a304 - vancouver...1090 west pender street, vancouver bc a304 211031 development permit building...

1
Level 28 400' - 0" Level 29 411' - 10" Level 30 423' - 8" Level 31 437' - 8" Level 32 453' - 2" T.O. Parapet 465' - 9" 3 2 4 5 6 GR GL5 GL1 GL3 MF GL4 GL2 Level 1 62' - 3" Level 2 86' - 0" Level 3 102' - 0" Level 4 116' - 0" Level 5 127' - 10" Level 6 139' - 8" 3 2 4 5 6 Loading 74' - 0" GL1 GL3 GL5 GL5 MP GL2 MF GL2 GR GL9 All rights reserved, property of Musson Cattell Mackey Partnership. Use or reproduction prohibited without prior written permission Sheet Project Scale Drawing Project Seal Revisions DD MMM YYYY 1/8" = 1'-0" 8/22/2017 12:19:00 PM C:\CADTemp\211031_1090 W Pender_ARCH_CEN_jmu.rvt 1090 West Pender Street, Vancouver BC A304 211031 DEVELOPMENT PERMIT BUILDING ELEVATION ENLARGEMENT - NORTH 1090 WEST PENDER SCALE: A304 1/8" = 1'-0" BUILDING ELEVATION - NORTH - TOP 1 SCALE: A304 1/8" = 1'-0" BUILDING ELEVATION - NORTH - BOTTOM 2 EXTERIAL MATERIAL ABR. MATERIAL AC ARCHITECTURAL CONCRETE C/W REVEALS W CLEAR SEALER BR BICYCLE RAKE GL1 TRIPLE GLAZED VISION UNITS, TINTED GLASS GL2 TRIPLE GLAZED VISION UNITS, CLEAR GLASS C/W FEATURE VERTICAL CAPS GL3 DOUBLE GLAZED IG SPANDREL UNITS C/W INSULATED BACK PANS, TINTED GLASS GL4 DOUBLE GLAZED IG SPANDREL UNITS C/W INSULATED BACK PANS GL5 DOUBLE GLAZED VISION UNITS, CLEAR GLASS GL7 SINGLE GLAZED - TINTED GL9 DOUBLE GLAZED VISION UNIT, CLEAR FRITTED GLASS W PROGRAMED LED LIGHT GR VEGETATION GREEN ROOF GT TEMPERED CLEAR GLASS FIN LV PREFINISHED ALUMINUM LOUVRE MF ALUMINUM PREFINISHED FLASHING MP ALUMINUM COMPOSITE PANEL RG ROLL-UP ALUMINUM GRILL DOOR SG GALVANIZED STEEL GRATING 1 25 Aug 2017 Issued for DP

Upload: others

Post on 27-Feb-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: A304 - Vancouver...1090 West Pender Street, Vancouver BC A304 211031 DEVELOPMENT PERMIT BUILDING ELEVATION ENLARGEMENT - NORTH 1090 WEST PENDER A304 SCALE: 1/8" = 1'-0" 1 BUILDING

Level 28

400' - 0"

Level 29

411' - 10"

Level 30

423' - 8"

Level 31

437' - 8"

Level 32

453' - 2"

T.O. Parapet

465' - 9"

3 2456

GR GL5

GL1

GL3

MF

GL4

GL2

Level 1

62' - 3"

Level 2

86' - 0"

Level 3

102' - 0"

Level 4

116' - 0"

Level 5

127' - 10"

Level 6

139' - 8"

3 2456

Loading

74' - 0"

GL1

GL3

GL5

GL5

MP GL2 MF

GL2

GR

GL9

All rights reserved, property of Musson Cattell Mackey Partnership. Use or reproduction prohibited without prior written permission

Sheet

Project

Scale

Drawing

Project

Seal

Revisions DD MMM YYYY

1/8" = 1'-0"

8/22/2017 12:19:00 PMC:\CADTemp\211031_1090 W Pender_ARCH_CEN_jmu.rvt

1090 West Pender Street,

Vancouver BC

A304

211031

DE

VE

LOP

ME

NT

PE

RM

IT

BUILDING

ELEVATION

ENLARGEMENT

- NORTH

1090 WEST

PENDER

SCALE:A304 1/8" = 1'-0"

BUILDING ELEVATION - NORTH - TOP1

SCALE:A304 1/8" = 1'-0"

BUILDING ELEVATION - NORTH - BOTTOM2

EXTERIAL MATERIAL

ABR. MATERIAL

AC ARCHITECTURAL CONCRETE C/W REVEALS WCLEAR SEALER

BR BICYCLE RAKE

GL1 TRIPLE GLAZED VISION UNITS, TINTED GLASS

GL2 TRIPLE GLAZED VISION UNITS, CLEAR GLASSC/W FEATURE VERTICAL CAPS

GL3 DOUBLE GLAZED IG SPANDREL UNITS C/WINSULATED BACK PANS, TINTED GLASS

GL4 DOUBLE GLAZED IG SPANDREL UNITS C/WINSULATED BACK PANS

GL5 DOUBLE GLAZED VISION UNITS, CLEARGLASS

GL7 SINGLE GLAZED - TINTED

GL9 DOUBLE GLAZED VISION UNIT, CLEARFRITTED GLASS W PROGRAMED LED LIGHT

GR VEGETATION GREEN ROOF

GT TEMPERED CLEAR GLASS FIN

LV PREFINISHED ALUMINUM LOUVRE

MF ALUMINUM PREFINISHED FLASHING

MP ALUMINUM COMPOSITE PANEL

RG ROLL-UP ALUMINUM GRILL DOOR

SG GALVANIZED STEEL GRATING

1 25 Aug 2017 Issued for DP