Advisor : Cheng-Hsin Chuang Advisee ﹕Tsan-Hsiu Li Department of Mechanical Engineering Southern Taiwan University Date ﹕2013/9/13 Paper Survey Design of Noncontact Tumor Imager for Video-Assisted Thoracic Surgery IEEE/ASME TRANSACTIONS ON MECHATRONICS, VOL. 15, NO. 6, DECEMBER 2010 Tomohiro Kawahara, Member, Yoshihiro Miyata, Koichi Akayama, Masazumi Okajima, Makoto Kaneko Graduate School of Biomedical Sciences, Hiroshima University Hospital, Hiroshima University, Hiroshima , Japan

Upload: frank-mosley

Post on 20-Jan-2016

213 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Advisor : Cheng-Hsin Chuang Advisee ﹕ Tsan-Hsiu Li Department of Mechanical Engineering Southern Taiwan University Date ﹕ 2013/9/13 Paper Survey Design

Advisor : Cheng-Hsin Chuang Advisee Tsan-Hsiu Li﹕

Department of Mechanical EngineeringSouthern Taiwan University

Date 2013/9/13﹕

Paper Survey

Design of Noncontact Tumor Imager forVideo-Assisted Thoracic Surgery

IEEE/ASME TRANSACTIONS ON MECHATRONICS, VOL. 15, NO. 6, DECEMBER 2010

Tomohiro Kawahara, Member, Yoshihiro Miyata, Koichi Akayama, Masazumi Okajima, Makoto Kaneko

Graduate School of Biomedical Sciences, Hiroshima University Hospital, Hiroshima University, Hiroshima , Japan

Page 2: Advisor : Cheng-Hsin Chuang Advisee ﹕ Tsan-Hsiu Li Department of Mechanical Engineering Southern Taiwan University Date ﹕ 2013/9/13 Paper Survey Design

2

Outline

Design Concept

Experiment Setup

Experiment Results Basic Experiment Human Lung Experiments Animal Lung Experiments

Clinical Application

Future Works

Page 3: Advisor : Cheng-Hsin Chuang Advisee ﹕ Tsan-Hsiu Li Department of Mechanical Engineering Southern Taiwan University Date ﹕ 2013/9/13 Paper Survey Design

u(t) = A1 sin(2πft) + A2

z(s0, t) = B1 sin(2πft + α) + B2

A1:amplitude of the vibrating component of the input forceA2:constant component of the input forceB1:amplitude of vibrating component of the displacement sensorB2:constant component of the output of the displacement sensor

Fig. 3. Overview of the prototype sensor head.

Design Concept

3

Fig. 2. Basic principle of noncontact tumor imager.

Air

In

pu

tS

enso

r ou

tpu

t

Lissajous Diagram

Page 4: Advisor : Cheng-Hsin Chuang Advisee ﹕ Tsan-Hsiu Li Department of Mechanical Engineering Southern Taiwan University Date ﹕ 2013/9/13 Paper Survey Design

Experiment Setup

Fig. 4. Basic experimental setup.

Page 5: Advisor : Cheng-Hsin Chuang Advisee ﹕ Tsan-Hsiu Li Department of Mechanical Engineering Southern Taiwan University Date ﹕ 2013/9/13 Paper Survey Design

5

f =40Hz Input pressure=0.15MPa Slider Speed =10mm/s

Basic Experiment With normal surface (white). With colored surface (red and black).

Silicone objectSilicone object

Page 6: Advisor : Cheng-Hsin Chuang Advisee ﹕ Tsan-Hsiu Li Department of Mechanical Engineering Southern Taiwan University Date ﹕ 2013/9/13 Paper Survey Design

6

Human Lung Experiments The normal tissue The tumor tissueInput pressure=0.15MPa

f =40Hz ds=10~20mm

Page 7: Advisor : Cheng-Hsin Chuang Advisee ﹕ Tsan-Hsiu Li Department of Mechanical Engineering Southern Taiwan University Date ﹕ 2013/9/13 Paper Survey Design

Animal Lung Experiments

7Fig. 10. Detection results of artificial tumors.

Input pressure=0.15MPa f =30Hz Di=5,8,10mm

Di/De ≥ 1 mm

Page 8: Advisor : Cheng-Hsin Chuang Advisee ﹕ Tsan-Hsiu Li Department of Mechanical Engineering Southern Taiwan University Date ﹕ 2013/9/13 Paper Survey Design

Clinical Application

8

(a)

(c)

Fig. 13. Example of the clinical test (right lobe, 72-year old male, [Di,De ]= [15, 34] mm based on CT). (a) CT image. (b) Overview of the measurement.(c) Real-time detection display

Fig. 12. Developed sensor system for clinical application. Overwiew of the developed sensor system.

Page 9: Advisor : Cheng-Hsin Chuang Advisee ﹕ Tsan-Hsiu Li Department of Mechanical Engineering Southern Taiwan University Date ﹕ 2013/9/13 Paper Survey Design

Conclusion

1) In a multicolored environment, whereas it is difficult for us to judge a consistent change from the output signal with respect to time.

2) It is desirable that the developed sensor is as small as possible and that it can detect tumors with a ratio of Di/De < 1.

9

Page 10: Advisor : Cheng-Hsin Chuang Advisee ﹕ Tsan-Hsiu Li Department of Mechanical Engineering Southern Taiwan University Date ﹕ 2013/9/13 Paper Survey Design

Future Works

10

Page 11: Advisor : Cheng-Hsin Chuang Advisee ﹕ Tsan-Hsiu Li Department of Mechanical Engineering Southern Taiwan University Date ﹕ 2013/9/13 Paper Survey Design

11

Thanks for your attention