accessories for heliax products--product selection guide 2007

64
Accessories FOR HELIAX ® PRODUCTS PRODUCT SELECTION GUIDE 2007

Upload: others

Post on 19-Feb-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Accessories for HELIAX Products--Product Selection Guide 2007

Accessories FOR HELIAX® PRODUCTS

PRODUCT SE L ECT ION GU IDE 2007

Page 2: Accessories for HELIAX Products--Product Selection Guide 2007
Page 3: Accessories for HELIAX Products--Product Selection Guide 2007

Table of Contents

�Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

A

B

D

A

D

E

F

C

A­ Cable­Hoisting­and­Attachment

B­ Weatherproofing

C­ Cable­Entry

D­ Grounding­Kits

E­ Grounding­Bars

F­ Arrestor­Plus®­Surge­Arrestors

Introduction

Cable Installation Accessories

Cable Hoisting and Attachments ................................................. 8

Weatherproofing ....................................................................... 19

Cable Entry ............................................................................... 22

Installation Aids......................................................................... 24

Lightning Protection

Grounding Kits .......................................................................... 30

Grounding Bars ......................................................................... 34

Surge Arrestors ........................................................................ 37

Appendixes

Appendix 1: Quarterwave Stub Surge Arrestors ....................... 40

Appendix 2: Gas Tube Surge Arrestors .................................... 43

Appendix 3: dc Passing T-Series Surge Arrestors .................... 46

Appendix 4: Lightning Strike Probability .................................. 47

Appendix 5: Additional Documents .......................................... 48

Appendix 6: Hanger Spacing Guidelines .................................. 49

Index ............................................................................................... 58

Page 4: Accessories for HELIAX Products--Product Selection Guide 2007

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�

Andrew’s Clear Advantage­

Around the globe, in a world being transformed by communications, people anticipate more than ever that wireless services will enhance their lives, workplaces, and communities.

With­the­convergence­of­voice,­data,­and­video,­we­experience­the­promise­of­mobility—and­we­experience­Andrew.­Andrew­supports­the­emerging­mobile­society,­and­the­companies­that­make­this­today’s­reality,­with­complete­wireless­solutions.­Our­customers­represent­the­leading­wireless,­broadband,­and­satellite­communication­providers­of­the­world.­We­support­all­major­operators­and­OEMs­in­every­region­and­are­extremely­proud­of­these­relationships,­many­of­which­we­have­served­for­decades.

Andrew­solutions­are­technology­agnostic­and­unbiased­regarding­platform,­frequency­and­technology­evolution,­even­within­our­own­product­portfolio.

With­our­broad­base­of­products,­we­support­more­global­markets­and­offer­more­knowledge­and­experience­in­licensing,­spectrum­analysis­and­utilization,­asset­optimization,­and­customized,­multi-prong­problem-solving­for­building,­optimizing,­and­enhancing­networks­for­growth­and­success.

Simply,­we­understand­your­challenges­and­are­uniquely­prepared­to­help­as­an­unmatched­one-stop­resource­for­managing­the­entire­life­cycle­of­wireless­networks.

Andrew­provides­products­and­solutions­for­the­entire­RF­footprint­with­our­Antenna­and­Cable­passive­products­and­our­Wireless­Network­Solutions­active­products.­Our­substantial­investment­in­global­research­and­development­ensures­a­pipeline­of­new­products­and­solutions­that­address­our­customers’­evolving­network­requirements.

The­Andrew­flash­represents­an­enviable­70-year­legacy­of­customer­service­that­brings­us­to­today,­with­over­11,000­employees­in­35­countries,­and­an­unmatched­global­distribution­network­that­ensures­that­our­customers­receive­essential­support­wherever­and­whenever­they­need­it.­Our­talents,­expertise,­and­commitment­are­always­nearby,­and­our­local­presence­in­every­region­of­the­world­ensures­cost-effective­products­and­on-time­delivery­and­services.

Everywhere­you­look,­the­promise­of­mobility­is­here—and­we­at­Andrew­promise­to­listen,­anticipate,­and­innovate,­and­to­continue­to­earn­the­trust­and­respect­of­our­customers.

Page 5: Accessories for HELIAX Products--Product Selection Guide 2007

�Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

n Base­Station­Antenna­and­Remote­Electrical­Downtilt­Systems

n­ Microwave­Antennas

n­ Coaxial­Foam,­Air,­and­Specialty­Cable

n­ Connectors,­Surge­Arrestors,­and­Assemblies

n­ Broadband­Cables

n­ Site­Installation­Products­and­Services

n­ Bias­Tees

ANTENNA AND CABLE PRODUCTS

n Single-Carrier­Power­Amplifiers

n­ Multicarrier­Power­Amplifiers

n­ Custom­In-Cabinet­Amplifiers

n­ Custom­In-Cabinet­Filters

n­ Tower­Mounted­Amplifiers

n­ Filters/Combiners

n­ Integrated­Products

n­ Micro/Pico­Cells

n­ Remote­Radio­Heads

n­ After­Market­Services

BASE STATION SUBSYSTEMS

n Geolocation­and­Location­Based­Services/Geolocation­Mobile­Location­Solutions

n­ Spectrum­Management

n­ Network­Optimization

n­ Network­Infrastructure­and­Program­Management­

n­ Advanced­Data­Collection

NETWORK SOLUTIONS

n RF­Repeaters

n­ RF­Boosters

n­ Optical­Distribution­Networks

n­ Radiating­Cable

n­ Passive­Splitters,­Combiners,­Duplexers,­Terminators,­and­Indoor­Antennas

n­ Operations­and­Maintenance­Center

n­ Turnkey­System­Design­and­Project­Management

WIRELESS INNOVATIONS

n Direct-to-Home­Outdoor­Units

n­ Very­Small­Aperture­Terminal­Outdoor­Units

n­ Earth­Station­Antennas

n­ Gateway­Systems

n­ MilSatCom­Antenna­Systems

n­ Government/Radar­Antennas

n­ RF­Electronics

n­ Site­Installation­and­Services

SATELLITE COMMUNICATIONS

Antenna and Cable Products Segment Wireless Network Solutions Segment

Page 6: Accessories for HELIAX Products--Product Selection Guide 2007

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�

Planning SoftwareAASP—the first and only PCS/Cellular Systems Design Software

Design­your­PCS­or­cellular­system­in­less­time,­with­greater­accuracy­and­

lower­costs­with­advanced­Andrew­Antenna­Systems­Planner­software­(AASP).­Powerful­AASP­software­graphically­guides­you­through­the­entire­design­process,­from­the­choice­of­frequency­to­the­avail-

able­shipping­options.­The­program’s­dynamic,­rule-based­logic­generates­

custom­solutions­by­using­standard­Andrew­products­while­automatically­checking­component­compatibility.­Upon­completion,­AASP­provides­you­with­a­customized­bill­of­­materials­of­the­Andrew­parts­necessary­for­the­system.­AASP­is­available­on­the­Andrew­Powertools™­CD­or­as­a­download­from­­www.andrew.com.

OnePackSM Site KitsThe Answer for More Efficient System Build-outs

Today’s­global­build-out­demands­new­solutions­that­speed­system­deployment­and­simplify­supply­chain­management.­To­help­system­managers­better­achieve­these­goals,­Andrew­offers­kits­for­wire-less­RF­communications­systems­sites.­OnePack­Site­Kits­provide­the­critical­components­in­easy­to­order,­easy­to­manage­packages.­System­designers­and­managers­can­be­confident­of­shortened­project­planning­and­execution­cycles,­improved­efficiency,­and­dependable­system­performance.

Customer Support Center (CSC)Service Around the Clock, Around the World

Contact the Andrew Customer Support Center for:

d­­Technical­support

d­­Order­status

d­­Coordinating­product­service,­repairs,­or­replacement

d­­Product­information

d­­Replacement­materials

Call toll free from:

North­America­ 1-800-255-1479­Fax­ 1-800-349-5444­

International:­United­Kingdom­ 0800-250055­Australia­ 1800-803­219­New­Zealand­ 0800-441-747­Call­from­other­areas:­ +1­708-873-2307

Services

Page 7: Accessories for HELIAX Products--Product Selection Guide 2007

Installation Techniques to Ensure Quality!Andrew­products­and­people­are­at­the­forefront­of­connecting­the­wireless­world.­As­the­industry­evolves,­the­Andrew­Institute®­is­committed­to­providing­you­with­quality,­effective­training.­Our­trainers­deliver­knowledge­that­can­develop­your­skills­and­self-assurance,­as­well­as­benefit­your­system­performance­and­reliability.­Dedicated­Andrew­Institute­trainers­will­share­their­proven­installation­techniques­and­expertise­with­you­in­one-­or­­two-day­sessions.

“Build an Agenda” Customize Your Training:

Connector Attachment­

(1­hour­per­connector)

d­­Cable­concepts

d­­Connector­attachment

d­­Accessories

RET Antenna­

(2­hours)

d­­Antenna­concepts

d­­Mounting­techniques

d­­Weatherproofing

d­­Inspection­and­maintenance

�Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.comAndrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com �

More­customers­are­mandating­that­technicians­installing­their­systems­are­registered­as­having­completed­Andrew­Institute­training.

Orland­Park,­Illinois­USA

Lochgelly,­Scotland

Sorocaba,­Brazil

Suzhou,­China

Andrew Institute Technical TrainingYou will learn:

d­­­How­to­obtain­the­highest­possible­performance­with­every­Andrew­product­installed

d­­System­fundamentals­and­how­components­work­together

d­­Proper­installation­of­cable,­connectors,­and­accessories­through­­hands-on­practice

d­­TMW­systems­fundamentals­and­essential­elements­of­path­alignment

d­­Pressurization­systems­theory­of­operation­and­installation­techniques

d­­Proper­path­alignment

d­­Fundamentals­of­VSWR­sweep­testing,­insertion­loss,­and­TDR/FDR­plots

The­Andrew­Institute­welcomes­the­opportunity­to­serve­the­industry.­We­can­bring­select­courses­to­your­facility,­or­you­can­come­to­any­one­of­our­convenient­training­locations.

Terrestrial Microwave Systems­

(2­days)

d­­RF­theory/TMW­fundamentals

d­­Antenna­installation

d­­Path­alignment

d­­Pressurization­fundamentals

For more information visit our Web site at: www.andrew.com

Registration is available online or call: +1-779-435-6231

Fundamentals of VSWR­

(4­hours)

d­­Typical­site­configuration

d­­Plot/sweep­interpretation

d­­Troubleshooting

Page 8: Accessories for HELIAX Products--Product Selection Guide 2007

Selection Guide

Elements of a Cable Mounting and Protection System

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�

Once you’ve selected the cable and connectors for your system, the cable mounting and protection system must be planned. Andrew offers a comprehensive line of installation accessories and lightning protection systems to help you realize your communications system’s full potential.

Hoisting Grips

Select­a­hoisting­grip­to­safely­raise­the­cable­and­hold­it­during­hanger­attachment.­In­some­cases,­a­hoisting­grip­must­also­be­used­with­a­calibrated­clamp,­available­from­Andrew,­to­provide­permanent­support­for­­the­cable.

Hangers

The­type­or­shape­of­the­structure,­the­space­available­for­cable­attachment,­the­type­of­environment­the­system­will­be­exposed­to,­and­the­ease­of­installation­or­maintenance­are­key­considerations.­Many­hanger­options­are­available,­and­many­variables­have­tradeoffs­that­affect­total­hanger­system­cost.­The­table­on­page­18­will­help­you­select­the­best­hangers­for­your­system­and­budget.

Weatherproofing

Weatherproofing­keeps­connector­interfaces­tight­and­adds­an­additional­layer­of­protection­against­the­environment.­Andrew­offers­three­types­of­weatherproofing.­A­standard­weather-proofing­kit­provides­universal­coverage­and­uses­butyl­and­vinyl­tapes­to­wrap­connector­surfaces.­Our­3M™­Cold­Shrink™­weatherproofing­kit­uses­a­self-shrinking­technology­to­reduce­installation­time.­New­WeatherShield™­enclosures­seal­and­protect­connectors­for­the­environment­in­seconds.

Cable Entry

The­final­step­in­a­base­station­installation­is­to­bring­the­cable­into­the­building­or­radio­cabinet.­Two­basic­types­of­cable­entry­systems­are­available:­a­standard­building­entry,­and­an­integrated­system­that­combines­cable­entry­and­lightning­surge­suppression­into­one­efficient­system.­

Grounding Kits

A­grounding­kit­diverts­transient­currents­from­lightning­off­the­transmission­line­to­an­earth­grounding­system­to­prevent­damage­to­cable­and­radio­equipment.­A­typical­installation­uses­three­grounding­kits:­near­the­top­of­the­main­feeder­cable,­at­the­bottom­of­the­main­feeder­prior­to­the­horizontal­run,­and­just­prior­to­the­cable­entering­the­building.­Andrew­offers­three­kit­types­to­meet­the­requirements­of­your­system­and­budget.

Surge Arrestors

Andrew­Arrestor­Plus®­surge­arrestors­provide­the­last­stage­of­an­effective­lightning­protection­system.­Install­them­to­divert­lightning­transients­off­the­inner­conductor­of­your­coaxial­cable­before­they­reach­your­radio­equipment.­Select­from­a­variety­of­surge­arrestors­to­meet­your­exact­requirements.

­

Page 9: Accessories for HELIAX Products--Product Selection Guide 2007

( Cable Hoisting and Attachment

( Weatherproofing

( Cable Entry

( Installation Aids

CA

BLE INSTA

LLATION

AC

CESSO

RIES

Page 10: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Cable Hoisting and Attachment

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�

Support/Hoisting GripSafer, Faster Cable Hoisting

Lift­and­support­cable­in­your­monopole­or­on­your­tower­faster­and­more­safely­and­without­the­threat­of­slippage.­Our­one-piece­grip­and­locking­clamp­speed­and­simplify­installation­by­eliminating­time­consuming­lacing.

Use­at­200­ft­(60­m)­intervals­to­raise­cable­and­provide­permanent­cable­support.­Basic­kit­includes­one­grip­and­one­support­clamp.­Support­clamps­are­also­available­in­kits­of­10.­Installation­tool­is­required.­

Part Number Part Number

Support Grip Support Clamp Cable Size Cable Type

F1SGRIP F1SGRIP-1IK 1/4" FSJ1L1SGRIP L1SGRIP-1IK 1/4" LDF1E2SGRIP E2SGRIP-2IK 3/8" EFX2L2SGRIP L2SGRIP-2IK 3/8" LDF2F2SGRIP F2SGRIP-2IK 3/8" FSJ2C2SGRIP C2SGRIP-2IK 3/8" CNT-400L4SGRIP L4SGRIP-4IK 1/2" LDF4F4SGRIP F4SGRIP-4IK 1/2" FSJ4L45SGRIP L45SGRIP-45IK 5/8" LDF4.5L5SGRIP L5SGRIP-5IK 7/8" LDF5, VXL5L6SGRIP L6SGRIP-6IK 1-1/4" LDF6, VXL6L7SGRIP L7SGRIP-7IK 1-5/8" LDF7, VXL7L12SGRIP L12SGRIP-12IK 2-1/4" LDF123CCGRIP — — RET cablePart Number DescriptionSG-IT Support Clamp Installation Tool

Standard Hoisting Grip For Transmission Line Installation

Use­at­200­ft­(60­m)­intervals­to­raise­cable­on­tower.­Use­with­addi-tional­support­clamp­to­achieve­optimum­cable­grip.

Part Number Part Number

Hoisting Grip Support Clamp Cable Size

43094 L4SGRIP-4IK 1/2"29958 L45SGRIP-45IK 5/8"19256B L5SGRIP-5IK 7/8"29961 L6SGRIP-6IK 1-1/4"24312A L7SGRIP-7IK 1-5/8"31535 L12SGRIP-12IK 2-1/4"26985A — 3"34759 — 4"31031-1 — 5"

Use the support/hoisting grip whenever possible. Rely on the standard, lace up hoisting grip only when connectors are pre-attached or you have to place a grip in the middle of a cable run over 200 ft.

TIP!

TIP!

Page 11: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Cable Hoisting and Attachment

�Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

Snap-In Hangers Attachment with No Hardware!

Andrew­Snap-In­hangers­provide­quick­and­easy­attachment­in­all­types­of­weather.­The­hangers­snap­directly­into­holes­in­the­tower­support­members.­Installation­time­and­costs­are­substantially­reduced.­These­hangers­feature­cable­gripping­tabs­to­prevent­cable­slippage,­and­are­constructed­of­heavy­gauge­stainless­steel­for­high­strength­and­excel-lent­corrosion­resistance.­Waveguide­versions­include­a­heavy­UV­resis-tant­rubber­insert­to­secure­the­elliptical­waveguide.

Part Number Description206706A-6 For 5/8" cable206706A-5 For 2-1/4" cableEWSH-52 For EW52 waveguideEWSH-63 For EW63 waveguideEWSH-64 For EW64 waveguideEWSH-77 For EW77 waveguideEWSH-90 For EW90 waveguideEWSH-127A For EW127A waveguideEWSH-132 For EW132 waveguideEWSH-180 For EW180 waveguideEWSH-220 For EW220 waveguideEWSH-240 For EW249 waveguide

SnapStak™ HangersNo more worries about fumbling with hardware or losing small parts—because there aren’t any!

New­antenna­systems­can­now­be­added­to­crowded­multiple-tenant­towers—with­minimal­space!­SnapStak­snap-in­hangers­can­be­stacked­up­to­three­deep­when­using­1/2­in­and­7/8­in­coaxial­cable,­or­two­deep­when­using­1-1/4­in­and­1-5/8­in­coaxial­cable.­Each­hanger­accommodates­one­run­of­HELIAX®­cable.

The­distinctive,­self-contained­design­of­the­SnapStak­stackable­snap-in­hanger­eliminates­the­need­for­mounting­hardware­and­installation­tools.­This­simplifies­coaxial­cable­installations,­lowering­both­time­and­cost.

Retention­tabs­on­the­spring­fork­make­SnapStak­hangers­highly­resis-tant­to­pop-out,­so­installations­are­robust­and­secure.­Yet,­specially­designed­to­dampen­vibrations,­SnapStak­hangers­do­not­have­a­rigid­hold­on­the­tower,­so­motion­caused­by­wind­is­simply­absorbed.­This­reduces­movement­down­the­coaxial­cable,­greatly­reducing­stress­on­the­connections­at­the­jumper­cable,­antenna,­or­device.

SnapStak­hangers­can­be­mounted­directly­to­the­tower­support­system,­or­used­in­conjunction­with­a­variety­of­mounting­accessories­for­rooftops,­buildings,­and­water­towers.­The­SnapStak­hanger­installs­in­3/4­in­holes­in­support­structures­1/8­in­(0.120­in­to­0.150­in)­thick.­The­stainless­steel­construction­of­the­SnapStak­snap-in­hanger­provides­exceptional­integrity,­even­in­highly­corrosive­environments­and­extreme­weather­conditions.­Compact­installations­save­tower­space.­And­maintenance­is­easy,­since­SnapStak­stackable­snap-in­hangers­are­self­sufficient—no­hardware­required­for­installation!­Mounts­to­pre-punched­3/4­in­(19­mm)­holes,­kit­of­10.

Part Number DescriptionSSH-12 SnapStak hanger kit for 1/2" corrugated cableSSH-78 SnapStak hanger kit for 7/8" corrugated cableSSH-114 SnapStak hanger kit for 1-1/4" corrugated cableSSH-158 SnapStak hanger kit for 1-5/8" corrugated cableSSHAK-3812 SnapStak hanger kit for RET cableSSHA-38 Insert, adapts 1/2" snap in hanger to RET cableUnited­States­Patents:­6,345,543,­6,899,305,­and­6,161,804.­Other­patents­pending.­

Page 12: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Cable Hoisting and Attachment

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�0

Snap-In Tower StandoffsFor­mounting­snap-in­hangers­to­round­support­members.­Adapter­is­designed­with­3/4­in­pre-punched­hole.­Adapter­provides­2-1/2­in­(60­mm)­standoff.­All­parts­are­stainless­steel­or­galvanized,­kit­of­10.­

Part Number Member Diameter, in (mm)STS3-12 1–2 (25–50)STS3-23 2–3 (50–75)STS3-34 3–4 (75–100)STS3-45 4–5 (100–125)

SnapStak™ Hanger ToolSpecially­designed­pliers­make­installation­and­removal­of­SnapStak­snap-in­hangers­extremely­easy.­The­spring­loaded­pliers­are­designed­with­a­hook­that­holds­and­spreads­the­hanger­open­to­slip­easily­over­the­cable.­Serrated­pads­then­squeeze­the­hanger­together­for­effortless­insertion­into­the­mounting­structure.­Insulated­handle­and­a­lanyard­hole­make­it­easy­to­hang­on­to.

Part Number Description SHT-4 SnapStak hanger tool, quantity 1

Part Number DescriptionUA-3 Universal snap-in adapter, kit of 10

Universal Angle Adapter InsertInsert­transitions­the­universal­adapter’s­3/4­in­to­a­3/8­in­hole­diameter,­which­allows­the­use­of­standard­hangers.

Part Number DescriptionUAAI Universal angle adapter Insert, kit of 10

Each­part­sold­separately

(­UA-3

(­UAAI

Universal Snap-In AdapterThe­universal­snap-in­adapter­is­a­versatile­device­for­securing­coaxial­cable­hangers­to­structures­such­as­communications­towers,­rooftops,­buildings­and­water­towers.

The­universal­snap-in­adapter­secures­coaxial­cable­to­any­round­or­angle­tower­members­where­pre-punched­holes­are­not­easily­acces-sible.­The­adapter­has­a­pre-punched­3/4­in­hole­that­allows­the­installer­to­mount­cable­hangers­such­as­Andrew­SnapStak™­snap-in­hangers­to­wireless­communications­towers­or­other­structures.­Stainless­steel­construction­for­long­life.­

Universal Adapter Applications

Page 13: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Cable Hoisting and Attachment

��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

Cluster Support BracketThe­cluster­support­bracket­is­a­versatile­means­to­support­multiple­runs­of­coaxial­cable­in­virtually­any­application.­The­oval­design­allows­coaxial­cable­to­be­run­inside­and­outside­of­the­bracket,­which­maxi-mizes­its­capacity.­Each­bracket­features­3/4­in­holes­to­accommodate­snap-in­hangers­and­3/8­in­holes­for­butterfly­hangers­using­standard­3/8­in­hardware.­The­cluster­support­bracket­supports­seven­runs­of­coaxial­cable.­Sold­in­units­of­one,­U-bolt­hardware­sold­separately.

Part Number Description CS-B Cluster support bracket with U-bolt for 2-3/8" round member attachment

PVC Roof SleeperSupport­rooftop­coaxial­cable­runs­using­the­snap-in­PVC­roof­sleepers.­PVC­roof­sleepers­are­pre-punched­with­3/4­in­holes­to­accommodate­snap-in­hangers.­Sleepers­are­made­of­a­gray­4­in­(102­mm)­x­4­in­(102­mm),­UV-resistant­PVC­material.­

Part Number DescriptionMT-F1598 4 run, 22" (559 mm) lengthMT-F1599 8 run, 32" (810 mm) lengthMT-F1600 12 run, 43" (1102 mm) length

Snap-In Adapter BracketThis­bracket­is­used­in­conjunction­with­WRAPLOCK®­and­is­used­on­large,­round­members,­water­towers,­or­outside­of­a­monopole.­The­brackets­slide­on­the­WRAPLOCK­and­hold­up­to­six­runs­of­coaxial­cable.­You­can­use­multiple­brackets­for­the­number­of­runs­required­for­your­system.­The­galvanized­steel­bracket­supports­both­standard­hangers­and­snap-in­hangers.­Accommodates­six­runs­of­snap-in­hangers­and­four­runs­of­click-on­hangers.

Part Number DescriptionRM-USBG Snap-in adapter bracket, kit of 1012395-1 Stainless steel WRAPLOCK

Universal Snap-In BracketThese­galvanized­steel­brackets­are­designed­to­work­on­both­angle­and­round­members.­They­are­pre-punched­with­3/4­in­holes­to­hold­snap-in­hangers­or­standard­hangers.

Part Number DescriptionSS-TB2550 Universal snap-in bracket, for 1-1/2" to 5-9/16" round member 2-1/2" to 5" angle member. Accommodates six snap-in or standard hangers.SS-TB6080 Universal snap-in bracket, for 6" to 10-3/4" round member 6" to 8" angle member accommodates six snap-in or standard hangers.

Anchor Rail AdapterAnchor rail adapters make cable installation fast, secure, and neat.

These­one-piece,­one-size,­self-contained­anchor­rail­adapters­require­no­tools­and­snap­into­common­strut­or­anchor­rail­systems,­such­as­UniStrut®­Metal­Framing.­The­3/4­in­hole­accepts­common­snap-in­hangers.­Adapters­can­be­used­for­horizontal­or­vertical­cable­to­produce­neatly­aligned­installations­on­large­poles,­smokestacks,­rooftops,­walls,­or­any­support­structure.United­States­Patent:­7,090,174.­UniStrut­is­a­registered­trademark­of­the­­UniStrut­Corporation

Part Number DescriptionARA-22 Anchor rail adapter for 0.86" (22 mm) rails (North American standard), kit of 10

Page 14: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Cable Hoisting and Attachment

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

Angle­Adapter­Attachment

Ceiling­Adapter­Attachment

Part Number Attachment Hardware243684 Compact angle adapter, see page 16 for details244350 Ceiling adapter, kit of 10Round­member­adapter­(various­sizes)­see­page­16

Round­Member­Attachment

Flat­Member­Attachment

Click-On HangersClick-On Hangers—Install Cable with One Easy “Click”

Specifically­designed­to­support­HELIAX®­coaxial­cable,­stackable­click-on­hangers­install­in­just­minutes­and­provide­a­perfect­fit­that­gives­your­PCS/PCN,­cellular,­microwave,­rural­telephony,­GSM,­or­other­telecommunications­system­a­professional­appearance,­especially­in­confined­spaces.­

Available­in­either­single­or­double­versions,­click-on­hangers­are­manufactured­of­tough­UV-resistant­material­and­set­the­standard­for­durability,­simplicity­of­installation,­and­cost­effectiveness.­United­States­Patent:­5794897.

Double Single*

Part Number Part Number DescriptionL4CLICK L4SCLICK 1/2" hanger, kit of 10L45CLICK — 5/8" hanger, kit of 10L5CLICKB L5SCLICKB 7/8" hanger, kit of 10L6CLICK L6SCLICK 1-1/4" hanger, kit of 10L7CLICK L7SCLICK 1-5/8" hanger, kit of 10

Snap-In Adapter BlockThis­snap-in­adapter­block­is­designed­to­accommodate­a­snap-in­hanger­on­each­side­of­the­block.­You­can­attach­this­to­the­tower­with­our­standard­angle­adapters­or­tower­standoffs.­Stainless­steel­construction.

Part Number DescriptionSA-38 Snap-in adapter block, kit of 10

Page 15: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Cable Hoisting and Attachment

��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

Click-On Hanger Hardware KitsClick-on­hanger­attachment­hardware­is­available­in­3/8­in­or­M10­sizes.­Constructed­of­stainless­steel­for­durability.­Select­hardware­length­according­to­planned­hanger­stack­height.­Each­kit­contains­10­threaded­rods,­30­nuts,­40­flat­washers­and­20­lock­washers.­Note:­Click-on­hangers­accommodate­two­runs­of­cable­and­can­be­stacked­up­to­three­deep­to­handle­up­to­six­runs.

Part Number Stack Height Cable Size Rod Length (# of hangers) in (mm)

Imperial

243095-9 1 1/2" or 7/8" 3.75 (95)243095-5 2 1/2" or 7/8" 5.40 (137)243095-1 3 1/2" or 7/8" 7.00 (177)243095-10 1 1-1/4" or 1-5/8" 4.75 (121)243095-6 2 1-1/4" or 1-5/8" 7.25 (184)243095-2 3 1-1/4" or 1-5/8" 9.75 (248)

Metric

243095-11 1 1/2" or 7/8" 3.97 (101)243095-7 2 1/2" or 7/8" 5.50 (141)243095-3 3 1/2" or 7/8" 7.10 (181)243095-12 1 1-1/4" or 1-5/8" 5.00 (126)243095-8 2 1-1/4" or 1-5/8" 7.30 (186)243095-4 3 1-1/4" or 1-5/8" 9.90 (251)

Miniature Click-On HangersFast, easy installation for small cables

Now­installing­small­cables­into­hangers­is­accomplished­in­one­easy­click­with­miniature­click-on­hangers.­

Each­compact,­miniature­click-on­hangers­accommodates­two­runs­of­cable.­Miniature­click-on­hangers­are­compact­and­stackable,­making­it­easy­to­install­several­runs­of­cable­in­confined­spaces.

Miniature­click-on­hangers­are­cost­effective­and­durable.­With­flexible­gripping­ribs,­the­hanger­provides­secure­support­on­a­range­of­cable­sizes,­and­indexing­on­the­hanger­body­helps­align­cables­during­­installation.­

Specifically­designed­to­accommodate­small­corrugated­coaxial­cables,­elliptical­waveguide,­and­braided­cable­runs,­miniature­click-on­hangers­provide­a­perfect­fit­for­your­installation.­Hangers­are­packed­in­kits­of­10.­Attachment­hardware­made­of­anti-corrosion­coated­metal­for­long­service­life­is­sold­separately­in­kits­of­10.­

United­States­Patent:­7,007,900.

Select hardware by intended hanger stack height.

Part Number Description68MCLICK Click-on hangers for 6-8 mm cable; FSJ1A, CNT-240, CNT-300912MCLICK Click-on hangers for 9-12 mm cable; LDF1, EFX2, FSJ2, LDF2, CNT-400, EW3801316MCLICK Click-on hangers for 13-16 mm cable; FSJ4, LDF4-50A, CNT-500, CNT-600

Part Number Description252026-10KT Mini angle adapters, M8 tap252027-10KT Single stack hardware for mini click-on hangers, M8 thread252028-10KT Double stack hardware for mini click-on hangers, M8 thread 252029-10KT Triple stack hardware for mini click-on hangers, M8 thread

Multi-run hangers are the best choice for installing cables where space is very limited on crowded towers.

TIP!

TIP!

Page 16: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Cable Hoisting and Attachment

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

KwikClamp™ HangersMultiple Run Cable Hangers for European Norms

Ideal­for­multiple­run­cable­hangers­designed­exclusively­for­European-style­towers,­cost­effective­KwikClamp­cable­hangers­eliminate­the­need­for­drilling­and­adapters.­These­self-clamping­cable­hangers­attach­directly­to­round­or­flat­tower­members,­providing­sturdy,­reliable,­­long-term­support­to­systems.­Hangers­are­sold­in­kits­of­10.­

KwikClamp Ordering Information

See­the­table­below­to­build­a­KwikClamp­part­number­for­your­application.­

­ 1 Select your cable size and note the base part number shown below that cable size.

2 Select the tower member type and the number of cable runs for your application.

3 Locate the part number detail at the junction of the cable size column and the tower member type row. The base part number plus the part number detail indicates the full part number.

For­example,­the­KwikClamp­hanger­part­number­for­three­runs­of­­7/8­inch­cable­on­an­8–25­mm­round­tower­member­is­L5CLAMP-RDN-3.

Cable and Hanger Type

Cable Size RG8 1/2" 5/8" 7/8" 1-1/4" 1-5/8"

Base Part Number R8CLAMP-( ) L4CLAMP-( ) L45CLAMP-( ) L5CLAMP-( ) L6CLAMP-( ) L7CLAMP-(

Tower Member Type # of Runs Part Number Detail

3-11 mm 2 UNV-2 — — — — —

8-25 mm round or3-25 mm flat plate 1 — RDN-1 RDN-1 RDN-1 RDN-1 RDN-1 2 — RDN-2 RDN-2 RDN-2 RDN-2 RDN-2 3 — RDN-3 RDN-3 RDN-3 RDN-3 RDN-3

Page 17: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Cable Hoisting and Attachment

��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

Standard HangersStandard Hangers and Hardware—For Security and Flexibility

Standard­hangers­are­designed­for­easy­installation.­The­clamp­locking­bolt­and­nut­are­pre-assembled­and­captivated­to­minimize­installa-tion­labor.­Proper­tension­is­easy­to­determine.­The­hanger­is­simply­tightened­until­there­is­a­5/16­in­gap­between­the­clamp­legs.­The­pre-­drilled­hole­for­3/8­in­or­1/2­in­mounting­hardware­and­slots­for­round­member­adapter­clamps­further­simplify­installation.­See­pages­16–18­for­accessories­to­adapt­these­hangers­to­most­tower­configurations.

Please­refer­to­Appendix­6­for­specific­recommendations.

Hanger Part Number Cable Size Photo Reference43211A 3/8" A43211A 1/2" A42396A-9 5/8" B42396A-5 7/8" B42396A-1 1-1/4" B42396A-2 1-5/8" B42396A-4 2-1/4" B31766A-11 3" C31766A-10 4" C

Hanger Waveguide Part Number Size Photo Reference31766A-9 EW17 C31766A-10 EW20 C31766A-11 EW28 C42396A-4 EW37 B42396A-16 EW43 B42396A-8 EW52 B42396A-7 EW63 B42396A-1 EW64 B42396A-11 EW77 B42396A-5 EW85 B42396A-5 EW90 B42396A-9 EW127A B42396A-9 EW132 B43211A EW180 B43211A EW220 B43211A EW240 B

Hardware Sets, Kit of 10Imperial­kits­include­3/8­in­fillister-head­bolts,­lock­washers,­and­nuts­for­attachment­of­standard­hangers­to­drilled­tower­members.­The­metric­kit­includes­M10­bolts­and­lock­washers­for­use­with­metric­angle­adapters.

Part Number Length31769-5 3/4" (19 mm) 31769-1 1" (25 mm) 243684-MH Metric M10 19 mm

Additional Mounting HardwareThreaded Rod Support Kit for Standard Hangers.

Use­to­mount­hangers­away­from­supporting­structure,­under­cable­bridge,­and­inside­equipment­room.­Includes­3/8­in­diameter­threaded­rod,­galvanized­ceiling­mounting­plate,­nuts,­and­washers.­Attach­to­angle­tower­members­with­31768A­angle­adapters.­Attach­to­round­tower­members­with­30848­series­tower­standoffs.­All­components­are­stainless­steel,­except­ceiling­mounting­plate.

Part Number Part Number Rod Length, in (mm)

Kit of 1 Kit of 5

31771 31771-4 12 (305) 31771-9 31771-6 24 (610) — 31771-10 36 (915)

A B C

Page 18: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Cable Hoisting and Attachment

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

Angle AdapterStainless­steel,­kit­of­10.­For­mounting­1/2­in­to­4­in­cable­hangers­to­angle­tower­members­up­to­7/8­in­(22­mm)­thick.­Includes­hanger­attachment­hardware.

Part Number Description31768A 3/8" hardware31768A-M Metric hardware

Round Member AdapterStainless­steel­clamps­to­mount­1/2­in­to­4­in­cable­hangers­to­round­support­members.­Two­each­are­needed­for­3­in­and­4­in­cable­hangers,­kit­of­10.

Part Number Member Diameter, in (mm)31670-1 1–2 (25–50)31670-2 2–3 (50–75)31670-3 3–4 (75–100)31670-4 4–5 (100–125)31670-5 5–6 (125–150)31670-6 6–8 (150–200)

Angle Adapter Galvanized and Non-marring

For­mounting­1/2­in­to­2-1/4­in­cable­hangers­to­angle­tower­members­up­to­3/4­in­(19­mm)­thick.­Hanger­attachment­hardware­sold­sepa-rately,­kit­of­10.

Part Number Description247763-I Tapped for 3/8" hardware247763 Tapped for metric hardware

Compact Stainless Steel Angle AdaptersThese­compact,­lightweight,­high­quality­stainless­steel­angle­adapters­provide­a­cost­saving­option­to­standard­adapters­for­many­wireless­systems­that­use­HELIAX®­coaxial­cable.­These­compact­angle­adapters­are­suitable­for­use­with­single­runs­of­HELIAX­cable­up­to­2-1/4­in­in­diameter.­When­used­with­our­stackable­click-on­hangers,­they­can­accommodate­up­to­six­runs­of­1-1/4­in­cable­or­smaller­cable­and­up­to­four­runs­of­1-5/8­in­cable.­Includes­3/8­in­or­mid-hanger­attach-ment­hardware,­­kit­of­10.

Part Number Description

243684­ Imperial­angle­adapter,­kit­of­10

243684-M­ Metric­angle­adapter,­kit­of­10

Page 19: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Cable Hoisting and Attachment

�7Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

45° AdapterUse­with­angle­adapter­and­threaded­rod­support­kit­to­place­a­hanger­at­a­waveguide­bend,­kit­of­10.

Part Number Description

42334 45 degree adapter, kit of 10­

Clamp Head

Part Number DescriptionMF39901-10 Clamp head, kit of 10

Nylon Cable Ties For Jumper Cable AttachmentCable­ties­secure­cable­bundles­where­space­is­limited.­They­are­an­excellent­choice­for­organizing­jumper­cables­within­and­between­radio­cabinets­and­for­bundling­jumper­cables.­Nylon­cable­ties­provide­support­for­small­diameter­cable­1/4­in­to­1/2­in.­Typical­applica-tions­include­securing­jumper­cables­in­buildings­and­along­horizontal­antenna­mounting­arms.

Part Number Description40417 Nylon cable ties, 5/16" wide

14.5" long, kit of 50

Tower Standoff Adapters­with­round­member­clamps­and­hardware­for­1/2­in­to­4­in­hangers.­All­parts­are­stainless­steel­or­galvanized,­kit­of­10.

Part Number Member Diameter, in (mm)30848-5 0.75–1.5 (20–40)30848-4 1.5–3.0 (40–75)30848-1 3–4 (75–100)30848-2 4–5 (100–125)30848-3 5–6 (125–150)

Page 20: Accessories for HELIAX Products--Product Selection Guide 2007

Hanger TypeConstruction

Cable runs supported

Primary applications

Typical installation time (minutes)***

Key feature

Benefits

Attachment capability (Tower member type)

Additional parts needed

Tower adapters (allows hanger attachment to various tower types)

SnapStak™ HangersStainless steel

1 to 3

Towers with pre-punched cable ladders, snap-in accessories

7

Attaches cables in compact bundles, saving tower space

•­­Fastest hanger installation; No additional hardware needed

•­­Attaches cables in compact three run bundles

•­­Impervious to environmental extremes

•­­Universal hanger accommodates all corrugated cables

•­­3/4" drilled cable ladder

•­­Various adapters (see pages 10–11)

None

•­­Cluster mount•­­Universal tower

adapter•­­Anchor rail adapter

Standard HangersStainless steel

1

Tower installations subject to high wind, high corrosion, and high ice

20

Stainless steel tensioning hardware

•­­Impervious to environmental extremes

•­­Adaptable to various tower configurations

•­­3/8" (M10) drilled cable ladder

•­­Various adapters (see pages 16-17)

Tower attachment hardware kit

•­­Round member adapter

•­­Angle adapter

Support/ Hoisting Grips*Tin coated bronze

1

Monopole towers

2

Calibrated clamp provides permanent cable support

•­­Quick installation•­­Monopole

application•­­Accommodates

single run of cable

• All towers and monopoles

None

• None required

Cable Ties**Nylon

1

Jumper cables and inter-rack cabling

Universal fastening

•­­Fits most cable sizes and tower members

•­­Quick installation•­­Inexpensive•­­Accommodates

single run of light-weight cable

• Round member, angle member, cable ladders

None

• None required

Conditions­ *­ Support­grip­or­hoisting/support­grip­required­with­all­cable­installations­ **­ Should­only­be­used­with­1/2­in­cable­and­smaller­ ***­ Installation­time­based­on­a­100­ft­(30­m)­run­of­7/8­in­cable­with­3­ft­(1­m)­hanger­spacing.­Monopole­application­applied­200­ft­intervals,­2­minutes.

Click-On Single, Double, or Miniature HangersEngineered plastic single or double

2 to 6

Rooftops, water towers, and towers with limited space

20

Stackable up tothree high

•­­Attaches cables in compact six run bundles

•­­Versatile and adaptable to almost any application

•­­Easy to install click-on design

•­­UV stable

•­­3/8" (M10) drilled hardware ladder

•­­Various adapters (see pages 12–13)

Threaded rod and hardware

•­­Round member adapter

•­­Angle adapter

KwikClamp™ HangersStainless steeland plastic

1 to 3

New or existingtowers

15

Built in toweradapter

•­­Requires no additional hardware for tower attachments

•­­Fits round, flat angle, and C-channel tower members

•­­Quick installation•­­UV stable

•­­Round member Angle member channel section

•­Cable ladders

None

None required

Cable Installation Accessories

Hanger Selection Guide

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

Page 21: Accessories for HELIAX Products--Product Selection Guide 2007

NEW! WeatherShield™ Reusable Connection Protection Enclosures For In-Line Connectors, Antennas, and Tower Top Devices

Complete­your­transmission­line­installation­with­WeatherShield­connec-tion­protection­enclosures­which­seal­and­protect­connectors­from­the­environment.

This­robust,­one-piece­weatherproofing­enclosure­offers­an­additional­measure­of­system­protection­by­providing­a­high­temperature­resistant,­watertight­seal­around­the­connectors­while­also­helping­to­dampen­vibration­that­can­loosen­connector­interfaces­over­time.

The­reusable­enclosure­contains­an­innovative­trifold­seal­that­provides­complete­moisture­block­for­installed­connectors.­The­ease­of­instal-lation­on­hard-to-reach­connections­and­the­long-term­protection­provided­by­this­enclosure­makes­it­the­most­cost-effective­solution­available­today.­The­WeatherShield­connection­protection­enclosure­takes­just­seconds­to­install.­Simply­place­the­housing­around­the­connector­and­snap­the­tabs­together.

No­tapes,­tools,­or­shrink­tubes­are­required.­The­Andrew­WeatherShield­connection­protection­enclosures­will­accommodate­Type­N­and­­7-16­DIN­connections­and­are­compatible­with­Andrew­HELIAX®­cable,­SureFlex™­cable­assemblies,­and­most­brands­of­standard­jumpers.

Part Number DescriptionAWE-A12 Enclosure for 1/2" antenna connection/deviceAWE-7812 Enclosure for 7/8" to 1/2" connectionsAWE-11412 Enclosure for 1-1/4" to 1/2" connectionsAWE-15812 Enclosure for 1-5/8" to 1/2" connections

Cable Installation Accessories

Weatherproofing

��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

More Information: See the installation video at www.andrew.com/ products/trans_line/heliax/weathershield.aspx

Page 22: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Weatherproofing

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�0

Part Number Minimum Application Diameter, in (mm)* Kit Coverage, Cable Size to Cable Size

Connectors, 7-16 DIN or Type N

245173 0.63–0.41 (16–10.0) 3/8" through 1/2" to 3/8" through 1/2"241475-13 0.80–0.29 (20–7.4) 1/4" through 5/8" to 1/4" through 1/2"245171 0.84–0.29 (2–7.4) 7/8" to 1/4" through 1/2"245172 1.20–0.29 (30–7.4) 1-5/8" or 1 1/4" to 1/4" through 1/2"245175 1.40–0.41 (36–10.0) 2-1/4" to 1/4" through 1/2"

Antennas, filters, amplifiers, 7-16 DIN or Type N**

245174 0.84–0.29 –(21–7.4) 1/2"–7/8" jumpers to antenna

*­Minimum­application­diameter­is­the­fully­compressed­diameter­of­each­tube­in­the­kit.­**Andrew­3M™­Cold­Shrink™­Weatherproofing­is­completely­compatible­with­Andrew­base­station­antennas.­See­special­publication­SP50030­for­specific­application­information­on­the­use­of­Cold­Shrink™­for­antenna­interfaces.

Weathertight Seal Quickly Installs in Three Minutes

Complete­your­transmission­line­installation­with­the­premier­weatherproofing­product­to­seal­and­protect­connectors,­splices,­surge­protectors,­and­jumper-to-antenna­interfaces­from­the­environment.­Andrew­3M™­Cold­Shrink™­weatherproofing­protects­your­investment­and­your­system’s­performance.­

No Tools Required

Cold­Shrink­weatherproofing­simply­slips­over­the­connection­and­compresses­around­the­interface.­No­tapes­or­heat­guns­are­required­for­sealing­or­shrinking.­Simply­place­the­Cold­Shrink­kit­over­the­cable­and­connector,­make­the­connection,­and­unwind­the­pull-tab­applicator.­Once­it­is­collapsed,­its­continuous­compression­design­forms­a­watertight­seal­around­the­cable.­Developed­jointly­by­Andrew­and­3M™­Corporation,­Cold­Shrink­weatherproofing­has­proven­itself­in­thousands­of­high­power­cable­installations­for­more­than­15­years.

Fits up to 2-1/4 in HELIAX® Cable

Kits­are­available­for­transitions­from­larger­to­smaller­diameter­cable,­such­as­1-5/8­in­to­1/2­in,­or­for­same­diameter­cable,­such­as­1/2­in­to­1/2­in.­See­the­table­for­part­numbers.

3M­and­Cold­Shrink­are­trademarks­of­Minnesota­Mining­and­Manufacturing­Company

Self-fusing TapeSelf-fusing­and­marking­tape­is­a­time­saving­alternative­to­traditional­butyl­rubber­sealant­tapes.­The­silicone­tapes­are­produced­from­specially­formulated­UV-resistant­silicone­rubber.­When­applied­to­RF­connectors,­the­tape­wraps­bond­together­giving­the­connection­­an­additional­layer­of­protection­against­water,­dirt,­and­vibration.­Compared­to­conventional­tapes,­self-fusing­tape­is­both­easy­to­­apply­and­remove­from­connections.

Available­in­three­colors­options,­self-fusing­tape­can­also­be­used­to­color­code­tower­top­cable­installations,­making­it­easy­to­locate­cables­for­monitoring­purposes.

Part Number Description QuantityFT-TB Self-fusing tape, black .030" x 1.5" x 15' 2 rollsFT-TR Self-fusing tape, red .030" x 1.5" x 15' 2 rolls FT-TW Self-fusing tape, white .030" x 1.5" x 15' 2 rolls

Page 23: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Weatherproofing

��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

Standard Weatherproofing Kit for Connectors and AntennasThe­application­of­sealing­materials­to­antenna­cable­connections­protects­them­from­weather­conditions.­These­include­moisture­penetra-tion­and­loosening­of­connections­from­vibrations­caused­by­strong­winds.­Andrew­Corporation­recommends­weatherproofing­these­connec-tions­with­standard­weatherproofing­tapes­such­as­butyl­and­plastic­electrical­tapes.

d­Main­feeder­cable-to-jumper­cable­connection­d­­Jumper­cable-to-antenna­connection

This­kit­provides­an­additional­moisture­seal­for­cable­connections.­­It­also­prevents­loosening­of­connections­from­vibration­or­other­external­stresses,­which­would­eventually­allow­moisture­penetration.­The­sealed­connection­is­suitable­for­typical­exposed­and­buried­cable­applications.

Weatherproofing Connections Per Kit

Applications Connection Type Per Kit2-1/4" to 1/2" (57 mm to 13 mm) 21-5/8" to 1/2" (41 mm to 13 mm) 21-1/4" to 1/2" (32 mm to 13 mm) 27/8" to 1/2" (22 mm to 13 mm) 41/2" to 1/2" (13 mm to 13 mm) 127/8" to antenna, amplifier, device (22 mm to 13 mm) 121/2" to antenna, amplifier, device (13 mm to 13 mm) 12

Installation Tips

d­­When­applied,­the­tape­must­be­above­32°F­(0°C)­to­ensure­adhe-sion.­Keep­tape­warm­by­carrying­in­coat­pockets.

d­­­Do­not­stretch­the­tape.­Apply­only­enough­tension­to­provide­a­smooth­wrap.

d­­­Smooth­each­wrapped­layer­with­your­hands­to­ensure­­full­adhesion.

d­­­Do­not­pull­the­tape­to­tear­tape—always­cut­it.­(Pulled­tape­eventu-ally­unravels,­decreasing­protection.)­

d­­Add­extra­final­layers­of­tape­in­warmer­climates­where­there­will­be­long­exposure­to­damaging­ultra­violet­(UV)­rays.­Two­or­three­extra­layers­of­tape­will­provide­additional­UV­protection.

d­­When­wrapping­tape,­overlap­the­tape­to­half-width.

d­­Ensure­vent­or­drain­holes­at­the­bottom­of­the­antenna­or­device­are­not­covered­with­weatherproofing­tape.

Andrew 221213 Weatherproofing Kit contains: 2­rolls­of­3/4­in­x­66­ft­black­plastic­tape­1­roll­of­2­in­x­20­ft­black­plastic­tape­6­rolls­of­2-1/2­in­x­24­in­butyl­rubber­tape

Colored Electrical Marking Tape Colored­tape­is­a­convenient­way­to­mark­and­code­cable­runs.­­Six­different­colors­are­available­in­3/4­in­x­66­in­rolls.­Sold­in­­individual­rolls.

Part Number Description CM-TB Blue, 3/4" x 66' (19.1 mm x 20.1 m)CM-TBR Brown, 3/4" x 66' (19.1 mm x 20.1 m)CM-TG Green, 3/4" x 66' (19.1 mm x 20.1 m)CM-TR Red, 3/4" x 66' (19.1 mm x 20.1 m)CM-TW White, 3/4" x 66' (19.1 mm x 20.1 m)CM-TY Yellow, 3/4" x 66' (19.1 mm x 20.1 m)

Standard Weatherproofing TapePart Number Description 221213 Complete kit, black221213-S Complete kit, slate gray42615-10 2-1/2" x 24" butyl rubber roll9905-41 3/4" x 66' black plastic tape roll9905-71 2" x 20' black plastic tape roll

Page 24: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Cable Entry

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

Multiple Entrance Wall/Roof Feed-Thru PlatePlate­with­one­or­more­4­or­5-inch­holes.­Weatherproof­sealing­caps­included.­Use­with­the­corresponding­size­rubber­cable­boot­(sold­sepa-rately).

Part Number Number Height, Width of Openings in (mm) in (mm)

4 in (102 mm) Entry Opening, Multiple Entrance Plate

204673-1 1 7.0 (178.0) 7 (178)204673-2 1 5.0 (127.0) 5(127)204673-2A 3 9.5 (241.3) 20 (508)204673-4 4 9.5 (241.3) 25.5 (648)204673-6 6 17.5 (444.0) 23 (584)204673-8 8 17.5 (444.0) 25.5 (648)204673-9 9 23.0 (584.0) 23.0 (584)204673-10 10 9.5 (241.3) 31.0 (787)204673-12 12 25.5 (648.0) 25.5 (648)204673-16 16 25.5 (648.0) 25.5 (648204673-18 18 25.5 (648.0) 39.5 (1003)204673-20 20 28.8 (731.0) 31.0 (787)204673-24 24 31.0 (787.0) 39.5 (1003)

Hole PlugsPart Number DescriptionPLUG-12 Plug, 1/2", for unused cable boot holes, kit of 5PLUG-78 Plug, 7/8", for unused cable boot holes, kit of 5PLUG-114 Plug, 1-1/4", for unused cable boot holes, kit of 5PLUG-158 Plug, 1-5/8", for unused cable boot holes, kit of 5

Standard Cable Entry BootsUse­with­feed-thru­plate­with­the­corresponding­size­entry­hole.

Cable Boot Cable Number of Part Number Size Holes in Boots

4 in (102 mm) Cable Boots

204679A-17 1/4" foam 3204679A-19 3/8" foam 1204679A-5 1/2" foam 1204679A-7 1/2" foam 3204679A-6 1/2" air 1204679A-1 1/2" air 3204679A-16 1/2" 4204679A-13 5/8" 1204679A-14 5/8" 3204679A-2 7/8" 1204679A-18 7/8" 2204679A-15 7/8" 3204679A-3 1-1/4" 1204679A-4 1-5/8" 1204679A-8 2-1/4" 1204679A-9 3" 1CAP-4 Blank cap 0

5 in (127 mm) Cable Boots

48939A-16 3/8" foam 348939A-6 1/2" foam 148939A-8 1/2" foam 348939A-7 1/2" air 148939A-5 1/2" air 348939A-17 1/2" 448939A-14 5/8" 148939A-15 5/8" 348939A-1 7/8" 148939A-2 7/8" 348939A-3 1-1/4" 148939A-4 1-5/8" 148939A-9 2-1/4" 148939A-10 3" 1EP-CAP5 Blank cap 0

Single Entrance Wall/Roof Feed-Thru AssemblyIncludes­rubber­boot,­clamp,­and­aluminum­plate.­­Order­from­table.

Part Number Cable SizeSCE-12 1/2"SCE-58 5/8"SCE-78 7/8"SCE-114 1-1/4"SCE-158 1-5/8"SCE-214 2-1/4"

ArrestorPort™ II Integrated Transmission Line Entry/Ground SystemThe­ArrestorPort­II­integrated­building­entry/ground­system­­redefines­the­way­you­achieve­cable­shelter­entry­and­grounding.­Traditional­installations­rely­on­a­piecemeal­approach­that­steals­time­and­increases­costs.­ArrestorPort­II­unifies­the­installation­of­entry­ports,­Arrestor­Plus®­surge­protectors,­and­transmission­line­grounding­into­an­integrated­entry/ground­system.­Arrestor­Plus­surge­arrestors­cut­costs,­save­valuable­interior­space,­and­protect­your­revenues­and­personnel­from­the­damaging­effects­­of­lightning­strikes.

The­ArrestorPort™­II­integrated­wall­entry/grounding­system­kit­consists­of­an­entry­panel­and­a­1/8­in­solid­copper­ground­bar­assembly­with­assembly­hardware,­weather­stripping,­and­weatherproof­sealing­caps­for­all­entry­ports.­Use­with­Arrestor­Plus­surge­arrestors­(pages­37­and­38,­order­separately)­and­standard­cable­boots­(page­22­and­23,­order­separately).

Part Number Description APORT-13-4 Provides mounting positions for 13 bulkhead mount surge arrestors and includes four 4" holes for waveguide entry

Page 25: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Cable Entry

��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

Elliptical Waveguide—Standard Cable Entry Wall and Roof Feed-Thru and BootsA­ ­Single­entrance­wall/roof­feed-thru­assembly.­Includes­rubber­boot,­

clamp,­and­galvanized­steel­plate.­Order­from­table­below.

B­ ­Single­entrance­wall/roof­feed-thru­assembly­for­EW37–EW240.­Includes­rubber­boot,­clamps,­and­aluminum­plate.­

C­ ­Waveguide­boot­for­use­with­204673­and­48940­series­multiple­entrance­wall/roof­feed-thru­plates.­Boot­diameter­of­4­in­or­5­in­(102­or­127­mm)­is­available­to­match­plate.­Order­individually­from­table­below.

A, B Single Entrance Wall/Roof Feed-Thru Assemblies

Single Entrance For Waveguide Photo Size Reference Part NumberEW17 A 35849A-10EW20 A 35849A-9EW28 A 35849A-13EW37 B 245314-37EW43 B 245314-43EW52 B 245314-52EW63 B 245314-63EW64 B 245314-64EW77 B 245314-77EW85 B 245314-85EW90 B 245314-90EW127A B 245314-127AEW132 B 245314-132EW180 B 245314-180EW220 B 245314-220EW240 B 245314-240

C

B

CA

BA C

C Waveguide Boots

Part Number by DiameterFor Waveguide Size 4 in (102 mm) 5 in (127 mm)EW17 — —EW20 — — EW28 — —EW37 WGB4-37 WGB5-37EW43 WGB4-43 WGB5-43EW52 WGB4-52 WGB5-52EW63 WGB4-63 WGB5-63EW64 WGB4-64 WGB5-64EW77 WGB4-77 WGB5-77EW85 WGB4-85 WGB5-85EW90 WGB4-90 WGB5-90EW127A WGB4-127 WGB5-122EW132 WGB4-132 WGB5-132EW180 WGB4-180 WGB5-180EW220 WGB4-220 WGB5-220EW240 WGB4-240 WGB5-240

Page 26: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Installation Aids

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

EASIAX® 2 Cable Preparation ToolsImprove­system­performance­and­cut­installation­time­with­special-ized­EASIAX­2­cable­preparation­tools.­Wireless­installation­specialists­require­tools­that­provide­precision­and­consistency­when­attaching­connectors.­The­tools­provide­a­clean­cut­of­the­coaxial­cable­and­eliminate­copper­shavings.­This­lessens­the­potential­for­high­VSWR­and­IMD­readings.­EASIAX­2­tools­also­reduce­the­time­spent­preparing­cable­for­connector­attachment­by­40%,­compared­to­using­common­tools.­

Part Number Description CPTV2-158 Cable preparation tool for use with AL, AVA, VXL, and

LDF 1-5/8" cableCPTV2-114 Cable preparation tool for use with VXL and

LDF 1-1/4" cableCPTV2-BK Replacement blade kit for CPTV2 tools

EASIAX Replacement Blades

Tool Replacement Blade Kit

Part Number Part Number CPT-L1 CPT-BKS1CPT-F4 CPT-BKCPT-L4ARC1 CPT-BKS1CPT-E2L2DIN CPT-BKS1CPT-E2L2N CPT-BKS1CPT-L45RC CPT-BKS1CPTL6 CPT-BK6CPT-158U CPT-BK7CPT-78U CPT-BK5Recommended­drill­size­for­tools­for­1/4­in­through­1/2­in­cables­is­3/8­in­torque­value­with­12­volt­minimum.­Cordless­drill­14.4­minimum­voltage,400–650­RPM.

Recommended­drill­size­for­tools­for­7/8­in­through­1-5/8­in­cable­is­1/2­in.­Cordless­drill­15.4­minimum­voltage,­400–650­RPM.

For­detailed­information­on­cable­preparation,­see­Special­Publication­SP50262.

Better Connections Yield Superior System PerformanceThe connector interface is one of the most critical factors affecting transmission line operation. Even experienced technicians find the job more difficult when equipped with makeshift devices or an inad-equate array of simple hand tools, and it only takes a single faulty connection to degrade performance and threaten your operation’s revenues.

EASIAX® Plus Automated Cable Preparation ToolFor Reliable Cable Preparation in 10 Seconds

Cable­installers­and­system­designers­can­dramatically­reduce­cable­preparation­time­and­expense­while­improving­overall­system­perfor-mance­with­the­EASIAX­Plus­automated­cable­preparation­tool.­Fit­the­EASIAX­Plus­tool­to­any­standard­power­drill,­and­it­removes­the­cable­jacket,­outer­conductor,­and­foam,­then­cuts­back­and­chamfers­the­inner­conductor­to­the­correct­dimensions­for­connector­attach-ment—all­in­less­than­15­seconds.­The­EASIAX­Plus­automated­method­of­cable­preparation­means­cable­connections­that­are­more­consistent,­more­reliable,­and­­more­repeatable.

Tool Part Number Cable Type Connector TypeCPT-L1 LDF1-50 Standard connectors

CPT-E2L2N EFX2-50 Type N connectors

CPT-E2L2DIN EFX2-50 7-16 DIN connectors

CPT-E2L2N LDF2-50 Type N connectors

CPT-E2L2DIN LDF2-50 7-16 DIN connectors

CPT-F4 FSJ4-50B FSJ4 version two connectors

CPT-L4ARC1 LDF4-50 7-16 DIN or Type N standard, RingFlare™, HL4RP-50 OnePiece™, or Positive Stop™ connectors CPT-L45RC LDF4.5-50 RingFlare connectors

CPT-78U LDF5-50A 7-16 DIN or Type N standard, RingFlare, AVA5-50 OnePiece, or Positive Stop connectors VXL5-50 AL5-50

CPTL6 LDF6-50 7-16 DIN or Type N standard, RingFlare, OnePiece, or Positive Stop connectors

CPT-158U LDF7-50 7-16 DIN or Type N standard, RingFlare, AVA7-50 OnePiece, or Positive Stop connectors VXL7-50 AL7-50

Page 27: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Installation Aids

��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

Cable Types Cutting Tool Replacement Blades

Part Number Description Part Number, kit of 5 FSJ1, FSJ4, ETS1, RXL1* Series MCPT-1412 Cuts jacketing and outer conductor 209874FSJ2, FSJ4,ETS2 Series MCPT-3812 Cuts jacketing and outer conductor 209874LDF4, HL4RP-50A, RXL4** Series MCPT-L4 Cuts outer conductor and scores jacketing MCPT-BK4LDF5, VXL5, AVA5, RXL5, AL5-50 Series MCPT-78 Cuts outer conductor and inner conductor MCPT-BK5 and scores jacketingAVA5 A5MCPT-78 Cuts outer conductor and inner conductor A5MCPT-BK5

and scores jacketing­­

­ *­­Except­RXL1-1RNT­­

­ **­­Except­RXL4-(1,­2­or­3)­RNT

EASIAX® Cable Preparation ToolFor Fast, Precision Cuts in 15 Seconds

It’s Accurate

Cuts­precisely­at­crest­of­copper­corrugation­at­the­exact­distance­required­for­easy­connector­attachment.­Clean­cut­makes­flaring­easier­than­ever.­Precise­blade­depth­makes­it­impossible­to­cut­inner­conductor.

It’s Consistent

Every­cut­by­every­technician­on­every­interface­of­any­cable­will­be­exactly­the­same.­It’s­one­more­way­to­ensure­consistent­electrical­performance­for­your­cable­system.­EASIAX®­precision­cutting­tool­is­the­only­cutting­tool­made­exclusively­for­HELIAX®­coaxial­cable.

Remove­2”­­of­jacketing

MCPT-78 Rotation

Page 28: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Installation Aids

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

Connector Attachment Torque WrenchesPreset to Andrew Specifications

Andrew­torque­wrenches­attach­any­type­of­HELIAX®­connectors­to­HELIAX­LDF4.5,­LDF5,­LDF6,­LDF7,­and­LDF12­coaxial­cables.­All­are­designed­with­a­mechanism­to­audibly­notify­the­installer­that­the­proper­torque­has­been­reached­and­release­the­pressure.

Part Number Cable Type Connector Type 247696 LDF4-50A OnePiece™

245154 LDF4-50A RingFlare™

244376 LDF4.5-50 RingFlare and Standard244378 LDF5-50A, OnePiece, RingFlare, AVA5-50 and Standard and VXL5-50244375 LDF6-50 RingFlare and Standard247698 LDF6-50 LDF6 OnePiece only244374 LDF7-50A OnePiece, RingFlare and Standard244374 VXL7-50 OnePiece™, RingFlare™ and Standard244373 LDF12-50 Standard244379 All Type N coupling nut244377 All 7-16 DIN coupling nut247696 LDF4-50 OnePiece

Crimping ToolUsed­to­attach­crimp-on­lugs­for­standard­and­SureGround™­series.­Not­required­for­kits­having­factory-attached­lugs.

Part Number207270

Aluminum Grounding Kit ToolNow­installers­can­prepare­transmission­line­cable­for­grounding­kit­installation­in­one­simple,­precise­step—and­without­using­a­knife!­The­Andrew­aluminum­grounding­kit­preparation­tool­takes­just­seconds­to­use:­simply­snap­the­tool­in­place­around­the­cable­and­rotate.­In­one­step­the­tool­removes­the­exact­amount­of­jacketing­necessary­to­attach­the­grounding­strap.­The­grounding­kit­preparation­tool­is­a­manually­operated­cutting­device­that­quickly­trims­away­a­section­of­cable­jacket­for­the­purpose­of­grounding­strap­installation.­The­tool­is­ideal­for­use­on­cables­mounted­close­to­structures­and­other­cable­runs,­and­will­not­scrape­or­damage­the­cable’s­outer­conductor.

Part Number Cable Type Grounding Kit TypeGKT-F4A FSJ4 StandardGKT-L4A LDF4 Standard, CSGL, SGL,

and SGPL seriesGKT-78A LDF5, VXL5, AVA5, AL5 Standard, CSGL, SGL,

and SGPL seriesGKT-114A LDF6 Standard, CSGL, SGL,

and SGPL seriesGKT-158A LDF7, VXL7, AVA5, AL7 Standard, CSGL, SGL,

and SGPL seriesPart Number Replacement Blade KitGKT-F4A GKT-BKF4GKT-L4A GKT-BK512GKT-78A GKT-BK512GKT-114A GKT-BK67GKT-158A GKT-BK67

Page 29: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Installation Aids

�7Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

Description

Complete tool box kit includes all individual tools marked with an asterisk in the list below.

Manual cable preparation tool for 1/4" FSJ1-50 cableCut-off tool 7/32"Cut-off tool 8/32"Cut-off tool 9/32"

Manual cable preparation tool for 3/8" FSJ2-50 cableCut-off tool 7/32"Cut-off tool 8/32"Cut-off tool 9/32"

Automated/manual cable preparation tool for 1/2" coaxial superflexible cableManual cable preparation tool for 1/2" superflexible FSJ4-50B cable

Chamfer toolCut-off tool 7/32"Cut-off tool 8/32"Cut-off tool 9/32"

Automated/manual cable preparation tool for 1/2" coaxial cable21 mm torque wrench for L4 OnePiece™ connectors3/4" torque wrench for L4 RingFlare™ connectorsManual cable preparation tool for 1/2" LDF4-50A cable

Aluminum grounding kit stripping tool for LDF4 cableReplacement blade kit for grounding kit stripping tool for LDF4 cable

Manual cable preparation tool for 7/8" cableAutomated cable preparation tool for 7/8" cable1-1/4" torque wrench for 7/8" connectors1 -3/8" open end wrench for OnePiece™ 7/8" connectors, fits body of Positive Stop™ connectors1-1/4" open end wrench for 7/8" connectors, fits clamping nut of Positive Stop connectors Aluminum grounding kit stripping tool for 7/8" cableReplacement blade kit for plastic grounding kit stripping tool for 7/8" cable

Tool Part Number

TB-COMP-KIT

*MCPT-1412 224361 224362 244494

MCPT-3812 224361 224362 244494

CPT-F4

MCPT-1412

241953 224361 224362 244394

CPT-L4ARC1

247696 245154 MCPT-L4

GKT-L4A GKT-BK512

*MCPT-78 CPT-78U 244378 245516

244459-5

GKT-78AGKT-BK512

Cable Size

General Purpose

1/4"

3/8"

1/2" – F4

F4 and L4

1/2" – L4

7/8"

Attachment Tool KitsEasier Connections

The­connector­interface­is­one­of­the­most­critical­factors­affecting­transmission­line­operation.­Even­experienced­technicians­can­have­a­hard­time­when­equipped­with­makeshift­devices­or­an­inadequate­array­of­simple­hand­tools,­and­it­only­takes­a­single­faulty­connection­to­degrade­performance­and­threaten­your­operation’s­revenues.

Selection

The­table­is­designed­to­help­you­select­the­right­tools­for­each­cable­size.­Under­each­cable­size­you­will­find­a­list­of­part­numbers­for­the­appropriate­cable­preparation­tools,­cable­conditioning­tools,­spanner­and­torque­wrenches,­and­grounding­kit­preparation­tools.­

You’ll­have­the­option­of­selecting­a­manual­or­automated­cable­preparation­tool.­Under­the­indi-vidual­tools­you­will­find­the­torque­wrenches­for­the­connector­interface­nuts.

*This tool is included in the complete tool kit box, TB-COMP-KIT.

Page 30: Accessories for HELIAX Products--Product Selection Guide 2007

Cable Installation Accessories

Installation Aids

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

Description Manual cable preparation tool for 1-1/4" cableReplacement blade for CPTV2-114Automated cable preparation tool for 1-1/4" LDF6 cable1-7/8" torque wrench 1-1/4" standard or RingFlare™ connectors 1-3/4" torque wrench for 1-1/4" OnePiece™ connectorsAluminum grounding kit stripping tool for 1-1/4" cableReplacement blade kit for grounding kit stripping tool for 1-1/4" cable 1-7/8" open end wrench

Manual cable preparation tool for 1-5/8" cableReplacement blade for CPTV2-158Automated cable preparation tool for 1-5/8" cable2-1/4" torque wrench for 1-5/8" connectors2-1/4" open end wrench for 1-5/8" connectorsAluminum grounding kit stripping tool for 1-5/8" cableReplacement blade kit for grounding kit stripping tool for 1-5/8" cable

Type N coupling nut torque wrench 7-16 DIN coupling nut torque wrenchSafety knifeRulerGrease brushPoint filePin alignment toolCable flare tool LDF4Cable flare tool LDF5Cable flare tool LDF6Pin depth gauge, Type N malePin depth gauge, Type N femalePin depth gauge, 7–16 DIN malePin depth gauge, 7–16 DIN female

Tool Part NumberCPTV2-114 CPTV2-BK CPTL6 244375 247698 GKT-114A GKT-BK67 244459-6

CPTV2-158 CPTV2-BK CPT-158U 244374 244459-7 GKT-158A GKT-BK67

244379 244377 *224352 *224354 *224355 *224356 *224360 *224363 *224368 *224373 *224380 *224395 *114468 *114469

Cable Size1-1/4" cable

1-5/8"

Individual Tools

*This tool is included in the complete tool kit box, TB-COMP-KIT.

Page 31: Accessories for HELIAX Products--Product Selection Guide 2007

LIGH

TNIN

G PRO

TECTIO

N

( Grounding Kits

( Grounding Bars

( Surge Arrestors

Page 32: Accessories for HELIAX Products--Product Selection Guide 2007

Lightning Protection

Grounding Kits

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�0

Grounding Point 1

Grounding Point 4(Runs longer than 200 ft)

Grounding Point 2

Grounding Point 3

Transmission Line GroundingA well designed system uses grounding kits to provide a bond between the cable and the tower/earth ground system. One grounding kit is recommended at tower top, tower bottom, at 200 ft (60 m) intervals (where applicable), and at the entrance to the equipment shelter. Andrew solid copper grounding kits have passed United States Air Force lightning simulation tests and meet MIL-STD-188-124A. The non-braided solid copper construction of all Andrew grounding kits eliminates corrosion caused by moisture retention and “wicking.” A heat shrink tube protects the cable terminal connection.

(­Compact­SureGround™ (­SureGround™ (­Standard

Grounding Kit SelectionSeveral grounding kit options are available to meet the requirements of any transmission line grounding application.

d­­Compact SureGround™ grounding kits provide the fastest, easiest installation with the highest degree of lightning protection. Their self-sealing design clips and locks onto the cable in less than a minute.

d­­SureGround grounding kits, an industry favorite, offer clip on attachment with taped weatherproofing.

d­­Standard grounding kits provide the best grounding solution for elliptical waveguide. The copper grounding strap is coiled around the cable and weatherproofed with tape.

d­­Universal grounding kits can be applied to a broad range of coaxial or elliptical transmission lines.

Grounding Kit Selection Guide

Compact SureGround SureGround Standard UniversalKey Feature Over-molded weatherproof Preformed clip-on strap Wraparound grounding strap Multiple cable size design for easy, fast installation wraparound grounding strapBenefits Uniform installation compact Requires no tools Fits standard coaxial cable Breakaway design fits design for bundled installation for installation and elliptical waveguide multiple sizes of coaxial cable and elliptical waveguideInstallation Time Less than 1 minute About 3 minutes About 6 minutes About 7 minutesConstruction Preformed copper Pre-tensioned copper Copper grounding strap Copper grounding strap grounding strap grounding clip Over-molded weatherproof Standard weatherproofing Standard weatherproofing Standard weatherproofing boot, locking bail

Heavy Duty Ground Lead

Andrew­grounding­kits­use­heavy­duty­6­gauge­ground­leads­­to­maximize­performance.­The­MIL-STD-188-124B­compliant­copper­ground­lead­reduces­dc­resistance.­The­extremely­pliable­jacket­provides­protection­and­makes­it­easy­to­maneuver­the­lead­into­position­for­attachment­to­the­down­conductor.

d­­Solid­copper­construction­for­high­current­handling­capability,­­compatibility­with­copper­cable­outer­conductors

d­Meets­military­standards­at­commercial­prices.

d­­Provides­certainty­of­continued­operation,­tested­at­an­­independent­laboratory

Page 33: Accessories for HELIAX Products--Product Selection Guide 2007

Lightning Protection

Grounding Kits

��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

NEW! Compact SureGround™ Grounding KitsNow­wireless­communications­system­installers­and­designers­can­protect­their­systems­from­the­effects­of­lightning­easier­and­at­lower­cost.­The­new­Compact­SureGround­grounding­kit,­available­only­from­Andrew,­is­a­one-piece­grounding­assembly­with­the­weatherproofing­molded­right­into­the­grounding­strap.

Compact­SureGround­grounding­kit­features:

Easy attachment

d­­Self-locking,­self-sealing­weatherproof­enclosure­eliminates­­loose­hardware­and­taping

d­­Saves­up­to­an­hour­of­installation­time­per­typical­nine­run­site

Sure protection

d­­Largest­surface­contact­area­in­the­industry

d­­Provides­surety­of­protection­against­even­the­most­severe­­lightning­strikes

d­­Waterproof­to­IEC529,­IP68

Compact size

d­­“Clip­and­lock”­installation­ideal­for­tight­cable­bundles­­or­crowded­towers

d­­Exclusive­universal­grounding­lug­can­be­fitted­to­a­­one-­or­two-hole­earthing­attachment­point.

United­States­Patent:­6,548,762.­Other­patents­pending.

More Information

d­­See­Compact­Sureground­ordering­information­on­page­33

d­­See­the­installation­video­at­­www.andrew.com/products/trans_line/heliax/sureground.aspx

Easy Installation

Position­Compact­SureGround­grounding­kit

Clip­and­lock­­to­seal

SureGround™ KitsFast Installation, Complete Protection

Protect­your­equipment­from­the­effects­of­lightning­with­SureGround­grounding­kits.­Meeting­both­MIL­and­IEC­standards,­the­SureGround­self-securing­ground­strap­eliminates­the­need­for­attachment­tools­and­provides­protection­against­lightning­strikes­in­excess­of­100­kA.­Quality­non-braided­solid­copper­construction­prevents­moisture­retention­and­wicking,­while­a­heavy­duty­6­gauge,­MIL-STD-188-124B­compliant­copper­ground­lead­maximizes­performance.­Installation­is­fast,­easy,­and­error-free.­Grounding­kits­include­a­solid­copper­strap­riveted­to­the­grounding­wire,­tower­attachment­hardware,­and­a­two-part­tape­weatherproofing­system.­Grounding­kit­versions­are­available­with­a­tin­plating­for­compatability­with­aluminum­cables.United­States­Patent:­5,850,056.

The Compact SureGround Kit with integrated weatherproofing is the choice for the speediest installation, best fit in tight locations, and long-term protection.

TIP!

TIP!

Completed

Page 34: Accessories for HELIAX Products--Product Selection Guide 2007

Lightning Protection

Grounding Kits

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

Connector Grounding Kit for Mounting RailPart Number DescriptionCGT12 Connector grounding kit fits all F4 and L4 (except OnePiece™)

series connectorsCGT58 Connector grounding kit fits all L4.5 and L5

standard connectorsCGT78 Connector grounding kit fits all L5, V5, A5, OnePiece,

and Positive Stop™ series connectorsCGT114 Connector grounding kit fits all L6 series connectorsCGT158 Connector grounding kit fits all L7 and V7

series connectorsCGT214 Connector grounding kit fits all L12 series connectors

40 mm x 22 mm x 17 mm

Universal Grounding LugsThis­grounding­lug­provides­you­with­the­option­of­a­one-hole­configuration­or­two-hole­configuration.­Just­break­away­the­bottom­portion­of­the­lug­and­this­will­give­you­your­one-hole­lug.­This­universal­lug­will­fit­common­buss­bar­configurations­with­two-hole­spacings­of­0.750,­0.815,­or­1.0­in.­Designed­to­crimp­on­6­gauge­or­16­mm2­grounding­wire.­Included­on­all­grounding­kits­and­available­separately.­

Part Number Description 245529-10 Universal grounding lug, kit of 10 207136-3 Grounding lug hardware kit

Standard Grounding KitsEasy Installation for System Protection

Standard­grounding­kits­are­traditional­solutions­for­lightning­protection­and­are­also­well­suited­for­elliptical­waveguide­installations.­One­grounding­kit­is­recommended­at­the­tower­top,­tower­bottom,­at­200­ft­(60­m)­intervals,­and­at­the­entrance­to­the­equipment­shelter.­Standard­grounding­kits­(204989­and­241088­series)­require­few­steps­to­install­and­include­easy-to-follow­instructions.­Proper­tensioning­is­ensured­by­an­expansion­section­that­provides­visual­indication­that­the­strap­is­secured.

Series­204989­and­241088­kits­include­a­solid­copper­strap­riveted­to­the­grounding­wire,­coiling­tool­for­proper­tightening,­universal­grounding­lug,­tower­attachment­hardware,­and­a­two-part­tape­weath-erproofing­system.­Field-attachable,­crimp-on­grounding­lugs­require­a­crimping­tool­(not­included).­

For­two­bolt­grounding

Snap­off­pre-scored­­lug­for­one­hole­option

For­one­bolt­grounding

Crimping Tool for SureGround™ and Standard Grounding The­crimping­tool­is­used­to­attach­crimp-on­lugs­for­standard­and­SureGround­series­grounding­kits.­Not­required­for­kits­with­factory­attached­lugs.

Part Number Description 207270 Crimping tool, quantity 1

Universal Grounding KitPart Number DescriptionUG12158-15B4 1/2"–1-5/8" EW180–EW63 60" field attached lug

Page 35: Accessories for HELIAX Products--Product Selection Guide 2007

Lightning Protection

Grounding Kits

��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

Compact SureGround™

24 in 36 in 60 in

Size/Type 600 mm 1 meter 1.5 meters factory attached lug field attached lug

1/2" LDF4 black CSGL4-06B2 CSGL4-10B2 CSGL4-15B41/2" LDF4 gray CSGL4-06S2 CSGL4-10S2 CSGL4-15S47/8" black CSGL5-06B2 CSGL5-10B2 CSGL5-15B47/8" gray CSGL5-06S2 CSGL5-10S2 CSGL5-15S41-1/4" black CSGL6-06B2 CSGL6-10B2 CSGL6-15B41-1/4" gray CSGL6-06S2 CSGL6-10S2 CSGL6-15S41-5/8" black CSGL7-06B2 CSGL7-10B2 CSGL7-15B41-5/8" gray CSGL7-06S2 CSGL7-10S2 CSGL7-15S4

SureGround™

Size/Type 600 mm 1 meter 1.5 meters factory attached lug field attached lug

1/2" LDF4 black SGL4-06B2 SGL4-10B2 SGL4-15B41/2" LDF4 gray SGL4-06S2 — —5/8" black SGL45-06B2 SGL45-10B2 SGL45-15B47/8" black SGL5-06B2 SGL5-10B2 SGL5-15B47/8" gray SGL5-06S2 — —7/8" aluminum cable SGL5-06B2-T — SGL5-15B4-T1-1/4" black SGL6-06B2 SGL6-10B2 SGL6-15B41-1/4" gray SGL6-06S2 — —1-5/8" black SGL7-06B2 SGL7-10B2 SGL7-15B41-5/8" gray SGL7-06S2 — —1-5/8" aluminum cable SGL7-06B2-T — SGL7-15B4-T2-1/4" SGL12-06B2 SGL12-10B2 SGL12-15B4

Standard Grounding Kit

Size/Type 24" in 36" in 60" in factory attached lug field attached lug

1/4" and 3/8", EW240, EW380 223158-2 223158-3 223158-41/2", EW180, EW220 241088-1 241088-6 2415455/8" and 7/8", EW85, EW90, EW127A, EW132 241088-2 241088-7 2204971-1/4", EW64, EW77 241088-3 241088-8 241088-601-5/8", EW52, EW63 241088-4 241088-9 220498EW43 204989-10 241088-64 204989-282-1/4" and 3", EW28, EW37 241088-5 241088-10 223700-7244", EW17, EW20 204989-6 — —

Universal Grounding Kit

Size/Type 60" field attached lug

1/4"–5/8" (Cinta™, HELIAX®) — — GK-SUNV

Universal Connector Grounding Kit

Part Number Description

244495 Universal connector grounding kit

Page 36: Accessories for HELIAX Products--Product Selection Guide 2007

Lightning Protection

Grounding Bars

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

Ground Buss BarsAndrew offers a complete range of grounding buss bar sizes and hole pattern configurations to accommodate just about any application. Each grounding bar is made from 1/4 in solid copper bar stock and is available with optional tin plating. Kits come complete with insulators, stainless steel brackets, adapters, and hardware for mounting to a wall or tower.

2" Ground Buss Bar Kits Part Number Description

2" x 10" Ground Buss Bar Kits

Bare Copper

UGBKIT-0210 Universal ground buss bar kit, 1/4" x 2" x 10" (6.4 mm x 50.8 mm x 254.0 mm) with universal buss bar hardware kit

Tinned Copper

UGBKIT-0210-T Universal tinned ground buss bar kit, 1/4" x 2" x 10" (6.4 mm x 50.8 mm x 254.0 mm) with universal buss bar hardware kit

2" x 12" Ground Buss Bar Kits

Bare Copper

UGBKIT-0212 Universal ground buss bar kit, 1/4" x 2" x 12" (6.4 mm x 50.8 mm x 304.8 mm) with universal buss bar hardware kit

Tinned Copper

UGBKIT-0212-T Universal tinned ground buss bar kit, 1/4" x 2" x 12" (6.4 mm x 50.8 mm x 304.8 mm) with universal buss bar hardware kit

7/16" x 5/8"(11.1 mm x 15.9 mm)

7/16"(11.1 mm)

2" (50.8 mm)

1/2"(12.7 mm)

3/4"(19.1 mm) 10"

(254 mm)

7/16"(11.1 mm)

12"(304.8 mm)

2"(50.8 mm)

1/2"(12.7 mm)

2" x 14" Ground Buss Bar Kits

Bare Copper

UGBKIT-0214 Universal ground buss bar kit, 1/4" x 2" x 14" (6.4 mm x 50.8 mm x 355.6 mm) with universal buss bar hardware kit

Tinned CopperUGBKIT-0214-T Universal tinned ground buss bar kit, 1/4" x 2" x 14" (6.4 mm x 50.8 mm x 355.6 mm) with universal buss bar hardware kit

2-1/2" Ground Buss Bar Kits Part Number Description

2-1/2" x 12-1/2" Ground Buss Bar Kits

Bare Copper

UGBKIT-2 Universal ground buss bar kit, 1/4" x 2-1/2 x 12-1/2 (6.4 mm x63.5 mm x 317.5 mm) with universal buss bar hardware kit

Tinned Copper

UGBKIT-2T Universal tinned ground buss bar kit, 1/4" x 2-1/2" x 12-1/2" (6.4 mm x 63.5 mm x 317.5 mm) with universal buss bar hardware kit

13/16"(20.6 mm)

7/16"(11.1 mm)

1-1/4" (31.8 mm)

1-3/8" (34.9 mm)

12-1/2" (317.5 mm)

1" (25.4 mm)

1" (25.4 mm)

2-1/2" (63.5 mm)

7/16"(11.1 mm)

1/2"(12.7 mm)

2" (50.8 mm)

14"(355.6 mm)

3/4" (19.1 mm)

7/16" x 5/8"(11.1 x 15.9 mm)

(­UGBKIT

Page 37: Accessories for HELIAX Products--Product Selection Guide 2007

Lightning Protection

Grounding Bars

��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

2-1/2" x 19-1/2" Ground Buss Bar Kits

Bare Copper

UGBKIT Universal ground buss bar kit, 1/4" x 2-1/2" x 19-1/2" (6.4 mm x 63.5 mm x 495.3 mm) with universal buss bar hardware kit

Tinned Copper

UGBKIT-T Universal tinned ground buss bar kit, 1/4" x 2-1/2" x 19-1/2" (6.4 mm x 63.5 mm x 495.3 mm) with universal buss bar hardware kit

4" Ground Buss Bar Kits Part Number Description

4" x 12" Ground Buss Bar Kits

Bare Copper

UGBKIT-0412 Universal ground buss bar kit, 1/4" x 4" x 12" (6.3 mm x 101.6 mm x 304.8 mm) with universal buss bar hardware kitTinned Copper

UGBKIT-0412-T Universal tinned ground buss bar kit, 1/4" x 4" x 12" (6.3 mm x 101.6 mm x 304.8 mm) with universal buss bar hardware kit

7/16"(11.1 mm)

12"(304.8 mm)

4" (101.6 mm)

1/2" (12.7 mm) 3/4" (19 mm)

7/16" x 5/8"(11.1 mm x 15.9 mm)

7/16"(11.1 mm)

13/16"(20.6 mm)

2-1/2"(63.5 mm) 1" (25.4 mm)

1-3/8" (34.9 mm)

19-1/2"(495.3 mm)

1-1/4" (31.8 mm)

4" x 14" Ground Buss Bar Kits

Bare Copper

GBKIT-0414 Universal ground buss bar kit, 1/4" x 4" x 14" (6.3 mm x 101.6 mm x 355.6 mm) with universal buss bar hardware kit.

Tinned Copper

UGBKIT-0414-T Universal tinned ground buss bar kit, 1/4" x 4" x 14" (6.3 mm x 101.6 mm x 355.6 mm) with universal buss bar hardware kit.

(11.1 mm)

(355.6 mm)

(12.7 mm)(12.7 mm)

4" (101.6 mm)

1-1/2" (38.1 mm)

(6.4 mm)(11.1 mm x 15.9 mm)

(­UGBKIT-0210

(­UGBKIT-0412

Page 38: Accessories for HELIAX Products--Product Selection Guide 2007

Lightning Protection

Grounding Bars

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

4" x 20" Ground Buss Bar Kits

Bare Copper

UGBKIT-0420 Universal ground buss bar kit, 1/4" x 4" x 20" (6.3 mm x 101.6 mm x 508.0 mm) with universal buss bar hardware kit.

Tinned Copper

UGBKIT-0420-T Universal tinned ground buss bar kit, 1/4" x 4" x 20" (6.3 mm x 101.6 mm x 508.0 mm) with universal buss bar hardware kit.

4" x 24" Ground Buss Bar Kits

Bare Copper

UGBKIT-0424 Universal ground buss bar kit, 1/4" x 4" x 24" (6.3 mm x 101.6 mm x 609.6 mm) with universal buss bar hardware kit.

Tinned Copper

UGBKIT-0424-T Universal tinned ground buss bar kit, 1/4" x 4" x 24" (6.3 mm x 101.6 mm x 609.6 mm) with universal buss bar hardware kit.

7/16" x 5/8"(11.1 mm x 15.9 mm)7/16"

(11.1 mm)

4" (101.6 mm)

20"(508 mm)

3/4"(19 mm)

1-3/4"(44.5 mm)

7/16" x 5/8"(11.1 mm x 15.9 mm)7/16"

(11.1 mm)

4" (101.6 mm)

20"(508 mm)

3/4"(19 mm)

1-3/4"(44.5 mm)

Universal Arrestor Ground Bar AssemblyThis­pre-punched­solid­copper­ground­bar­assembly­simplifies­mounting­and­grounding­of­surge­arrestors­inside­the­building.­Instead­of­relying­on­individual­wires­or­field-fabricated­trapeze­setups,­the­Andrew­universal­arrestor­ground­bar­assembly­provides­a­uniform­mounting­and­grounding­point­for­surge­arrestors­and­grounding­leads.­The­1/8­in­assembly­uses­three­horizontal­members­that­can­be­oriented­flat­or­upright­and­adjusted­vertically­as­needed­to­accommodate­various­surge­arrestor­types.­Also­included­is­a­mounting­kit­that­includes­ceiling­brackets,­insulators,­threaded­rod,­and­hardware.­

d­Compatible­with­standard­entry­port­sizes

d­Height-adjustable­bars

d­Solid­copper­construction

d­Accepts­bulkhead­or­bolt­grounded­surge­arrestors

d­Accommodates­one-­and­two-hole­grounding­lugs

d­Eliminates­need­for­internal­buss­bar

Part Number DescriptionUGBA-DIN-36 Three 6-position ground bars punched for oversized

7-16 DIN mount arrestors (APTL and APT series) or bolt-grounded arrestors

UGBA-36 Three 6-position ground bars punched for most 7-16 DIN, Type N or bolt-grounded arrestors (Andrew APG and APM series arrestors)

UGBA-DIN-34 Three 4-position ground bars punched for oversized 7-16 DIN mount arrestors (APTL and APT series) or bolt-grounded arrestors

UGBA-34 Three 4-position ground bars punched for most 7-16 DIN, Type N, or bolt-grounded arrestors (Andrew APG and APM series arrestors)

Page 39: Accessories for HELIAX Products--Product Selection Guide 2007

Lightning Protection

Surge Arrestors

�7Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

T-SeriesDual­Band

dc­PassDual­Band

Replaceable­­Gas­Tube

dc­BlockIntegrated Bias­Tee

T-Series Surge Arrestors Arrestor­Plus®­T-series­surge­arrestors­give­engineers­more­flex-ibility­when­configuring­lightning­protection­systems.­This­slim­profile­arrestor­fits­easily­inside­equipment­enclosures,­is­bi-directional,­and­offers­true­multistrike­protection.­The­arrestor­plus­bulkhead­mount­T-series­features­universal­Type­N­and­7-16­DIN­interfaces.­The­dc­passing­version­allows­current­to­travel­to­the­top­of­the­tower.

Arrestor Plus® Lightning Surge Arrestors Add the final measure of protection to your equipment from lightning current traveling down the transmission line with Arrestor Plus surge arrestors. All designs are completely weatherproof and feature low return, insertion loss, and low intermodulation. Our wide range of surge arrestor types and configurations support most applications.

Replaceable Gas Tube Surge ArrestorsOffering­broadband­performance­from­0–2200­MHz­and­excellent­elec-trical­characteristics,­Arrestor­Plus­replaceable­gas­tube­surge­arrestors­are­easy­to­install,­are­bidirectional,­and­feature­dc­pass­capability­through­the­center­conductor­to­the­active­tower­top­electronics.­The­unit’s­removable­cap­makes­periodic­maintenance­fast­and­easy.­­

45–2200 MHz, 90 VAPG-BDFDF-090APG-BDFDM-090APG-BNFNF-090APG-BNFNM-090

45–2200 MHz, 350 VAPG-BDFDF-350APG-BDFDM-350APG-BNFNF-350APG-BNFNM-350

824–960 MHz and 1710–2170 MHz

APT-DFDF-DBAPT-DFDM-DBAPT-BDFDF-DBAPC-BDFDM-DBAPT-BDFDM-DBAPT-NFNF-DBAPT-NFNM-DBAPT-BNFNF-DBAPT-BNFNM-DB

824–960 MHz and 1710–2170 MHz dc Passing

APTDC-BDFDF-DBAPTDC-BDFDM-DBAPTDC-BNFNM-DB

380–520 MHz

APC-BDFDM-450

675–825 MHz

APC-BDFDM-700

2000–2800 MHz

APB-BNFNF-2400

Page 40: Accessories for HELIAX Products--Product Selection Guide 2007

Bias Tee Andrew­bias­tees­are­designed­to­protect­equipment­from­damaging­transients­induced­by­lightning­strikes.­This­product­allows­the­injec-tion­of­dc­current­to­the­center­conductor­of­the­feeder­line,­allowing­current­to­travel­to­the­top­of­the­tower.­Bias­tees­are­unidirectional­devices.­Ports­are­clearly­marked­to­show­mounting­direction­with­either­“Antenna”­or­“Radio”.

824–960 MHz and 1710–2170 MHzABT-DFDM-ADBHABT-DFDM-DBABT-DMDF-ADBHABT-DMDF-DBABT-NFNM-DBABT-NMNF-DB

dc BlockThe­dc­block­is­designed­to­block­dc­signals­from­passing­through­the­center­conductor­of­a­coaxial­transmission­line.­The­dc­block­is­a­bidi-rectional­RF­device.­Either­RF­port­may­be­connected­to­the­equipment­side­or­the­antenna­side­of­the­transmission­line­interface­to­provide­equivalent­protection.

824–960 MHz and 1710–2170 MHzADCB-DFDM-DB

Integrated Surge Arrestor/ConnectorThe­Arrestor­Plus®­integrated,­T-series­lightning­surge­arrestor­is­a­one-piece­surge­arrestor/HELIAX®­connector.­It­uniquely­combines­the­reli-ability­of­quarterwave­shorting­stub­technology­with­the­proven­perfor-mance­of­HELIAX­connectors­to­deliver­premium­lightning­protection­in­a­single­component.

824–960 MHz and 1710–2170 MHzAPTA5DC-BDF-DBAPTA7DC-BDF-DB

Surge Arrestor AccessoriesPart Number DescriptionGASTUBE-090 90 volt gas tube replacement, kit of 10GASTUBE-350 350 volt gas tube replacement, kit of 10243951 90 degree mounting/grounding bracket, Type N243950 90 degree mounting/grounding bracket, 7–16 DIN244847 Integrated surge arrestor/connector 90 degree

mounting/grounding bracket, 7–16 DINDF-CAPKIT Plated port sealing cap, 7–16 DIN (Fits onto DIN female

connector), IP 66 and 68

Lightning Protection

Surge Arrestors

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

Page 41: Accessories for HELIAX Products--Product Selection Guide 2007

APPEN

DIXES

Page 42: Accessories for HELIAX Products--Product Selection Guide 2007

Appendix �

Quarterwave Stub Surge Arrestors

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�0

Quarterwave Stub Surge Arrestors—Considerations and SelectionQuarterwave Stub (QWS) Surge Arrestor Technology

An­understanding­of­the­key­concepts­of­quarterwave­stub­tech-nology­and­its­relationship­to­lightning­transients­can­be­of­great­benefit­to­transmission­line­system­designers­and­operators.­With­this­understanding,­system­designers­and­operators­can­more­fully­utilize­lightning­protection­systems­that­use­QWS­technology­as­well­as­understand­the­critical­role­multistrike­ability­plays­in­light-ning­protection­systems.

Arrestor­Plus®­T-series­surge­arrestors­from­Andrew­Corporation­employ­QWS­technology,­a­unique­design­that­allows­microwave­signals­to­pass­unattenuated­while­shunting­the­lower­frequencies­associated­with­lightning-induced­transients­to­ground.­This­proven­QWS­technology­is­utilized­in­APT­Arrestor­Plus®­Surge­Arrestors.

To­understand­QWS­technology,­one­needs­to­understand­lightning.­­The­lightning­transient­is­characterized­by­a­current­waveform­with­an­8-microsecond­rise­time­(time­to­reach­90%­of­the­peak­value)­and­a­20-microsecond­decay­time­(time­to­decay­to­50%­of­the­peak­value).­Peak­currents­can­reach­excessive­values,­but­50%­of­all­strikes­will­reach­values­of­only­18­kA.­It­is­important­to­remember­that­this­is­only­a­laboratory­characterization­of­the­lightning­transient,­but­it­facilitates­standardized­testing­techniques­for­the­industry.­Figure­1­depicts­an­actual­laboratory-generated­8/20­µsec­waveform­that­was­used­to­evaluate­Andrew­surge­arrestors.­For­more­detailed­information­regarding­laboratory­generated­surge­waveforms,­see­IEC­60-2,­ANSI-IEEE­Std­4-1978,­and­ANSI­C62.1-1984.

The­substantial­energy­associated­with­lightning­transients­has­frequency­components­near­dc­with­components­of­decreasing­value­of­energy­extending­through­160­kHz.

The­effectiveness­of­surge­arrestors­is­characterized­by­the­throughput­energy­and­the­ability­to­withstand­multiple­surges.­These­characteristics­are­readily­measurable­in­a­laboratory­equipped­with­the­appropriate­test­equipment.­Throughput­energy­is­a­measure­of­the­amount­of­energy­passed­through­the­output­of­the­device­when­the­input­of­the­device­is­subjected­to­a­light-ning­transient­waveform.­The­throughput­energy­can­be­calculated­from­the­residual­voltage­waveform­using­the­relationship:

Figure­2­shows­the­residual­output­voltage­present­when­an­APT­Series­Surge­Arrestor­was­subjected­to­an­actual­8/20­µsec­waveform­with­a­peak­current­of­20­kA.­In­this­case,­the­residual­voltage­was­recorded­across­a­50­ohm­load.­The­resulting­throughput­energy­was­72­microjoules.­The­objective­of­the­surge­arrestor­is­to­minimize­the­throughput­energy­to­a­manageable­level.­Most­microwave­transmitters­and­receivers­used­in­today’s­wireless­systems­are­capable­of­withstanding­throughput­energy­levels­of­10­millijoules­or­less.

The­ability­to­withstand­multiple­strikes­is­also­an­important­measure­of­surge­arrestor­merit.­Multistrike­ability­is­measured­by­subjecting­the­QWS­surge­arrestors­to­repeated­surges­and­observing­if­the­arrestors­continue­to­properly­function­or­show­

Time (microseconds)Figure 1

Time (microseconds)Figure 2

Laboratory generated 8 x 20 µsec lightning surge current waveform.Peak current: 21 kiloamperes

Residual output voltage of an APT quarterwave stub surge arrestor when subjected to an 8 x 20 µsec current surge with peak current of 20,000 amperes.

Page 43: Accessories for HELIAX Products--Product Selection Guide 2007

Appendix �

Quarterwave Stub Surge Arrestors

��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

signs­of­degradation.­No­evidence­of­failure­or­degradation­was­observed­after­subjecting­the­Andrew­Arrestor­Plus®­surge­arres-tors­to­over­100­strikes­at­50­kA­peak­current­using­an­8/20­µsec­waveform.­This­level­of­reliability­is­essential­in­protecting­today’s­telecommunications­systems­from­the­potential­of­damaging­light-ning­transients.­

Arrestor­Plus­QWS­surge­arrestors­are­carefully­designed­and­tested­to­provide­a­low­impedance­path­to­ground­for­any­lightning­induced­transient­energy­present­on­the­center­conductor­of­the­transmission­line.­These­surge­arrestors­are­designed­to­withstand­multiple­strikes­of­the­most­severe­surges.­The­unique­attributes­of­QWS­surge­arrestors­are­made­possible­by­careful­design­and­selection­of­the­geometry­and­cross-sectional­area­of­the­conductors­that­make­up­the­shorting­stub.­QWS­designs­result­in­extremely­low­throughput­energy­devices­with­true­­multistrike­ability.

When­selecting­a­surge­arrestor,­the­RF­performance­must­be­considered.­Characteristics­that­describe­RF­performance­are­operating­bandwidth,­VSWR­(return­loss),­insertion­loss,­maximum­average­power,­and­passive­intermodulation­distortion.

The­operating­bandwidth­of­quarterwave­shorted­stubs­is­limited,­but­Andrew­Arrestor­Plus­QWS­surge­arrestors­are­designed­to­accommodate­the­operating­bandwidth­requirements­of­today’s­wireless­telecommunications­systems.­Quarterwave­shorted­stubs­can­be­designed­to­accommodate­up­to­20%­bandwidth.­The­bandwidth­characteristics­of­the­surge­arrestors­is­similar­to­that­of­a­bandpass­filter:­RF­signals­at­the­center­of­the­band­pass­unat-tenuated,­while­out-of-band­signals­(such­as­lightning­transients)­are­diverted­harmlessly­to­ground.­

Figure­3­shows­the­measured­wideband­S11­(return­loss)­of­a­QWS­surge­arrestor.­Note­that­in­the­band­of­interest,­the­S11­levels­are­typically­-30­dB.­

It­is­key­to­note­that­dc­signals­cannot­be­passed­through­the­device.­When­dc­passing­is­required,­as­is­often­the­case­for­tower­top­active­electronics,­then­it­is­strongly­recommended­to­use­Andrew­APG­gas­tube­series­surge­arrestors.­For­more­information­on­APG­gas­tube­series­arrestors,­see­Appendix­2.­

The­lowest­center­frequency­of­operation­is­limited­to­approxi-mately­400­MHz,­while­the­highest­center­frequency­is­limited­by­the­cutoff­frequency­of­the­coaxial­cable­being­used.­Figure­4­shows­a­cross-sectional­view­of­a­QWS­surge­arrestor.­The­lower­operating­frequency­is­limited­due­to­the­physical­size­of­the­shorting­stub.­When­the­shorting­stub­reaches­too­long­of­a­physical­length,­the­stub­appears­as­an­inductive­load,­resulting­in­excessive­residual­voltages.­Quarterwave­shorted­stubs­can­be­designed­to­accommodate­systems­operating­as­high­as­12­GHz.

Frequency (MHz)Figure 3

Figure 4

S11 vs Frequency for a QWS surge arrestor

In­the­operating­bandwidth­of­the­Arrestor­Plus®­QWS­surge­arrestors,­the­RF­performance­characteristics­are­optimal.­At­the­operating­frequencies­of­the­Arrestor­Plus,­the­insertion­loss­is­less­than­0.1­dB,­no­more­than­adding­a­connector­to­the­transmission­line­path.­Figure­5­shows­the­measured­S21­(insertion­loss)­perfor-mance­of­an­APM­type­QWS­surge­arrestor.­Note­that­in­the­band­of­interest,­the­S21­levels­are­better­than­-0.05­dB.

The­maximum­average­operating­power­of­the­Arrestor­Plus­QWS­surge­arrestor­is­limited­by­the­connector­interface.­The­suggested­maximum­average­operating­power­for­Type­N­connectors­is­600­watts­at­900­MHz.­The­suggested­maximum­average­operating­power­for­7-16­DIN­connectors­is­3000­watts­at­900­MHz.­Exceeding­these­values­can­result­in­excessive­temperature­rise­and­permanent­damage­to­the­device.­

Intermodulation­distortion­(IMD)­is­a­major­concern­in­today’s­PCS,­cellular,­ESMR,­and­other­wireless­systems.­IMD­is­caused­by­nonlinear­effects­within­a­device.­For­connectors,­these­nonlinear­effects­can­be­caused­by­poor­contact­between­internal­surfaces,­plating­with­ferrous­materials,­such­as­nickel,­or­by­oxide­build­up­between­contact­surfaces.­

Page 44: Accessories for HELIAX Products--Product Selection Guide 2007

Appendix �

Quarterwave Stub Surge Arrestors

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

Arrestor­Plus®­surge­arrestors­are­designed­with­high­pressure­contacts,­premium­platings,­and­are­compensated­to­offer­the­best­possible­IMD­performance.

The­functionality­of­Arrestor­Plus­QWS­surge­arrestors­can­be­readily­evaluated­by­using­ordinary­RF­field­test­equipment.­If­there­is­no­degradation­of­the­VSWR­or­insertion­loss­of­the­arrestor,­then­the­surge­arrestor­is­reassuringly­functioning­as­a­transient­lightning­protection­device.­VSWR­and­insertion­loss­measurements­can­be­made­by­using­vector­or­scalar­network­analyzers­as­well­as­a­variety­of­other­readily­available­field­test­equipment.­No­other­maintenance­is­required.­As­obvious­as­it­may­seem,­surge­arres-tors­should­never­be­installed­or­tested­when­a­storm­is­occurring­or­approaching.

System­requirements­often­dictate­outdoor­installation­of­surge­arrestors.­Arrestor­Plus­surge­arrestors­are­ideal­for­these­applica-tions­and­designed­to­withstand­the­harshest­environments­and­are­extensively­tested­to­meet­industry­standard­specifications­for­waterproofing,­vibration,­thermal­cycling,­mechanical­shock,­salt­spray,­fungus,­and­moisture­resistance.

QWS­surge­arrestors­are­excellent­choices­for­wireless­base­station­applications­where­superior­RF­performance­is­required­to­ensure­call­quality­and­when­protection­against­multiple­lightning­strikes­is­of­primary­importance.

Frequency (MHz)Figure 5

S21 vs Frequency for a QWS surge arrestor

Page 45: Accessories for HELIAX Products--Product Selection Guide 2007

Appendix �

Gas Tube Surge Arrestors

��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

Using the Maximum Average Power Derating Curves GSM Radio Operating Conditions:

1.­Number­of­carriers­=­22.­­Power­of­each­carrier­(dBm)­=­+42­dBm­carriers­at­the­output­

of­a­hybrid­combiner­(+45­dBm­at­combiner­input)3.­VSWR­=­1.25:14.­dc­Bias­=­15­V5.­Nominal­Impedance­=­50­Ω

Gas Tube Surge Arrestors—Considerations and SelectionGas Tube Surge Arrestor Technology To­simplify­selecting­the­appropriate­gas­tube­surge­arrestor­for­your­system­plots,­maximum­average­power­vs.­VSWR­have­been­compiled.­Figures­1­and­2­show­plots­of­maximum­average­power­vs.­VSWR­for­90­and­350­volt­gas­tubes.­Each­graph­shows­different­values­of­commonly­used­dc­bias­voltages.­These­graphs­were­established­from­extensive­laboratory­testing­and­include­the­appropriate­safety­factors­to­ensure­proper­gas­tube­selection.­Using­these­graphs­for­selecting­a­gas­tube­will­optimize­the­level­of­protection­required­for­your­system.

Gas­tube­elements­are­offered­in­various­spark-over­voltages.­Andrew­Corporation­simplifies­the­selection­process­by­limiting­the­choice­to­two­options,­90­volt­for­GPS­applications­and­350­volt­for­many­other­wireless­applications­requiring­a­dc­bias.­Plots­of­maximum­average­power­vs.­VSWR­have­been­compiled­for­the­90­and­350­volt­gas­tubes­from­extensive­laboratory­testing­and­have­built-in­safety­factors­to­ensure­proper­selection.­See­figures­3­and­4.­Each­graph­shows­several­different­values­of­commonly­used­dc­bias­voltages.­Using­these­graphs­for­selecting­a­gas­tube­will­optimize­the­level­of­protection­required­for­your­system.­

When­working­in­today’s­environment­of­diplexed­signals,­overlaid­networks,­tower­mounted­amplifiers,­and­multiple­carriers,­it­is­necessary­to­verify­that­a­system’s­maximum­average­power­does­not­exceed­that­rating­for­the­gas­tube.­The­following­example­illus-trates­the­process­of­using­the­voltage­derating­curves­that­follow.

1. Calculate the peak instantaneous voltage of a single +42 dBm carrier for a 50 ohm based system

AveragePower10

(averagepowerpercarrierindBm/10) perCarrier(watts)=

1000

Vrmspercarrier(volts):= √ averagepowerpercarrier(watts)•Impedance(ohms)

Vrmspercarrier(volts)=28.284

Vpeakpercarrier(volts):=√2•Vrmspercarrier(volts)

Vpeakpercarrier(volts)=40

Therefore, the peak instantaneous voltage of a single +42 dBm carrier is 40 volts.

2. Calculate the peak instantaneous voltage of a two, +42 dBm carrier, 50 ohm based system

Peakinstantaneousvoltage(volts):= Vpeakpercarrier(volts)•numberofcarriers(N)

Peakinstantaneousvoltage(volts)=80

Therefore, the peak instantaneous voltage of a two +42 dBm carriers is 80 volts.

3. Calculate the peak instantaneous power of two, +42 dBm carrier, 50 ohm based system

Peakinstantaneouspower(watts):= (Peakinstantaneousvoltage(volts))2

Impedance(ohms)

Peakinstantaneouspower(watts)=128

Peakinstantaneouspower(dBm):=

10•log

Peakinstantaneouspower(watts) 0.001

Peakinstantaneouspower(dBm)=51.072

Therefore, the peak instantaneous voltage of two, +42 dBm carriers is 128 watts (+51 dBm).

4. The gas tube selection curves are specified as Maximum Average Power vs. VSWR. Therefore, it is required to calculate an estimate of the average (RMS) power from the peak instantaneous power. A reasonable calculation of this estimate is shown below:

Peakinstantaneousvoltage(volts)=80

RMSequivalent(volts):=Peakinstantaneousvoltage(volts)

√2

RMSequivalent(volts)=56.569

RMSequalpower(watts):=(RMSequivalent(volts))2

Impedance(ohms)

RMSequalpower(watts)=64

Therefore, to utilize the gas tube selection curves, an approximate value of 64 watts average power would provide a reasonable estimate.

Note that for this calculation, the dc bias voltage was not specified and the VSWR was not specified. The gas tube selection curves provide a derating for both the VSWR and dc bias voltage.

5. Apply calculated information to the derating curves.

Page 46: Accessories for HELIAX Products--Product Selection Guide 2007

Appendix �

Gas Tube Surge Arrestors

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

1.25

Vdc bias 15 V

3.25 W

Steps

1.­Apply­system­parameters­to­90­V­curves.

2.­Estimate­15­V­dc­bias­line

3.­Find­average­power­level­at­intersection­with­1.25­VSWR

4.­Average­power­=­3.25­W

5.­­3.25­W­is­much­less­than­64­W­therefore­90­V­gas­tube­is­not­chosen­for­this­application.

6.­Move­on­to­350­V­curve.

Steps

1.­­Locate­maximum­average­power­for­system­with­VSWR­=­1.25­and­Vdc­=­15­V­as­before.

2.­Maximum­average­power­(est.)­=­375­W­(+55.74­dBm)

3.­­Estimated­average­power­(from­calculation)­=­64­W­­(+48.06­dBm)

4.­Resulting­safety­margin­is­7.68­dB.

5.­­350­V­gas­tube­is­chosen­due­to­acceptable­safety­margin.

The­APTDC­line­of­dc­passing­surge­arrestors­should­be­used­for­those­cases­where­the­intersection­of­VSWR­and­Maximum­Average­Power­lie­above­the­0­volt­dc­offset­curve.­

375 W

Vdc bias 15 V

Gas Tube Derating Curves

90 VoltFigure 3

350 VoltFigure 4

VSWRFigure 1

Derating of maximum average power due to VSWR and applied dc bias for APG Arrestor Plus® surge arrestors with 90 volt gas tubes

VSWRFigure 2

Derating of maximum average power due to VSWR and applied dc bias for APG Arrestor Plus® surge arrestors with 90 volt gas tubes

Derating of maximum average power due to VSWR and applied dc bias for APG Arrestor Plus® surge arrestors with 90 volt gas tubes

Derating of maximum average power due to VSWR and applied dc bias for APG Arrestor Plus® surge arrestors with 350 volt gas tubes

Page 47: Accessories for HELIAX Products--Product Selection Guide 2007

Appendix �

Gas Tube Surge Arrestors

��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

Andrew­Arrestor­Plus®­gas­tube­surge­arrestors­allow­field­replacement­of­gas­tube­elements.­Gas­tubes­can­be­replaced­by­simply­removing­the­nut­and­replacing­the­element.­A­gas­tube­element­may­not­always­show­outward­signs­of­failure­or­degrada-tion,­therefore,­routine­maintenance­and­inspection­is­suggested.­If­the­number­of­storms­in­an­area­is­high,­gas­tube­elements­should­be­replaced­more­frequently.­Gas­tube­degradation­is­dependent­on­the­number­as­well­as­the­intensity­of­the­lightning­strikes.­As­obvious­as­it­may­seem,­gas­tube­elements­should­never­be­replaced­when­a­storm­is­occurring­or­approaching.

When­selecting­a­surge­arrestor,­the­RF­performance­must­be­considered.­Characteristics­that­describe­RF­performance­are­operating­bandwidth,­VSWR­(return­loss),­insertion­loss,­and­maximum­average­power.

Arrestor­Plus­gas­tube­arrestors­offer­the­widest­bandwidth­­available­of­any­gas­tube­surge­arrestors­on­the­market.­Unlike­quarterwave­stub­arrestors,­Andrew­APG­gas­tube­arrestors­can­be­used­for­applications­under­400­MHz.­A­single­unit­can­be­used­for­broadband­applications­over­the­full­frequency­range­of­0–2000­MHz.­Figure­5­shows­the­measured­wideband­S11­return­loss­plot­of­a­gas­tube­surge­arrestor.­Note­that­in­the­commonly­used­800–960­MHz­and­1700–2000­MHz­bands,­the­S11­levels­are­typically­better­than­-30­dB.

Over­the­operating­frequencies­of­the­Arrestor­Plus­surge­arrestor,­the­insertion­loss­is­less­than­0.1­dB,­no­more­than­adding­a­connector­to­the­transmission­line­path.­Figure­6­shows­the­measured­S21­(insertion­loss)­performance­for­a­typical­APG­family­arrestor.­Note­that­in­the­commonly­used­800–960­MHz­and­1700–2000­MHz­bands,­the­S21­levels­are­typically­-0.05­dB­and­-0.12­dB,­respectively.

Unlike­QWS­arrestors,­a­gas­tube­arrestor­can­pass­dc­current­along­the­center­conductor,­as­is­often­required­for­today’s­wireless­communication­systems­incorporating­tower­top­­active­electronics.

VSWR­and­insertion­loss­measurement­of­APG­gas­tube­surge­arrestors­can­be­made­by­using­vector­or­scalar­network­analyzers­as­well­as­a­variety­of­other­readily­available­types­of­field­test­equipment.­The­arrestors­are­dc­passing­broadband­devices­and­can­therefore­be­used­with­time­domain­reflect­meters­or­fault­location­equipment.

System­requirements­often­dictate­that­surge­arrestors­will­be­installed­outdoors.­The­Arrestor­Plus­APG­series­surge­arrestors­from­Andrew­are­ideal­for­these­applications­and­are­designed­to­withstand­the­harshest­environment.­They­are­extensively­tested­to­meet­industry­standard­specifications­for­waterproofing,­vibration,­thermal­cycling,­mechanical­shock,­salt­spray,­fungus,­and­moisture­resistance.

Andrew­Arrestor­Plus­gas­tube­surge­arrestors­are­an­excellent­choice­for­broadband­frequency­applications­or­when­a­dc­bias­is­required­for­providing­power­to­tower­top­devices.­Please­visit­our­website­at­www.andrew.com­for­more­information.­

S11 vs Frequency for an APG gas tube surge arrestor

S21 vs Frequency for an APG gas tube surge arrestor

Frequency (MHz)Figure 5

Page 48: Accessories for HELIAX Products--Product Selection Guide 2007

Appendix �

dc Passing T-Series Surge Arrestors

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

dc Passing T-Series Surge ArrestorsAndrew­Arrestor­Plus®­dc­passing­surge­arrestors­(US­patent­pending)­are­true­broadband­RF­devices­that­are­capable­of­allowing­a­dc­bias­to­pass­along­the­center­while­shorting­the­lower­frequencies­associated­with­lightning­induced­transients­to­the­outer­conductor­and­to­earth­ground.­By­removing­the­gas­tube­from­the­RF­path,­they­allow­dc­voltage­to­pass­and­greatly­enhance­power­handling­capability.

Arrestor­Plus®­dc­passing­wideband­surge­arrestors­are­the­same­general­shape­and­size­as­a­typical­quarterwave­surge­arrestors.­The­arrestor­is­comprised­of­two­coaxial­connector­interfaces­joined­by­a­center­conductor­passing­through­a­coaxial­arrestor­body.­A­shorting­stub­connects­to­the­center­conductor­on­an­axis­perpendicular­to­the­center­conductor­through­a­port­in­the­arrestor­body.­A­gas­discharge­tube­sits­directly­on­top­of­the­RF­shorting­stub,­under­constant­pressure­applied­by­the­gas­tube­spring­clip.­The­shorting­stub,­RF­shorting­stub,­gas­tube,­and­gas­tube­spring­clip­are­sealed­inside­of­the­shorting­stub­sleeve­and­arrestor­body­by­compressing­an­o-ring­between­the­screw-in­gas­cap­and­the­shorting­stub­sleeve.

The­function­of­the­various­elements­in­the­dc­passing­T-series­surge­arrestor­described­above­are­best­understood­if­modeled­as­a­simple­electronic­circuit­as­shown­in­figure­1,­below.

Figure 1 Electronic circuit diagram of

dc-passing wideband surge arrestor

The­two­coaxial­connector­interfaces,­ports­P1­and­P2,­provide­coupling­to­coaxial­cables­that­run­between­the­output­of­the­radio­equipment­and­the­surge­arrestor­and­the­surge­arrestor­and­the­antenna.­This­cable­is­indicated­as­having­a­nominal­impedance­(Zo)­of­50­Ω.­The­center­conductor­sections­that­are­between­the­coaxial­connector­interfaces­and­the­shorting­stub­are­modeled­as­transmission­lines­TL1­and­TL2.­The­shorting­stub­is­modeled­as­an­inductor­(L1)­that­connects­to­the­center­conductor­between­TL1­and­TL2.­The­outer­surface­of­the­RF­shorting­stub­is­coated­with­a­dielectric­material­to­create­a­series­capacitance­(C1)­between­the­end­of­the­helical­shorting­stub­and­the­shorting­stub­sleeve,­which­is­a­ground­(G1).­A­gas­discharge­tube­with­capacitance­(C2)­sits­in­parallel­with­capacitor­C1­and­ground­(G2).­The­inductance,­L1,­of­the­helical­shorting­stub­and­the­effec-tive­capacitance­of­parallel­capacitors­C1­and­C2­tune­the­surge­arrestor­giving­it­a­broadband­frequency­response.­

Under­normal­operating­conditions,­the­RF­signal­will­pass­straight­from­P1­to­P2­since­the­inductor,­L1,­appears­as­an­open­circuit.­When­a­dc­bias­voltage­is­applied­at­either­P1­or­P2,­it­will­also­pass­straight­through­the­device.­The­dc­bias­voltage­is­prevented­from­shorting­to­either­earth­grounds,­G1­or­G2,­by­capacitors,­C1­and­C2,­because­these­capacitors­appear­as­open­circuits­to­low­current­dc­bias­voltages­typically­applied­to­power­tower­mounted­amplifiers­or­active­antennas.­The­gas­in­the­gas­discharge­tube­will­ionize­under­lightning­strikes­or­other­high­voltage­conditions­allowing­the­transient­to­go­from­the­center­conductor­to­the­outer­conductor­or­ground­(G2).­For­purposes­of­effective­grounding,­the­surge­arrestor­can­either­be­mounted­to­ground­through­a­bulkhead­interface­or­by­mounting­the­surge­arrestor­to­a­copper­grounding­buss­bar­via­threaded­mounting­hardware­that­is­provided­with­the­surge­arrestor­or­ordered­separately.

Page 49: Accessories for HELIAX Products--Product Selection Guide 2007

Appendix �

Lightning Strike Probability

�7Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

Definitions and CommentsIsokeraunic Level:­The­isokeraunic­level­is­a­measure­of­the­number­of­thunderstorm­days­per­year.­A­thunderstorm­day­is­defined­as­a­day­on­which­thunder­is­heard.­For­example,­the­city­of­Chicago­averages­41­thunderstorm­days­per­year.­The­isoke-raunic­level­is­expressed­as:

Ty = Isokeraunic LevelsTotal Flash Density:­The­total­flash­density­is­a­measure­of­the­number­of­flashes­per­year­per­square­kilometer.­For­example,­the­city­of­Chicago­averages­33­flashes­per­year­per­square­kilometer.­Total­flash­density­includes­intracloud­flashes,­intercloud­flashes,­and­cloud-to-ground­flashes.­Total­flash­density­can­be­expressed­as­DT.­The­expression­for­total­flash­density­is­an­empirically­determined­value­based­on­many­years­of­observation­and­can­be­approximated­as­follows:

P fraction DT ≈ 0.02 x Ty2 P fraction

Ground Flash Density:­The­ground­flash­density­is­a­measure­of­the­number­of­flashes­that­reach­the­ground­(as­opposed­to­intercloud­and­intracloud­type­flashes).­Flashes­that­reach­the­ground­are­the­ones­that­are­threatening­to­us.­For­example,­the­city­of­Chicago­aver-ages­9.9­ground­flashes­per­year­per­square­kilometer.­The­expres-sion­for­ground­flash­density­is­an­empirically­determined­value­based­on­many­years­of­observation­and­can­be­expressed­as­follows:

DGround Flash = P fraction x DT

is­the­fraction­of­total­flashes­that­reach­the­ground.­The­value­is­related­to­the­latitude­as­expressed­in­the­following­equation:

P fraction = 0.1 x [1 + (latitude)2] 30

Area of Attraction of a Structure:­A­structure­has­a­defined­attrac-tion­area­that­is­strongly­dependent­on­the­height­and­less­depen-dent­on­its­width­and­length.­For­a­structure­of­height­H,­length­L,­and­width­W,­the­area­of­attraction­(sometimes­referred­to­as­“area­of­collection”)­can­be­estimated­by­using­the­following­equation.­All­units­are­in­meters.­Note­that­if­the­structure­has­a­small­length­or­small­width­as­compared­to­the­height,­such­as­a­communications­tower­or­pole,­then­the­equation­is­dominated­by­the­height.­

AreaC = L W = 4.4 H (L + W) + π (2.2 H)2

Average Number of Strikes per Year to a Tower:­The­average­number­of­strikes­per­year­for­an­arbitrary­tower­of­height­H,­length­L­and­width­W,­can­be­estimated­by­multiplying­the­Area­of­Attraction,­Area­C,­by­the­Ground­Flash­Density,­D­Ground­Flash.­Since­the­Area­of­Attraction,­is­expressed­in­square­meters­and­the­Ground­Flash­Density­is­expressed­in­square­kilometers,­a­factor­of­10-6­must­be­included.­

Sψ ≈ Areac x D Ground Flash x H 2 x 10-6

Strikes per Year, 50 foot tower:­As­an­example,­a­50-foot­tower­in­the­Chicago­area­will­average­0.040­strikes­per­year­(or­this­can­be­interpreted­as­1­strike­every­24.6­years).­The­calculations­were­based­on­a­50-foot­(15.24­meters)­height,­3.5-meter­width,­3.5-meter­length,­latitude­of­42­degrees,­and­an­isokeraunic­level­of­41­thunderstorm­days­per­year.

Strikes per Year, 100 foot tower:­As­an­example,­a­100-foot­tower­in­the­Chicago­area­will­average­0.153­strikes­per­year­(or­this­can­be­interpreted­as­1­strike­every­6.5­years).­The­calcula-tions­were­based­on­a­100-foot­(30.48­meters)­height,­3.5-meter­width,­3.5-meter­length,­latitude­of­42­degrees,­and­an­isokeraunic­level­of­41­thunderstorm­days­per­year.

Strikes per Year, 200 foot tower:­As­an­example,­a­200-foot­tower­in­the­Chicago­area­will­average­0.591­strikes­per­year­(or­this­can­be­interpreted­as­1­strike­every­1.7­years).­The­calcula-tions­were­based­on­a­200-foot­(60.96­meters)­height,­3.5-meter­width,­3.5-meter­length,­latitude­of­42­degrees,­and­an­isokeraunic­level­of­41­thunderstorm­days­per­year.

It­is­important­to­remember­that­these­are­statistical­calculations­based­on­many­years­of­observation.­When­lightning­strikes­within­even­a­few­kilometers­of­the­tower,­damaging­transients­can­be­coupled­and­carried­on­any­transmission­lines,­data­lines,­and­power­lines­in­the­vicinity­and­cause­damaging­effects­within­the­area­of­the­tower.­References1­­­IEC­1312-1,­Protection­Against­Lightning­Electromagnetic­Impulse2­­­IEEE­C62.41-1991,­IEEE­Recommended­Practice­on­Surge­Voltages­in­Low-Voltage­ac­Power­Circuits3­­­MIL-STD-188-124A,­Military­Standard­for­Grounding,­Bonding­and­Shielding4­­­MIL-HDBK-419A,­Military­Handbook­for­the­Theory­of­Grounding,­Bonding­and­Shielding­of­

Communications­Electronics.­Volume­1­(Basic­Theory),­Volume­2­(Applications)5­­­MIL-STD-1757A,­Lightning­Qualification­Test­Techniques­for­Aerospace­Vehicles­and­Hardware6­­­National­Electric­Code­1993,­Article­2807­­IEC­1024-1,­Protection­of­Structures­Against­Lightning.8­­­BS­6651,­1992­Code­of­Practice­for­Protection­of­Structures­Against­Lightning9­­­Aleksa,­J.­and­Stockman,­C.,­“A­Flash­of­Beauty­or­a­Force­for­Destruction?”,­South­African­

Wireless­Communications,­Aug­199710­­­Fisher,­F.A.­and­Plumer,­J.A.,­Lightning­Protection­of­Aircraft,­Lightning­Technologies,­1990­

Lightning Strikes—Statistics and DefinitionsStatistics on the probability of a lightning strike to towers of various heights in various locations on Earth

Isokeraunic Flash Ground Strikes per Year: Location Level Latitude Density Flash Density 50-foot tower 100-foot tower 200-foot tower

Chicago, IL 41 42 33.60 9.95 0.041 0.153 0.591Arlington, TX 48 33 46.10 9.85 0.040 0.151 0.585Atlanta, GA 50 34 50.00 11.30 0.046 0.173 0.671Tampa, FL 100 28 200.00 35.00 0.143 0.537 2.081York, UK 9 53 1.62 0.67 0.003 0.010 0.039Taiwan 20 23 8.00 1.27 0.005 0.019 0.075Hong Kong 30 23 18.00 2.85 0.012 0.043 0.170Singapore 140 2 392.00 39.30 0.160 0.604 2.340Rio de Janeiro 60 23 72.00 11.40 0.046 0.175 0.679

Page 50: Accessories for HELIAX Products--Product Selection Guide 2007

Appendix �

Additional Documents

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

Andrew Accessory Products InformationCable Hoisting and Attachment Bulletin Number

Support/Hoisting­Grips­for­HELIAX®­Cables­ 237409

Click-On­Hangers­ 237397

Standard­Hanger­Kits­­ 37378

Type­31766A­Hanger­Kits­ 17783

Hanger­Kits­ 37321

Hoisting­Grip­and­Cable­Support­Hangers­ SP30-45

Compact­Angle­Adapters­ 10140

Angle­Adaptors­(types­31768A,­243684,­243684-M)­ 237363

Hanger­Spacing­Guidelines­ TP-101619.1-EN

SnapStak™­Adapter­for­3/8"­Control­Cable­ TP-100940-EN

Cable­Tie­40417­ TP-101085-EN

Hoisting­Grip­for­1/4"­Data­Cables­ 7540680

SnapStak™­Installation­ 237637

Tools

HELIAX®­Connector­Tool­Kit­ 237274

Wrench­Kits­ 10234

Securing­Coaxial­Cable­in­a­Monopole­ 10236

Andrew­Installation­Tools­ PA-100414.2-EN

Weatherproofing

3M™­Cold­Shrink™­Weatherproofing­Kits­ 237272

3M™­Cold­Shrink™­Weatherproofing­Kits­ 237426

Application­Details­for­3M™­Cold­Shrink™­Kits­ SP50030

Connector/Splice­Weatherproofing­Kit­ 237133

WeatherShield™­Enclosures­ PA-100428.4-EN

WeatherShield™­Installation,­Main­Feeder­Antenna­ 750141

WeatherShield™­Installation,­Antenna­ 237914

Technical­Specifications­for­WeatherShield™­ TP-100257.2-EN

Cable Entry

Cabinet­Feed-Thru­Plates­for­1/2"­through­1-5/8"­­ 237362

Types­204673­and­48940­Wall/Roof­Feed­Thru­Plates­­ 237060

Single­Entrance­Wall/Roof­Feed-Thru­Kits­ 37007

ArrestorPort™­II­Entry/Ground­System­ 237516

Lightning Protection

Universal­Grounding­Bar­ 237440

Universal­Ground­Bar­Assembly­ 237513

SureGround­Installation­ 237549

Standard­Grounding­Kits­­ 237549

Connector­Grounding­Kit­ 237701

Compact­SureGround™­Kit­ PA-101089-EN

Compact­SureGround™­Testing­Performance­ SP50365-A

Compact­SureGround™­Installation­Instruction­ 7513851

The­table­below­lists­Andrew­publications­for­the­products­mentioned­in­this­guide.­­They­are­available­at­www.andrew.com.­

Page 51: Accessories for HELIAX Products--Product Selection Guide 2007

Appendix �

Hanger Spacing Guidelines

��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

Standard Hanger—Maximum Hanger SpacingCable Size Cable Type Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)

Wind Speed 85 mph (137 km/h) 100 mph (160 km/h)

Radial Ice No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)

1/2" LDF4-50A 43211A 5 (1.5) 4 (1.2) 3 (0.9) 5 (1.5) 4 (1.2) 3 (0.9)

1/2" LDF4-75A 43211A 5 (1.5) 4 (1.2) 3 (0.9) 5 (1.5) 4 (1.2) 3 (0.9)

1/2" HL4RP-50 43211A 5 (1.5) 4 (1.2) 3 (0.9) 5 (1.5) 4 (1.2) 3 (0.9)

1/2" HJ4-50 43211A 5 (1.5) 4 (1.2) 3 (0.9) 5 (1.5) 4 (1.2) 3 (0.9)

1/2" HLT4-50 43211A 5 (1.5) 4 (1.2) 3 (0.9) 5 (1.5) 3 (0.9) 2 (0.6)

1/2" HT4-50 43211A 5 (1.5) 4 (1.2) 3 (0.9) 5 (1.5) 4 (1.2) 3 (0.9)

1/2" HST4-50 43211A 5 (1.5) 3 (0.9) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

1/2" HS4RP-50 43211A 5 (1.5) 3 (0.9) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

1/2" FSJ4-50B 43211A 5 (1.5) 3 (0.9) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

1/2" FSJ4-75A 43211A 5 (1.5) 3 (0.9) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

5/8" LDF4.5-50 42396A-9 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)

5/8" HJ4.5-50 42396A-9 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)

7/8" AVA5-50 42396A-5 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)

7/8" LDF5-50A 42396A-5 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)

7/8" AL5-50 42396A-5 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)

7/8" HJ5-50 42396A-5 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)

7/8" HJ5-75 42396A-5 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)

7/8" HT5-50 42396A-5 5 (1.5) 5 (1.5) 4 (1.2) 5 (1.5) 5 (1.5) 4 (1.2)

1-1/4" LDF6-50 42396A-1 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9)

1-5/8" AVA7-50 42396A-2 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)

1-5/8" LDF7-50A 42396A-2 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)

1-5/8" AL7-50 42396A-2 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)

1-5/8" HJ7-50A 42396A-2 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)

Definitions­and­Assumptions­1.­Per­EIA-222­Standard:­Coefficient­of­drag­for­coaxial­cable­is­1.2­(cylindrical­members).­Ice­forms­completely­around­member­(360­degrees).­Combined­wind­and­ice­loading­is­reduced­by­25%­to­reflect­lower­probability­of­wind­and­ice­occurring­simultaneously.­2.­Wind­speeds­are­maximum,­which­includes­gust­factors­and­exposure­factors.­Note:­Standard­tower­configuration­spacing­is­3­to­4­ft.

HELIAX® Coaxial CableRecommended maximum hanger spacings are tabulated below for various wind speed and ice conditions. The recommendations are based on guidelines stated in EIA Standard RS-222 and new wind tunnel and vibration tests. They supersede those in previous Andrew catalogs. Please refer to Andrew publication number TP-101619-EN available at www.andrew.com for the most current recommendations.

These spacing recommendations assume that all hangers are properly installed and tightened. Installations in Typical ClimatesUse the 125 mph (200 km/h), 1/2 in ice conditions, highlighted in red. Severe or Mild ClimatesUse the wind speed and ice conditions that most closely approximate the expected worst case conditions for the local climate.

Page 52: Accessories for HELIAX Products--Product Selection Guide 2007

Appendix �

Hanger Spacing Guidelines

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�0

Standard Hanger—Maximum Hanger Spacing

Cable Size Cable Part Number Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)

Wind Speed 85 mph (137 km/h) 100 mph (160 km/h)

Radial Ice No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)

2-1/4" LDF12-50A 42395A-4 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)

2-1/4" HJ12-50 42396A-4 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9)

3" HJ8-50B 31766A-11 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)

4" HJ11-50B 31766A-10 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)

5" HJ9HP-50 33598-5 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)

5" HJ9-50 33598-5 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)

Cable Size Cable Part Number Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)

Wind Speed 125 mph (200 km/h) 150 mph (240 km/h)

Radial Ice

1/2" LDF4-50A 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)

1/2" LDF4-75A 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)

1/2" HL4RP-50 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)

1/2" HJ4-50 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)

1/2" HLT4-50 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)

1/2" HT4-50 43211A 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)

1/2" HST4-50 43211A 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)

1/2" HS4RP-50 43211A 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)

1/2" FSJ4-50B 43211A 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)

1/2" FSJ4-75A 43211A 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)

5/8" LDF4.5-50 42396A-9 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 3 (0.9)

5/8" HJ4.5-50 42396A-9 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 3 (0.9)

7/8" AVA5-50 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

7/8" LDF5-50A 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

7/8" AL5-50 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

7/8" HJ5-50 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

7/8" HJ5-75 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

7/8" HT5-50 42396A-5 5 (1.5) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

1-1/4" LDF6-50 42396A-1 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)

1-5/8" AVA7-50 42396A-2 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)

1-5/8" LDF7-50A 42396A-2 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)

1-5/8" AL7-50 42396A-2 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)

1-5/8" HJ7-50A 42396A-2 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)

2-1/4" LDF12-50 42395A-4 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)

2-1/4" HJ12-50 42396A-4 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)

3" HJ8-50B 31766A-11 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)

4" HJ11-50B 31766A-10 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)

5" HJ9HP-50 33598-5 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)

5" HJ9-50 33598-5 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)

No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)

Note:­Standard­tower­configuration­spacing­is­3­to­4­ft.­

Page 53: Accessories for HELIAX Products--Product Selection Guide 2007

Appendix �

Hanger Spacing Guidelines

��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

Snap-In Hanger—Recommended Maximum Hanger Spacing

Cable Size Cable Part Number Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)

Wind Speed 85 mph (137 km/h) 100 mph (160 km/h)

Radial Ice No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)

1/2" LDF4-50A SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

1/2" LDF4-75A SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

1/2" HL4RP-50 SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

1/2" HJ4-50 SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

1/2" HLT4-50 SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

1/2" HT4-50 SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

1/2" HST4-50 SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

1/2" HS4RP-50 SSH-12 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

1/2" FSJ4-50B SSH-12 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 2 (0.6)

1/2" FSJ4-75A SSH-12 4 (1.2) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 2 (0.6)

5/8" LDF4.5-50 206706A-6 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

5/8" HJ4.5-50 206706A-6 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 2 (0.6)

7/8" AVA5-50 SSH-78 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)

7/8" LDF5-50A SSH-78 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)

7/8" AL5-50 SSH-78 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)

7/8" HJ5-50 SSH-78 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)

7/8" HJ5-75 SSH-78 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)

7/8" HT5-50 SSH-78 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)

1-1/4" LDF6-50 SSH-114 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)

1-5/8" AVA7-50 SSH-158 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)

1-5/8" LDF7-50A SSH-158 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)

1-5/8" AL7-50 SSH-158 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)

1-5/8" HJ7-50A SSH-158 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6)

2-1/4" LDF12-50 206706A-6 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6)

2-1/4" HJ12-50 206706A-6 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6)

Definitions­and­Assumptions­1.­Per­EIA-222­Standard:­Coefficient­of­drag­for­coaxial­cable­is­1.2­(cylindrical­members).­Ice­forms­completely­around­member­(360­degrees).­Combined­wind­and­ice­loading­is­reduced­by­25%­to­reflect­lower­probability­of­wind­and­ice­occurring­simultaneously.­2.­Wind­speeds­are­maximum,­which­includes­gust­factors­and­exposure­factors.­Note:­Standard­tower­configuration­spacing­is­3­to­4­ft.

Page 54: Accessories for HELIAX Products--Product Selection Guide 2007

Appendix �

Hanger Spacing Guidelines

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

Snap-In Hanger—Recommended Maximum Hanger Spacing

Cable Size Cable Part Number Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)

Wind Speed 125 mph (200 km/h) 150 mph (240 km/h)

Radial Ice

1/2" LDF4-50A SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)

1/2" LDF4-75A SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)

1/2" HL4RP-50 SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)

1/2" HJ4-50 SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)

1/2" HLT4-50 SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)

1/2" HT4-50 SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)

1/2" HST4-50 SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)

1/2" HS4RP-50 SSH-12 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 1 (0.3)

1/2" FSJ4-50B SSH-12 3 (0.9) 2 (0.6) 1 (0.3) 2 (0.6) 2 (0.6) 1 (0.3)

1/2" FSJ4-75A SSH-12 3 (0.9) 2 (0.6) 1 (0.3) 2 (0.6) 2 (0.6) 1 (0.3)

5/8" LDF4.5-50 206706A-6 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6) 1 (0.3)

5/8" HJ4.5-50 206706A-6 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6) 1 (0.3)

7/8" AVA5-50 SSH-78 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)

7/8" LDF5-50A SSH-78 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)

7/8" AL5-50 SSH-78 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)

7/8" HJ5-50 SSH-78 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)

7/8" HJ5-75 SSH-78 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)

7/8" HT5-50 SSH-78 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)

1-1/4" LDF6-50 SSH-114 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)

1-5/8" AVA7-50 SSH-158 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)

1-5/8" LDF7-50A SSH-158 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)

1-5/8" AL7-50 SSH-158 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)

1-5/8" HJ7-50A SSH-158 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)

2-1/4" LDF12-50 206706A-6 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 1 (0.3) 1 (0.3)

2-1/4" HJ12-50 206706A-6 2 (0.6) 2 (0.6) 1 (0.3) 2 (0.6) 1 (0.3) 1 (0.3)

No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)

Definitions­and­Assumptions­1.­Per­EIA-222­Standard:­Coefficient­of­drag­for­coaxial­cable­is­1.2­(cylindrical­members).­Ice­forms­completely­around­member­(360­degrees).­Combined­wind­and­ice­loading­is­reduced­by­25%­to­reflect­lower­probability­of­wind­and­ice­occurring­simultaneously.­2.­Wind­speeds­are­maximum,­which­includes­gust­factors­and­exposure­factors.­Note:­Standard­tower­configuration­spacing­is­3­to­4­ft.

Page 55: Accessories for HELIAX Products--Product Selection Guide 2007

Appendix �

Hanger Spacing Guidelines

��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

Click-On Hanger—Recommended Maximum Hanger Spacing

Cable Size Cable Part Number Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)

Wind Speed 85 mph (137 km/h) 100 mph (160 km/h)

Radial Ice

1/2" LDF4-50A L4CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)

1/2" LDF4-50A L4CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)

1/2" LDF4-50A L4CLICK, 3 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)

No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)

Note:­These­same­hanger­spacing­recommendations­apply­for­the­other­following­1/2­in­cable­types:­LDF4-75A,­HL4RP-50,­HLT4-50,­HS4RP-50,­HST4-50,­HT4-50,­HJ4-50

5/8" LDF4.5-50A L45CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)

5/8" LDF4.5-50A L45CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)

5/8" LDF4.5-50A L45CLICK, 3 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)

Note:­These­same­hanger­spacing­recommendations­apply­for­the­other­following­5/8­in­cable­types:­HJ4.5-50

7/8" LDF5-50A L5CLICK, 1 Stack 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9)

7/8" LDF5-50A L5CLICK, 2 Stack 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9)

7/8" LDF5-50A L5CLICK, 3 Stack 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9)

Note:­These­same­hanger­spacing­recommendations­apply­for­the­other­following­7/8­in­cable­types:­AVA5-50,­VXL5-50,­AL5-50,­HJ5-50,­HJ5-75,­HT5-5

1-1/4" LDF6-50 L6CLICK, 1 Stack 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9)

1-1/4" LDF6-50 L6CLICK, 2 Stack 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9)

1-1/4" LDF6-50 L6CLICK, 3 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)

1-5/8" LDF7-50A L7CLICK, 1 Stack 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9)

1-5/8" LDF7-50A L7CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)

1-5/8" LDF7-50A L7CLICK, 3 Stack 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)

Note:­These­same­hanger­spacing­recommendations­apply­for­the­other­following­1­5/8­in­cable­types:­HJ7-50A,­AVA7-50,­AL7-50

*­These­hanger­spacings­have­been­specified­based­on­using­the­Click-On­Hangers­with­Andrew­specified­hardware­kits.

(Note:­Standard­tower­configuration­spacing­is­3­to­4­ft)

Definitions­and­Assumptions­1.­Per­EIA-222­Standard:­Coefficient­of­drag­for­coaxial­cable­is­1.2­(cylindrical­members).­Ice­forms­completely­around­member­(360­degrees).­Combined­wind­and­ice­loading­is­reduced­by­25%­to­reflect­lower­probability­of­wind­and­ice­occurring­simultaneously.­2.­Wind­speeds­are­maximum,­which­includes­gust­factors­and­exposure­factors.

Page 56: Accessories for HELIAX Products--Product Selection Guide 2007

Appendix �

Hanger Spacing Guidelines

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

Click-On Hanger—Recommended Maximum Hanger Spacing

Cable Size Cable Part Number Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)

Wind Speed 125 mph (200 km/h) 150 mph (240 km/h)

Radial Ice

1/2" LDF4-50A L4CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)

1/2" LDF4-50A L4CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)

1/2" LDF4-50A L4CLICK, 3 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6

No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)

Note:­These­hanger­spacing­recommendations­are­also­applicable­for­these­1/2­in­cable­types:­LDF4-75A,­HL4RP-50,­HLT4-50,­HS4RP-50,­HST4-50,­HT4-50,­HJ4-50

5/8" LDF4.5-50A L45CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)

5/8" LDF4.5-50A L45CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)

5/8" LDF4.5-50A L45CLICK, 3 Stack 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6)

Note:­These­hanger­spacing­recommendations­are­also­applicable­for­this­5/8­in­cable­type:­HJ4.5-50

7/8" LDF5-50A L5CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)

7/8" LDF5-50A L5CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)

7/8" LDF5-50A L5CLICK, 3 Stack 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6)

Note:­These­hanger­spacing­recommendations­are­also­applicable­for­these­7/8­in­cable­types:­AVA5-50,­VXL5-50,­AL5-50,­HJ5-50,­HJ5-75,­HT5-5

1-1/4" LDF6-50 L6CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)

1-1/4" LDF6-50 L6CLICK, 2 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)

1-1/4"

1-5/8" LDF7-50A L7CLICK, 1 Stack 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6)

1-5/8" LDF7-50A L7CLICK, 2 Stack 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6)

1-5/8" LDF7–50A L7CLICK, 3 Stack 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6)

LDF6-50 L6CLICK, 3 Stack 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6)

Note:­These­hanger­spacing­recommendations­are­also­applicable­for­these­1­5/8­in­cable­types:­HJ7-50A,­AVA7-50,­AL7-50

(Note:­Standard­tower­configuration­spacing­is­3­to­4­ft)

Mini Click-On Hanger—Recommended Maximum Hanger Spacing

Cable Size Cable Part Number Hanger Part Number

Wind Speed 125 mph (200 km/h)

Radial Ice

6 mm–8mm CNT-240, CNT-300, FSJ1 series 68MCLICK, 1 Stack 1.5 (0.61) 1.5 (0.61) 1.5 (0.61)

6 mm–8mm CNT-240, CNT-300, FSJ1 series 68MCLICK, 2 Stack 1.5 (0.61) 1.5 (0.61) 1.5 (0.61)

6 mm–8mm

9 mm–12 mm CNT-400, LDF1, FSJ2, LDF2, EFX2 series 912MCLICK, 1 Stack 3.0 (0.90) 3.0 (0.90) 3.0 (0.90)

9 mm–12 mm CNT-400, LDF1, FSJ2, LDF2, EFX2 series 912MCLICK, 2 Stack 3.0 (0.90) 3.0 (0.90) 3.0 (0.90)

9 mm–12 mm

13 mm–16 mm CNT-500, CNT-600, FSJ and LDF4 series 1316MCLICK, 1 Stack 3.0 (0.90) 3.0 (0.90) 3.0 (0.90)

13 mm–16 mm CNT-500, CNT-600, FSJ and LDF4 series 1316MCLICK, 2 Stack 3.0 (0.90) 3.0 (0.90) 3.0 (0.90)

13 mm–16 mm CNT-500, CNT-600, FSJ and LDF4 series 1316MCLICK, 3 Stack 2.0 (0.60) 2.0 (0.60) 2.0 (0.60)

CNT-400, LDF1, FSJ2, LDF2, EFX2 series 912MCLICK, 3 Stack 2.0 (0.60) 2.0 (0.60) 2.0 (0.60)

CNT-240, CNT-300, FSJ1 series 68MCLICK, 3 Stack 1.5 (0.61) 1.5 (0.61) 1.5 (0.61)

No Ice 1/2" (13 mm) 1" (25 mm)

Definitions­and­Assumptions­1.­Per­EIA-222­Standard:­Coefficient­of­drag­for­coaxial­cable­is­1.2­(cylindrical­members).­Ice­forms­completely­around­member­(360­degrees).­Combined­wind­and­ice­loading­is­reduced­by­25%­to­reflect­lower­probability­of­wind­and­ice­occurring­simultaneously.­2.­Wind­speeds­are­maximum,­which­includes­gust­factors­and­exposure­factors.­Note:­Standard­tower­configuration­spacing­is­3­to­4­ft.

Page 57: Accessories for HELIAX Products--Product Selection Guide 2007

Appendix �

Hanger Spacing Guidelines

��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

Standard Hanger for HELIAX® Elliptical Waveguide—Recommended Maximum Hanger Spacing

Waveguide Type Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)

Wind Speed 85 mph (137 km/h) 100 mph (160 km/h)

Radial Ice No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)

EW17 31766A-9 6.0 (1.80) 6.0 (1.80) 6.0 (1.80) 6.0 (1.80) 6.0 (1.80) 6.0 (1.80)

EW20 31766A-10 6.0 (1.80) 6.0 (1.80) 6.0 (1.80) 6.0 (1.80) 6.0 (1.80) 6.0 (1.80)

EW28 31766A-11 6.0 (1.80) 6.0 (1.80) 6.0 (1.80) 6.0 (1.80) 6.0 (1.80) 5.5 (1.68)

EW37 42396A-4 6.0 (1.80) 6.0 (1.80) 5.5 (1.68) 5.5 (1.68) 5.5 (1.68) 5.0 (1.50)

EW43 42396A-16 6.0 (1.80) 6.0 (1.80) 5.5 (1.68) 5.0 (1.50) 5.0 (1.50) 4.5 (1.37)

EW52 42396A-8 5.5 (1.68) 5.0 (1.50) 4.5 (1.37) 4.5 (1.37) 4.5 (1.37) 4.0 (1.20)

EW63 42396A-7 5.0 (1.50) 4.5 (1.37) 4.0 (1.20) 4.0 (1.20) 4.0 (1.20) 3.5 (1.07)

EW64 42396A-1 5.0 (1.50) 6.0 (1.80) 4.0 (1.20) 4.5 (1.37) 4.0 (1.20) 3.5 (1.07)

EW77 42396A-11 5.0 (1.50) 6.0 (1.80) 4.0 (1.20) 4.5 (1.37) 4.0 (1.20) 3.5 (1.07)

EW85 42396A-5 5.5 (1.68) 6.0 (1.80) 4.0 (1.20) 4.5 (1.37) 4.0 (1.20) 3.5 (1.07)

EW90 42396A-5 5.5 (1.68) 4.5 (1.37) 4.0 (1.20) 4.5 (1.37) 4.0 (1.20) 3.0 (0.90)

EW127A 42396A-9 5.5 (1.68) 4.5 (1.37) 3.5 (1.07) 4.5 (1.37) 4.0 (1.20) 3.0 (0.90)

EW132 42396A-9 5.5 (1.68) 4.5 (1.37) 3.5 (1.07) 5.0 (1.20) 4.0 (1.20) 3.0 (0.90)

EW180 43211A 6.0 (1.80) 4.5 (1.37) 3.5 (1.07) 5.0 (1.20) 4.0 (1.20) 3.0 (0.90)

EW220 43211A 6.0 (1.80) 4.5 (1.37) 3.5 (1.07) 5.0 (1.20) 4.0 (1.20) 3.0 (0.90)

EW240 43211A 6.0 (1.80) 4.5 (1.37) 3.5 (1.07) 5.0 (1.20) 4.0 (1.20) 3.0 (0.90)

EW380 43211A 6.0 (1.80) 4.5 (1.37) 3.5 (1.07) 5.0 (1.20) 4.0 (1.20) 3.0 (0.90)

Note:­Standard­tower­configuration­spacing­is­3­to­4­ft.

HELIAX® Elliptical WaveguideRecommended maximum hanger spacings are tabulated below for various wind speed and ice conditions. The recommendations are based on guidelines stated in EIA Standard RS-222 and new wind tunnel and vibration tests. They supersede those in previous Andrew catalogs.

Installations in Typical ClimatesUse the 125 mph (200 km/h), 1/2 in ice conditions, highlighted in red. Severe or Mild ClimatesUse the wind speed and ice conditions that most closely approximate the expected worst case conditions for the local climate.

Page 58: Accessories for HELIAX Products--Product Selection Guide 2007

Appendix �

Hanger Spacing Guidelines

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

Standard Hanger for HELIAX® Elliptical Waveguide—Recommended Maximum Hanger Spacing

Waveguide Type Hanger Part Number Recommended Maximum Hanger Spacing, feet (meters)

Wind Speed 125 mph (200 km/h) 150 mph (240 km/h)

Radial Ice

EW17 31766A-9 6.0 (1.80) 6.0 (1.80) 5.5 (1.68) 5.0 (1.50) 5.0 (1.50) 4.5 (1.37)

EW20 31766A-10 5.5 (1.68) 5.5 (1.68) 5.0 (1.50) 4.5 (1.37) 4.5 (1.37) 4.0 (1.20)

EW28 31766A-11 5.0 (1.50) 5.0 (1.50) 4.5 (1.37) 4.0 (1.20) 4.0 (1.20) 3.5 (1.07)

EW37 42396A-4 4.5 (1.37) 4.5 (1.37) 4.0 (1.20) 3.5 (1.07) 3.5 (1.07) 3.0 (.090)

EW43 42396A-16 4.0 (1.20) 4.0 (1.20) 3.5 (1.07) 3.5 (1.07) 3.5 (1.07) 3.0 (.090)

EW52 42396A-8 3.5 (1.07) 3.5 (1.07) 3.0 (.090) 3.0 (.090) 3.0 (.090) 2.5 (0.76)

EW63 42396A-7 3.5 (1.07) 3.0 (.090) 2.5 (0.76) 2.5 (0.76) 2.5 (0.76) 2.0 (0.60)

EW64 42396A-1 3.5 (1.07) 3.0 (.090) 2.5 (0.76) 3.0 (.090) 2.5 (0.76) 2.0 (0.60)

EW77 42396A-11 3.5 (1.07) 3.0 (.090) 2.5 (0.76) 3.0 (.090) 2.5 (0.76) 2.0 (0.60)

EW85 42396A-5 3.5 (1.07) 3.0 (.090) 2.5 (0.76) 3.0 (.090) 2.5 (0.76) 2.0 (0.60)

EW90 42396A-5 3.5 (1.07) 3.0 (.090) 2.5 (0.76) 3.0 (.090) 2.5 (0.76) 2.0 (0.60)

EW127A 42396A-9 3.5 (1.07) 3.0 (.090) 2.5 (0.76) 3.0 (.090) 2.5 (0.76) 2.0 (0.60)

EW132 42396A-9 4.0 (1.20) 3.0 (.090) 2.5 (0.76) 3.0 (.090) 2.5 (0.76) 2.0 (0.60)

EW180 43211A 4.0 (1.20) 3.0 (.090) 2.5 (0.76) 3.5 (1.07) 2.5 (0.76) 2.0 (0.60)

EW220 43211A 4.0 (1.20) 3.0 (.090) 2.5 (0.76) 3.5 (1.07) 2.5 (0.76) 2.0 (0.60)

EW240 43211A 4.0 (1.20) 3.0 (.090) 2.5 (0.76) 3.5 (1.07) 2.5 (0.76) 2.0 (0.60)

No Ice 1/2" (13 mm) 1" (25 mm) No Ice 1/2" (13 mm) 1" (25 mm)

Definitions­and­Assumptions­1.­Per­EIA-222­Standard:­Coefficient­of­drag­for­coaxial­cable­is­1.2­(cylindrical­members).­Ice­forms­completely­around­member­(360­degrees).­Combined­wind­and­ice­loading­is­reduced­by­25%­to­reflect­lower­probability­of­wind­and­ice­occurring­simultaneously.­2.­Wind­speeds­are­maximum,­which­includes­gust­factors­and­exposure­factors.­Note:­Standard­tower­configuration­spacing­is­3­to­4­ft.

*­These­hanger­spacing­recommendations­have­been­specified­using­the­click-on­hangers­with­Andrew­specified­hardware­kits.

Page 59: Accessories for HELIAX Products--Product Selection Guide 2007

IND

EX

Page 60: Accessories for HELIAX Products--Product Selection Guide 2007

114468.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 28114469.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 2812395-1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111316MCLICK­. . . . . . . . . . . . . . . . . . . . . . . . . . . 1319256B ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8204673-1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-10­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-12­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-16­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-18­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-20­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-24­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-2A­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-6­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-8­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204673-9­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-13­. . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-14­. . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-15­. . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-16­. . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-17­. . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-18­. . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-19­. . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-3­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-5­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-6­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-7­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-8­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204679A-9­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22204989­­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32204989-10­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33204989-28­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33204989-6­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33206706A-5­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9206706A-6­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9207270.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 32207270.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 32209874.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 25209874.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 25220497.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 33220498.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 33221213.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 21221213.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 21221213-S­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21223158-2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33223158-3­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33223158-4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33223700-724­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33224352.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 28224354.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 28224355.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 28224356.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 28224360.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 28224361.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 27224361.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 27224361.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 27224362.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 27

224362.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 27224362.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 27224363.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 28224368.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 28224373.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 28224380.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 28224395.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 28241088.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 32241088-1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-10­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-3­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-5­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-6­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-60­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-64­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-7­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-8­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241088-9­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33241475-13­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 20241545.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 33241953.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 27243095-1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-10­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-11­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-12­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-3­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-5­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-6­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-7­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-8­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13243095-9­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1324312A ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8243684.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 12243684.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 16243684-M ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 16243684-MH ­. . . . . . . . . . . . . . . . . . . . . . . . . . . 15243950.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 38243951.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 38244350.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 12244373.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 26244374.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 26244374.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 26244374.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 28244375.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 26244375.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 28244376.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 26244377.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 26244377.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 28244378.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 26244378.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 27244379.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 26244379.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 28244394.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 27244459-5­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27244459-6­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28244459-7­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28244494.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 27244494.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 27

244495.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 32244847.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 38245154.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 26245154.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 27245171.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 20245172.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 20245173.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 20245174.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­ ­20245175.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 20245314-127A­. . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-132­. . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-180­. . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-220­. . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-240­. . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-37­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-43­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-52­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-63­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-64­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-77­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-85­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23245314-90­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23245516.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 27245529-10­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 32247696.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 26247696.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 26247696.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 27247698.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 26247698.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 28247763.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 16247763-I ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16252026-10KT­. . . . . . . . . . . . . . . . . . . . . . . . . . 13252027-10KT­. . . . . . . . . . . . . . . . . . . . . . . . . . 13252028-10KT­. . . . . . . . . . . . . . . . . . . . . . . . . . 13252029-10KT­. . . . . . . . . . . . . . . . . . . . . . . . . . 1326985A ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 829958.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 829961.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 830848-1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1730848-2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1730848-3­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1730848-4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1730848-5­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1731031-1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 831535.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 831670-1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1631670-2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1631670-3­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1631670-4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1631670-5­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1631670-6­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1631766A-10­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531766A-10­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531766A-11­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531766A-11­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531766A-9­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531768A-M ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1631769-1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531769-5­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531771.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 1531771-10­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531771-4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Index

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com��

Page 61: Accessories for HELIAX Products--Product Selection Guide 2007

31771-6­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1531771-9­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1534759.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 835849A-10­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2335849A-13­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2335849A-9­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233CCGRIP­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 840417.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 1742334.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 1742396A-1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-11­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-16­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-5­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-5­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-5­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-7­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-8­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-9­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-9­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542396A-9­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542615-10­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2143094.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 843211A ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1543211A ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1543211A ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1543211A ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1543211A ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1548939A-1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-10­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-14­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-15­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-16­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-17­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-3­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-5­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-6­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-7­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-8­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2248939A-9­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2268MCLICK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13912MCLICK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 139905-41­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219905-71­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21A5MCPT-78 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . 25A5MCPT-BK5 ­. . . . . . . . . . . . . . . . . . . . . . . . . . 25ABT-DFDM-ADBH ­. . . . . . . . . . . . . . . . . . . . . . . 38ABT-DFDM-DB­. . . . . . . . . . . . . . . . . . . . . . . . . . 38ABT-DMDF-ADBH ­. . . . . . . . . . . . . . . . . . . . . . . 38ABT-DMDF-DB­. . . . . . . . . . . . . . . . . . . . . . . . . . 38ABT-NFNM-DB­. . . . . . . . . . . . . . . . . . . . . . . . . . 38ABT-NMNF-DB­. . . . . . . . . . . . . . . . . . . . . . . . . . 38ADCB-DFDM-DB­. . . . . . . . . . . . . . . . . . . . . . . . 38APB-BNFNF-2400­. . . . . . . . . . . . . . . . . . . . . . . 37APC-BDFDM-450 ­. . . . . . . . . . . . . . . . . . . . . . . 37APC-BDFDM-700 ­. . . . . . . . . . . . . . . . . . . . . . . 37APC-BDFDM-DB ­. . . . . . . . . . . . . . . . . . . . . . . . 37

APG-BDFDF-090­. . . . . . . . . . . . . . . . . . . . . . . . 37APG-BDFDF-350­. . . . . . . . . . . . . . . . . . . . . . . . 37APG-BDFDM-090 ­. . . . . . . . . . . . . . . . . . . . . . . 37APG-BDFDM-350 ­. . . . . . . . . . . . . . . . . . . . . . . 37APG-BNFNF-090­. . . . . . . . . . . . . . . . . . . . . . . . 37APG-BNFNF-350­. . . . . . . . . . . . . . . . . . . . . . . . 37APG-BNFNM-090 ­. . . . . . . . . . . . . . . . . . . . . . . 37APG-BNFNM-350 ­. . . . . . . . . . . . . . . . . . . . . . . 37APORT-13-4­. . . . . . . . . . . . . . . . . . . . . . . . . . . 22APTA5DC-BDF-DB­. . . . . . . . . . . . . . . . . . . . . . . 38APTA7DC-BDF-DB­. . . . . . . . . . . . . . . . . . . . . . . 38APT-BDFDF-DB­. . . . . . . . . . . . . . . . . . . . . . . . . 37APT-BDFDM-DB­. . . . . . . . . . . . . . . . . . . . . . . . . 37APT-BNFNF-DB­. . . . . . . . . . . . . . . . . . . . . . . . . 37APT-BNFNM-DB­. . . . . . . . . . . . . . . . . . . . . . . . . 37APTDC-BDFDF-DB­. . . . . . . . . . . . . . . . . . . . . . . 37APTDC-BDFDM-DB­. . . . . . . . . . . . . . . . . . . . . . 37APTDC-BNFNM-DB­. . . . . . . . . . . . . . . . . . . . . . 37APT-DFDF-DB­. . . . . . . . . . . . . . . . . . . . . . . . . . 37APT-DFDM-DB­. . . . . . . . . . . . . . . . . . . . . . . . . . 37APT-NFNF-DB­. . . . . . . . . . . . . . . . . . . . . . . . . . 37APT-NFNM-DB­. . . . . . . . . . . . . . . . . . . . . . . . . . 37ARA-22­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11AWE-11412 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . 19AWE-15812 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . 19AWE-7812 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 19AWE-A12 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19C2SGRIP­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8C2SGRIP-2IK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8CAP-4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22CGT114 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32CGT12 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32CGT158 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32CGT214 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32CGT58 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32CGT78 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32CM-TB ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21CM-TBR ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21CM-TG ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21CM-TR ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21CM-TW­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21CM-TY ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21CPT-158U­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-158U­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-158U­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28CPT-78U­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-78U­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-78U­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27CPT-BK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-BK5­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-BK6­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-BK7­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-BKS1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-BKS1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-BKS1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-BKS1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-BKS1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-E2L2DIN.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 24CPT-E2L2DIN.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 24CPT-E2L2DIN.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 24CPT-E2L2N­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-E2L2N­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

CPT-E2L2N­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-F4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-F4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-F4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27CPT-L1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-L1­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-L45RC­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-L45RC­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-L4ARC1­. . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-L4ARC1­. . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPT-L4ARC1­. . . . . . . . . . . . . . . . . . . . . . . . . . . 27CPTL6­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPTL6­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPTL6­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28CPTV2-114­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPTV2-114­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 28CPTV2-158­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPTV2-158­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 28CPTV2-BK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24CPTV2-BK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28CPTV2-BK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28CS-B­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11CSGL4-06B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL4-06S2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL4-10B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL4-10S2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL4-15B4­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL4-15S4­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL5-06B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL5-06S2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL5-10B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL5-10S2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL5-15B4­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL5-15S4­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL6-06B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL6-06S2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL6-10B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL6-10S2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL6-15B4­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL6-15S4­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL7-06B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL7-06S2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL7-10B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL7-10S2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL7-15B4­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33CSGL7-15S4­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33DF-CAPKIT ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 38E2SGRIP­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8E2SGRIP-2IK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8EP-CAP5­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22EWSH-127A ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 9EWSH-132 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9EWSH-180 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9EWSH-220 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9EWSH-240 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9EWSH-52 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9EWSH-63 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9EWSH-64 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9EWSH-77 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9EWSH-90 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9F1SGRIP­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8F1SGRIP-1IK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Index

��Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com

Page 62: Accessories for HELIAX Products--Product Selection Guide 2007

F2SGRIP­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8F2SGRIP-2IK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8F4SGRIP­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8F4SGRIP-4IK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8GASTUBE-090­. . . . . . . . . . . . . . . . . . . . . . . . . . 38GBKIT-0414 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . 35GK-SUNV­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33GKT-114A­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-114A­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-114A­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28GKT-158A­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-158A­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-158A­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28GKT-78A­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-78A­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-78A­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27GKT-BK512­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-BK512­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-BK512­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 27GKT-BK512­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 27GKT-BK67­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-BK67­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-BK67­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28GKT-BK67­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28GKT-BKF4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-F4A­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-F4A­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-L4A­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-L4A­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26GKT-L4A­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27L12SGRIP­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L12SGRIP-12IK­. . . . . . . . . . . . . . . . . . . . . . . . . . 8L12SGRIP-12IK­. . . . . . . . . . . . . . . . . . . . . . . . . . 8L1SGRIP­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L1SGRIP-1IK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L2SGRIP­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L2SGRIP-2IK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L45CLAMP-(­)­. . . . . . . . . . . . . . . . . . . . . . . . . . 14L45CLICK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12L45SGRIP­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L45SGRIP-45IK­. . . . . . . . . . . . . . . . . . . . . . . . . . 8L45SGRIP-45IK­. . . . . . . . . . . . . . . . . . . . . . . . . . 8L4CLAMP-(­)­. . . . . . . . . . . . . . . . . . . . . . . . . . . 14L4CLICK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12L4SCLICK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12L4SGRIP­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L4SGRIP-4IK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L4SGRIP-4IK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L5CLAMP-(­)­. . . . . . . . . . . . . . . . . . . . . . . . . . . 14L5CLICKB­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12L5SCLICKB­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 12L5SGRIP­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L5SGRIP-5IK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L5SGRIP-5IK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L6CLAMP-(­)­. . . . . . . . . . . . . . . . . . . . . . . . . . . 14L6CLICK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12L6SCLICK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12L6SGRIP­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L6SGRIP-6IK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L6SGRIP-6IK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L7CLAMP-(­)­. . . . . . . . . . . . . . . . . . . . . . . . . . . 14L7CLICK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

L7SCLICK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12L7SGRIP­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L7SGRIP-7IK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8L7SGRIP-7IK­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8MCPT-1412.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 25MCPT-1412.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 27MCPT-1412.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 27MCPT-3812.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 25MCPT-3812.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 27MCPT-78.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 25MCPT-78.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 27MCPT-BK4 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 25MCPT-BK5 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 25MCPT-L4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25MCPT-L4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27MCPT-V2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25MF39901-10.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 17MT-F1598­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11MT-F1599­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11MT-F1600­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11PLUG-114­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22PLUG-12­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22PLUG-158­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22PLUG-78­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22R8CLAMP-(­)­. . . . . . . . . . . . . . . . . . . . . . . . . . . 14RM-USBG­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11SA-38­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12SCE-114­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22SCE-12­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22SCE-158­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22SCE-214­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22SCE-58­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22SCE-78­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22SG-IT ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8SGL12-06B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL12-10B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL12-15B4­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL4-06B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL4-06S2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL4-10B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL4-15B4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL45-06B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL45-10B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL45-15B4­. . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL5-06B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL5-06B2-T­. . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL5-06S2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL5-10B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL5-15B4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL5-15B4-T­. . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL6-06B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL6-06S2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL6-10B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL6-15B4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL7-06B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL7-06B2-T­. . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL7-06S2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL7-10B2­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL7-15B4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33SGL7-15B4-T­. . . . . . . . . . . . . . . . . . . . . . . . . . 33SHT-4­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10SSH-114­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

SSH-12­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9SSH-158­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9SSH-78­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9SSHA-38­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9SSHAK-3812­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 9SS-TB2550­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 11SS-TB6080­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 11STS3-12­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10STS3-23­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10STS3-34­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10STS3-45­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10TB-COMP-KIT­. . . . . . . . . . . . . . . . . . . . . . . . . . 27UA-3­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10UAAI­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10UG12158-15B4­. . . . . . . . . . . . . . . . . . . . . . . . . 33UGBA-34­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36UGBA-36­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36UGBA-DIN-34 ­. . . . . . . . . . . . . . . . . . . . . . . . . . 36UGBA-DIN-36 ­. . . . . . . . . . . . . . . . . . . . . . . . . . 36UGBKIT­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34UGBKIT-0210 ­. . . . . . . . . . . . . . . . . . . . . . . . . . 34UGBKIT-0210-T­. . . . . . . . . . . . . . . . . . . . . . . . . 34UGBKIT-0212 ­. . . . . . . . . . . . . . . . . . . . . . . . . . 34UGBKIT-0212-T­. . . . . . . . . . . . . . . . . . . . . . . . . 34UGBKIT-0214 ­. . . . . . . . . . . . . . . . . . . . . . . . . . 34UGBKIT-0214-T­. . . . . . . . . . . . . . . . . . . . . . . . . 34UGBKIT-0412 ­. . . . . . . . . . . . . . . . . . . . . . . . . . 35UGBKIT-0412-T­. . . . . . . . . . . . . . . . . . . . . . . . . 35UGBKIT-0414-T­. . . . . . . . . . . . . . . . . . . . . . . . . 35UGBKIT-0420 ­. . . . . . . . . . . . . . . . . . . . . . . . . . 36UGBKIT-0420-T­. . . . . . . . . . . . . . . . . . . . . . . . . 36UGBKIT-0424 ­. . . . . . . . . . . . . . . . . . . . . . . . . . 36UGBKIT-0424-T­. . . . . . . . . . . . . . . . . . . . . . . . . 36UGBKIT-2 ­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34UGBKIT-2T.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 34UGBKIT-T.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­.­. 35WGB4-127­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-132­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-180­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-220­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-240­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-37­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-43­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-52­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-63­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-64­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-77­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-85­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB4-90­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-122­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-132­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-180­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-220­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-240­. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-37­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-43­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-52­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-63­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-64­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-77­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-85­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23WGB5-90­. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Index

Andrew Corporation phone 1.800.255.1479 • 1.708.873.2307 fax 1.800.349.5444 • 1.779.435.8579 www.andrew.com�0

Page 63: Accessories for HELIAX Products--Product Selection Guide 2007
Page 64: Accessories for HELIAX Products--Product Selection Guide 2007

Andrew Corporation3 Westbrook Corporate CenterSuite 900Westchester, IL 60154

Customer Support CenterFrom North AmericaTelephone: 1-800-255-1479Fax: 1-800-349-5444

InternationalTelephone: +1-708-873-2307Fax: +1-708-349-5444Internet: www.andrew.com

All designs, specifications, and availabilities of products and services presented in this catalog are subject to change without notice.