WIRE ASM-110V TO LEFT SIDE GENERATOR 3. 2. 5 ALL GROUND WIRE TO BE COVERED WITH TUBING 8041-02-000. ALL 110V WIRE TO BE CLAMPED WITH CLAMP 10497-05-000 WITHIN 200MM OF OUTLET BOXES, USE SCREW G67-10-12B. 4. SEE WIRING DIAGRAM-BODY,110V FOR ADDITIONAL INFORMATION. POWER CORD BOX FOR ELECTRICAL TORQUE SPECIFICATIONS SEE DWG NO. 128783-01-000 NOTES: ALL WIRES TO BE SECURED WITH CLAMP 10495-01-000 OR CLIP 80734-01-000 EVERY 600MM. USE SCREW G67-10-12B UNLESS OTHERWISE SPECIFIED. SEE GENERATOR INSTL FOR ADDITIONAL INFORMATION. 5 1. 6 WIRE ASM-110V ROUTED UNDER FLOOR IN THIS AREA. 12D 265 1B1 CODES/STANDARDS-CSA/CMVSS 12D ELECTRICAL SYSTEM 30 AMP 1B1 CODES/STANDARDS USA 265 X-X FOR ELECTRICAL CALLOUTS SEE DWG NO. 121339-01-000 7 7 WIRE ASM-110V PASSES THROUGH FLOOR IN THIS AREA. 8 FLEX CORD IS PART OF WIRE ASM-CHASSIS. 9 SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION. 9 FEATURES DRAWING NO. 301476-01 301476-11 ---------- 301476-15 265 12D 1B1 12D INVERTER-1000 WATT (REF) 9 WIRE ASM-110V TO RIGHT SIDE 7 GENERATOR 4X4 BOX 5 6 9 GENERATOR CABLE ASM FLEXCORD TO DINETTE 8 AA 9 5 GENERATOR CABLE CLAMP 10497-01-000 (3) SCREW G39-08-12U (3) CLAMP 10497-01-000 SCREW G39-08-12U VIEW AA ATS 9 MAIN TO LOAD CENTER POWER CORD 3 UNSPECIFIED TOLERANCES: MATERIAL: C D 1 TWO-PLACE (X.XX) DSNR: DESCRIPTION: 8 2 B ALL DIMENSIONS ARE IN MILLIMETERS DFTR: 6 A 6 FIRST USED: A REV WHOLE DIM (X) D REF: 8 ITEM/PART NO: 4 WEIGHT: (LBS) SHEET: 7 B 2 4 REFER TO ES0018 FOR FASTENER TIGHTENING GUIDELINES ANGLE 5 5 1 3 COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC. ONE-PLACE (X.X) C 7 WIRING INSTL-BODY,110V 1 OF 4 000181586 / 30147601000 3 1.5 0.50 1 20-Sep-2016

Upload: others

Post on 09-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AAAA GENERATOR CABLE 9 5 CLAMP 10497-01-000 (3) SCREW G39-08-12U (3) CLAMP 10497-01-000 SCREW G39-08-12U VIEW AA ATS 9 MAIN TO LOAD CENTER POWER CORD 3 UNSPECIFIED TOLERANCES C D 1

WIRE ASM-110VTO LEFT SIDE

GENERATOR

3.

2.

5

ALL GROUND WIRE TO BE COVERED WITH TUBING 8041-02-000.

ALL 110V WIRE TO BE CLAMPED WITH CLAMP 10497-05-000WITHIN 200MM OF OUTLET BOXES, USE SCREW G67-10-12B.

4. SEE WIRING DIAGRAM-BODY,110V FOR ADDITIONAL INFORMATION.

POWER CORD BOX

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

NOTES:

ALL WIRES TO BE SECURED WITH CLAMP 10495-01-000OR CLIP 80734-01-000 EVERY 600MM. USE SCREWG67-10-12B UNLESS OTHERWISE SPECIFIED.

SEE GENERATOR INSTL FOR ADDITIONAL INFORMATION.5

1.

6 WIRE ASM-110V ROUTED UNDER FLOOR IN THIS AREA.

12D2651B1

CODES/STANDARDS-CSA/CMVSS

12D ELECTRICAL SYSTEM 30 AMP

1B1 CODES/STANDARDS USA

265

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

7

7 WIRE ASM-110V PASSES THROUGH FLOOR IN THIS AREA.

8 FLEX CORD IS PART OF WIRE ASM-CHASSIS.

9 SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.

9

FEATURESDRAWING NO.

301476-01

301476-11

----------

301476-15 265 12D

1B1 12D

INVERTER-1000 WATT(REF) 9

WIRE ASM-110VTO RIGHT SIDE 7

GENERATOR 4X4 BOX5

6

9 GENERATOR CABLE ASM

FLEXCORDTO DINETTE8

AA

9 5GENERATOR CABLE

CLAMP10497-01-000 (3)SCREWG39-08-12U (3)

CLAMP10497-01-000SCREWG39-08-12U

VIEW AA

ATS 9

MAINTO LOADCENTER

POWER CORD

3

UNSPECIFIED TOLERANCES: MATERIAL:

C

D

1

TWO-PLACE (X.XX)

DSNR:

DESCRIPTION:

8

2

B

ALL DIMENSIONS ARE IN MILLIMETERSDFTR:

6

A

6

FIRST USED:

A

REV

WHOLE DIM (X)

D

REF:

8

ITEM/PART NO:

4

WEIGHT: (LBS)

SHEET:

7

B

2

4

REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES

ANGLE

5

5

13

COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC.

ONE-PLACE (X.X)

C

7

WIRING INSTL-BODY,110V

1 OF 4 000181586 / 30147601000

3

1.5

0.50

1

20-Sep-2016

Page 2: AAAA GENERATOR CABLE 9 5 CLAMP 10497-01-000 (3) SCREW G39-08-12U (3) CLAMP 10497-01-000 SCREW G39-08-12U VIEW AA ATS 9 MAIN TO LOAD CENTER POWER CORD 3 UNSPECIFIED TOLERANCES C D 1

1. ALL WIRES TO BE SECURED WITH CLAMP 10495-01-000OR CLIP 80734-01-000 EVERY 600MM. USE SCREWG67-10-12B UNLESS OTHERWISE SPECIFIED.

2. ALL 110V WIRE TO BE CLAMPED WITH CLAMP 10497-05-000WITHIN 200MM OF OUTLET BOXES, USE SCREW G67-10-12B.

3. ALL GROUND WIRE TO BE COVERED WITH TUBING 8041-02-000.

4.

SP-04

6 WIRE ROUTED THROUGH FLOOR AT THIS POINT.

110V CONNECTIONDETAIL BA

RCP-2 (BRN-2)DINETTE,OVHD

RCP-B (BRN-2)BDRM OVHD

RCP-2 (BLU)BATH

RCP-2 (BRN-2)BEDROOM

12D

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

NOTES:

SEE WIRING DIAGRAM-BODY,110V FOR ADDITIONAL INFORMATION.

SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.5

CODES/STANDARDS-CSA/CMVSS

2651B1

265

CODES/STANDARDS USA1B1

ELECTRICAL SYSTEM 30 AMP

12D

7 WIRE ROUTED IN SIDEWALL.

CLAMP10495-01-000 (2)SCREWG67-10-12U (2)

DETAIL BA

CONNECTOR-WIRE,NM144283-02-000SCREWG39-06-24U (4)

TO RCP-2DINETTE

110V CONNECTIONUNDER DINETTE

7

WIRE ASM-110VFROM RIGHT SIDE(BLU) 9500 DROP(MAIN) 5000 DROP

5 6

110V FROMLOAD CENTER

RCP-2 (BRN-2)BEDROOM

RCP-B (BRN-2)BDRM OVHD

FROM ROOF

FLEX CORDFROM CHASSISTO SLIDEOUT

FLEX CORD IS PART OF WIRE ASM-CHASSIS.

9

8 ROUTED BELOW FLOOR WITH WIRE ASM-CHASSIS.

9

8FROM

WIRE ASM-CHASSIS

RCP-2 (BLU)HALLWAY

RCP-E (BLU)TRUNK

FROM SIDEWALL

TO BDRM RCP LH

TO BDRM RCP RH

49M

AIR SLEEP SYSTEM-QUEEN SIZE49M

THROW IN WIRE #4

7

RCP-3 (BRN-2)AIR MATTRESS

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,110V

000181586 / 30147601000 2 OF 420-Sep-2016

Page 3: AAAA GENERATOR CABLE 9 5 CLAMP 10497-01-000 (3) SCREW G39-08-12U (3) CLAMP 10497-01-000 SCREW G39-08-12U VIEW AA ATS 9 MAIN TO LOAD CENTER POWER CORD 3 UNSPECIFIED TOLERANCES C D 1

WIRE IN SIDEWALL

8

ALL 110V WIRE TO BE CLAMPED WITH CLAMP 10497-05-000WITHIN 200MM OF OUTLET BOXES, USE SCREW G67-10-12B.

7

3.

SEE WIRING DIAGRAM-BODY,110V FOR ADDITIONAL INFORMATION.

6

4.

WIRE ROUTED THROUGH FLOOR AT THIS POINT.

2.

ALL GROUND WIRE TO BE COVERED WITH TUBING 8041-02-000.

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

11

GFI-1 US (BLU)GALLEY

GFI-1 CA (BLU)GALLEY

RCP-E (BLU)EXTERIOR

RCP-B (RED)ROOF

2651B1

1B1 CODES/STANDARDS USA

265 CODES/STANDARDS-CSA/CMVSS

NOTES:

ALL WIRES TO BE SECURED WITH CLAMP 10495-01-000OR CLIP 80734-01-000 EVERY 600MM. USE SCREWG67-10-12B UNLESS OTHERWISE SPECIFIED.

5

1.

9 FLEX CORD PART OF WIRE ASM-CHASSIS.

10 WIRE CONNECTS TO INVERTER.

LOCATE REFRIGERATOR RECEPTACLE ON TIEDOWN BRACKET.11

SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.

8 RELAY-EMS

110V TO WATER HEATER

RCP-1 (BLK)MICROWAVE

12D

12D ELECTRICAL SYSTEM 30 AMP

WIRE PART OF WIRE ASM-110V.

THROW IN WIRE #2THROW IN WIRE #5DETAIL CA

WIRE TO SLIDEOUT

10 8

110V TOGALLEY SDWL RCP

9

5

THROW IN WIRE #1110V CONNECTIONTO FRONT SLIDEOUTDETAIL CA

7

WIRE ASM-110VTO LEFT SIDE6

DETAIL CA

CONNECTOR-WIRE,NM144283-01-000SCREWG39-06-24U (12)

BRACKET-110V155223-09-CHTSCREWG67-08-12U (2)

110V CONNECTION(UNDER GALLEY)

CLAMP10495-01-000 (6)SCREWG67-10-12U (6)

FROM LOAD CENTER(BRN)

110V OUTPUTFROM INVERTER

(BRN-2)

110V TOINVERTER

(BRN)

THROW INWIRE #58

THROW INWIRE #28

8THROW INWIRE #1

RCP-B (BRN-2)GALLEY #1

RCP-B (BRN-2)ROOF

FROM RCP-B GALLEY(BRN-2)

TO RCP-B GALLEY(BRN-2)

110V CONNECTORTO FRONT SLIDEOUT(BRN-2)

9

RCP-2 (BRN-2)LOUNGE TV

LOAD CENTER/ATS ASM192237-01-000

RCP-3 (YEL)REFRIGERATOR

BRACKET-110V CONNECTOR,MOUNT194220-01-CHTSCREW000G39-08-12U (3)

79W REFRIGERATOR-4 DOOR

79W

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,110V

000181586 / 30147601000 3 OF 420-Sep-2016

Page 4: AAAA GENERATOR CABLE 9 5 CLAMP 10497-01-000 (3) SCREW G39-08-12U (3) CLAMP 10497-01-000 SCREW G39-08-12U VIEW AA ATS 9 MAIN TO LOAD CENTER POWER CORD 3 UNSPECIFIED TOLERANCES C D 1

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

ALL WIRES DOWN STREAM AND INCLUDING THIS OUTLETARE GROUND FAULT CIRCUIT INTERRUPT PROTECTED.

WIRE ROUTED THRU FLOOR.

WIRE ROUTED IN SIDEWALL.

WIRE ROUTED IN ROOF.

FLEXIBLE CORD TO SLIDEOUT.5

4

30 15 15 20 15 20

LOAD CENTER

ROOF AIRCONDITIONER

RCP-GFIGALLEY 1

GROUNDLUG

1

2

3

8-GRN

4

7

WIRE ROUTED IN BEDROOM OVHD CABINET.6

RCP-2EXTERIOR

RCP-2TRUNK

WATERHEATER 7

LINEPRIMARYSECONDARY

GROUND

NEUTRAL

EMSRELAY

RCP-MICROWAVE

RCP-BLANKGALLEY

RCP-1REFRIGERATOR

14-214-2 14-2

12-2 12-2

RCP-BLANKGALLEY OVHD

RCP-2BATH

2

AUTOMATICTRANSFER

SWITCH7

NOTES:

7 SEE MANUFACTURERS DIAGRAM.

INVERTER

110V CONNECTOR(UNDER GALLEY

CABT)

110V CONNECTOR(UNDER GALLEY CABT)

110VCONNECTOR

(UNDER DINETTE)5 2

THROW IN WIRE #1

BRN-2

3RCP-2

DINETTEOVHD

BLK-2

RCP-CONVERTER

RCP-BLANKROOF

RCP-2SAT PREP

RCP-BLANKBDRM OVHD

6

RCP-BLANKBDRM OVHD

RCP-2BDRM,RH

THROW IN WIRE #4

34

3

RCP-2BDRM,LH

15

110V CONNECTOR(UNDER GALLEY

CABT)

8

WIRE AND RECEPTACLE SUPPLIED INTREGRATEDINTO LOAD CENTER DISTRIBUTION PANEL.

8

BLK

RCP-3AIR

MATTRESS

RCP-2HALL

49M

AIR SLEEP SYSTEM-QUEEN SIZE49M

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

ELECTRICAL SYSTEM 30 AMP

12D2651B1

1B1

265

12DTHROW IN WIRE #5

THROW IN WIRE #2

4

WHT

1BT RCP-MICROWAVE

53B

53B

WATER HEATER, TANKLESS1BT

WTR HTR-6GAL ELECTRIC/LP GAS

GENERATOR

POWERCORD

7 10-2

10-2

10-2

YEL

BLU

BRN

RED

RCP-2FRONT TV

RCP-1LOUNGE

TV

4

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,110V

000181586 / 30147601000 4 OF 420-Sep-2016