accc®-uls monte carlo - ctc global · 2019-01-22 · *accc® conductor is produced with 1350...

26
DATA SHEET: Governing Units: Metric Mechanical Specifications Nominal Aluminum Cross-sectional Area* 228.5 mm 2 450.9 kcmil Nominal Diameter of Composite Core (CTC Part Number 210-011) 10.54 mm 0.415 in. Nominal Cross-sectional Area of Core 87.3 mm 2 0.135 in 2 Overall Diameter of Conductor 20.78 mm 0.818 in. Nominal Cross-sectional Area of the Conductor 315.8 mm 2 0.489 in 2 Ultimate Tensile Strength of Conductor 1,2 238.5 kN 53.6 kips Rated Strength of Core - 375 ksi (2586 MPa) 225.6 kN 50.7 kips Core Nominal Mass per unit length 157 kg/km 106 lb/kft Conductor Nominal Mass per unit length 791.8 kg/km 532.2 lb/kft Aluminum Nominal Mass per unit length** 634.8 kg/km 426.7 lb/kft Maximum Allowable Operating Temperature at Surface 4 180 o C 356 o F Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 / o C 4.17E-07 / o F Coefficient of Linear Expansion Below Thermal Kneepoint 1.21E-05 / o C 6.72E-06 / o F Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi Final Modulus of Elasticity Below Thermal Kneepoint 82.5 GPa 12.0 Msi Electrical Specifications Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.1230 ohm/km 0.1979 ohm/mile Temperature Coefficient of Resistance 0.00403 0.00403 Frequency 50 Hz 60 Hz AC Nominal Resistance at 25ºC 0.1257 ohm/km 0.2024 ohm/mile AC Nominal Resistance at 75ºC 0.1504 ohm/km 0.2422 ohm/mile AC Nominal Resistance at 180ºC 0.2024 ohm/km 0.3258 ohm/mile 691 @ 100C & 50 Hz 1027 @ 180C & 50 Hz GMR (estimated) 0.009 m 0.029 ft Inductive Reactance 0.222 ohm/km 0.429 ohm/mile Capacitive Reactance 0.194 Mohm-km 0.100 Mohm-mile 1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540. 2) Strength at ambient temperature F-730-140-E ACCC-TW ULS 229 (451 kcmil) Monte Carlo Data Sheet www.ctcglobal.com Date Produced: 7/10/2015 Metric Imperial AC Current Rating at Given Temperature 3 The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec sheet, with the weight and cross sectional area being no more than ±2% of the value indicated. **ACCC ® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540. 3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation 4) Maximum continuous operating temperature of ACCC ® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor). *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2 kcmil) ACCC®-ULS Monte Carlo NOT RELEASED For questions, please contact CTC Application Engineering Department: [email protected] Metric Imperial

Upload: others

Post on 18-Apr-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 228.5 mm2 450.9 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-011) 10.54 mm 0.415 in.

Nominal Cross-sectional Area of Core 87.3 mm2 0.135 in

2

Overall Diameter of Conductor 20.78 mm 0.818 in.

Nominal Cross-sectional Area of the Conductor 315.8 mm2 0.489 in

2

Ultimate Tensile Strength of Conductor1,2 238.5 kN 53.6 kips

Rated Strength of Core - 375 ksi (2586 MPa) 225.6 kN 50.7 kips

Core Nominal Mass per unit length 157 kg/km 106 lb/kft

Conductor Nominal Mass per unit length 791.8 kg/km 532.2 lb/kft

Aluminum Nominal Mass per unit length** 634.8 kg/km 426.7 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.21E-05 /oC 6.72E-06 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 82.5 GPa 12.0 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.1230 ohm/km 0.1979 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.1257 ohm/km 0.2024 ohm/mile

AC Nominal Resistance at 75ºC 0.1504 ohm/km 0.2422 ohm/mile

AC Nominal Resistance at 180ºC 0.2024 ohm/km 0.3258 ohm/mile

691 @ 100C & 50 Hz

1027 @ 180C & 50 Hz

GMR (estimated) 0.009 m 0.029 ft

Inductive Reactance 0.222 ohm/km 0.429 ohm/mile

Capacitive Reactance 0.194 Mohm-km 0.100 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-140-E ACCC-TW ULS 229 (451 kcmil) Monte Carlo Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2 kcmil)

ACCC®-ULS Monte Carlo

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 2: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 313.8 mm2 619.3 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-008) 8.76 mm 0.345 in.

Nominal Cross-sectional Area of Core 60.3 mm2 0.093 in

2

Overall Diameter of Conductor 22.40 mm 0.882 in.

Nominal Cross-sectional Area of the Conductor 374.1 mm2 0.580 in

2

Ultimate Tensile Strength of Conductor1,2 173.6 kN 39.0 kips

Rated Strength of Core - 375 ksi (2586 MPa) 155.9 kN 35.1 kips

Core Nominal Mass per unit length 109 kg/km 73 lb/kft

Conductor Nominal Mass per unit length 976.7 kg/km 656.4 lb/kft

Aluminum Nominal Mass per unit length** 867.7 kg/km 583.1 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.57E-05 /oC 8.75E-06 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 72.3 GPa 10.5 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0893 ohm/km 0.1437 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0915 ohm/km 0.1476 ohm/mile

AC Nominal Resistance at 75ºC 0.1095 ohm/km 0.1764 ohm/mile

AC Nominal Resistance at 180ºC 0.1471 ohm/km 0.2369 ohm/mile

827 @ 100C & 50 Hz

1233 @ 180C & 50 Hz

GMR (estimated) 0.009 m 0.030 ft

Inductive Reactance 0.220 ohm/km 0.424 ohm/mile

Capacitive Reactance 0.189 Mohm-km 0.098 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-152-E ACCC-TW ULS 314 (619 kcmil) Oslo Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 323 sq. mm (637.5 kcmil)

ACCC®-ULS Oslo

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 3: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 383.2 mm2 756.2 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-011) 10.54 mm 0.415 in.

Nominal Cross-sectional Area of Core 87.3 mm2 0.135 in

2

Overall Diameter of Conductor 25.00 mm 0.984 in.

Nominal Cross-sectional Area of the Conductor 470.5 mm2 0.729 in

2

Ultimate Tensile Strength of Conductor1,2 247.2 kN 55.6 kips

Rated Strength of Core - 375 ksi (2586 MPa) 225.6 kN 50.7 kips

Core Nominal Mass per unit length 157 kg/km 106 lb/kft

Conductor Nominal Mass per unit length 1216.0 kg/km 817.3 lb/kft

Aluminum Nominal Mass per unit length** 1059.0 kg/km 711.8 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.49E-05 /oC 8.27E-06 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 74.5 GPa 10.8 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0730 ohm/km 0.1175 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0750 ohm/km 0.1210 ohm/mile

AC Nominal Resistance at 75ºC 0.0896 ohm/km 0.1445 ohm/mile

AC Nominal Resistance at 180ºC 0.1203 ohm/km 0.1938 ohm/mile

943 @ 100C & 50 Hz

1412 @ 180C & 50 Hz

GMR (estimated) 0.010 m 0.034 ft

Inductive Reactance 0.212 ohm/km 0.410 ohm/mile

Capacitive Reactance 0.183 Mohm-km 0.095 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-150-E ACCC-TW ULS 383 (756 kcmil) 25 mm Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 394.5 sq. mm (778.5 kcmil)

ACCC®-ULS 25 mm

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 4: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 406.4 mm2 802.0 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-007) 9.53 mm 0.375 in.

Nominal Cross-sectional Area of Core 71.3 mm2 0.111 in

2

Overall Diameter of Conductor 25.14 mm 0.990 in.

Nominal Cross-sectional Area of the Conductor 477.7 mm2 0.740 in

2

Ultimate Tensile Strength of Conductor1,2 207.1 kN 46.6 kips

Rated Strength of Core - 375 ksi (2586 MPa) 184.2 kN 41.4 kips

Core Nominal Mass per unit length 128 kg/km 86 lb/kft

Conductor Nominal Mass per unit length 1253.1 kg/km 842.2 lb/kft

Aluminum Nominal Mass per unit length** 1125.1 kg/km 756.1 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.62E-05 /oC 8.99E-06 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 71.2 GPa 10.3 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0690 ohm/km 0.1110 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0710 ohm/km 0.1147 ohm/mile

AC Nominal Resistance at 75ºC 0.0848 ohm/km 0.1368 ohm/mile

AC Nominal Resistance at 180ºC 0.1138 ohm/km 0.1833 ohm/mile

971 @ 100C & 50 Hz

1454 @ 180C & 50 Hz

GMR (estimated) 0.010 m 0.034 ft

Inductive Reactance 0.213 ohm/km 0.411 ohm/mile

Capacitive Reactance 0.183 Mohm-km 0.095 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-154-E ACCC-TW ULS 406 (802 kcmil) Leipzig Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 418.4 sq. mm (825.6 kcmil)

ACCC®-ULS Leipzig

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 5: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 453.7 mm2 895.4 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-008) 8.76 mm 0.345 in.

Nominal Cross-sectional Area of Core 60.3 mm2 0.093 in

2

Overall Diameter of Conductor 26.40 mm 1.039 in.

Nominal Cross-sectional Area of the Conductor 514.0 mm2 0.797 in

2

Ultimate Tensile Strength of Conductor1,2 181.4 kN 40.8 kips

Rated Strength of Core - 375 ksi (2586 MPa) 155.9 kN 35.1 kips

Core Nominal Mass per unit length 109 kg/km 73 lb/kft

Conductor Nominal Mass per unit length 1363.8 kg/km 916.6 lb/kft

Aluminum Nominal Mass per unit length** 1254.8 kg/km 843.4 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.74E-05 /oC 9.68E-06 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 68.4 GPa 9.9 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0617 ohm/km 0.0993 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0637 ohm/km 0.1031 ohm/mile

AC Nominal Resistance at 75ºC 0.0760 ohm/km 0.1228 ohm/mile

AC Nominal Resistance at 180ºC 0.1019 ohm/km 0.1642 ohm/mile

1039 @ 100C & 50 Hz

1560 @ 180C & 50 Hz

GMR (estimated) 0.011 m 0.035 ft

Inductive Reactance 0.210 ohm/km 0.406 ohm/mile

Capacitive Reactance 0.180 Mohm-km 0.093 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-155-E ACCC-TW ULS 454 (895 kcmil) Stockholm 3L Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 467 sq. mm (921.7 kcmil)

ACCC®-ULS Stockholm 3L

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 6: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 463.3 mm2 914.3 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-008) 8.76 mm 0.345 in.

Nominal Cross-sectional Area of Core 60.3 mm2 0.093 in

2

Overall Diameter of Conductor 26.40 mm 1.039 in.

Nominal Cross-sectional Area of the Conductor 523.6 mm2 0.812 in

2

Ultimate Tensile Strength of Conductor1,2 182.0 kN 40.9 kips

Rated Strength of Core - 375 ksi (2586 MPa) 155.9 kN 35.1 kips

Core Nominal Mass per unit length 109 kg/km 73 lb/kft

Conductor Nominal Mass per unit length 1390.6 kg/km 934.6 lb/kft

Aluminum Nominal Mass per unit length** 1281.6 kg/km 861.3 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.75E-05 /oC 9.73E-06 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 68.2 GPa 9.9 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0605 ohm/km 0.0974 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0625 ohm/km 0.1011 ohm/mile

AC Nominal Resistance at 75ºC 0.0746 ohm/km 0.1205 ohm/mile

AC Nominal Resistance at 180ºC 0.0999 ohm/km 0.1610 ohm/mile

1049 @ 100C & 50 Hz

1576 @ 180C & 50 Hz

GMR (estimated) 0.011 m 0.035 ft

Inductive Reactance 0.210 ohm/km 0.406 ohm/mile

Capacitive Reactance 0.180 Mohm-km 0.093 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-156-E ACCC-TW ULS 463 (914 kcmil) Stockholm 2L Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 476.9 sq. mm (941.2 kcmil)

ACCC®-ULS Stockholm 2L

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 7: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 507.5 mm2 1001.5 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-008) 8.76 mm 0.345 in.

Nominal Cross-sectional Area of Core 60.3 mm2 0.093 in

2

Overall Diameter of Conductor 27.72 mm 1.091 in.

Nominal Cross-sectional Area of the Conductor 567.8 mm2 0.880 in

2

Ultimate Tensile Strength of Conductor1,2 184.4 kN 41.5 kips

Rated Strength of Core - 375 ksi (2586 MPa) 155.9 kN 35.1 kips

Core Nominal Mass per unit length 109 kg/km 73 lb/kft

Conductor Nominal Mass per unit length 1515.3 kg/km 1018.4 lb/kft

Aluminum Nominal Mass per unit length** 1406.3 kg/km 945.2 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.79E-05 /oC 9.94E-06 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 67.4 GPa 9.8 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0553 ohm/km 0.0890 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0573 ohm/km 0.0928 ohm/mile

AC Nominal Resistance at 75ºC 0.0683 ohm/km 0.1104 ohm/mile

AC Nominal Resistance at 180ºC 0.0914 ohm/km 0.1474 ohm/mile

1112 @ 100C & 50 Hz

1673 @ 180C & 50 Hz

GMR (estimated) 0.011 m 0.037 ft

Inductive Reactance 0.207 ohm/km 0.401 ohm/mile

Capacitive Reactance 0.177 Mohm-km 0.092 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-195-E ACCC-TW ULS 508 (1002 kcmil) Warsaw Data Sheet www.ctcglobal.com Date Produced: 7/14/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 522.4 sq. mm (1031 kcmil)

ACCC®-ULS Warsaw

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 8: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 524.5 mm2 1035.1 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-007) 9.53 mm 0.375 in.

Nominal Cross-sectional Area of Core 71.3 mm2 0.111 in

2

Overall Diameter of Conductor 28.14 mm 1.108 in.

Nominal Cross-sectional Area of the Conductor 595.8 mm2 0.923 in

2

Ultimate Tensile Strength of Conductor1,2 213.7 kN 48.0 kips

Rated Strength of Core - 375 ksi (2586 MPa) 184.2 kN 41.4 kips

Core Nominal Mass per unit length 128 kg/km 86 lb/kft

Conductor Nominal Mass per unit length 1579.2 kg/km 1061.3 lb/kft

Aluminum Nominal Mass per unit length** 1451.2 kg/km 975.3 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.73E-05 /oC 9.63E-06 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 68.6 GPa 10.0 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0534 ohm/km 0.0859 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0553 ohm/km 0.0897 ohm/mile

AC Nominal Resistance at 75ºC 0.0660 ohm/km 0.1067 ohm/mile

AC Nominal Resistance at 180ºC 0.0883 ohm/km 0.1423 ohm/mile

1136 @ 100C & 50 Hz

1711 @ 180C & 50 Hz

GMR (estimated) 0.011 m 0.038 ft

Inductive Reactance 0.206 ohm/km 0.398 ohm/mile

Capacitive Reactance 0.176 Mohm-km 0.091 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-157-E ACCC-TW ULS 525 (1035 kcmil) Dublin Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 539.9 sq. mm (1065.5 kcmil)

ACCC®-ULS Dublin

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 9: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 543.5 mm2 1072.6 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-007) 9.53 mm 0.375 in.

Nominal Cross-sectional Area of Core 71.3 mm2 0.111 in

2

Overall Diameter of Conductor 28.62 mm 1.127 in.

Nominal Cross-sectional Area of the Conductor 614.8 mm2 0.953 in

2

Ultimate Tensile Strength of Conductor1,2 214.8 kN 48.3 kips

Rated Strength of Core - 375 ksi (2586 MPa) 184.2 kN 41.4 kips

Core Nominal Mass per unit length 128 kg/km 86 lb/kft

Conductor Nominal Mass per unit length 1638.9 kg/km 1101.5 lb/kft

Aluminum Nominal Mass per unit length** 1510.9 kg/km 1015.5 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.75E-05 /oC 9.72E-06 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 68.3 GPa 9.9 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0517 ohm/km 0.0832 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0536 ohm/km 0.0870 ohm/mile

AC Nominal Resistance at 75ºC 0.0639 ohm/km 0.1034 ohm/mile

AC Nominal Resistance at 180ºC 0.0855 ohm/km 0.1378 ohm/mile

1160 @ 100C & 50 Hz

1748 @ 180C & 50 Hz

GMR (estimated) 0.012 m 0.038 ft

Inductive Reactance 0.205 ohm/km 0.396 ohm/mile

Capacitive Reactance 0.175 Mohm-km 0.091 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-194-E ACCC-TW ULS 544 (1073 kcmil) Kolkata Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 559.5 sq. mm (1104.1 kcmil)

ACCC®-ULS Kolkata

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 10: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 544.9 mm2 1075.3 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-011) 10.54 mm 0.415 in.

Nominal Cross-sectional Area of Core 87.3 mm2 0.135 in

2

Overall Diameter of Conductor 29.00 mm 1.142 in.

Nominal Cross-sectional Area of the Conductor 632.2 mm2 0.980 in

2

Ultimate Tensile Strength of Conductor1,2 256.3 kN 57.6 kips

Rated Strength of Core - 375 ksi (2586 MPa) 225.6 kN 50.7 kips

Core Nominal Mass per unit length 157 kg/km 106 lb/kft

Conductor Nominal Mass per unit length 1663.0 kg/km 1117.7 lb/kft

Aluminum Nominal Mass per unit length** 1506.0 kg/km 1012.2 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.66E-05 /oC 9.23E-06 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 70.3 GPa 10.2 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0514 ohm/km 0.0827 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0536 ohm/km 0.0863 ohm/mile

AC Nominal Resistance at 75ºC 0.0638 ohm/km 0.1027 ohm/mile

AC Nominal Resistance at 180ºC 0.0852 ohm/km 0.1370 ohm/mile

1165 @ 100C & 50 Hz

1758 @ 180C & 50 Hz

GMR (estimated) 0.012 m 0.039 ft

Inductive Reactance 0.204 ohm/km 0.394 ohm/mile

Capacitive Reactance 0.174 Mohm-km 0.090 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-141-E ACCC-TW ULS 545 (1075 kcmil) Mahakam Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 560.9 sq. mm (1107 kcmil)

ACCC®-ULS Mahakam

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 11: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 546.4 mm2 1078.3 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-008) 8.76 mm 0.345 in.

Nominal Cross-sectional Area of Core 60.3 mm2 0.093 in

2

Overall Diameter of Conductor 28.62 mm 1.127 in.

Nominal Cross-sectional Area of the Conductor 606.7 mm2 0.940 in

2

Ultimate Tensile Strength of Conductor1,2 186.6 kN 41.9 kips

Rated Strength of Core - 375 ksi (2586 MPa) 155.9 kN 35.1 kips

Core Nominal Mass per unit length 109 kg/km 73 lb/kft

Conductor Nominal Mass per unit length 1622.8 kg/km 1090.7 lb/kft

Aluminum Nominal Mass per unit length** 1513.8 kg/km 1017.4 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.82E-05 /oC 1.01E-05 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 66.8 GPa 9.7 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0514 ohm/km 0.0827 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0534 ohm/km 0.0866 ohm/mile

AC Nominal Resistance at 75ºC 0.0636 ohm/km 0.1030 ohm/mile

AC Nominal Resistance at 180ºC 0.0850 ohm/km 0.1372 ohm/mile

1163 @ 100C & 50 Hz

1752 @ 180C & 50 Hz

GMR (estimated) 0.012 m 0.038 ft

Inductive Reactance 0.206 ohm/km 0.397 ohm/mile

Capacitive Reactance 0.175 Mohm-km 0.091 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-158-E ACCC-TW ULS 546 (1078 kcmil) Hamburg Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 562.5 sq. mm (1110 kcmil)

ACCC®-ULS Hamburg

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 12: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 567.7 mm2 1120.3 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-008) 8.76 mm 0.345 in.

Nominal Cross-sectional Area of Core 60.3 mm2 0.093 in

2

Overall Diameter of Conductor 29.10 mm 1.146 in.

Nominal Cross-sectional Area of the Conductor 628.0 mm2 0.973 in

2

Ultimate Tensile Strength of Conductor1,2 187.8 kN 42.2 kips

Rated Strength of Core - 375 ksi (2586 MPa) 155.9 kN 35.1 kips

Core Nominal Mass per unit length 109 kg/km 73 lb/kft

Conductor Nominal Mass per unit length 1681.6 kg/km 1130.2 lb/kft

Aluminum Nominal Mass per unit length** 1572.6 kg/km 1056.9 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.83E-05 /oC 1.02E-05 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 66.5 GPa 9.6 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0494 ohm/km 0.0795 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0514 ohm/km 0.0835 ohm/mile

AC Nominal Resistance at 75ºC 0.0612 ohm/km 0.0991 ohm/mile

AC Nominal Resistance at 180ºC 0.0818 ohm/km 0.1320 ohm/mile

1191 @ 100C & 50 Hz

1797 @ 180C & 50 Hz

GMR (estimated) 0.012 m 0.039 ft

Inductive Reactance 0.205 ohm/km 0.395 ohm/mile

Capacitive Reactance 0.174 Mohm-km 0.090 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-159-E ACCC-TW ULS 568 (1120 kcmil) Milan Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 584.4 sq. mm (1153.3 kcmil)

ACCC®-ULS Milan

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 13: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 592.5 mm2 1169.3 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-007) 9.53 mm 0.375 in.

Nominal Cross-sectional Area of Core 71.3 mm2 0.111 in

2

Overall Diameter of Conductor 29.89 mm 1.177 in.

Nominal Cross-sectional Area of the Conductor 663.8 mm2 1.029 in

2

Ultimate Tensile Strength of Conductor1,2 217.5 kN 48.9 kips

Rated Strength of Core - 375 ksi (2586 MPa) 184.2 kN 41.4 kips

Core Nominal Mass per unit length 128 kg/km 86 lb/kft

Conductor Nominal Mass per unit length 1769.9 kg/km 1189.5 lb/kft

Aluminum Nominal Mass per unit length** 1641.9 kg/km 1103.5 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.78E-05 /oC 9.91E-06 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 67.5 GPa 9.8 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0474 ohm/km 0.0763 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0494 ohm/km 0.0802 ohm/mile

AC Nominal Resistance at 75ºC 0.0588 ohm/km 0.0952 ohm/mile

AC Nominal Resistance at 180ºC 0.0785 ohm/km 0.1267 ohm/mile

1225 @ 100C & 50 Hz

1850 @ 180C & 50 Hz

GMR (estimated) 0.012 m 0.040 ft

Inductive Reactance 0.203 ohm/km 0.391 ohm/mile

Capacitive Reactance 0.173 Mohm-km 0.089 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-160-E ACCC-TW ULS 593 (1169 kcmil) Rome Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 609.9 sq. mm (1203.7 kcmil)

ACCC®-ULS Rome

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 14: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 629.2 mm2 1241.7 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-008) 8.76 mm 0.345 in.

Nominal Cross-sectional Area of Core 60.3 mm2 0.093 in

2

Overall Diameter of Conductor 30.42 mm 1.198 in.

Nominal Cross-sectional Area of the Conductor 689.5 mm2 1.069 in

2

Ultimate Tensile Strength of Conductor1,2 191.3 kN 43.0 kips

Rated Strength of Core - 375 ksi (2586 MPa) 155.9 kN 35.1 kips

Core Nominal Mass per unit length 109 kg/km 73 lb/kft

Conductor Nominal Mass per unit length 1848.2 kg/km 1242.2 lb/kft

Aluminum Nominal Mass per unit length** 1739.2 kg/km 1168.9 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.87E-05 /oC 1.04E-05 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 65.8 GPa 9.5 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0445 ohm/km 0.0716 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0466 ohm/km 0.0758 ohm/mile

AC Nominal Resistance at 75ºC 0.0554 ohm/km 0.0898 ohm/mile

AC Nominal Resistance at 180ºC 0.0738 ohm/km 0.1192 ohm/mile

1269 @ 100C & 50 Hz

1918 @ 180C & 50 Hz

GMR (estimated) 0.012 m 0.040 ft

Inductive Reactance 0.202 ohm/km 0.390 ohm/mile

Capacitive Reactance 0.172 Mohm-km 0.089 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-161-E ACCC-TW ULS 629 (1242 kcmil) Vienna Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 647.7 sq. mm (1278.2 kcmil)

ACCC®-ULS Vienna

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 15: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 668.3 mm2 1318.9 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-007) 9.53 mm 0.375 in.

Nominal Cross-sectional Area of Core 71.3 mm2 0.111 in

2

Overall Diameter of Conductor 31.50 mm 1.240 in.

Nominal Cross-sectional Area of the Conductor 739.6 mm2 1.146 in

2

Ultimate Tensile Strength of Conductor1,2 221.8 kN 49.9 kips

Rated Strength of Core - 375 ksi (2586 MPa) 184.2 kN 41.4 kips

Core Nominal Mass per unit length 128 kg/km 86 lb/kft

Conductor Nominal Mass per unit length 1979.5 kg/km 1330.4 lb/kft

Aluminum Nominal Mass per unit length** 1851.5 kg/km 1244.4 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.83E-05 /oC 1.02E-05 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 66.6 GPa 9.7 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0420 ohm/km 0.0676 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0440 ohm/km 0.0717 ohm/mile

AC Nominal Resistance at 75ºC 0.0523 ohm/km 0.0849 ohm/mile

AC Nominal Resistance at 180ºC 0.0697 ohm/km 0.1126 ohm/mile

1318 @ 100C & 50 Hz

1996 @ 180C & 50 Hz

GMR (estimated) 0.013 m 0.042 ft

Inductive Reactance 0.200 ohm/km 0.385 ohm/mile

Capacitive Reactance 0.170 Mohm-km 0.088 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-162-E ACCC-TW ULS 668 (1319 kcmil) Budapest Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 688 sq. mm (1357.7 kcmil)

ACCC®-ULS Budapest

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 16: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 685.4 mm2 1352.6 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-007) 9.53 mm 0.375 in.

Nominal Cross-sectional Area of Core 71.3 mm2 0.111 in

2

Overall Diameter of Conductor 31.77 mm 1.251 in.

Nominal Cross-sectional Area of the Conductor 756.7 mm2 1.173 in

2

Ultimate Tensile Strength of Conductor1,2 222.8 kN 50.1 kips

Rated Strength of Core - 375 ksi (2586 MPa) 184.2 kN 41.4 kips

Core Nominal Mass per unit length 128 kg/km 86 lb/kft

Conductor Nominal Mass per unit length 2030.6 kg/km 1364.7 lb/kft

Aluminum Nominal Mass per unit length** 1902.6 kg/km 1278.7 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.84E-05 /oC 1.02E-05 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 66.4 GPa 9.6 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0410 ohm/km 0.0660 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0431 ohm/km 0.0701 ohm/mile

AC Nominal Resistance at 75ºC 0.0511 ohm/km 0.0830 ohm/mile

AC Nominal Resistance at 180ºC 0.0681 ohm/km 0.1101 ohm/mile

1336 @ 100C & 50 Hz

2025 @ 180C & 50 Hz

GMR (estimated) 0.013 m 0.042 ft

Inductive Reactance 0.199 ohm/km 0.384 ohm/mile

Capacitive Reactance 0.169 Mohm-km 0.088 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-163-E ACCC-TW ULS 685 (1353 kcmil) Mumbai Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 705.6 sq. mm (1392.4 kcmil)

ACCC®-ULS Mumbai

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 17: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 690.7 mm2 1363.1 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-008) 8.76 mm 0.345 in.

Nominal Cross-sectional Area of Core 60.3 mm2 0.093 in

2

Overall Diameter of Conductor 31.77 mm 1.251 in.

Nominal Cross-sectional Area of the Conductor 751.0 mm2 1.164 in

2

Ultimate Tensile Strength of Conductor1,2 194.8 kN 43.8 kips

Rated Strength of Core - 375 ksi (2586 MPa) 155.9 kN 35.1 kips

Core Nominal Mass per unit length 109 kg/km 73 lb/kft

Conductor Nominal Mass per unit length 2026.2 kg/km 1361.8 lb/kft

Aluminum Nominal Mass per unit length** 1917.2 kg/km 1288.5 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.90E-05 /oC 1.06E-05 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 65.1 GPa 9.4 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0407 ohm/km 0.0655 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0428 ohm/km 0.0699 ohm/mile

AC Nominal Resistance at 75ºC 0.0508 ohm/km 0.0826 ohm/mile

AC Nominal Resistance at 180ºC 0.0676 ohm/km 0.1093 ohm/mile

1340 @ 100C & 50 Hz

2032 @ 180C & 50 Hz

GMR (estimated) 0.013 m 0.042 ft

Inductive Reactance 0.199 ohm/km 0.385 ohm/mile

Capacitive Reactance 0.169 Mohm-km 0.088 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-143-E ACCC-TW ULS 691 (1363 kcmil) Prague Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 711 sq. mm (1403.2 kcmil)

ACCC®-ULS Prague

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 18: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 733.2 mm2 1446.9 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-007) 9.53 mm 0.375 in.

Nominal Cross-sectional Area of Core 71.3 mm2 0.111 in

2

Overall Diameter of Conductor 32.85 mm 1.293 in.

Nominal Cross-sectional Area of the Conductor 804.5 mm2 1.247 in

2

Ultimate Tensile Strength of Conductor1,2 225.4 kN 50.7 kips

Rated Strength of Core - 375 ksi (2586 MPa) 184.2 kN 41.4 kips

Core Nominal Mass per unit length 128 kg/km 86 lb/kft

Conductor Nominal Mass per unit length 2165.9 kg/km 1455.6 lb/kft

Aluminum Nominal Mass per unit length** 2037.9 kg/km 1369.6 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.86E-05 /oC 1.04E-05 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 65.9 GPa 9.6 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0384 ohm/km 0.0618 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0405 ohm/km 0.0661 ohm/mile

AC Nominal Resistance at 75ºC 0.0480 ohm/km 0.0781 ohm/mile

AC Nominal Resistance at 180ºC 0.0638 ohm/km 0.1032 ohm/mile

1392 @ 100C & 50 Hz

2113 @ 180C & 50 Hz

GMR (estimated) 0.013 m 0.043 ft

Inductive Reactance 0.197 ohm/km 0.381 ohm/mile

Capacitive Reactance 0.167 Mohm-km 0.087 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-144-E ACCC-TW ULS 733 (1447 kcmil) Munich Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 754.8 sq. mm (1489.5 kcmil)

ACCC®-ULS Munich

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 19: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 749.5 mm2 1479.1 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-011) 10.54 mm 0.415 in.

Nominal Cross-sectional Area of Core 87.3 mm2 0.135 in

2

Overall Diameter of Conductor 33.40 mm 1.315 in.

Nominal Cross-sectional Area of the Conductor 836.8 mm2 1.297 in

2

Ultimate Tensile Strength of Conductor1,2 267.8 kN 60.2 kips

Rated Strength of Core - 375 ksi (2586 MPa) 225.6 kN 50.7 kips

Core Nominal Mass per unit length 157 kg/km 106 lb/kft

Conductor Nominal Mass per unit length 2235.6 kg/km 1502.5 lb/kft

Aluminum Nominal Mass per unit length** 2078.6 kg/km 1397.0 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.80E-05 /oC 9.98E-06 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 67.3 GPa 9.8 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0375 ohm/km 0.0604 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0395 ohm/km 0.0645 ohm/mile

AC Nominal Resistance at 75ºC 0.0469 ohm/km 0.0762 ohm/mile

AC Nominal Resistance at 180ºC 0.0624 ohm/km 0.1008 ohm/mile

1415 @ 100C & 50 Hz

2148 @ 180C & 50 Hz

GMR (estimated) 0.014 m 0.044 ft

Inductive Reactance 0.196 ohm/km 0.378 ohm/mile

Capacitive Reactance 0.166 Mohm-km 0.086 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-165-E ACCC-TW ULS 750 (1479 kcmil) Warwick Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 771.5 sq. mm (1522.6 kcmil)

ACCC®-ULS Warwick

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 20: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 759.0 mm2 1497.9 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-009) 9.78 mm 0.385 in.

Nominal Cross-sectional Area of Core 75.1 mm2 0.116 in

2

Overall Diameter of Conductor 33.40 mm 1.315 in.

Nominal Cross-sectional Area of the Conductor 834.1 mm2 1.293 in

2

Ultimate Tensile Strength of Conductor1,2 236.9 kN 53.3 kips

Rated Strength of Core - 375 ksi (2586 MPa) 194.2 kN 43.7 kips

Core Nominal Mass per unit length 135 kg/km 91 lb/kft

Conductor Nominal Mass per unit length 2239.9 kg/km 1505.4 lb/kft

Aluminum Nominal Mass per unit length** 2104.9 kg/km 1414.7 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.86E-05 /oC 1.03E-05 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.1 GPa 21.2 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 65.9 GPa 9.6 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0370 ohm/km 0.0595 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0391 ohm/km 0.0639 ohm/mile

AC Nominal Resistance at 75ºC 0.0464 ohm/km 0.0754 ohm/mile

AC Nominal Resistance at 180ºC 0.0616 ohm/km 0.0996 ohm/mile

1424 @ 100C & 50 Hz

2164 @ 180C & 50 Hz

GMR (estimated) 0.013 m 0.044 ft

Inductive Reactance 0.196 ohm/km 0.379 ohm/mile

Capacitive Reactance 0.166 Mohm-km 0.086 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-164-E ACCC-TW ULS 759 (1498 kcmil) London Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 781.3 sq. mm (1541.9 kcmil)

ACCC®-ULS London

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 21: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 813.7 mm2 1605.8 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-008) 8.76 mm 0.345 in.

Nominal Cross-sectional Area of Core 60.3 mm2 0.093 in

2

Overall Diameter of Conductor 34.16 mm 1.345 in.

Nominal Cross-sectional Area of the Conductor 874.0 mm2 1.355 in

2

Ultimate Tensile Strength of Conductor1,2 201.7 kN 45.3 kips

Rated Strength of Core - 375 ksi (2586 MPa) 155.9 kN 35.1 kips

Core Nominal Mass per unit length 109 kg/km 73 lb/kft

Conductor Nominal Mass per unit length 2361.8 kg/km 1587.3 lb/kft

Aluminum Nominal Mass per unit length** 2252.8 kg/km 1514.1 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.95E-05 /oC 1.08E-05 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 64.1 GPa 9.3 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0345 ohm/km 0.0555 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0368 ohm/km 0.0604 ohm/mile

AC Nominal Resistance at 75ºC 0.0435 ohm/km 0.0710 ohm/mile

AC Nominal Resistance at 180ºC 0.0576 ohm/km 0.0933 ohm/mile

1480 @ 100C & 50 Hz

2254 @ 180C & 50 Hz

GMR (estimated) 0.014 m 0.045 ft

Inductive Reactance 0.195 ohm/km 0.377 ohm/mile

Capacitive Reactance 0.165 Mohm-km 0.085 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-166-E ACCC-TW ULS 814 (1606 kcmil) Paris Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 837.6 sq. mm (1653 kcmil)

ACCC®-ULS Paris

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 22: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 880.9 mm2 1738.4 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-011) 10.54 mm 0.415 in.

Nominal Cross-sectional Area of Core 87.3 mm2 0.135 in

2

Overall Diameter of Conductor 35.76 mm 1.408 in.

Nominal Cross-sectional Area of the Conductor 968.2 mm2 1.501 in

2

Ultimate Tensile Strength of Conductor1,2 275.2 kN 61.9 kips

Rated Strength of Core - 375 ksi (2586 MPa) 225.6 kN 50.7 kips

Core Nominal Mass per unit length 157 kg/km 106 lb/kft

Conductor Nominal Mass per unit length 2595.0 kg/km 1744.0 lb/kft

Aluminum Nominal Mass per unit length** 2438.0 kg/km 1638.5 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.86E-05 /oC 1.03E-05 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 66.0 GPa 9.6 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0318 ohm/km 0.0512 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0340 ohm/km 0.0559 ohm/mile

AC Nominal Resistance at 75ºC 0.0402 ohm/km 0.0656 ohm/mile

AC Nominal Resistance at 180ºC 0.0532 ohm/km 0.0861 ohm/mile

1560 @ 100C & 50 Hz

2379 @ 180C & 50 Hz

GMR (estimated) 0.014 m 0.047 ft

Inductive Reactance 0.192 ohm/km 0.370 ohm/mile

Capacitive Reactance 0.162 Mohm-km 0.084 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-170-E ACCC-TW ULS 881 (1738 kcmil) Bordeaux Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 906.8 sq. mm (1789.6 kcmil)

ACCC®-ULS Bordeaux

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 23: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 944.9 mm2 1864.7 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-009) 9.78 mm 0.385 in.

Nominal Cross-sectional Area of Core 75.1 mm2 0.116 in

2

Overall Diameter of Conductor 36.85 mm 1.451 in.

Nominal Cross-sectional Area of the Conductor 1020.0 mm2 1.581 in

2

Ultimate Tensile Strength of Conductor1,2 247.4 kN 55.6 kips

Rated Strength of Core - 375 ksi (2586 MPa) 194.2 kN 43.7 kips

Core Nominal Mass per unit length 135 kg/km 91 lb/kft

Conductor Nominal Mass per unit length 2751.5 kg/km 1849.2 lb/kft

Aluminum Nominal Mass per unit length** 2616.5 kg/km 1758.5 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.93E-05 /oC 1.07E-05 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.0 GPa 21.2 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 64.5 GPa 9.4 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0297 ohm/km 0.0478 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0321 ohm/km 0.0529 ohm/mile

AC Nominal Resistance at 75ºC 0.0378 ohm/km 0.0619 ohm/mile

AC Nominal Resistance at 180ºC 0.0498 ohm/km 0.0808 ohm/mile

1623 @ 100C & 50 Hz

2483 @ 180C & 50 Hz

GMR (estimated) 0.015 m 0.048 ft

Inductive Reactance 0.190 ohm/km 0.367 ohm/mile

Capacitive Reactance 0.161 Mohm-km 0.083 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-142-E ACCC-TW ULS 945 (1865 kcmil) Antwerp Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 972.7 sq. mm (1919.6 kcmil)

ACCC®-ULS Antwerp

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 24: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 1006.5 mm2 1986.3 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-011) 10.54 mm 0.415 in.

Nominal Cross-sectional Area of Core 87.3 mm2 0.135 in

2

Overall Diameter of Conductor 38.20 mm 1.504 in.

Nominal Cross-sectional Area of the Conductor 1093.8 mm2 1.695 in

2

Ultimate Tensile Strength of Conductor1,2 282.2 kN 63.4 kips

Rated Strength of Core - 375 ksi (2586 MPa) 225.6 kN 50.7 kips

Core Nominal Mass per unit length 157 kg/km 106 lb/kft

Conductor Nominal Mass per unit length 2941.9 kg/km 1977.2 lb/kft

Aluminum Nominal Mass per unit length** 2784.9 kg/km 1871.7 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.90E-05 /oC 1.06E-05 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.7 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 65.1 GPa 9.4 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0278 ohm/km 0.0447 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0303 ohm/km 0.0499 ohm/mile

AC Nominal Resistance at 75ºC 0.0356 ohm/km 0.0583 ohm/mile

AC Nominal Resistance at 180ºC 0.0467 ohm/km 0.0759 ohm/mile

1692 @ 100C & 50 Hz

2594 @ 180C & 50 Hz

GMR (estimated) 0.015 m 0.050 ft

Inductive Reactance 0.188 ohm/km 0.363 ohm/mile

Capacitive Reactance 0.159 Mohm-km 0.082 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-167-E ACCC-TW ULS 1007 (1986 kcmil) Berlin Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 1036.1 sq. mm (2044.7 kcmil)

ACCC®-ULS Berlin

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 25: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 1013.1 mm2 1999.3 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-009) 9.78 mm 0.385 in.

Nominal Cross-sectional Area of Core 75.1 mm2 0.116 in

2

Overall Diameter of Conductor 38.20 mm 1.504 in.

Nominal Cross-sectional Area of the Conductor 1088.2 mm2 1.687 in

2

Ultimate Tensile Strength of Conductor1,2 251.2 kN 56.5 kips

Rated Strength of Core - 375 ksi (2586 MPa) 194.2 kN 43.7 kips

Core Nominal Mass per unit length 135 kg/km 91 lb/kft

Conductor Nominal Mass per unit length 2939.3 kg/km 1975.5 lb/kft

Aluminum Nominal Mass per unit length** 2804.3 kg/km 1884.7 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 1.95E-05 /oC 1.09E-05 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.1 GPa 21.2 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 64.1 GPa 9.3 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0276 ohm/km 0.0444 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0302 ohm/km 0.0498 ohm/mile

AC Nominal Resistance at 75ºC 0.0354 ohm/km 0.0581 ohm/mile

AC Nominal Resistance at 180ºC 0.0464 ohm/km 0.0755 ohm/mile

1696 @ 100C & 50 Hz

2602 @ 180C & 50 Hz

GMR (estimated) 0.015 m 0.050 ft

Inductive Reactance 0.188 ohm/km 0.363 ohm/mile

Capacitive Reactance 0.159 Mohm-km 0.082 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-168-E ACCC-TW ULS 1013 (1999 kcmil) Madrid Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 1042.9 sq. mm (2058.1 kcmil)

ACCC®-ULS Madrid

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial

Page 26: ACCC®-ULS Monte Carlo - CTC Global · 2019-01-22 · *ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 235.2 sq. mm (464.2

DATA SHEET:

Governing Units: Metric

Mechanical Specifications

Nominal Aluminum Cross-sectional Area* 1409.7 mm2 2782.0 kcmil

Nominal Diameter of Composite Core (CTC Part Number 210-011) 10.54 mm 0.415 in.

Nominal Cross-sectional Area of Core 87.3 mm2 0.135 in

2

Overall Diameter of Conductor 44.75 mm 1.762 in.

Nominal Cross-sectional Area of the Conductor 1497.0 mm2 2.320 in

2

Ultimate Tensile Strength of Conductor1,2 304.9 kN 68.5 kips

Rated Strength of Core - 375 ksi (2586 MPa) 225.6 kN 50.7 kips

Core Nominal Mass per unit length 157 kg/km 106 lb/kft

Conductor Nominal Mass per unit length 4058.4 kg/km 2727.6 lb/kft

Aluminum Nominal Mass per unit length** 3901.4 kg/km 2622.1 lb/kft

Maximum Allowable Operating Temperature at Surface4 180 o

C 356 oF

Coefficient of Linear Expansion Above Thermal Kneepoint 7.51E-07 /oC 4.17E-07 /

oF

Coefficient of Linear Expansion Below Thermal Kneepoint 2.00E-05 /oC 1.11E-05 /

oF

Final Modulus of Elasticity Above Thermal Kneepoint 146.8 GPa 21.3 Msi

Final Modulus of Elasticity Below Thermal Kneepoint 63.2 GPa 9.2 Msi

Electrical Specifications

Nominal Resistivity of Aluminum at 20ºC, DC 63% IACS 0.0199 ohm/km 0.0320 ohm/mile

Temperature Coefficient of Resistance 0.00403 0.00403

Frequency 50 Hz 60 Hz

AC Nominal Resistance at 25ºC 0.0231 ohm/km 0.0388 ohm/mile

AC Nominal Resistance at 75ºC 0.0267 ohm/km 0.0402 ohm/mile

AC Nominal Resistance at 180ºC 0.0343 ohm/km 0.0432 ohm/mile

2050 @ 100C & 50 Hz

3189 @ 180C & 50 Hz

GMR (estimated) 0.018 m 0.058 ft

Inductive Reactance 0.178 ohm/km 0.345 ohm/mile

Capacitive Reactance 0.150 Mohm-km 0.077 Mohm-mile

1) Based on 96% of the annealed aluminum minimum tensile strength given in ASTM B 609 and EN 50540.

2) Strength at ambient temperature

F-730-169-E ACCC-TW ULS 1410 (2782 kcmil) Athens Data Sheet www.ctcglobal.com Date Produced: 7/10/2015

Metric Imperial

AC Current Rating at Given Temperature3

The information contained herein is offered in good faith. The ACCC® manufacturer’s specification may have some variation from the indicated values in this spec

sheet, with the weight and cross sectional area being no more than ±2% of the value indicated.

**ACCC® Conductors are required to exhibit lay lengths (ratios) that conform to ASTM B 857 or EN 50540.

3) Conditions: 2 ft/s (0.61 m/s) wind, 0 ft (0 m) Elevation, 0.5 Emis. 0.5 absorp. 40°C Ambient temperature, 96 W/sq. ft (1033 W/sq. m) sun radiation

4) Maximum continuous operating temperature of ACCC® is 180°C and a maximum emergency temperature of 200°C (10,000 hours over the life of the conductor).

*ACCC® conductor is produced with 1350 O-tempered aluminum. The nominal H-19 Aluminum equivaelnt area is 1451.2 sq. mm (2863.8 kcmil)

ACCC®-ULS Athens

NOT RELEASED

For questions, please contact CTC Application Engineering Department: [email protected]

Metric Imperial