  • ADXOverview & Applications

    Luke GohSnr Project Systems Engineer

    August 2008

  • 8/20/2008 ADC Proprietary and Confidential 2

    ADX - new patented active E1 DDF (Digital Distribution Frame) Combining and compacting a SDH STM-1 ADM and E1

    DACS into the dimension of Krone LSA-Plus and able to fitinto the existing Profil rod

    Zero touch Digital Distribution Frame for 2Mbps circuit

    ADX - General

  • 8/20/2008 ADC Proprietary and Confidential 3

    ADX - Passive versus Active

    Passive DDF Huge amount of copper

    cables between ADM andDDF

    Huge effort for the cableinstallation

    Limitation of the distancebetween ADM and Switch

    Problem with electricalinterference

    ADM SwitchPassive DDF

  • 8/20/2008 ADC Proprietary and Confidential 4

    ADX - Passive versus Active

    ADM SwitchActive DDF

    Active DDF Reduced cable cost Reduced installation cost Reduced footprint Reduced power consumption Reduced cabling space between

    ADM and DDF Increased distance between

    ADM and DDF Reduce the problem with

    electrical interference

  • 8/20/2008 ADC Proprietary and Confidential 5

    ADX Product Design - E1 Tributary Card

    The E1 Interface card is based onthe LSA-PLUS (IDC) connectiontechnologie. Use the LSA-PLUSinsertion tool to connect the wiresto the card.

    E1 Interface Card has eight 120ohms interface complying to ITU-TG.783.

    E1 interface : ADC101 2.048 Mb/s+/- 50 ppm, HDB3 coded signal.According ITU-T G.703-6

  • 8/20/2008 ADC Proprietary and Confidential 6GTA / BusseStand 09.11.2006

    Adapter Wire Wrap ( 17-poles )

    Adapter Coax 1.0/2.3 ( 16 Port )

    Adapter RJ45 ( 8 port)

    Adapter LEMO ( 8 Port )

    Adapter LSAPlus ( 16 ports)

    ADX Interfaces

    STM-1e(1.0/2.3)

    STM-1 LCS1.1 to L1.2

    STM-1 SC WDM

  • 8/20/2008 ADC Proprietary and Confidential 7

    ADX Product Portfolio

    ADX 100Profil rod mount

    ADX 20119 rack-mount

    ADX 20032 port19 rack-mount

  • 8/20/2008 ADC Proprietary and Confidential 8

    ADX 6 Value Propositions

    Capex and Opex savings = Cost Effective Offer Full functionality, any to any connections Extreme low Power consumption (< 14 W) Reduced wiring efforts, cable gainer Compact, save CO space Ease of use, reduce training cost anddependency on SDH skill-set

    SNMP network management

  • 8/20/2008 ADC Proprietary and Confidential 9

    Value Proposition - Full FunctionalityAny to Any Connections, VC-12 SNCP Protection

    63xE1

    63xE1 63

    xE1

    East West

    East

    East

    West

    West

    STM-1 Access Ring

    ADX Add/Drop, by-pass, cross-connect capability

    ADXADX ADX

  • 8/20/2008 ADC Proprietary and Confidential 10

    Value PropositionExtremely Low Power Consumption

    ADX 201 powered by PoE ethernet hub

  • 8/20/2008 ADC Proprietary and Confidential 11

    ADM Interconnection area

    ADM

    63 x E1 cables

    1 duplex fiber

    48V

    Passive DDF CharacteristicsSTM-16 ADM serves max. 1008E1

    This leads to 2016 copper pairsActive DDF Characteristics 1 duplex fiber per 63 E1s 16 duplex fiber, 16 ADX, 1008 E1 Reduced cable cost Reduced installation cost Reduced footprint Reduced power consumption Reduced cabling space betweenAADM and DDF Almost no distance limit

    Passive DDF (sideview)

    Active DDF (sideview)

    Value PropositionReduced Wiring Effort, Cable Gainer

  • 8/20/2008 ADC Proprietary and Confidential 12

    Value PropositionCompact, Save CO space

    Save space at the DDFequivalent to 2.6 MDF71 block

  • 8/20/2008 ADC Proprietary and Confidential 13

    Web browser GUI Local Management access via

    100BaseT SNMP with trap messages support Non-volatile software and database

    stores including back-up and restore In-band management via MS DCC

    channel using the overhead bytes Zero install No hidden cost

    Value PropositionEase of Use, reduced training cost

  • ADX Applications

  • 8/20/2008 ADC Proprietary and Confidential 15

    Non-intrusive E1 Monitoring

    Centralised E1 monitoringsolutions with the ADX family. Long distance between ADMs Minimum space requirements

    for this solution. Transparent & non-intrusive

    testing from a central point ofadministration.

    Remote controlled

  • 8/20/2008 ADC Proprietary and Confidential 16

    ADX Non-intrusive E1 monitoring

    ADM

    Centraloffice

    E1

    Centralised monitoringsolutions with the ADXfamily.

    E1 monitoring Distance not an

    issue Minimum space Remote control

    ADX

    STM 1

    Solitter 1x2VAM module

    E1

    ADX

    95%

    5%

  • 8/20/2008 ADC Proprietary and Confidential 17

    Rerouting BSC to Backup MSC

    Backup MSC

    Working MSC

    mFlexible test access

    ADXE1 E1

    BSC

    Backup MSC

    Working MSC

    mFlexible test access

    ADXE1

    BSC

    STM-1

    STM-1

  • 8/20/2008 ADC Proprietary and Confidential 18

    Data Center

  • 8/20/2008 ADC Proprietary and Confidential 19

    Siemens TRAU to Nokia MGW

  • 8/20/2008 ADC Proprietary and Confidential 20

    Nokia Transcoder to Ericsson MSC

  • 8/20/2008 ADC Proprietary and Confidential 21

    ADM 63xE1 drop to Siemens Surpass HT7070

  • 8/20/2008 ADC Proprietary and Confidential 22

    ADX 100 mounted in Siemens 75 ohms(2.3/5.6) frame

  • 8/20/2008 ADC Proprietary and Confidential 23

    3rd floor

    LP1

    LP1 LP2

    S1.1 STM-1

    Hua Wei OptixOSN 3500

    6th floorRoof Top

    ADX 100

    S1.1 STM-1

    ADX 100

    ADX 100 mounted in Siemens 75 ohms(2.3/5.6) frame

  • 8/20/2008 ADC Proprietary and Confidential 24

    ADX 100 w 63xE1 drop w LG WDCS-8000

  • 8/20/2008 ADC Proprietary and Confidential 25

    E1 grooming to Alcatel Router 7750

  • 8/20/2008 ADC Proprietary and Confidential 26

    ADX 4

    ADX 5

    ADX 6

    DXX

    BSC

    PCU

    Fibre 1

    Fibre 2

    Fibre 3

    Fibre 4

    Fibre 5

    STM 1

    STM 1

    STM 1E1

    Copper

    E1

    Copper

    E1

    Copper

    ADX 1

    ADX 2

    ADX 3

    Telkom

    MDF

    Flexibility it is possible to:

    Cross connect from ADX 1 to ADX 4, 5, 6

    Cross connect from ADX 2 to ADX 4, 5, 6

    Cross connect from ADX 3 to ADX 4, 5, 6

    Galvanic Isolation between Telkom incoming E1s and Telekomequipment

    Cable Gainer solution is used to route and protect the STM1single-mode fibre between the Telkom test and patch andactive equipment

    Cable Consolidation

  • 8/20/2008 ADC Proprietary and Confidential 27

    Cable Consolidation

  • 8/20/2008 ADC Proprietary and Confidential 28

    Cable Consolidation

  • 8/20/2008 ADC Proprietary and Confidential 29

    Profil rod-mount LO ADM 63xE1 Drop

  • 8/20/2008 ADC Proprietary and Confidential 30

    Wall-mounted LO ADM 63xE1 drop

  • 8/20/2008 ADC Proprietary and Confidential 31

    Controlled EnvironmentVault (CEV)

  • 8/20/2008 ADC Proprietary and Confidential 32

    ADX100 mounted in compact profile frame

  • ASXActive DDF with DSX

  • 8/20/2008 ADC Proprietary and Confidential 34

    ASX Front View

  • 8/20/2008 ADC Proprietary and Confidential 35

    ASX Physical Connection

    RJ45 100BaseTto LAN Switch

    2xSTM-1 LCfiber optic to

    MGW-48V DC

    power. 1A

    To fuse panel

    64 x E1s

  • 8/20/2008 ADC Proprietary and Confidential 36

    E1 connection viaFlexDSX wire-wrap

    ASX Physical Connection