.Plans may not be reproduced orcopied without the expresswritten consent of the Buildershown.
SCALE:
OF
TMB
LBB
1/4" = 1'-0"
BUTTONWOOD KW GBI PERMITSET.dwg
11/7/19
A4
ELEVATION
5
ROOF SHEETING
ATTACHMENT DETAIL
1. MINIMUM NAIL SIZE = 8d RING SHANK (MIN. 2'' LONG)
2. MINIMUM SCREW SIZE = #8 X 2''
3. MINIMUM SHEATHING THICKNESS 5/8'' CDX PLYWOOD
4. USE NAILS OR SCREWS BASED ON PRESSURE FOR ROOF
STATED IN PERMIT INFO BOX ON THESE PLANS FOR ZONE 3
Hatch Legend
8'-1" A.F.F
C06
C05
C04
C03
C02
C01
A01
A02
B07
B06
B05
H
J
7
H
J
7
EJ7
EJ7
EJ7
CJ1
CJ3
CJ5
CJ1
CJ3
CJ5
EJ7
EJ7
EJ7
CJ1
CJ3
CJ5
CJ1
CJ3
CJ5
EJ7
B04
B04
B04
B04
B04
B04
B03
B02
B01
A11
A10
D02
D01
A09
A08
A07
A06
A05
A04
A03
H
J
6
CJ1
CJ3
CJ5
CJ1
CJ3
CJ5
EJ6
EJ6
EJ61
EJ62
C09
C08
C08
C08
C07
D08
H
J
5
H
J
5
EJ5
CJ1
CJ3
CJ1
CJ3
EJ5
CJ1
CJ3
CJ1
CJ3
EJ5
D07
D06
D05
D04
D03
EJ63
H
J
4
CJ2
CJ41
CJ21
CJ42
EJ4
EJ41
V01
V03
V04
V05
V02
LUS26
LUS26
LUS26
DRYERVENT
ATTIC AHUSTORAGE
2/12 VAULT >>>
<<<2/12 VAULT
<<< 2/12 VAULT
2/12 VAULT >>>
8'-1" CLNG
8'-1" CLNG
8'-1" CLNG
8'-1" TO 8'-9"COFFER (+8" CLNG)
8'-1" BRG WALL
8'-1" BRG WALL
8'-1" TO 8'-9"COFFER (+8" CLNG)
INVERTED CLNG
INVERTED CLNG
INVERTED CLNG
INVERTED CLNG
1'-0"
HEEL HEIGHT
5
TRUSS END DETAIL
PLUMB CUT OVERHANG
12
4-1/2"
TOP OF HEEL @ 10'-1" HELD BACK 1"
72' 0"
6' 8"
30' 4"
10' 0"
25' 0"
72' 0"
20' 0" 6' 0" 13' 10"
39' 10"
25' 4" 14' 6"
39' 10"
4' 4"
10' 2"4' 4"
5' 8"
1' 4"
1' 10 1/2"
11' 0"
7' 0"
16' 0"
14' 0"
21' 8"
28' 2"
5' 10 1/2"
14' 4"
3' 4"
5' 0"
20' 0"
1' 0"
26' 0"
2' 0"
13' 0 1/2"
1-HETA20
1-HETA20
1-HETA20
1-HETA20
1-HETA20
1-HETA20
1-HTS20
1-HTS20
1-HETA20
Max Uplift All uplift 100 lb or less at joint(s) except 2=-395(LC 12),
17=-283(LC 9), 12=-358(LC 13), 9=-355(LC 13
Max Uplift 2=-359(LC 12), 11=-401(LC 13), 19=-526(LC 8
Max Uplift 2=-303(LC 12), 16=-684(LC 12), 12=-389(LC 13
Max Uplift 2=-660(LC 12), 12=-660(LC 13
Max Uplift 2=-642(LC 12), 12=-642(LC 13
Max Uplift 2=-621(LC 12), 11=-621(LC 13
Max Uplift 2=-609(LC 8), 10=-609(LC 9
Max Uplift 2=-638(LC 8), 10=-638(LC 9
Max Uplift 2=-374(LC 8), 14=-1080(LC 8), 11=-578(LC 23
Max Uplift 2=-387(LC 12), 14=-1043(LC 13), 11=-311(LC 23
Max Uplift 2=-406(LC 27), 14=-1257(LC 9), 11=-325(LC 13
Max Uplift 2=-461(LC 12), 15=-443(LC 13
Max Uplift 2=-440(LC 12), 15=-398(LC 13
Max Uplift 6=-385(LC 13), 2=-434(LC 12
Max Uplift 2=-434(LC 12), 6=-434(LC 13
Max Uplift 2=-434(LC 12), 6=-434(LC 13
Max Uplift 2=-434(LC 12), 6=-434(LC 13
Max Uplift 2=-434(LC 12), 6=-434(LC 13
Max Uplift 2=-434(LC 12), 6=-434(LC 13
Max Uplift 2=-434(LC 12), 6=-434(LC 13
Max Uplift 2=-418(LC 12), 7=-418(LC 13
Max Uplift 2=-411(LC 8), 7=-411(LC 9
Max Uplift 2=-999(LC 4), 6=-999(LC 5
Max Uplift 2=-136(LC 12), 15=-78(LC 12), 21=-132(LC 9
Max Uplift 2=-146(LC 12), 14=-61(LC 12), 19=-135(LC 9
Max Uplift 2=-159(LC 12), 14=-53(LC 12), 21=-124(LC 13
Max Uplift 2=-159(LC 12), 14=-54(LC 12), 19=-124(LC 13
Max Uplift 2=-164(LC 12), 13=-211(LC 9), 18=-38(LC 12
Max Uplift 2=-337(LC 36), 27=-513(LC 8), 21=-390(LC 5
Max Uplift 8=-254(LC 13), 2=-307(LC 12
Max Uplift 2=-307(LC 12), 8=-307(LC 13
Max Uplift 2=-307(LC 12), 8=-307(LC 13
Max Uplift 2=-307(LC 12), 8=-307(LC 13
Max Uplift All uplift 100 lb or less at joint(s) 17, 13, 2 except 10=-101(LC 9), 16=-108(LC
12), 18=-184(LC 12),
14=-107(LC 13), 12=-183(LC 13
MMax Uplift 6=-288(LC 12), 2=-268(LC 12
Max Uplift 7=-252(LC 9), 2=-275(LC 12
Max Uplift 6=-261(LC 9), 2=-273(LC 12
Max Uplift 7=-585(LC 5), 2=-331(LC 4
Max Uplift 2=-242(LC 12), 11=-201(LC 13
Max Uplift 6=-195(LC 13), 2=-246(LC 12
Max Uplift All uplift 100 lb or less at joint(s) except 5=-223(LC 13), 2=-202(LC
8), 6=-118(LC 12
Max Uplift 2=-434(LC 8), 6=-438(LC 9
Max Uplift 3=-11(LC 1), 2=-109(LC 8
Max Uplift 3=-66(LC 12), 2=-116(LC 8
Max Uplift 3=-129(LC 12), 2=-122(LC 8
Max Uplift 3=-66(LC 12), 2=-116(LC 8
Max Uplift 3=-11(LC 1), 2=-109(LC 8
Max Uplift 3=-129(LC 12), 2=-122(LC 8
Max Uplift 3=-66(LC 12), 2=-116(LC 8
Max Uplift 3=-11(LC 1), 2=-109(LC 8
Max Uplift 3=-11(LC 1), 2=-109(LC 8
Max Uplift 3=-66(LC 12), 2=-116(LC 8
Max Uplift 3=-129(LC 12),
2=-122(LC 8
Max Uplift 3=-155(LC 12),
2=-127(LC 8
Max Uplift 3=-163(LC 12), 2=-139(LC 12
8
BU
TT
ON
WO
OD
K
W G
BI
BU
TT
ON
WO
OD
K
EY
WE
ST
S
PE
C
302 S
W K
AN
E A
VE
PO
RT
S
T LU
CIE
, F
L511 SW
PO
RT SAIN
T LU
CIE BLVD
.
PO
RT ST. LU
CIE, FL 34953
P1 10/10/19
P2 10/31/19
JOB NO.
SHEET
Port Orange, Fl
www.bluestreamdesignstudio.com
(386) 256-8978
DESCRIPTION
1
2
3
4
5
6
7
8
Port Charlotte, Fl
(941) 275-9931
DATE
CHECKED BY:
DESIGN BY:
REV
Although every effort is made toensure the accuracy of theseplans it is the responsibility ofthe builder to verify alldimensions, details andspecifications shown.Bluestream Design Studio willnot be held liable for any errorsor omissions on these plans.
Design and layout or conceptsfor this design were provided toBluestream Design Studio bythe builder shown. Anysimilarities to other plans orblueprints is solely theresponsibility of the builder.Plans may not be reproduced orcopied without the expresswritten consent of the Buildershown.
SCALE:
OF
TMB
LBB
1/4" = 1'-0"
BUTTONWOOD KW GBI PERMITSET.dwg
11/7/19
A6
ROOF PLAN
6
FOOTING AT CORNER
CHRISTOPHER D. BEERS, P.E.
FLORIDA LICENSE NO. 64594
5109 Grand Palmetto Way
North Port, Florida 34291-8049
941-628-0635
fax 413-487-9013
BEAM CORNER DETAIL
MASONRY TO FRAME BEARING WALL CONNECTION
1/2'' X 8'' WEDGE ANCHORS @ 32'' O.C.
HURRICANE TIE AT EACH TRUSS
PROVIDE SIMPSON HTS20
GENERAL NOTES:
TRUSS CONNECTOR NOTES:
1. PROVIDE SIMPSON (1)HETA 20 HURRICANE STRAP
AT EACH TRUSS TO TIE-BEAM CONNECTION,
UNLESS NOTED OTHERWISE.
TYPICAL WALL SECTION
WINDOW
8"x8"x16" CONC. BLOCK
WOOD BASE
varies see plan
BLOCK FILLED INJECTED
KNEEWALL DETAIL
FOAM INSULATION R-9
W/ (2) WASHERS & NUTS
TO WALL WITH "F" CHANNEL
USING "T-NAILS" AT 16" O.C. (MIN.
(I.E., 4d ROOFING COIL NAILS)
AND BATTEN WITH O.12" DIAMETER,
1-1/2" LONG, SMOOTH SHANK NAILS
5/8" LENGTH) AND TO FASCIA BOARD
AT 12" O.C.
FLOOR LINE
GRADE SHALL BE
~4" BELOW FINISH
CEMENTIOUS
DECORATIVE
COATING
16"W X 16"H CONC. FOOTING
(OR AS NOTED ON FND. PLAN)
W/(2) #5 BARS CONT.
CONC. STD. 90° HOOK TOP & BOTTOM
MIN. 25" LAP. PROVIDE INSPECTION
1x2 P.T. WD. FURRING
1/2" DRYWALL OVER
PROCTOR MAXIMUM DRY DENSITY
OF 95% OF THE MODIFIED
COMPACTED TO A MINIMUM
FILL MUST BE CLEAN AND
HOLES.
OVERHANG DOES NOT REQUIRE
BATONS IF 12" OR LESS
BE AS DESIGNATED ON PLANS
ALL STRAPS TO TRUSSES SHALL
HURRICANE STRAP @ EA. TRUSS;
ATTACH WITH ROOF NAILS
AT 12" O.C.; STAGGER WITH
ALUMINUM DRIP EDGE
2x4 END RAIL; ATTACH
(2) 12d, FACE NAILED
2x4 TO TRUSSES WITH
ATTACH FASCIA WITH ROOF
ALUMINUM FASCIA OVER
NAILS AT 12" O.C.; STAGGER
VINYL SOFFIT- ATTACH
PREFINISHED PERFORATED
26 GAUGE (MIN.)
DRIP EDGE NAILS
26 GAUGE (MIN.)
FASCIA NAILS
COMPOSITE SHINGLES ON #30 FELT OVER
1/2'' CDX (MIN) - SHEATHING W/8d
THROUGHOUT
RINGSHANK NAILS AT 6" O.C.
5/8" DRYWALL OR
INSULATION R-30
OR PER ENERGY CALC'S
1/2" CD. BOARD CLG.
UNLESS NOTED. FILLED W/ 3000 PSI
FOR LOCATIONS. 1- #5 RE-BAR TYP.
VERTICAL REINFORCING - SEE PLAN
WITH GALV. BEARING PLATES
PRE-ENGINEERED WOOD TRUSSES
INTERMEDIATE BATTENS ARE
IF OVERHANG EXCEEDS 24"
REQUIRED 12" O.C.
SINGLE 8" U-BLOCK WITH (1)
#5 RE-BAR TOP CONTINUOUS
IN EACH U-BLOCK
WELL COMPACTED EARTH
JOINTS, OVER TERMITE TREATED,
BARRIER W/ TAPED & LAPPED
ON A 6 MIL VISQUEEN VAPOR
FIBERMESH OR 6X6X10/10 WWM
4" CONC. SLAB, 3000 PSI, W/
16"
16"
(1) COURSE 9'' BLK
12" OVERHANG
BAFFLE/VENT
EXT. SWING DOOR
ATTACHMENT DETAIL
1X2 P.T. FURRING
1X8 P.T. DOOR BUCK
ATTACHED W/ 1-1/2'' "T" NAILS
@ 4'' FROM EACH END AND
18'' O.C. (SINGLE LEAF) &
12'' O.C. (DBL LEAF)
BRICK MOLDINGS
TYP. STUCCO
1/2'' DRYWALL
FILLED BLOCK 1#5
FOIL
HINGED SWING DOOR
DOOR JAMB ATTACHED W/ 1/4'' X 3-1/2'' TAPCONS
@ 6'' EACH END & 18'' O.C. (SINGLE LEAF) &
12'' O.C. (DBL LEAF)
CASING
1X2 P.T. FURRING
1X2 P.T. FURRING
1X6 P.T. DOOR BUCK
ATTACHED W/ 1-1/2'' "T" NAILS
@ 18'' O.C. VERT
DOOR FRAME
ATTACH TO CONC. BLOCK
THROUGH WOOD DOOR
BUCK W/ 3/16'' X 2-3/4'' TAPCONS.
FILL ALL HOLES. 1-1/4'' MIN EMBEDMENT
TYP. STUCCO
S.G.D. ATTACHMENT DETAIL
1/2'' DRYWALL
1X2 P.T. FURRING
1X2 P.T. FURRING
1X4 P.T. WINDOW BUCK
ATTACHED W/ 1-1/2'' "T" NAILS
@ 18'' O.C. VERT
WINDOW FRAME
ATTACH TO CONC. BLOCK
THROUGH WOOD WINDOW
BUCK W/ 3/16'' X 2-3/4'' TAPCONS.
FILL ALL HOLES. 1-1/4'' MIN EMBEDMENT
TYP. STUCCO
WINDOW ATTACHMENT DETAIL
1/2'' DRYWALL
CONCRETE FOOTER
2X BLOCKING
AS REQUIRED
BY FLORIDA
BUILDING CODE
RESIDENTIAL
STUD ALONG BLOCK
WALL TO BE P.T.
TAPCON SCREWS #10 X 3''
@ 16'' O.C. OR 1/2'' DIM. X
5-1/2'' LG. REDHEADS W/
2'' DIM. X 1/8'' WASHER
STRAP DBL TOP PLATE TO
EA. STUD USING SIMPSON SP
STRAPS. ADJUST THE STRAP SIZE
TO MATCH STUD WIDTH.
2X STUDS
SEE WALL SECTIONS
FOR APPLICABLE WIDTHS
AND STUD SPACING
CONTRACTOR TO FILL LAST
CELL SOLID WITH CONCRETE AND
(1) #5 BAR VERT. FOR FRAME WALL
ATTACHMENT
BEAM - SEE TYPICAL SECTION
AT BLOCK WALL
NO
MIN
AL
8"X 16" C.M.U. DETAIL
CONCRETE FILLED CELL
8"x16" CMU
NOMINAL
VERTICAL #5
REBAR (TYP.)
16"
8"
ACCOMMODATE BRACKETS. ATTACH
USE 2x8 PRESSURE TREATED WOOD BUCK
GARAGE DOOR SPRING BUCK INSTALLATION
2X6 BLOCKING FOR
LENGTH OF 4"
INTO CMU; MIN.
THRU 2X BLOCK
1/4" TAPCON
WITH 3" WASHERS STARTING AT 8" FROM EACH END
INSTALLATION DETAIL
TYPICAL GARAGE DOOR BUCK AND VERTICAL TRACK
USE 2x6 PRESSURE TREATED WOOD BUCKS ATTACHED
GARAGE DOOR BUCK INSTALLATION
GARAGE OVERHEAD DOOR CONNECTION
ONE 1/2" x 1-5/8" LAG
SCREW PER TRACK BRACKET
2x6 P.T. S.Y.P. BUCK
AS PER MANUFACTURER
12 GA. GALV. STEEL VERTICAL TRACK
WEDGE ANCHOR
N.T.S.
JAMB
TWO (MIN.)
MOUNTING
SPRING
BRACKET FOR
BRACKETS
BRACKET FOR
MOUNTING
GLIDE ROD
2x6 PT with 1/2” x 7” wedge anchors with square washers
AND SPACED NO MORE THAN 32" o.c.
WITH A MINIMUM OF FOUR 1/2" ø WEDGE ANCHORS
OF SUFFICIENT HEIGHT TO
CONCRETE NAILS AT 4" O.C.
WOOD BEAM TO
CBS WALL ATTACHMENT
CBS WALL
(4) SIMPSON STRAP
LSTA15 FASTENED W/
(12) 10d NAILS EACH
DBL 2'' X 12'' WOOD BEAM
4''X4'' WOOD
POST CENTERED
ON CBS WALL
POST CONNECTED TO CBS
WALL W/ SIMPSON ABU44
FASTENED W/ 1/2'' X 6'' TITEN HD
AND (12) 6d NAILS INTO POST
SIMPSON SP4 OR SP1
OR USP TP4X FROM
STUD TO BOT. PLATE
1/2"x8' WEDGE ANCHOR
AT 32" O.C.
8" CMU WALL
LINTEL
2x4 P.T.
CLIP EACH TRUSS
(SEE FLOOR PLAN FOR TYPE)
FRAME OUT TO
BLOCK EDGE
STUD ANCHORING:
STUD TO TOP PLATE,
SIMPSON SP4 OR SP2
2x4 SYP @ 16" O.C. TO 48" HIGH
2x6 SYP @16" O.C. 48" TO
72" IN HEIGHT
COMMONS @ 6" ON
EDGES & 12" IN
FIELD
7/16" OSB W/8d
ENTRY CMU COLUMN/HEADER
FOR BEAM SPEC.
SIMPSON HETA18
EACH END OF
EACH BEAM
SEE FLOOR PLAN
CONTINUOUS BOTTOM CHORD BRACING
CROSS BRACING DETAIL (TYP.)
2x4 MINIMUM
PER JOINT
(3) 12d NAILS
(SEE PLAN FOR
CROSS BRACING
MINIMUM 2x4
LOCATIONS)
10d AT 4" O.C. BOTH SIDES
HEADER AT RAISED ENTRY/CMU WALL
TYPICAL BLOCK
USE (2) SIMPSON MSTAM24
WITH (9) 10d AND (5)
1/4"x2-1/4" TITENS
ALTERNATE HOLDOWN:
WALL
TIE BEAM
W/(10) 16d EACH TO
POST
(2) SIMPSON HETA18's
BUILT-UP 2x4's OR
4x4 POST
BEAM - SEE FLOOR
PLAN FOR SPECS
OF 2x4 TO BEAM
SUPPORT COLUMN
(4) 10d EACH SIDE
R703.4 Flashing.
Approved corrosion-resistant flashing shall be applied shingle-fashion in a manner to prevent entry of water
into the wall cavity or penetration of water to the building structural framing components. Self-adhered
membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at
the juncture with the building wall with a sealant complying with AAMA 800 or ASTM C 920 Class 25 Grade
NS or greater for proper joint expansion and contraction, ASTM C 1281, AAMA 812, or other approved
standard as appropriate for the type of sealant. The flashing shall extend to the surface of the exterior wall
finish. Approved corrosion-resistant flashings must be installed. Sher-Crete flexible concrete waterproofer or
equal.
5/8 " thick stucco(horizontal application)and 7/8" thick stucco (vertical application)3/8" hi-rip lath wood framing with nails orstaples to provide no less than 1-3/4”penetration into horizontal wood framingand 3/4” penetration into vertical woodframing members
8
BU
TT
ON
WO
OD
K
W G
BI
BU
TT
ON
WO
OD
K
EY
WE
ST
S
PE
C
302 S
W K
AN
E A
VE
PO
RT
S
T LU
CIE
, F
L511 SW
PO
RT SAIN
T LU
CIE BLVD
.
PO
RT ST. LU
CIE, FL 34953
P1 10/10/19
P2 10/31/19
JOB NO.
SHEET
Port Orange, Fl
www.bluestreamdesignstudio.com
(386) 256-8978
DESCRIPTION
1
2
3
4
5
6
7
8
Port Charlotte, Fl
(941) 275-9931
DATE
CHECKED BY:
DESIGN BY:
REV
Although every effort is made toensure the accuracy of theseplans it is the responsibility ofthe builder to verify alldimensions, details andspecifications shown.Bluestream Design Studio willnot be held liable for any errorsor omissions on these plans.
Design and layout or conceptsfor this design were provided toBluestream Design Studio bythe builder shown. Anysimilarities to other plans orblueprints is solely theresponsibility of the builder.Plans may not be reproduced orcopied without the expresswritten consent of the Buildershown.
SCALE:
OF
TMB
LBB
Custom
BUTTONWOOD KW GBI PERMITSET.dwg
11/7/19
S1
STRUCTURAL
9
CHRISTOPHER D. BEERS, P.E.
FLORIDA LICENSE NO. 64594
941-628-0635
fax 413-487-9013
NOTE: NON BEARING WALL DETAIL IS IN
ACCORDANCE WITH 602.2 OF THE
FLORIDA BUILDING CODE 6TH EDITION
CONCRETE FOOTER
2X BLOCKING
AS REQUIRED
BY FLORIDA
BUILDING CODE
RESIDENTIAL
2X4 STUDS
SEE WALL SECTIONS
FOR APPLICABLE WIDTHS
AND STUD SPACING
@ 24" O.C.
NON- BEARING WALL CONNECTION
PRE-MANUFACTURED
TRUSSES
FRAME BRG. WALL W/ OPENING
(2)2x12 HEADER OR AS
NOTED ON THE PLANS
TYPICAL CONNECTOR DETAIL
CONCRETE FOUNDATION
AS NOTED ON PLANS
(1) SIMPSON "SPH4"
PER STUD. NOTE: (2)
JACK STUDS & (1)
KING STUD (MIN)
1/2" Ø WEDGE ANCHORS, 8"
DEPTH WITHIN 6" OF STUDS; & 32'' O.C.
FOR REMAINING WALL
W/3" HOOK AND 3" Ø
WASHERS. NOTE: ALTERNATIVE
HOLDDOWN IS SIMPSON "HTT4"
ATTACHED TO STUDS.
(2) SIMPSON "LSTA21"
STRAPS PER SIDE PER
HEADER
CONNECT TRUSSES TO LOAD BEAR
WALL AS NOTED ON THE PLANS.
NOTE:
BEARING WALLS THAT GO
INTO BLOCK WALLS ATTACH
WITH WEDGE ANCHORS 32'' O.C.
VERTICALLY UP WALL
2X12 HEADER NOTE:
(2)2X12 TO SANDWICH
(1) 1/2" PLYWOOD W/
(2) ROWS OF 3" NAILS @
6" O.C.
5/8 " thick stucco(horizontal application)and 7/8" thick stucco (vertical application)3/8" hi-rip lath wood framing with nails orstaples to provide no less than 1-3/4”penetration into horizontal wood framingand 3/4” penetration into vertical woodframing members
5109 Grand Palmetto Way
North Port, Florida 34291-8049
BEAM PER PLAN
FOOTER PER PLAN
8'-0"
13'-10"
1'-4" 11'-2" 1'-4"
FRONT PORCH DETAIL
BEAM PER PLAN
FOOTER PER PLAN
10'-0"
9'-4"
1'-4" 6-0" 2'-0"
ENTRY DETAIL
CONVENTIONAL GABLE END CONNECTION DETAIL
BRACING - DO NOT TOE NAIL
H4 CONNECTOR AT ALL ENDS OF CROSS
USE USP HCLH (or L) OR SIMPSON
2x4 "T-BACK" BRACING
AT VERTICALS TALLER
12" OVERHANG) OTHERWISE TOE NAIL W/TWO 10d NAILS
2x4 BLOCKS @ 16" O.C. FASTEN TO LO0KOUT W/TWO
10d NAILS AND CLIP WITH HCLH OR H4 (IF MORE THAN
10d NAILS @ 6" O.C.
8'-0" BETWEEN TRUSS
2x4 BLOCKING @ 48"o.c.
FROM GABLE END BACK
1/2"ø x 8" ANCHOR BOLT AT
3/16"ø TAPCONS WITH 1" MINIMUM
3' O.C. w/ 2"ø WASHERS, OR,
2x6 P.T. (MIN.) ATTACH TO BEAM W/
THAN 48", FASTEN W/
GABLE END TRUSS
10d NAILS @ 6" O.C.
INTO 2x6 PLATE
TOP CONTINUOUS
WITH (1) #5 RE-BAR
8" U-BLOCK WITH
SEE PLAN
VERT. REINF.
EMBEDMENT AT 12" O.C.
8" CMU WALL
6" EMBEDMENT
BOTTOM CHORDS.
UP TO 2' O.H.
POINT REGARDLESS OF HEIGHT
2x4 LOOKOUTS
24" O.C. (TYP.)
EXTEND BACK 3 BAYS
HEIGHT IS 3' OR MORE;
AND AT QUARTER POINTS IF
"X" BRACING (2x4) @ MID
TO GABLE TOP CHORD
1/2" DRYWALL
H4 CONNECTOR AT ALL ENDS OF CROSS
USE USP HCLH (or L) OR SIMPSON
BRACING - DO NOT TOE NAIL
TEXTURED CEMENT FINISH
ON METAL LATH & FELT
OR TYVEK & 1/2" PLYWOOD
W/ NAIL PRO 2x.075 @ 6" O.C.
SEE ELEVATION
PER ASTM C1063
HARDI SIDING OR
8
BU
TT
ON
WO
OD
K
W G
BI
BU
TT
ON
WO
OD
K
EY
WE
ST
S
PE
C
302 S
W K
AN
E A
VE
PO
RT
S
T LU
CIE
, F
L511 SW
PO
RT SAIN
T LU
CIE BLVD
.
PO
RT ST. LU
CIE, FL 34953
P1 10/10/19
P2 10/31/19
JOB NO.
SHEET
Port Orange, Fl
www.bluestreamdesignstudio.com
(386) 256-8978
DESCRIPTION
1
2
3
4
5
6
7
8
Port Charlotte, Fl
(941) 275-9931
DATE
CHECKED BY:
DESIGN BY:
REV
Although every effort is made toensure the accuracy of theseplans it is the responsibility ofthe builder to verify alldimensions, details andspecifications shown.Bluestream Design Studio willnot be held liable for any errorsor omissions on these plans.
Design and layout or conceptsfor this design were provided toBluestream Design Studio bythe builder shown. Anysimilarities to other plans orblueprints is solely theresponsibility of the builder.Plans may not be reproduced orcopied without the expresswritten consent of the Buildershown.
SCALE:
OF
TMB
LBB
1/4" = 1'-0"
BUTTONWOOD KW GBI PERMITSET.dwg
11/7/19
S2
STRUCTURAL
10
Job
#:
627
Per
form
ed b
y V
icki
Lyn
ne
Bar
enb
erg
fo
r:B
utto
nwoo
d K
W G
BI
302
SW
Kan
e A
veP
ort S
t Luc
ie, F
L 34
953
Air
Cal
cs, L
LC
7550
Hid
den
Ham
moc
k Ln
Vero
Bea
ch, F
L 32
966
Pho
ne: 7
72.8
00.8
413
vick
ilynn
e@ai
rcal
cs.c
om
Sca
le: 1
: 10
5P
age
1R
ight
-Sui
te®
Uni
vers
al 2
019
19.0
.09
RS
U27
054
2019
-Oct
-14
08:2
6:43
...ts
oft H
VAC
\But
tonw
ood
KW
GB
I.ru
p
N
Lev
el 1
Gar
age
Pan
tryLa
undr
yFo
yer
Mas
ter S
uite
M B
ath
WIC
Kit/
DR
Bed
2Bed
4
WIC
4W
IC 3
Bed
3 Bat
h 2
Hal
l
Gre
at R
oom
10 x
10
148
cfm
10 x
685
cfm
8 x
892
cfm
12 x
12
268
cfm
6 x
635
cfm
10 x
685
cfm
12 x
814
4 cf
m12
x 1
217
0 cf
m
12 x
12
85 c
fm
10 x
682
cfm
8 x
426
cfm
8 x
456
cfm
12 x
12
138
cfm
10 x
10
128
cfm
10 x
10
148
cfm
18 x
18
719
cfm
10 "
18 "
6 "
8 "
8 "
6 "
6 "
10 "
7 "
16 "
7 "
7 "
6 "
12 "
4 "
4 "
5 "
8 "
6 " 6 x
659
cfm
10 x
10
128
cfm
10 x
665
cfm
6 x
651
cfm
8 x
892
cfm
8 x
437
cfm
5 "
7 "
5 "
4 "
6 "
4 "