Delta “T” Systems A-60 Rated Fire Dampers - Round and Rectangular - Standard and Custom Sizes - Stainless Steel Construction

Upload: ninazr

Post on 22-Feb-2015

94 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: A60 Damper Brochure

Delta “T” Systems

A-60 Rated Fire Dampers

- Round and Rectangular- Standard and Custom Sizes- Stainless Steel Construction

Page 2: A60 Damper Brochure

A-0 Through A-60 Rated Round Marine Fire Dampers

Delta “T” Systems’ A-60 Rated Round Fire Dampers have been designed specifically for marine applications. Available in standard and custom sizes ranging from 12 inches to 36 inch-es (305 mm to 914mm) in diameter with either electric or pneumatic actuation.

The design of both the electric and the pneumatic dampers incorporate redundant closure modes for an extra level of safety. Closure of either damper modelmay be triggered by the fire monitoring/supression system, or if the fire system fails, the dampers themselves will sense the excess heat from a fire and close automatically. The electrically actuated damper senses the excess heat by using an ElectricalThermal Release (ETR), and the pneumatically actuated damper utilizes a fusible link for the same purpose. All 700-A60R Round Dampers are manufactured using high-grade stainless steel and the finest marine grade components.

OverviewUSCG Approved

US COASTGUARD

APPROVED

MED APPROVED

Delta “T” Systems’ 700-A60R line of dampers have passed a strict battery of tests in order to earn their A-60 rating, in acordance with the National Fire Protection Association (NFPA) Resolution A.754(18). Approved for use with both BELIMO and ACTIONAIR actuators.

Approval Number 164.139/10/0

1408/09

Page 3: A60 Damper Brochure

A-0 Through A-60 Rated Round Marine Fire DampersDimension E

Dimension B

Dimension C

Dimension F

Dimension D

Dimension A

Damper Size A B C D E F ID Bolt Circle OD Housing Length Blade Bolt Holes

12.0 in. 12.0 in. 13.75 in. 14.75 in. 10.0 in. 2.7 in. 8 x 3/8 in. 304.8 mm 304.8 mm 349.3 mm 374.7 mm 254.0 mm 68.6 mm 8 x 9.5 mm

15.0 in. 15.0 in. 16.69 in. 17.75 in. 11.0 in. 4.65 in. 8 x 7/16 in. 381.0 mm 381.0 mm 323.9 mm 450.9 mm 279.4 mm 118.1 mm 8 x 11.0 mm

19.0 in. 19.0 in. 20.75 in. 21.75 in. 13.5 in. 6.15 in. 8 x 9/16 in. 482.6 mm 482.6 mm 527.1 mm 552.5 mm 342.9 mm 156.2 mm 8 x 14.3 mm

21.0 in. 21.0 in. 22.75 in. 23.69 in. 14.5 in. 7.15 in. 12 x 9/16 in. 533.4 mm 533.4 mm 577.9 mm 601.7 mm 368.3 mm 181.6 mm 12 x 14.3mm 24.0 in. 24.0 in. 25.75 in. 26.75 in. 15.5 in. 9.15 in. 12 x 9/16 in. 609.6 mm 609.6 mm 654.1 mm 679.5 mm 393.7 mm 232.4 mm 12 x 14.3 mm

30.0 in. 30.0 in. 32.3 in. 33.75 in. 19.5 in. 11.15 in. 16 x 9/16 in. 762.0 mm 762.0 mm 820.7 mm 857.3 mm 495.3 mm 283.2 mm 16 x 14.3 mm

36.0 in. 36.0 in. 38.0 in. 39.75 in. 22.5 in. 14.15 in. 16 x 9/16 in. 914.4 mm 914.4 mm 965.2 mm 1009.7 mm 571.5 mm 359.4 mm 16 x 14.3 mm

Standard Dimensions

Delta “T” Systems’ 700-A60R Round Dampers in this line have been designed to couple directly to our high output marine axial fans. This damper/fan combination provides maximum air movement and a rated fire closure capability in one space saving package. Contact one of our application engineers or visit www.deltatsystems.com for more information.

The Perfect Pair

Page 4: A60 Damper Brochure

A-60 Rated Rectangular Marine Fire Dampers

MED APPROVED

Delta “T” Systems’ A-60 Rated Rectangular Fire Dampers have been constructed from 316 stainless steel, with interlocking blades, end bearings and stainless steel peripheral gasket-ing. The blade linkage has been completely enclosed and positioned out of the air stream for protection against damage. Actuation is available in both electric and pneumatic.

• Tested and approved for class A-60 divisions (bulkheads and decks)• Lloyds Register of Shipping Approval to IMO Fire Test Procedures Code, Annex 1, Part 3• Complies to Marine Equipment Directive 96/98/EC• Corrosion tested to BS EN 60068-2-52. Severity 2 conditions• Vibration tested to BS EN 60068-2-6 (5 Hz - 35Hz @ 2g)

Overview

FRAME - 6” x 18 gage (150 mm x 1.2 mm)

galvanized, flanged channel.

MAXIMUM SIZE - 39.4” x 39.4” (1.0 m x 1.0 m)

BLADES - Airfoil-shaped, double-skin, Type

430 Ferritic stainless steel construction.

Maximum 3” (76 mm) wide.

BEARINGS - Stainless steel blade end bearing

and peripheral gasketing.

JAMB SEALS - Stainless steel, flexible metal

compression type. Full perimeter.

LINKAGE - Concealed in frame.

ETR72 - (Electrical Thermal Release)

threshold temperature - 161°F (72°C)

USCG Approval Number164.139/EC0038

Standard Construction

MED 0450262

Page 5: A60 Damper Brochure

Delta “T” Systems’ round and rectangular dampers may be actuated electrically using either AC or DC power. Closure of the electri-cally actuated damper may be initiated in one of three ways:1) Signal from the fire system2) Loss of electric power to the actuator3) Sensing of heat by the actuator’s Electrical Thermal Release (ETR)

Electric Actuation

In order to facilitate the automatic closing of the damper, an Electrical Thermal Release (ETR) is mounted on the damper housing to sense elevated temperatures of 162 ° F (72 ° C ) or above and trigger the closing of the damper. The fail-safe feature of this actuator causes the damper blade(s) to close in the event that power to the actuator is lost. A green LED light is built into the ETR to give the user a clear and simple visual check that the actuator is receiv-ing power, the ETR is correctly fitted, and the thermal fuse is intact.

Pneumatic Actuation

Pneumatic actuation is available on both round and rectangular models of the A-60 damper. A fusible link has been incorporated into the design of the pneumatic version of Delta “T” Systems’ A-60 Round Damper in order to facilitate failsafe closure of the damper. The fusible link functions independently of the pneumatic release in order to allow the damper to close in the event that the ambient temperature reaches a pre-determined threshold. A spring on the damper’s blade shaft serves to provide the necessary torque to close the damper and a locking pin engages when the blade is fully close in order to secure the closure. Pneumatic actuation may be achieved through an onboard pneumatic supply line or with an optional Actuator Gas Cyllinder (Part Nos. 273-P150/12 or 273-P150/24) pictured to the right. Dampers may also be manually actuated and reset from the outside of the damper housing.

Multiple Damper ArrangementsDelta “T” Systems’ line of rectangular dampers may be joined in a wide variety of configurations in order to provide closure to any size of space. This is true of our standard line of dampers as well as our A-60 rated line of fire dampers.