a s b u i l t renewable energy system1:7 lead displacement plate ss (square shaft) extension...
TRANSCRIPT
12'-0"12'-0"
26'-0" 26'-0" 26'-0"
26
'-0
"6
'-0
3 4"
6'-
03 4"
12'-712" 12'-71
2"
78'-0"
38
'-1
1 2"
103'-234"
4'-0" 4'-0" 4'-0" 858"
1'-5"1'-5"
4'-0"4'-0"858"
1'-5"
12" HORIZONTAL Z - PURLIN
12" HORIZONTAL Z - PURLIN
Ø8" VSP
CL CL CL CL
C LC L
8" C- CHANNEL @ 15° TILT (TYP)
PV MODULE 26X65 (TYP)2'-
11 2"
POND
PARKING
+/-7'-0" CL
CONC. WALK
+/-65°
#A1 #A2 #A3 #A4A
B #B1 #B2 #B3 #B4
+/-
30
'-0
"
#A3
C L
TO
#A
3 A
DJ
AS
NE
ED
ED
GSAS CLAMP (TYP)
APPROX. POSITION OF LIGHT POLE
C1 C2 C3 C4 C5 C6 C7 C8 C9
C10 C11
C12 C13 C14 C15 C16 C17 C18 C19
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
R13
R14
R15
R16
R17
R18
23'-0" 29'-0"
MOVED COLOMUN LOCATION
DIAGONAL BRACING EA. ENDCANTILEVERED Z PURLIN
26'-0"
CL CL
+/-
11
'-0
" A
DJ.
HG
T A
S N
EE
DE
D
4'-
0"
≈2
'-6
"
≈1
2'-
10
"
≈1
5°
≈39'-812"
6'-2"26'-0"6'-2"
PV MODULE
GSAS CLAMP (TYP)
RAFTE R, C-CHANNEL
VERTICAL SUPPORT PIPE
HRZ SUPPORT, Z-BEAM
(3) U-BOLT & HARDWARE
FOUNDATION DESIGN BY CHANCE ATLAS THRU FOUNDATION CONTRACTOR IAW DRIGGERS ENGINEERING SPT TEST REPORT ”
Δ H
GT
7'-
0"
2'-2"
EXTENSION C10, C11
FINISHED GRADE
DIAGONAL BRACING EA. ENDCANTILEVERED Z PURLIN
TRIPLE 5/8" U-BOLT & HARDWARE
VERTICAL SUPPORT PIPE
HRZ SUPPORT, ZEE PURLIN
12" NUTS, BOLTS & WASHER
RAFTER, C-CHANNEL
PV MODULE
GSAS CLAMP& STAR WASHER
CRS TEK SCREW 1 4" - 20
PROVIDE COL. CAP,TO PREVENT WATER ENTRY
GASKETED WASHER OR ALTERNATE
2"x 2" 12GA HDG WASHER
CONNECTION REINFORCEMENT
CONNECTOR
2"x 2" 12GA HDG WASHER EACH END OF 4 BOLTS
SHEET NO:
PUBLISHED:
SHEET NAME:
DRAWN: CHECKED:SB AG
EN
LAR
GE
D V
IEW
ING
& H
YP
ER
LIN
KS:
PR
INT
VE
RS
ION
OF
TH
IS P
LAN
PR
OV
IDE
S M
INIM
UM
IN
FOR
MA
TIO
N N
EE
DE
D B
Y U
SER
S.E
LEC
TR
ON
IC V
ER
SIO
N (
EV
) P
RO
VID
ES
MA
GN
IFIE
D V
IEW
ING
UP
TO
64
00
%.
EV
ALS
O P
RO
VID
ES
HY
PE
RLI
NK
AC
CE
SS
TO
OE
M M
AN
UA
LS A
ND
AB
UN
DA
NT
OT
HE
R S
UP
PLE
ME
NT
AR
Y I
NFO
RM
AT
ION
.EV
MA
Y B
EA
CC
ES
SE
D A
T:
WW
W.G
EZ
ELM
AN
PE
.CO
M/P
V/
03
21
P.S
SO
_S
PC
_S
tPe
ters
bu
rg_
FL_
ASB
.dw
g
REVISIONS:
01SCALE: NTS
SITE INSTALLATION LOCATIONSCALE: NTS
SITE PHOTO
I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES ANDEQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT.ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2008 NATIONAL ELECTRICAL CODE. CERTAIN DETAILS OF THIS PROJECTMAY DIFFER, REFER TO OEM LITERATURE WHICH SHALL PREVAIL.
CONTRACTOR RESPONSIBLE TO VERIFY THE FIT OF THIS ARRAY PRIOR TO INSTALLATION: THE SOLAR MODULE ARRAY SHOWNHERE IS BASED ON THE FIELD DATA PROVIDED BY THE CONTRACTOR. CONTRACTOR SHALL CONTACT THE ENGINEER IF THEARRAY MAY NOT FIT AS PROJECTED. SATELLITE IMAGERY SHOWN MAY NOT CORRECTLY INDICATE POTENTIAL CURRENT SHADINGOF PROPERTY. CONTRACTOR RESPONSIBLE TO VERIFY SUN EXPOSURE AND SHADING OF INSTALLATION PRIOR TO INSTALLATION!
C
OP
Y R
IGH
T &
IN
TE
LLE
CT
UA
L P
RO
PE
RT
Y N
OT
ICE
•T
HIS
PLA
N S
ET
IS
CO
PY
RIG
HT
PR
OT
EC
TE
D A
ND
CO
NT
AIN
S IN
TE
LLE
CT
UA
L P
RO
PE
RT
Y W
HIC
H B
ELO
NG
S T
O A
LLE
N G
EZ
ELM
AN
PE
.
•A
CC
ES
S IS
GIV
EN
TO
TH
E I
NFO
RM
AT
ION
HE
RE
ON
SO
LELY
FO
R T
HE
PU
RP
OS
E O
F C
OM
PLE
TIO
N O
F T
HE
PR
OJE
CT
FO
R W
HIC
H IT
IS IN
TE
ND
ED
.
•N
O O
TH
ER
US
E M
AY
BE
MA
DE
OF
TH
E I
NF
OR
MA
TIO
N,
DR
AW
ING
S,
OR
ID
EA
S H
ER
EO
N W
ITH
OU
T T
HE
EX
PR
ESS,
WR
ITT
EN,
PE
RM
ISSI
ON
OF
ALL
EN
GE
ZELM
AN
PE
ALL AFFIDAVITS, DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDCC-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC C-700 ORPROVISIONS THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT, DESIGN, OPINION, CALCULATION OR OTHER ENGINEERING SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC
C-700 MAY BE VIEWED AT: HTTP://GEZELMANPE.COM/REFERENCE/AG/C-700.PDF
THIS PLAN IS ONLINE FOR REVIEW @
WWW.GEZELMANPE.COM/PV/0321P11.SSO_SPC_STPETERSBURG_FL.PDF
CO
NT
AC
T D
ES
IGN
TE
AM
@
ww
w.G
eze
lma
nP
E.c
om
ALLEN GEZELMAN16502 HANNA RD.LUTZ, FLORIDA 33549
PH. 813 650 7246FX. 866 397 9050Allen@Gezelman PE.COMwww.GezelmanPE.com
I CERTIFY THAT THIS DESIGN &SPECIFICATIONS MEET THE CURRENTFLORIDA BUILDING CODE
VULT 155_MPH, VASD 120.1_MPH, EXPOSURE: B, RISK CATEGORY: III
CO
DE
VE
RIF
Y
MODULE# ANY FSEC APPROVED PV MODULE
DESIGNED PER: ASCE 7-10, FBC 2010
CONTRACTOR:
PINELLAS COUNTY, PARCEL ID# 21-30-15-00000-110-0100
INST
ALL
AT
ION
OF
A G
RO
UN
D M
OU
NT
- A
S B
UIL
T
RE
NE
WA
BLE
EN
ER
GY
SY
STE
M
ST P
ET
ER
BU
RG
CO
LLE
GE
SIT
US
: 9
20
0 1
13
TH
ST
SE
MIN
OLE
33
77
2
PRESSURE ZONES: HTTP://WWW.GEZELMANPE.COM/REFERENCE/WIND_US.PDF
11.17.2013
OWNER OF RECORD:
PO BOX 13489, ST PETERSBURG FL 33733-3489
ST PETERSBURG JR COLLEGE BD OF TRUSTEES
05SCALE: 1/8"" = 1'-0"
SITE LAYOUT INSTALLATION PLAN, 344 PV MODULES W/ 19 COL E/W AND 18 ROWS N/S
STRUCTURAL INSTALLATION NOTES (ELECTRICAL DESIGN BY OTHERS):SPC SEMINOLE CAMPUS 50 KW PV GROUND MOUNTSOLAR CONTRACTOR SHALL POSITION ARRAY IN GENERAL AREA INDICATED IN DRAWING FIGURE HEREON. LONG AXIS OF ARRAYSHALL PARALLEL CENTER LINE OF SEWER BETWEEN TWO MANHOLES WITHIN INSTALLATION AREA. GROUND-PENETRATINGRADAR INDICATES NOTHING OTHER THAN SEWER WITHIN INSTALLATION AREA.FOUNDATION CONTRACTOR SHALL INSTALL 8 FOUNDATIONS WITH 8-INCH DIAMETER VSP (VERTICAL SUPPORT PIPES) PERDRAWING HEREON AND LOCATION COORDINATION WITH SOLAR CONTRACTOR. FOUNDATION DESIGN SHALL BE PER CHANCEATLAS RECOMMENDATIONS IAW (IN ACCORDANCE WITH) DRIGGERS ENGINEERING TEST REPORT FROM STANDARDPENETRATION TESTING PERFORMED 2013 OCTOBER 28. SAID TESTING PROVED DENSE SAND FROM GRADE TO A DEPTH OF ATLEAST 25-FT WITH BLOW COUNTS IN THE HIGH 30S.
ABOVE GRADE SOLAR CONSTRUCTION SHALL USE 8-INCH DIAMETER, SCHEDULE 40, GALVANIZED STEEL PIPE AS VSP (VERTICALSUPORT PIPE). VSPS SHALL BE GROUT BONDED TO HPM (HELICAL PULLDOWN MICROPILE) FOUNDATIONS. 3-FOOT DEEP GROUTCOLLAR, 14-INCHES IN DIAMETER SHALL EXTEND DOWNWARD FROM GRADE TO BOTTOM OF GROUT RESERVOIR. HPM SHALLEXTEND DOWNWARD TO BOTTOM HELIX WHICH SHALL BE MINIMUM OF 10-FT BELOW GRADE.EAST-WEST MAIN FRAMING SHALL BE GALVANIZED STEEL, 12-GAGE, 12-INCH, Z-PURLINS SUPPLIED BY ALLSTEEL BUILDINGS OFGIBSONTON, FL. NORTH-SOUTH RAILS SHALL BE 8-INCH C-CHANNELS, SAME SOURCE, SAME SPECIFICATION. UNLESS OTHERWISE
NOTED OR SPECIFIED, ALL STRUCTURAL MOUNTING HARDWARE, NUTS, BOLTS, WASHERS TO BE 12".
ALL FASTENERS, BOLTS, NUTS WASHERS SHALL BE GALVANIZED OR STAINLESS STEEL”.U-BOLTS SHALL BE TORQUED TO 100-FT POUNDS”.
PV MODULES SHALL ATTACH TO RAILS USING GSAS MID-CLAMPS & 1/4-20 TEK CRS (CORROSION RESISTANT STEEL)CONSTRUCTION FASTENERS. STAINLESS STEEL OUTSIDE STAR WASHERS SHALL BE INSERTED BETWEEN GSAS MID-CLAMP ANDMODULES TO ENSURE ELECTRICAL BONDING OF ALL COMPONENTS. CONTRACTOR IS FREE TO USE END CLAMP OF HIS CHOICESUBJECT TO EOR (ENGINEER OF RECORD) APPROVAL.
SPC REVIEW COMMENTS AVAILABLE@ WWW.GEZELMANPE.COM/PV/0321P11.SSO_SPC_STPETERSBURG_FL.PDF , PAGE 3
EOR AVAILABLE FOR QUESTIONS: 813 909 1956 [email protected]
10840 ENDEAVOUR WAYLARGO, FL 33777
PH. 800 329 1301CVC 056646
INSTALLATION LOCATION INSTALLATION LOCATION
04SCALE: 1" = 1'-0"
STRUCTURAL MEMBER CONNECTION DETAIL
MAX PV ARRAY: UPLIFT (NEGATIVE) 89.8 KIPSSLIDING 23.2 KIPS, OVERTURNING 179.6 KIP FT, HEIGHT 0-15 FT
STRUCTURAL STEEL MEMBERS BOM
STRUCTURAL MEMBER DESCRIPTION QUANTITY
VERTICAL SUPPORT PIPE Ø8" GALV SCHED 40 PIPE4PCS 11-FT, 4PCS 4-FT +BELOW GRADEPER CHANCE ATLAS
HORIZONTAL SUPPORT BEAM 12" ZEE PURLINS 12 GA 40 FT 6 PCS LAPPED LENGTH 102-FT
RAFTERS 15 DEG TILT 8" C-CHANNEL 12 GA, LENGTH ≈ 40 FT 17 COL X 2 = 34 RAFTERS @≈40 FT
EXTENDED RAFTERS 15 DEG TILT 8" C-CHANNEL 12 GA, LENGTH ≈ 42 FT 2 COL X 2 = 4 RAFTERS @≈ 42 FT
03SCALE: 1/4" = 1'-0"
CROSS SECTION THROUGH ARRAY
INSTALLATION LOCATION
GSAS SOLAR CLAMP, MID FIELD
S.S. ELECTRICAL BONDING 'STAR' WASHER
0203SCALE: NTS
PARCEL - PROPERTY APPRAISER
PV21
A
PV21
B
PV21
A
WIN
D
1
1
1
A S B U I L T
DIAGONAL BRACING EA. END OF CANTILEVERED Z PURLINVSP RAIN SHIELD
ADJ HGTBRACE
RAIN SHIELD
1:7
LeadDisplacement
Plate
SS (Square Shaft)Extension
Reservoir
Neat CementGrout
(Very Flowable)
ExtensionDisplacement
Plate
Gout
Standard
R R
R
HELICAL PULLDOWN MICROPILE
®
SEE CHART
TYPICAL UNCASED APPLICATION
HELICAL PULLDOWN MICROPILE®
Lead Section
SHAFTMATERIAL
HELIXSTEELGRADE
LEAD SECTIONS
18" MIN.(SEE NOTE 10)
TORQUE RATING (FT-LB)
1/14/26/05KSH
SC B
1:2.5
R R
R
SEE CHART
DISPLACEMENT PLATES FOR UN-CASED GROUT COLUMNS
1/18/10/04KSH
SB CSA150-0330
PLATESDISPLACEMENT
3.5
00
1.2
50
1.2
50
2.500
6.0
00
Ø0.500
12 GA
10
.00
0
18.000
10
.00
0
9.250
0.6
25
0.750
2.3
44
2.6
56
2.6
56
2.3
44
2.0
31
2.0
31
2.0
31
2.0
31
4.375
12 GA
Ø0.625
2.000
2.0
00
Ø8" VSP ABV GRADE HGT VARIES
36
.00
2GRADE
Ø16" PILE CAP,5000 PSI NON-SHRINKING GROUT
CHANCE HPM HELICAL PULLDOWNMICROPILE
BOTTOM HELIXMIN. 10 FT BELOW GRADE
14.000
HPM
SQUARE SHAFT HPM
Ø8" VSP
VSP - HPM GROUTBOND REINFORCEMENT
(2) #4 REBARS
#3 STIRRUPS @ 6" C-C
Ø8" VSP
SHEET NO:
PUBLISHED:
SHEET NAME:
DRAWN: CHECKED:SB AG
EN
LAR
GE
D V
IEW
ING
& H
YP
ER
LIN
KS:
PR
INT
VE
RS
ION
OF
TH
IS P
LAN
PR
OV
IDE
S M
INIM
UM
IN
FOR
MA
TIO
N N
EE
DE
D B
Y U
SER
S.E
LEC
TR
ON
IC V
ER
SIO
N (
EV
) P
RO
VID
ES
MA
GN
IFIE
D V
IEW
ING
UP
TO
64
00
%.
EV
ALS
O P
RO
VID
ES
HY
PE
RLI
NK
AC
CE
SS
TO
OE
M M
AN
UA
LS A
ND
AB
UN
DA
NT
OT
HE
R S
UP
PLE
ME
NT
AR
Y I
NFO
RM
AT
ION
.EV
MA
Y B
EA
CC
ES
SE
D A
T:
WW
W.G
EZ
ELM
AN
PE
.CO
M/P
V/
03
21
P.S
SO
_S
PC
_S
tPe
ters
bu
rg_
FL_
ASB
.dw
g
REVISIONS:
I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES ANDEQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT.ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2008 NATIONAL ELECTRICAL CODE. CERTAIN DETAILS OF THIS PROJECTMAY DIFFER, REFER TO OEM LITERATURE WHICH SHALL PREVAIL.
C
OP
Y R
IGH
T &
IN
TE
LLE
CT
UA
L P
RO
PE
RT
Y N
OT
ICE
•T
HIS
PLA
N S
ET
IS
CO
PY
RIG
HT
PR
OT
EC
TE
D A
ND
CO
NT
AIN
S IN
TE
LLE
CT
UA
L P
RO
PE
RT
Y W
HIC
H B
ELO
NG
S T
O A
LLE
N G
EZ
ELM
AN
PE
.
•A
CC
ES
S IS
GIV
EN
TO
TH
E I
NFO
RM
AT
ION
HE
RE
ON
SO
LELY
FO
R T
HE
PU
RP
OS
E O
F C
OM
PLE
TIO
N O
F T
HE
PR
OJE
CT
FO
R W
HIC
H IT
IS IN
TE
ND
ED
.
•N
O O
TH
ER
US
E M
AY
BE
MA
DE
OF
TH
E I
NF
OR
MA
TIO
N,
DR
AW
ING
S,
OR
ID
EA
S H
ER
EO
N W
ITH
OU
T T
HE
EX
PR
ESS,
WR
ITT
EN,
PE
RM
ISSI
ON
OF
ALL
EN
GE
ZELM
AN
PE
ALL AFFIDAVITS, DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDCC-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC C-700 ORPROVISIONS THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT, DESIGN, OPINION, CALCULATION OR OTHER ENGINEERING SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC
C-700 MAY BE VIEWED AT: HTTP://GEZELMANPE.COM/REFERENCE/AG/C-700.PDF
THIS PLAN IS ONLINE FOR REVIEW @
WWW.GEZELMANPE.COM/PV/0321P11.SSO_SPC_STPETERSBURG_FL.PDF
CO
NT
AC
T D
ES
IGN
TE
AM
@
ww
w.G
eze
lma
nP
E.c
om
ALLEN GEZELMAN16502 HANNA RD.LUTZ, FLORIDA 33549
PH. 813 650 7246FX. 866 397 9050Allen@Gezelman PE.COMwww.GezelmanPE.com
I CERTIFY THAT THIS DESIGN &SPECIFICATIONS MEET THE CURRENTFLORIDA BUILDING CODE
CONTRACTOR:
INST
ALL
AT
ION
OF
A G
RO
UN
D M
OU
NT
-AS
BU
ILT
RE
NE
WA
BLE
EN
ER
GY
SY
STE
M
ST P
ET
ER
BU
RG
CO
LLE
GE
SIT
US
: 9
20
0 1
13
TH
ST
SE
MIN
OLE
33
77
2
11.11.2013
OWNER OF RECORD:
PO BOX 13489, ST PETERSBURG FL 33733-3489
ST PETERSBURG JR COLLEGE BD OF TRUSTEES
ASCALE: NTS
FOUNDATION: CHANCE ATLAS HELICAL PULLDOWN MICROPILES
10840 ENDEAVOUR WAYLARGO, FL 33777
PH. 800 329 1301CVC 056646
B SCALE: 1-1/2" = 1'-0"
STRUCTURAL MEMBER CONNECTION DETAIL
SCALE: 1:2
"C" CHANNEL TO "Z" PURLIN CONNECTOR
SCALE: 3"=1'-0"
"Z" PURLIN TO VSP REINFORCEMENT PLATE
SCALE: 1:2
2" X 2" WASHER
SCALE: 3/4"= 1'-0"
FOUNDATION PILE CAP DETAIL
1
A S B U I L T