ac single point actuatordbroberts.d2pmagazine.com/pdfs/ac.en.pdf · 2015. 3. 9. · tel: (1)...

10
130 Dimensions in millimeters (inch) unless otherwise stated ACTUAL SIZE ACTUAL SIZE Part Number AC-60-101-11 Part Number AC-70-101-11 Cable Orientation Panel Thickness Cable Travel Placement 1 12.5 (.49) max. 11.1 (.44) Placement 2 16 (.63) max. 13.2 (.52) Other options available. For complete details on variety, part numbers, installation and specification, go to Pull direction 45 (1.77) Housing T-handle 60 (2.36) 104.5 (4.11) 117 Open (4.61) 25±0.2 (.98±.008) 40±0.2 (1.57±.008) 4 x Ø 4.5±0.1 (.18±.004) (For thru hole mounting) 56 (2.20) Cable clip 20.8 (.82) 21.7 (.85) 23 (.91) 108.3 (4.26) Panel Panel thickness Cable placement 1 5.7 (.22) 38.3 (1.51) 53.7 (2.11) 28.7 (1.13) 80±0.3 (3.15±.012) 2 x Ø 4.5±0.1 (.177±.004) (For thru hole mounting) 91.6±0.3 (3.61±.012) 5.8±0.1 (.23±.004) 42±0.5 (1.65±.02) 21±0.2 (.83±.008) 4 x R5 (.2) Max. Cable placement 2 Surface mount installation Generous grip area Pull to activate Material and Finish Housing: PC/ABS, black T-handle and slide: Glass-filled nylon, black Clip: acetal, black Spring: Stainless steel, passivated Part Number See table AC Single Point Actuator T-handle AC Single Point Actuator Paddle www.southco.com/AC Front mount installation Flush Two cable mounting options Material and Finish Paddle and housing: 33% glass-filled nylon, black Spring: Stainless steel, passivated Part Number See table

Upload: others

Post on 16-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AC Single Point Actuatordbroberts.d2pmagazine.com/pdfs/AC.en.pdf · 2015. 3. 9. · Tel: (1) 610-459-4000 · Fax: (1) 610-459-4012 · · info@southco.com.OTES For lock core selection,

130

Dimensions in millimeters (inch) unless otherwise stated

ACTUAL SIZE

ACTUAL SIZE

Part Number

AC-60-101-11

Part Number

AC-70-101-11

Cable Orientation Panel Thickness Cable Travel

Placement 1 12.5 (.49) max. 11.1 (.44)

Placement 2 16 (.63) max. 13.2 (.52)

Other options available. For complete details on variety, part numbers, installation and specification, go to

Other options available. For complete details on variety, part numbers, installation and specification, go to

Pull direction

45 (1.77)Housing

T-handle

60 (2.36)

104.5 (4.11)117 Open (4.61)

25±0.2(.98±.008)

40±0.2 (1.57±.008)

4 x Ø 4.5±0.1 (.18±.004)

(For thru hole mounting)

56(2.20)

Cable clip 20.8 (.82)

21.7(.85)

23(.91)

108.3 (4.26) Panel

Panel thickness

Cable placement 1

5.7 (.22)

38.3 (1.51)

53.7(2.11)

28.7(1.13)

80±0.3 (3.15±.012)

2 x Ø 4.5±0.1 (.177±.004)(For thru hole mounting)

91.6±0.3 (3.61±.012)5.8±0.1 (.23±.004)

42±0.5(1.65±.02)

21±0.2(.83±.008)

4 x R5 (.2) Max.

Cable placement 2

Surface mount installation

Generous grip areaPull to activate

Material and FinishHousing: PC/ABS, black T-handle and slide: Glass-filled nylon, black Clip: acetal, black Spring: Stainless steel, passivated Part NumberSee table

AC Single Point ActuatorT-handle

AC Single Point ActuatorPaddle

www.southco.com/AC

Front mount installationFlushTwo cable mounting

options

Material and FinishPaddle and housing: 33% glass-filled nylon, black Spring: Stainless steel, passivated

Part NumberSee table

www.southco.com/AC

Page 2: AC Single Point Actuatordbroberts.d2pmagazine.com/pdfs/AC.en.pdf · 2015. 3. 9. · Tel: (1) 610-459-4000 · Fax: (1) 610-459-4012 · · info@southco.com.OTES For lock core selection,

131

ACTUALSIZE

Part Number

AC-80-101-11

Dimensions in millimeters (inch) unless otherwise stated

Other options available. For complete details on variety, part numbers, installation and specification, go to

Other options available. For complete details on variety, part numbers, installation and specification, go to

Knob Ø 26 (1.02) 6 (.24)

64.6 (2.54)

Door panel

Mounting nut

Housing

26 (1.02)Max. panel thickness

Cam

Ø 32(1.26 )

+1-0

30±0.2 (1.18±.008)

Double-D hole preparation

+.04-0

13.7 (.54) Cable travel

Ø 38 (1.50)

Latch SeriesPart Number

Retainer Clip

R4-10R4-0-43922

R4-30

R4-20R4-0-43922-1

R4-50

Retainer clip

AC Single Point ActuatorPush-button

FlushMounting hardware

included

Material and FinishPush button and housing: PC/ABS, black Cam: 33% glass-filled nylon, black Spring: Stainless steel, passivated

Part NumberSee table

www.southco.com/AC

AC Retainer Clips and Cables

www.southco.com/R4

For use with Ø 4 (.157) rod or Southco cable assembly

Material and FinishSee www.southco.com

Part NumberRetainer clip see table

Cable assembly contact Southco

Page 3: AC Single Point Actuatordbroberts.d2pmagazine.com/pdfs/AC.en.pdf · 2015. 3. 9. · Tel: (1) 610-459-4000 · Fax: (1) 610-459-4012 · · info@southco.com.OTES For lock core selection,

Dimensions in millimeters (inch) unless otherwise stated

AC-10 ActuatorLarge handle Flush mount

Housing, handle, rotating linkage: glass reinforced, nylon, black

Threaded stud and cable bracket retainers: steel, zinc nickel

Housing and handle gaskets: adhesive backed foam, black

Mounting nut (M6 x 1) not supplied. Installation torque of mounting nuts not to exceed 7 N m (62 in-lbf)

For use with Rods / Cables, recommended Snap-in Retainer for Rotator Plate: Southco Part Number R4-0-43922. See Trade Drawing J-R4-0-43922 for more details and options.

(Omit for Locking Options 0, 1, 2, 4, 5 and 9) Keyed Differently (Only used if y=3 or 6) Master Keyed Differently (Only used if y=6)

1 Single Point, Direct Pull 2 Multi-Point, without Cable Bracket 3 Multi-Point, with Cable Bracket

0 Non-Locking 1 Reversible key (No keys - R001) 2 Reversible key (2 keys included - R001) 3 Reversible key (Ten key codes (1 ea.) - 2 keys included) 4 Standard key (No keys - CH751) 5 Standard key (2 keys included - CH751) 6 Standard key (Ten key codes (1 ea.) - 2 keys included) 9 No Lock Plug installed (See notes for more information)

130.1(5.12)

152.4 (6.00)

138.5 (5.45)

190 (7.5)

26 (1.02)

100 (3.9)50 (2.0)86 (3.39)

7 (.28)

34 (1.3)

18.2 (.72)

6 (.23)

4X Ø 7 (.28)

21.5 (.85)

48.9(1.93)

43.5(1.71)

211.3 (8.32)

M6 x 20 (4)

130.1(5.12)

152.4 (6.00)

138.5 (5.45)

190 (7.5)

26 (1.02)

100 (3.9)50 (2.0)86 (3.39)

7 (.28)

34 (1.3)

18.2 (.72)

6 (.23)

4X Ø 7 (.28)

21.5 (.85)

48.9(1.93)

43.5(1.71)

211.3 (8.32)

M6 x 20 (4)

www.southco.com/AC

with Trigger Pull

with Rods

Cables: see AC Cable drawing J-AC-C for cable selection.

Trigger Pull R4-0-51292

For lock core selection, detailed key information and a complete overview of the SOUTHCO® Key-Choice System see PK Lock Cores section.

Page 4: AC Single Point Actuatordbroberts.d2pmagazine.com/pdfs/AC.en.pdf · 2015. 3. 9. · Tel: (1) 610-459-4000 · Fax: (1) 610-459-4012 · · info@southco.com.OTES For lock core selection,

Dimensions in millimeters (inch) unless otherwise stated

AC-15 ActuatorLarge handle Surface mount

Housing, handle, linkage: glass reinforced, nylon, black

Threaded inserts: brass, natural

Housing and handle gaskets: adhesive backed foam, black

Mounting hardware (M6 x 1) not supplied. Recommended screw length=panel thickness + 10.0 (.39) Installation torque of mounting nuts not to exceed 7 N m (62 in-lbf)

218.2 (8.59) 120 (4.7)

M6 thread(mounting location for Trigger Pull)

34(1.3)

55.2(2.17)

83.4(3.28)

120 (4.7)3X Ø 7 (.28)

34 (1.3) 16 (.6)

35 (1.4)

3.8 (.15)

12.5(.49)

38.1(1.50)

90° 29.8(1.17)

2.9 (.11)

64.8(2.55)

105 (4.1)

M6 thread (3)

(Omit for Locking Options 0, 1, 2, 4, 5 and 9)

Keyed Differently (Only used if y=3 or 6) Master Keyed Differently (Only used if y=6)

0 Non-Locking 1 Reversible key (No keys - R001) 2 Reversible key (2 keys included - R001) 3 Reversible key (Ten key codes (1 ea.) - 2 keys included) 4 Standard key (No keys - CH751) 5 Standard key (2 keys included - CH751) 6 Standard key (Ten key codes (1 ea.) - 2 keys included) 9 No Lock Plug installed

www.southco.com/AC

Recommended to use with Trigger Pull

Trigger Pull R4-0-51292

Tel: (1) 610-459-4000 · Fax: (1) 610-459-4012 · www.southco.com · [email protected]

For lock core selection, detailed key information and a complete overview of the SOUTHCO® Key-Choice System see PK Lock Cores section.

For unique key code options, please contact customer service.

Southco® AC 10-15 04-14

Page 5: AC Single Point Actuatordbroberts.d2pmagazine.com/pdfs/AC.en.pdf · 2015. 3. 9. · Tel: (1) 610-459-4000 · Fax: (1) 610-459-4012 · · info@southco.com.OTES For lock core selection,

Dimensions in millimeters (inch) unless otherwise stated

AC - 30 - E L M - H B - KC

ACTUAL SIZE

L Locking Option0 Non Locking1 Reversible key (No keys - R001)2 Reversible key (2 keys included - R001)3 Reversible key (Multiple key codes - 2 keys included)4 Standard key (No keys - CH751)5 Standard key (2 keys included - CH751)6 Standard key (Multiple key codes - 2 keys included)

M Mounting Method1 With spacer mounting (must have if glass panel)2 Without spacer mounting

E End Style1 With Cam attached 3 Without Cam attached

B Button Material1 Nylon with black molding

H Housing Material1 Zinc with black powder coat3 Stainless steel with black powder coat

KC Key Codes (Omit for locking options 1,2,4 and 5)KD10 Keyed differently (10 codes)MK10 Master keyed, keyed differently

Other options available. For complete details on variety, part numbers, installation and specification, go to

Ø 38.3 (1.51)

2 (0.08)

Ø4.1 (0.16)

28 (1.10)

64 (2.52)

Ø32 (1.26)Ø32.3 (1.27) Max

10 (0.39) Cam/Cable Travel2 X Ø5 ±0.1

(0.197 ±0.004)

No Spacer required if panel thickness > 10.3 (0.405)

Panel Thicknessfrom 1 to 22(0.04 to 0.87) Max

Push Travel 12 (0.47)

28 (1.10)

Housing Seal

Spacer

E-Ring

Ø 32 .4 (1.27 )+ 0.2- 0

+ 0.2- 0

29.2 (1.15 )

Panel preparation thickness1 (0.04) to 22 (0.87)

+ 0.2- 0

+ 0.2- 0

Cable Holder

Metal Nut

Tab Washer

42 (1.65)

Push Down 12 (0.47)

Ø 28.8 (1.13)29.1 (1.145) Max

51.4 (2.02)

AC-30 Multi Point ActuatorPush-Button

Single or multi-point actuation capability

Accommodates wide panel thickness

Multiple key code optionsSingle hole install

Material and FinishButton: Nylon Housing: Zinc or Stainless Steel Lock Plug: Zinc Cam, Washer, Rivet: Stainless Steel, Passivated

www.southco.com/AC

Part Number Selection

With cam attachment shown

Without cam attachment shown

Page 6: AC Single Point Actuatordbroberts.d2pmagazine.com/pdfs/AC.en.pdf · 2015. 3. 9. · Tel: (1) 610-459-4000 · Fax: (1) 610-459-4012 · · info@southco.com.OTES For lock core selection,

Dimensions in millimeters (inch) unless otherwise statedOther options available. For complete details on variety, part numbers, installation and specification, go to

© Southco AC-30/40 752NA 05-11

Global Corporate Headquarters and Americas Customer Service & Technical Support Center Tel: (1) 610-459-4000 · Fax: (1) 610-459-4012 · www.southco.com · [email protected]

ACTUAL SIZEACTUAL SIZE

181.4 (7.14)

47 (1.85)

34 (1.34)

Outer SealSpacer

E-Ring

Cable Holder

Metal Nut

Tab Washer

Cam/CableTravel 10 (0.39)

Ø 4.1 (0.16)

51.4 (2.02)

58 (2.28)

34 (1.34)

No Spacer if Panel Thickness > 4.6 (0.18)

Panel Thickness from 1 to 16.8 (0.04 to 0.66) Max.

2 X Ø5 ±0.1

142 ±1 (5.59 ±0.02)

142 ±1 (5.59 ±0.02)

13 ±0.2 (0.51± 0.008)

8.4 ±0.1 (0.33 ±0.004)Ø 32.4 (1.27 ) 29.2 (1.15 ) for Cable Cross Mounting

+ 0.2-0+ 0.2

-0+ 0.2-0

+ 0.2-0

29.2 (1.15 ) for Cable Parallel Mounting+ 0.2-0

+ 0.2-0

Ø44 (1.73)

M8 X 1.25 thread18 depth Min

(Max mounting torque: 40 N·M)12 (0.47) Push Down

36 (1.42)

43

Ø 32 (1.26)Ø 32.3 (1,27)

28.8 (1.13)

181.4 (7.14)

47 (1.85)

34 (1.34)

Outer SealSpacer

E-Ring

Cable Holder

Metal Nut

Tab Washer

Cam/CableTravel 10 (0.39)

Ø 4.1 (0.16)

51.4 (2.02)

58 (2.28)

34 (1.34)

No Spacer if Panel Thickness > 4.6 (0.18)

Panel Thickness from 1 to 16.8 (0.04 to 0.66) Max.

2 X Ø5 ±0.1

142 ±1 (5.59 ±0.02)

142 ±1 (5.59 ±0.02)

13 ±0.2 (0.51± 0.008)

8.4 ±0.1 (0.33 ±0.004)Ø 32.4 (1.27 ) 29.2 (1.15 ) for Cable Cross Mounting

+ 0.2-0+ 0.2

-0+ 0.2-0

+ 0.2-0

29.2 (1.15 ) for Cable Parallel Mounting+ 0.2-0

+ 0.2-0

Ø44 (1.73)

M8 X 1.25 thread18 depth Min

(Max mounting torque: 40 N·M)12 (0.47) Push Down

36 (1.42)

43

Ø 32 (1.26)Ø 32.3 (1,27)

28.8 (1.13)

AC-40 Multi Point ActuatorPush-Button Handle

Single or multi-point actuation capability

Accommodates wide panel thickness

Multiple key code optionsEasy Grip

Material and FinishButton: Nylon Housing: Zinc Die Cast or Stainless Steel Lock Plug: Zinc Die Cast Cam, Washer, Rivet: Stainless Steel, Passivated

www.southco.com/AC

With cam attachment shown

Without cam attachment shown

AC - 40 - E L M - H B - KCL Locking Option

0 Non Locking1 Reversible key (No keys - R001)2 Reversible key (2 keys included - R001)3 Reversible key (Multiple key codes - 2 keys included)4 Standard key (No keys - CH751)5 Standard key (2 keys included - CH751)6 Standard key (Multiple key codes - 2 keys included)

M Mounting Method1 Cable parallel (or no cable), with spacer mounting (must have if glass panel)2 Cable parallel (or no cable), without spacer mounting3 Cable cross with spacer mounting (must have if glass panel)4 Cable cross without spacer mounting

E End Style1 With Cam attached 3 Without Cam attached

B Button Material1 Nylon with black molding

H Handle Material1 Black GF nylon with zinc housing insert2 Black GF nylon with stainless steel housing insert

Part Number Selection

KC Key Codes (Omit for locking options 1,2,4 and 5)KD10 Keyed differently (10 codes)MK10 Master keyed, keyed differently

Page 7: AC Single Point Actuatordbroberts.d2pmagazine.com/pdfs/AC.en.pdf · 2015. 3. 9. · Tel: (1) 610-459-4000 · Fax: (1) 610-459-4012 · · info@southco.com.OTES For lock core selection,

Dimensions in millimeters (inch) unless otherwise stated

Global Corporate Headquarters and Americas Customer Service & Technical Support Center Tel: (1) 610-459-4000 · Fax: (1) 610-459-4012 · www.southco.com · [email protected]

Other options available. For complete details on variety, part numbers, installation and specification, go to

AC-50 Single Point ActuatorSqueeze handle

www.southco.com/AC

Part Number

AC-50-101-11

Squeeze Handle

Panel Preparation

161.4(6.35)

4.5(.18)

15.2(.6) 21.7

(.85)

129.5(5.1)141.4(5.57)

18(.71)

6.7(.26)

44(1.73)

28.2(1.11)

R 13.4(.53) 20

(.8)

2X M5 Thread

Use Southco cable end fitting type B (L type)(Cable sold separately. Refer to Southco drawingJ-AC-C for Cable Selection Guide.)

Squeeze handleassembly

Customer installation tube

169.2(6.66)

28.2(1.11)

20(.79)

R 13.4(.53)

44(1.73)

4.5(.18)

13 (.51) Handle travel

12 (.47) Cable travelRetaining

clip included

Pull Direction

Use Southco cable end fitting type B (L type)(Cable sold separately. Refer to Southco drawingJ-AC-C for Cable Selection Guide.)

Squeeze handleassembly

Customer installation tube

169.2(6.66)

28.2(1.11)

20(.79)

R 13.4(.53)

44(1.73)

4.5(.18)

13 (.51) Handle travel

12 (.47) Cable travelRetaining

clip included

Pull Direction

Single actuation capability Accomodates tubular construction or rounded mounting surfaces

Material and FinishHousing, handle: Glass-filled nylon, black

Installation NotesInstallation torque of screws

(Countersunk screws or rivets recommended)

Page 8: AC Single Point Actuatordbroberts.d2pmagazine.com/pdfs/AC.en.pdf · 2015. 3. 9. · Tel: (1) 610-459-4000 · Fax: (1) 610-459-4012 · · info@southco.com.OTES For lock core selection,

Dimensions in millimeters (inch) unless otherwise stated

ACTUAL SIZE

Part Number

AC-75-101-11

Cable Orientation Panel Thickness Cable Travel

Placement 1 12.5 (.49) max. 11.1 (.44)

Placement 2 16 (.63) max. 13.2 (.52)

Placement 3 16 (.63) max. 13.2 (.52)

Other options available. For complete details on variety, part numbers, installation and specification, go to

© Southco AC-75 743NA 05-11

Global Corporate Headquarters and Americas Customer Service & Technical Support CenterTel: (1) 610-459-4000 · Fax: (1) 610-459-4012 · www.southco.com · [email protected]

49.2 (1.94)13 (0.51)

96.2 (3.78)

37.1 (1.46)

37.1 (1.19)

Cable Placement 3

Cable Placement 2

Cable Placement 1

81 (3.2)

37.9 (1.49)

18.9 (0.74)

4X R5 Max

Door

2X Ø 4.5 ±0.1(.177±.004)(For thur hole mounting)

73 (2.87)

4 ±0.1 (0.15 ±0.003)

35.2 (1.38)

49.2 (1.94)13 (0.51)

96.2 (3.78)

37.1 (1.46)

37.1 (1.19)

Cable Placement 3

Cable Placement 2

Cable Placement 1

81 (3.2)

37.9 (1.49)

18.9 (0.74)

4X R5 Max

Door

2X Ø 4.5 ±0.1(.177±.004)(For thur hole mounting)

73 (2.87)

4 ±0.1 (0.15 ±0.003)

35.2 (1.38)

AC-75 Single Point ActuatorPaddle

• Front mount installation• Flush• Three cable mounting options

Material and FinishPaddle and housing: Aluminum, black powder coated

Part NumberSee table

www.southco.com/AC

Page 9: AC Single Point Actuatordbroberts.d2pmagazine.com/pdfs/AC.en.pdf · 2015. 3. 9. · Tel: (1) 610-459-4000 · Fax: (1) 610-459-4012 · · info@southco.com.OTES For lock core selection,

Dimensions in millimeters (inch) unless otherwise stated

Other options available. For complete details on variety, part numbers, installation and specification, go to

CablesConstructed from marine grade stainless materials, the cable is suitable for multiple bends and can be further customised upon request, Contact Southco Marine for details. An in-built spring prevents uninten-tional actuation by boat vibration.

“L” - 65.2mm (2.57)

Actuator End (Option J shown) Latch EndOptional spring to ensure cable reset)

“L”

48mm (1.89)

AC - C K - 3 - - 048

L Length in mm e.g. 0610 = 610 mm = 2’

A Actuator fitting J Stainless barrel fitting to suit push-button and paddle actuators K Stainless “L” fitting to suit R4 latch and AC-M1 actuators

S Spring option 0 No Spring 1 With Spring (latch end only)

LLLLA S

38mm (1 1/2") version 50mm (2") version

AC Cables

50mm (2”) version

38mm (1 1/2”) version: (suits 9mm (3/8") or 12mm (1/2") panels):

AC - M1 - - 8

L Lock style 4 Locking (2 keys supplied) 6 Non-locking 7 Key-locking keyed alike S008 (2 overmoulded keys supplied (only available for 50mm 2” version)

P Panel thickness 2 9mm (3/8”) 3 12mm (1/2”)AC - M1 - 15 - 1 - 8L

L P

• Single, round-hole installation• Locking style restricts access• Premium finish and

corrosion resistance

Material and FinishLatch: 316 grade stainless steel and bright polished Spacer: Nylon, black Contact Southco for other finishes

Performance DetailsMax. static load: 545 N (122 lbf)

Accessories (Small)One key supplied per latch for additional keys order M7-88-9121324-S

Keeper: M1-510-19-8

Mounting screws: M1-510-96-4

Accessories (Large)Keeper Part number: M1-519-4

For lock style 4 Key (pair) Part number: M1-546

For lock style 7 Overmolded key S008 (pair) Part number: M1-525-39-S008

Door thickness (See table)

Actuator Assembly(See table)

Link Retainer (Sold separate)R4-0-43922-2

Small Ø38.1 ±0.5(1.5 ±.02)Large Ø50(2.0 )+ .05

- 0

+ 1.2- 0

Mounting Bracket

Ø 47 (1.85)

Cable travel 13 (.51)

Cable travel 13 (.51)

Cable retainer (Sold separate)See table (1/8” Mounting screw not included)

M5 Phillips Recess (No.2)Pan Head Mounting Screws

Cable Retainer (Sold separate) See table(1/8” Mounting Screws not included)

Ø 61 (2.40)

2.5 (.98) Small 38mm Version3.0 (1.2) Large 50mm Version

Door thickness (See table)

34(1.3)

34(1.3)

Door

Door

3 (1.2)Door thickness (See table)

Cable retainer (Sold separate)See table (1/8” Mounting screw not included)

Door thickness (See table)

Actuator Assembly(See table)

Link Retainer (Sold separate)R4-0-43922-2

Small Ø38.1 ±0.5(1.5 ±.02)Large Ø50(2.0 )+ .05

- 0

+ 1.2- 0

Mounting Bracket

Ø 47 (1.85)

Cable travel 13 (.51)

Cable travel 13 (.51)

Cable retainer (Sold separate)See table (1/8” Mounting screw not included)

M5 Phillips Recess (No.2)Pan Head Mounting Screws

Cable Retainer (Sold separate) See table(1/8” Mounting Screws not included)

Ø 61 (2.40)

2.5 (.98) Small 38mm Version3.0 (1.2) Large 50mm Version

Door thickness (See table)

34(1.3)

34(1.3)

Door

Door

3 (1.2)Door thickness (See table)

Cable retainer (Sold separate)See table (1/8” Mounting screw not included)

Door thickness (See table)

Actuator Assembly(See table)

Link Retainer (Sold separate)R4-0-43922-2

Small Ø38.1 ±0.5(1.5 ±.02)Large Ø50(2.0 )+ .05

- 0

+ 1.2- 0

Mounting Bracket

Ø 47 (1.85)

Cable travel 13 (.51)

Cable travel 13 (.51)

Cable retainer (Sold separate)See table (1/8” Mounting screw not included)

M5 Phillips Recess (No.2)Pan Head Mounting Screws

Cable Retainer (Sold separate) See table(1/8” Mounting Screws not included)

Ø 61 (2.40)

2.5 (.98) Small 38mm Version3.0 (1.2) Large 50mm Version

Door thickness (See table)

34(1.3)

34(1.3)

Door

Door

3 (1.2)Door thickness (See table)

Cable retainer (Sold separate)See table (1/8” Mounting screw not included)

www.southco.com/R4

AC Single Point ActuatorsStainless Steel · M1 Style Actuator

Page 10: AC Single Point Actuatordbroberts.d2pmagazine.com/pdfs/AC.en.pdf · 2015. 3. 9. · Tel: (1) 610-459-4000 · Fax: (1) 610-459-4012 · · info@southco.com.OTES For lock core selection,

Dimensions in millimeters (inch) unless otherwise statedOther options available. For complete details on variety, part numbers, installation and specification, go to

ACTUAL SIZE

Striker Bolt Part Number

R4-90-121-20

26 (1.02)

40 (1.57)10 (0.39)

14 (0.55)

14 (0.55)

8 (0.31)

12.7 (.50) Hex

Ø 25.4 (1.00)

Ø 9.5(.37)

Washer

O-Ring

M8 x 1.25 thread

38.1 (1.50)

27.7(1.09)25.4

(1.00)

2.8 (.11)

Striker bolt

22.5±0.1(.89±.004)

26 (1.02) Min.

3.5±0.05 (.14±.002)

9 (.35) Max.

5 (.20) Min.

2 x

Latched position Unlatched position

Retainer clip (sold separately) Secures cable to AC-M1 actuator Part Number: R4-0-43922-2

Striker 90° Mounting Bracket (sold separately)

Part Number: R4-0-50114

Part Number A Panel thickness

R4-0-50253-1 28mm (1.10) 9mm (0.35)

R4-0-50253-2 31mm (1.22) 12mm (0.47)

6.6(0.26)

28 (1.10)

12 (0.47)

4.5(0.18)

Ø4(Ø 0.16)

A”

Cable Mounting Bracket (sold separately). For use with AC-M1 actuators

© Southco R4SS 722NA 02-11

Global Corporate Headquarters and Americas Customer Service & Technical Support CenterTel: (1) 610-459-4000 · Fax: (1) 610-459-4012 · www.southco.com · [email protected]/R4

R4 Push-to-Close LatchStriker bolt · Stainless Steel · Mini · Installation

Striker Bolt Assembly (sold separately)

Panel Preperation

• Striker bolt for R4-10 series rotary latch

Material and Finish304 Stainless Steel

Part NumberSee table

Operation

To request a quote,please email