accessories - promoterm€¦ · for controlling a solar installation with calorifier fitted with 1...
TRANSCRIPT
www.dedietrich-heating.com278
Sol
ar in
stal
lati
ons
15
Package Ref.DMCDBEnergy transfer station from one storage tank to another and vice versa. Is fitted with 2 pumps (EEI � 0.23) and a 3-way valve; its design allows it to be connected directly to both tanks.The loading and unloading module allows the heat transfer between 2 tanks.
ER468 7604939
ER301 + ER 666 DB20 Drain-Back solar trasnfert moduleWall-hung, self draining, solar station for installing up to 20 m2 of flat collectors. It helps to prevent overheating and is particulary suitable for installations with random requirements (schools, crèches, etc...)Use with DIETRISOL PRO C 250 collectors
Extra storage with DB20 moduleTo handle installations of up to 25 m2 of collectors.
ER301
ER666
100017486
7619965
load/unload Station or energy tranSFer
8980
Q31
4AD
B20_
Q00
03
A
En
BCDEFG
Ae e
y a
r i g νεργεια
PICTO_ENERGIE_A-A
Package Ref.Solar station SKS 13-45➪ For installations with up to 40 m2 of collectors (manometric height of the solar pump 13 mCE) with solar calorifiers with built in exchanger or external plate exchangerThese solar stations are fitted with all components required to enable optimum operation of the solar installation: solar pump, non-return valves, safety valve, manometer, air/water separator with manual air vent, filling and draining system, thermometers… Option of including a SOL PLUS control unit.
ER665 7619964
8980F169
1
2
3
4
5
8980
F169
Accessoriesfor collective solar installations
Solar Station For SyStemS With BPB/BLC/B 600 to 3000, B 802 and 1002, PS 600 to 3000 caloriFierS
SK_Q
0001
➪ tranSFert unit SKS 13-45
➪ tranSFer unitS StS 14-30, 14-50, 14-100, d14-200 and 12-400 cmePackage Ref.
ER667
ER668
ER669
ER670
ER671
Transfer units STS 14-30 CME (1)Transfer units STS 14-50 CME (1)Transfer units STS 14-100 CME (1)Transfer units STS D 14-200 CME (1)Transfer units STS D 12-400 CME (1)
➪ For installations with up to 400 m2 of collectors, with exchanger suitable for DHW and heating waterUse: These stations are suitable for installations with DIETRISOL PRO C 250 or POWER collectors combined with tanks with no integrated exchanger.Construction : these stations are fitted with all the components needed to allow optimum operation of the solar installation with plate exchanger in "low flow" (15 l/m2.h) with the SOL SC. 5 control system:- delivered preset with STS 14-50 and 14-100 CME stations,- delivered with STS D 14-200 and D 12-400 CME for connection to the station via a bracket to fixed
to the wallAll the valves, pumps, etc. have been sized in relation to operating requirements according for the "low flow" principle of De Dietrich solar systems.Included for all stations are: the plate exchanger, the primary and secondary pumps, the 6-bar safety valve (primary and secondary circuit), the anti-thermosiphon valves, the pressure gauge, the filling and drainage valves, the thermometers. All these transfer stations are, as standard, equipped with a volumetric energy meter for an accurate count of contribution solar.The STS 14-200 and 12-400 CME are made respectively of 2 or 3 solar stations mounted in cascade or an aluminium frame.
ER667ER668ER669ER670ER671
76199667619967761996876199707619971
(1) Solar station STS : available only on order. If hard water, a water softener is imperative to product.
Solar Station/Solar tranSFer unitS For SyStemS With FWS or rSb caloriFier
SK_Q
0011
SK_Q
0009
SK_Q
0007
SK_Q
0005
SK_Q
0003
Sol
ar in
stal
lati
ons
15
279www.dedietrich-heating.com
Accessoriesfor collective solar installations
Solar control SyStemS and optionS
Package Ref.
SOL_
Q00
01
SOL PLUS control systemFor controlling a solar installation with calorifier fitted with 1 or 2 exchanger enabling heating zone reversal solar heating system with 3-way boiler return relief valve on the heating return circuits. Delivered with 3 sensors (TC, TS and TR).
ER709 7630422
8980
Q03
5
Regulation SOL SC. 5For controlling a solar installation with 1 or 2 collector fields and 1 or 2 solar calorifiers (one of which may have heating zone reversal) or 1 solar calorifier and 1 swimming pool with load and unload control and recover the return temperature. Delivered with 4 sensors (TC, TS, TP and TE).
ER672 761997289
80Q
317
DELTASOL E Control systemControl system designed to manage all solar installation with more than 2 primary and secondary circuits and a plate exchanger.
ER315 100017500
DB_
Q00
03
Regulation SOL AELFor controlling a solar installation with 1 calorifier fitted with 1 exchanger. Delivered with 2 sensors (TC and TS). The unit is able to control the heating/electrical back-up
ER708 7630421
8980
Q03
5
Differential control system MCDBDifferential control system used to load 1 DHW calorifier from a buffer volume (solar or wood-field boiler), or transfer energy from one storage tank to another and vice versa.
8980F243
MCDB
MCDB
DMCDB
8980
F243
EC162 100004650
8980
Q24
0
3-way valve 3/4" with reversal motorFor solar circuit with 2 tanks and Sol control system.
EC164 89804803
8980
Q26
0
Kit with 2 valves + sensorFor controlling an installation with 2 EAST/WEST collector fields with SOL SC. 5.
EC432 100011341
SOL_
Q00
03
Conencting kit (PWM) for a 2 solar pumpsAllows the connection of a second solar pump on the SOL PLUS control system.(installation with 2 tanks or 2 x East/west colelctor fields.
ER712 7630423
SOL_
Q00
02
ModBUS connecting cable (3m)For connection between a SOL PLUS control system and a DIEMATIC iSystem control panel.
ER713 7630424
8980
Q26
3
Energy metering kitComprises a flow rate meter (1.5 m3/h max. flow rate) and 2 sensors. Used to meter energy accurately in solar installations. It must be mounted in the solar circuit.
EC174 100004652
8980
Q28
9
AM1 breakdown report moduleWarns of operating errors by flash signal and any breakdown report on a building management system for DIEMASOL or SOL. control system.
ER314 100017499
8980
Q28
1
Irradiation sensor CS 10With STS station only. Replace the collector sensor who has to stay on the solar installation.
EC175 89804815
8980
Q27
9
Lightning conductor boxFor SOL control system. Protects the control system against power surges if the collectors field is struck by lightning.
EC176 89804816
Sol
ar in
stal
lati
ons
15
www.dedietrich-heating.com280
Accessoriesfor collective solar installations
other acceSSorieS
DESCRIPTION PACKAGE REF.SLA 2 differential control system EC320 100007832Expansion vessel:- 18 litres EG117 100019427- 24 litres EG118 100019428- 50 litres EG83 89807772- 60 litres EG84 89807773- 100 litres EG120 100008733- 200 litres EG122 100008735- 300 litres EG123 100008736Wall bracket for expansion vessel up to 25 litre EC118 89807238Thermostatic mixing valve for a DHW flow up to 39 l/h (DHW flow at ∆P = 1.5 bar) EG78 89807767
Collector sensor PT 1000 EC155 100008011Dip sensor PT 1000 EC173 100004651Contact sensor PT 1000 EC171 100003690
DESCRIPTION PACKAGE REF.Heat transfer fluid:- High performance pre-mix type LS,
20 litres (-28°C) EG100 89807792
- Pre-mix "BIO" (-30°C) low viscosity high resistance on the corrosion and freez without BORAX type LR-25 (20 litres)
ER316 100017611
DESCRIPTION PACKAGE REF.Filling station with pump and car EG81 89807770Hand pump for tapping up with fluid EG80 89807769Check box for solar installation ER50 100012031Antifreeze protection tester (for checking the heat transfert fluid) EG102 89807797
Measuring box with refractometer EG104 89807799Cleaning material for solar circuit solRnet ER318 100020025
8980
Q04
3
EG117
8980
Q03
8
EG109EG110
8980
Q07
2
EG376
8980
Q03
7
DUO-Tube
DB2
00_Q
0008
ER319
8980
Q07
1
EG374EG375
8980
Q25
1
DUO-flex
DESCRIPTION PACKAGE REF.Double, pre-insulated “DUO-TUBE” or “DUO-FLEX” pipes with UV protection and cable for sensor (bicone connectors are to be ordered separately) :- Duo-Tube Cu 10 x 10 m ER319 100020297- Duo-Tube Cu 15 x 10 m EG106 89807000- Duo-Tube Cu 15 x 15 m EG107 89807001- Duo-Tube Cu 18 x 15 m EG108 89807002- Duo-Flex in ribbed stainless steel Ø 16 x 15 m
(with easyclic connection) EG422 7648217
- Duo-Flex in ribbed stainless steel Ø 20 x 15 m EG423 7648218- Duo-Flex in ribbed stainless steel Ø 20 x 20 m EG424 7648219- Duo-Flex in ribbed stainless steel Ø 25 x 25 m EG426 7648220Set of collars “Duo-Tube” and "Duo-Flex":- for Duo-Tube Cu 15 and Duo-Flex Ø 16mm,
4 parts EG109 89807003
- for Duo-Tube Cu 18 and Duo-Flex Ø 20mm, 4 parts EG110 89807004
Set of bicone connectors for “Duo-tube” or “Duo-Flex” (without soldering):- Set of 2 bicone connectors Ø 15mm
(for Duo-tube) EG374 100000417
- Set of 2 bicone connectors Ø 18mm (for Duo-tube) EG375 100000418
- Set of 2 bicone connectors Ø 15/18mm (for Duo-tube and Duo-Flex) EG376 100000419
2 easy clic connections for Duo-Flex Ø 25 mm - 1" 1/4 F EG427 7648221
➪ duo-tube
Sol
ar in
stal
lati
ons
15
281www.dedietrich-heating.com
Accessoriesfor collective solar installations
Package Ref.Hot fluid meters- 3.5 m3/h- 2.5 m3/h- 1.5 m3/hUltrasound energy meters, compatible with a 130°C heat-transporting fluid, ACS approvedACS cold water meters- 20 m3/h- 10 m3/h- 5 m3/h- 3.5 m3/hACS approved class C ultrasound flow rate meters for cold water with consumption totaliser
ER312ER311ER310
ER317ER309ER308ER307
100017497100017496100017495
100019195100017494100017493100017492
Energy metering WMZ kitAllows the meter energy in a hydraulic system. It is used in addition to the volumetric flow meter - package EC174.
ER131 100014590
CME energy measurement unitCan be used to track, totalise and take stock of the energy individually contributed to a hot water production system (for a GRS, for example) by a multi-energy system (solar + gas, fuel oil or electric back-up).The CME can track 4 fluid circuits, 2 electric circuits (Finder 7E) and 1 gas meter (ITRON Gallus or RF1). It can be connected to our DELTASOLs & DIEMASOLs by VBus and the DL 2 communication interface for remote control of the installation.
ER313 100017498
DL2 communication interfaceThe DL 2 handles communication between the solar control system and a computer. It can be used: to display all the operating statuses and modes of a solar installation, check efficiency, detect simple default and transmit data directly to a PC or a router for remote inquiries. Software for downloading data is delivered with the interface.
ER55 100013514
DL3 communication interfaceThe DL 3 has the same functions as the DL 2 interface, but is designed to centralise the data from 3 installations (or 3 solar control systems combined with 3 CME measurement units and/or WMZ measurement units). Software for downloading data is delivered with the interface.
ER139 100019224
Dip sensorPT1000
EC173 100004651
Contact sensorPT1000
EC171 100003690
Connection cable BUSLength 40 m.
DB119 81997720
energie metering
8980
Q28
789
80Q
272
8980
Q30
189
80Q
254
8980
Q25
58
19
9Q
06
389
80Q
035
8980
Q28
6