    Twice the Capacity o AC

    30-40% Reduction in L

    Proven Reliability World

    The Worlds Most Efcient High Capacity Transmission Co

    ACCC

  • 7/28/2019 ACCC Brochure

    2/2

    Assumptions: 100 km (62 mile) 230 kV line; Drake Equivalent Conductors; 53% Load Factor; 30 C Ambient; 2 fps Wind; .5 Emissivity; .5 Abs$50/MWh; $1MM/MW; Coal Fired (2.19#/kWh); CO2 $25/MT

    The Economics o Efc

    ACCCThe Worlds Most Efcient High Capacity Transmission Conductor

    CTC Global a privately held corporation headquartered in Irvine,Caliornia promotes efciency, increased capacity and improved

    reliability o both new and existing transmission systems. CTC Globals

    principle business is the manuacture and sale o the ACCC core

    used in the production o ACCC conductor. The company also

    provides ancillary components such as dead-ends and splices,

    and provides engineering, installation and warranty support or all o its products.

    All components produced by CTC and its stranding partners are certifed to ISO

    9001-2008 Standards.

    CTC Global produces fnished conductor in association with a growing team

    o qualifed regional stranding partners. ACCC core is produced, tested and

    certifed at CTC Global and then stranded with trapezoidal shaped aluminum

    by qualifed ACCC conductor licensees who then ship the fnished conductor to

    customers worldwide.

    Increase Capacity without Compromise

    The ACCC conductor oers industry-leading capacity

    and efciency through any range o operating temperatures

    compared to any other conductor type o the same

    diameter and weight. The ACCC conductors high strength

    and low thermal sag provides planners and engineers

    an efcient means o increasing capacity - and improving

    efciency and reliability - without compromising

    structural integrity or sae ground clearances.

    Maximize Efciency and Returns

    Increased capacity and a 30% to 40% reduction in

    line losses under any load condition improve fnancial

    returns year ater year over the lie o the asset. The

    ACCC conductor operates cooler than any other overhead

    conductor under any load condition, delivering morepower more efciently with greater pay back.

    Improve Reliability & Compliance

    The ACCC conductors combination o superior strength,

    high capacity and low thermal sag make it uniquely

    suited or addressing issues o reliability and regulatory

    compliance providing utilities with an eective and

    economical solution or thermally constrained lines.

    CTC Global Technical Support

    CTC Globals support sta stands ready to provide project

    development, design, and installation assistance. The

    ACCC conductor can be analyzed using any commercially

    available line design program such as PLS CADD,

    Sag 10, or CTC Globals own Conductor Comparison &

    Line Optimization Program (CCP). Please contact

    [email protected]

    PeakAmps

    Temperature atpeak amps (C)

    L oad Factor MVAAnnual Line

    Losses (MWh)

    GenerationCapacity to Supply

    Losses (MW)

    Value o Reductionat $1 million/MW

    ACSR 1,000 95 53% 398 76,917 30.35 ---- --

    ACCC 1,000 82 53% 398 56,588 22.33 $8,020,000 $26

    ACSS 1,600 194 53% 637 251,998 99.43 ---- --

    ACCC 1,600 156 53% 637 179,022 70.63 $28,800,000 $96

    VaGene

    (m

    Value o Generation Capacity Savings

    PeakAmps

    Line Loss

    Reduction(MWh)

    C02 Reductions(Metric Tons)

    SOx Reductions(Metric Tons)

    NOx Reductions(Metric Tons)

    ACSR 1,000 53% 398 ---- ---- ---- ---- --

    ACCC 1,000 53% 398 20,329 63,513 290 98.6 $5

    ACSS 1,600 53% 637 ---- ---- ---- ---- --

    ACCC 1,600 53% 637 72,976 250,572 1144 389 $20

    Value

    per (m

    Value o Emission Reductions

    MVALoad Factor

    PeakAmps MVA

    Annual LineLosses (MWh)

    Line LossReduction

    Value o Reduction(at $50/MWh)

    ACSR 1,000 95 53% 398 76,917 ---- ---- --

    ACCC 1,000 82 53% 398 56,588 20,329 $1,016,450 $3

    ACSS 1,600 194 53% 637 251,998 ---- ---- --

    ACCC 1,600 156 53% 637 179,022 72,976 $3,648,800 $12

    Valuper l(me

    Value o Line Loss Reductions

    Temperature atpeak amps (C) Load Factor