aecom 312-939-1000 tel 303 e. wacker drive, suite 1400 ......2020/07/12  · aecom 312-939-1000 tel...

11
AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 312-939-4198 fax Chicago, Illinois 60606 C:\Users\kornders\Documents\2ndQrt2020\CDPH Ltr Rpt 401 N McClurg Ct.doc July 12, 2020 Mr. Jeff Musil Project Manager John Burns Construction Company 17601 Southwest Highway Orland Park, IL 60467 RE: Streeterville Thorium Monitoring Results – Small Cell Site CDPH Permit No.: CDOT1250968 Permit Address: 401 N. McClurg Ct., Chicago, Illinois AECOM Project No. 60616106 Dear Mr. Musil: Pursuant to conditions specified in the ROW form (attached) issued by the City of Chicago Department of Public Health (CDPH), radiation monitoring was required to be performed at the above referenced site. AECOM Technical Services, Inc. (AECOM) provided the required radiation surveillance on June 17-19, 22 and 24, 2020 for excavation required to install fiber and power conduit for a small cell site at 401 N. McClurg Ct. (refer to map included with ROW form). Surveying was performed in an open trench cut into the right of way near the intersection of McClurg Ct. and North Water St. Surveying was also performed in a pole foundation excavation at the southeast corner of the intersection. Refer to the attached photographs and drawing attached to the CDPH form for the approximate location of the excavations. The trench excavation was approximately 3-feet wide, 150- feet long, and excavated to a depth of 32-inches. Screening was performed every 15-feet of trench at 12- inch depth intervals for a total of 14 sections (see attached drawing and the gamma results table). The pole foundation was approximately 3 by 3 feet and excavated to a depth of approximately 10 feet. The monitoring did not indicate that the fill soils were above the removal action level established by the U.S. Environmental Protection Agency (USEPA) for the Streeterville area of Chicago. The USEPA removal action level for Chicago’s Streeterville area is 7.1 picocuries per gram (pCi/g) total radium (Ra- 226 + Ra-228). Gamma radiation count measurements for the project were recorded using a Ludlum Model 2221 survey meter and a shielded 2 x 2 inch Nal probe (Model 44-10). For the instrument used the gamma count threshold indicative of the 7.1 pCi/g removal action level is 6,818 (S/N: 326726) counts per minute (cpm) shielded utilizing a short cord and 4,991 cpm shielded with a long cord. The field instrument fill soil background measured nearby was 2,050 cpm long cord and 2,800 cpm short cord. Field gamma measurements within the excavation openings did not exceed the instrument thresholds previously stated and ranged from 1,560 cpm to a maximum reading of 3,040 cpm shielded. Based on field observations there was no indication of the presence of radiologically contaminated fill and/or an exceedance of the USEPA removal action level of 7.1 pCi/g total radium. A copy of the CDPH form, photographs and the tabulated gamma results are included as attachments. As part of the permit conditions, a PDF copy of this letter will be forwarded to Terry Sheahan (CDPH) and Verneta Simon (USEPA) to fulfill the requirements of the CDPH.

Upload: others

Post on 16-Mar-2021

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 ......2020/07/12  · AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 312-939-4198 fax Chicago, Illinois 60606 C:\Users\kornders\Documents\2ndQrt2020\CDPH

AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 312-939-4198 fax Chicago, Illinois 60606

C:\Users\kornders\Documents\2ndQrt2020\CDPH Ltr Rpt 401 N McClurg Ct.doc

July 12, 2020 Mr. Jeff Musil Project Manager John Burns Construction Company 17601 Southwest Highway Orland Park, IL 60467 RE: Streeterville Thorium Monitoring Results – Small Cell Site

CDPH Permit No.: CDOT1250968 Permit Address: 401 N. McClurg Ct., Chicago, Illinois

AECOM Project No. 60616106 Dear Mr. Musil:

Pursuant to conditions specified in the ROW form (attached) issued by the City of Chicago Department of Public Health (CDPH), radiation monitoring was required to be performed at the above referenced site. AECOM Technical Services, Inc. (AECOM) provided the required radiation surveillance on June 17-19, 22 and 24, 2020 for excavation required to install fiber and power conduit for a small cell site at 401 N. McClurg Ct. (refer to map included with ROW form).

Surveying was performed in an open trench cut into the right of way near the intersection of McClurg Ct. and North Water St. Surveying was also performed in a pole foundation excavation at the southeast corner of the intersection. Refer to the attached photographs and drawing attached to the CDPH form for the approximate location of the excavations. The trench excavation was approximately 3-feet wide, 150-feet long, and excavated to a depth of 32-inches. Screening was performed every 15-feet of trench at 12-inch depth intervals for a total of 14 sections (see attached drawing and the gamma results table). The pole foundation was approximately 3 by 3 feet and excavated to a depth of approximately 10 feet.

The monitoring did not indicate that the fill soils were above the removal action level established by the U.S. Environmental Protection Agency (USEPA) for the Streeterville area of Chicago. The USEPA removal action level for Chicago’s Streeterville area is 7.1 picocuries per gram (pCi/g) total radium (Ra-226 + Ra-228). Gamma radiation count measurements for the project were recorded using a Ludlum Model 2221 survey meter and a shielded 2 x 2 inch Nal probe (Model 44-10). For the instrument used the gamma count threshold indicative of the 7.1 pCi/g removal action level is 6,818 (S/N: 326726) counts per minute (cpm) shielded utilizing a short cord and 4,991 cpm shielded with a long cord. The field instrument fill soil background measured nearby was 2,050 cpm long cord and 2,800 cpm short cord.

Field gamma measurements within the excavation openings did not exceed the instrument thresholds previously stated and ranged from 1,560 cpm to a maximum reading of 3,040 cpm shielded. Based on field observations there was no indication of the presence of radiologically contaminated fill and/or an exceedance of the USEPA removal action level of 7.1 pCi/g total radium. A copy of the CDPH form, photographs and the tabulated gamma results are included as attachments.

As part of the permit conditions, a PDF copy of this letter will be forwarded to Terry Sheahan (CDPH) and Verneta Simon (USEPA) to fulfill the requirements of the CDPH.

Page 2: AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 ......2020/07/12  · AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 312-939-4198 fax Chicago, Illinois 60606 C:\Users\kornders\Documents\2ndQrt2020\CDPH

Permit No.: CDOT1250968 Permit Address: 401 N. McClurg Ct., Chicago, Il Page 2

C:\Users\kornders\Documents\2ndQrt2020\CDPH Ltr Rpt 401 N McClurg Ct.doc

Please contact us with any questions you have regarding this letter or the reported results.

Regards,

Eric Sulita, P.E. Steven C. Kornder, Ph.D. Environmental Engineer III Senior Project Geochemist cc: Terry Sheahan, Chicago Department of Public Health Verneta Simon, USEPA

Attachments: CDPH Permit Form and Map Photographs and Gamma Results

Page 3: AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 ......2020/07/12  · AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 312-939-4198 fax Chicago, Illinois 60606 C:\Users\kornders\Documents\2ndQrt2020\CDPH

CDPH PERMIT FORM

Page 4: AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 ......2020/07/12  · AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 312-939-4198 fax Chicago, Illinois 60606 C:\Users\kornders\Documents\2ndQrt2020\CDPH

DEPARTMENT OF PUBLIC HEALTH

CITY OF CHICAGO

(STREETERVILLE Right-of-Way) Notice is hereby given that the site you have requested a pennit for is recorded with the City of Chicago Department of Public Health (CDPH) as potentially having environmental contamination on the site and adjacent right-of way. This environmental contamination could present a threat to human health and safety in connection with work performed at the site, or in the adjacent right-of-way, if proper safeguards are not employed.

A file containing detailed information regarding the aforementioned environmental contamination is available for review at CDPH at 333 S. State St., Room 200, Chicago, Illinois 60604 during normal business hours (8:30AM-4:30PM, Monday through Friday). Contact (312) 745-3152 for an appointment. This file must be reviewed and the remainder of this form completed before the permit can be issued if the ground is exposed or excavated. Please note that for some locations, additional health and safety procedures may be required by law.

Please complete the following:

I have reviewed and understand the documents, maintained by CDPH, regarding environmental contamination of the site and adjacent right-of­way. Further, I will ensure that all work at the subject site and adjacent right-of-way, and any monitoring required including but not limited to radiation monitoring. wiJI be performed in a manner that is protective of human health and the environment and in compliance with all applicable local, state, and federal laws, rules, and regulations, especially those pertaining to worker safety and waste management. I will ensure that the results of any radiation monitoring and/or surveying conducted shaJI be provided to the CDPH and the United States Environmental Protection Agency within two (2) weeks of their completion. If any elevated levels of radioactive material are detected, I will immediately contact the United States Environmental Protection Agency at (800) 424-8802.

Applicant Name (print): Signature: ------------------

Site Address and Work Location (Describe exact site location and attach map):-----------------------

Nature of Work: --------------------------------------------­

Company Name, Address. Phone No.:

General/ Prin1e Contractor Name, Address, Phone No.: ------------------------------­Include subconrractor information !

f

applicahle)

Safety Officer/ Phone No. ------------------------------------------

Radiation Contractor I Phone No. and email address (if applicable) __________________________ _

Check if City Department Work D Department Name:

COOT Permit No.: ------- ------------

Today's Date: ______ _ Expected Start Date: CDPH Approval I Date--------------

Please return this completed fom1 to the Chicago Department of Transportation, Division of Infrastructure Management, Public Way Permit Office, City Hall - Room 905, 121 N. LaSalle St.. Chicago, Illinois 60602 during normal business hours (8:30 AM - 4:30 PM, Monday through Friday)

For CDPH Use Only

333 SOUTH STATE STREET. HOOM :.!00, ClilCAGO. ILLJNOIS 6060'1

DOT1250968

jeff.musil
Text Box
Jeffrey Musil, for John Burns Construction, on behalf of AT&T
jeff.musil
Text Box
Jeffrey Musil
jeff.musil
Text Box
401 N. McClurg Ct., Chicago, IL
jeff.musil
Text Box
Open cut trench to install fiber and power conduit for a proposed small cell site. Remove and replace pole foundation.
jeff.musil
Text Box
AT&T
jeff.musil
Text Box
John Burns Construction, 17601 Southwest Hwy, Orland Park, IL 60467, 708-326-3500
jeff.musil
Text Box
Kevin O'Leary, 312-550-6059
jeff.musil
Text Box
AECOM Consultants, 312-373-7700
jeff.musil
Text Box
N/A
jeff.musil
Text Box
6/5/2020
jeff.musil
Text Box
6/15/2020
Page 5: AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 ......2020/07/12  · AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 312-939-4198 fax Chicago, Illinois 60606 C:\Users\kornders\Documents\2ndQrt2020\CDPH

NC

NC

NC

NC

NC

NC

NC

NC

BUILDINGBUILDING

BUILDING

DRIVE

NC

44'

\A1;44'

66'

\A1;66'

193'

\A1;193' 108'\A1;108'

40'

\A1;40'

169'

\A1;169'45' \A1;45'

89'

E N

OR

TH

WA

TE

RN McCLURG

CWALKCWALK

CW

AL

K

CW

AL

K

CWALK

DR

IVE

CWALK

CWALK

COORDINATE WITH BUILDING

OWNERS/ MANAGEMENT AND

PROJECT DEVELOPMENT FOR

DECORATIVE STREETSCAPE ADA

REPLACEMENT

1205 SQUARE YARDS OF ASPHALT

RESTORATION CONTRACTOR TO MATCH

EXISTING PAVEMENT JOINT

4 SQUARE YARDS OF PARKWAY

RESTORATION (A-3-1)

COORDINATE WITH BUILDING

OWNER OR PROJECT

DEVELOPMENT

REMOVE AND REINSTALL 2 SQUARE

YARDS OF EXISTING PAVERS; PAVER TO

BE REPLACED IN KIND (COLOR AND

MATERIAL) IF PAVERS DAMAGED

REPLACE ADA RAMPS PER CDOT

REGULATIONS

REPLACE ADA RAMPS PER CDOT

REGULATIONS

DO NOT IMPACT GRANITE RAMPS

REPLACE ADA RAMPS PER CDOT

REGULATIONS

DRAWN BY:

NO. DATE DESCRIPTION

SHEET NUMBER

OF 20

CJ

REVISIONS

PERMIT

DATE DRAWN:

6/26/18

PROJECT

NUMBER:DASC-1883-003-U06R

TITLE:

ENGINEER:

OWNER:

DEVELOPER:

OUC

NUMBER:EFP-101563

DRAWING SCALE:

OUTSIDE PLANT FIBER

OPTIC BUILD

AT&T DEARBORN

(NODE #06)

401 N MCCLURG CT,

CHICAGO, IL 60611

2649 GARDNER RD

BROADVIEW, IL 60155

OFFICE 630.572.9999

FAX 630.572.9998

930 NATIONAL PKWY.

SCHAUMBURG, IL 60173

OFFICE 847.592.3000

1351 E. IRVING PARK RD.

ITASCA, IL 60143

OFFICE 847.463.5950

FAX 630.250.1353

6/26/18

SEWER REV.17 9/18/19

RESUBMITTAL01/28/20

RCN REV.18 02/05/20

WATER & COMCAST19 02/17/20

MWRD REV.20 02/24/20

COMED REV.21 02/27/20

SEWER REV.22 03/10/20

{\LRESTORATION QUANTITY (TOTAL JOB)\P}ASPHALT W/ HMA BINDER COURSE 0 SQ. YD.{\L\P}ASPHALT W/O HMA BINDER COURSE 1205 SQ. YD.\PSIDEWALK PAVER 2 SQ. YD.; PAVER TO BE REPLACED IN KIND (COLOR AND MATERIAL) IF PAVERS DAMAGED\PPARKWAY 4 SQ. YD.\P(QUANTITY IS ESTIMATED AND SUBJECT TO CHANGE AT CONSTRUCTION)

RESTORATION QUANTITY (TOTAL JOB)

ASPHALT W/ HMA BINDER COURSE 0 SQ. YD.

ASPHALT W/O HMA BINDER COURSE 1205 SQ. YD.

SIDEWALK PAVER 2 SQ. YD.; PAVER TO BE REPLACED IN KIND (COLOR AND MATERIAL) IF PAVERS DAMAGED

PARKWAY 4 SQ. YD.

(QUANTITY IS ESTIMATED AND SUBJECT TO CHANGE AT CONSTRUCTION)

{\LRESTORATION NOTE:\P\P}1. ALL RESTORATION SHALL COMPLY WITH CDOT RULES AND REGULATIONS, LATEST EDITION.\P\pxt35;2. CONTRACTOR SHALL SEAL THE FULL PERIMETER OF ASPHALT RESTORATION LIMITS WITH HOT POURED JOINT SEALER, AS PER IDOT STANDARDS. \P\ptz;3. IF ASPHALT RESTORATION LIMIT IS LESS THAN 4' FROM THE CROSSWALK, THEN THE REPLACEMENT OF THE ADA RAMPS IS REQUIRES (IF NONCOMPLIANT)

RESTORATION NOTE:

1. ALL RESTORATION SHALL COMPLY WITH CDOT RULES AND REGULATIONS,

LATEST EDITION.

2. CONTRACTOR SHALL SEAL THE FULL PERIMETER OF ASPHALT

RESTORATION LIMITS WITH HOT POURED JOINT SEALER, AS PER IDOT

STANDARDS.

3. IF ASPHALT RESTORATION LIMIT IS LESS THAN 4' FROM THE CROSSWALK,

THEN THE REPLACEMENT OF THE ADA RAMPS IS REQUIRES (IF

NONCOMPLIANT)

1919

PAVEMENT RESTORATION

AS NOTED

20'

1" = 20'HORIZONTAL SCALE OF DRAWING

10' 0 20'

N

{\LNOTE:} \PCOORDINATE WORK HOURS AND SCHEDULING WITH CDOT-PERMITS PRIOR TO START OF WORK.

NOTE:

COORDINATE WORK HOURS AND

SCHEDULING WITH CDOT-PERMITS PRIOR

TO START OF WORK.

ASPHALT STREET

RESTORATION:

CONCRETE ALLEY

RESTORATION:

CONCRETE ALLEY APRON

RESTORATION:

ASPHALT ALLEY

RESTORATION:

CONCRETE SIDEWALK

RESTORATION:

CONCRETE STREET

RESTORATION:

SIDEWALK PAVER

RESTORATION:

RESTORATION LEGEND

AND SUMMARY

CURB AND GUTTER

RESTORATION:

2 SY

1205 SY

00 SY

00 SY

00 SY

00 SY

4 SY

0 LF

DESCRIPTION

VISIONVISIONVISIONSIONISIONSIONISIONISIONSIONSIONSIO SSSSSSSSSS

PERMIT

SEWER REV.

RESUBMITTAL

RCN RERCN REVRCN RERCN RRCN RERCN RERCN RERCN RERCN REVRCN REVN REVRCN REVRCN REVRCN REVN REVRCN RCN REEVN REVREE ..

WATER &ATER &ATEATER &ATER &ATER TER &ATER &ATER &ATER &ATER &ATER &ATER &ATER &ATER &ER &ER &ER &ATER &ATER & COMCASCOMCASCOMCCOMCASCCOMCASCOCOMCCOMCASCOCOCOMCASCOMCASCOMCCOCOCOMCASCOCO TTTTTTTT

MWRD REMMWRDMWRD RMWRD REMWRD REMWRD RMWRD RMWRD RMWRD RMWRD REMWRD REMWRDMWRD REEMWRD RMWRD WRD EVVV.VVVV.VV

EFP-101563

03/20/20

7/28/2020 3:36:37 PM

1413121110

9

8

764 123 5Lightpole Foundation

Sulita, Eric
Rectangle
Sulita, Eric
Rectangle
Sulita, Eric
Rectangle
Sulita, Eric
Rectangle
Sulita, Eric
Rectangle
Sulita, Eric
Rectangle
Sulita, Eric
Rectangle
Sulita, Eric
Rectangle
Sulita, Eric
Rectangle
Sulita, Eric
Rectangle
Sulita, Eric
Rectangle
Sulita, Eric
Rectangle
Sulita, Eric
Rectangle
Sulita, Eric
Rectangle
Sulita, Eric
Rectangle
Sulita, Eric
Arrow
Page 6: AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 ......2020/07/12  · AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 312-939-4198 fax Chicago, Illinois 60606 C:\Users\kornders\Documents\2ndQrt2020\CDPH

W

W

CMCT

W

S

S

S

S

S

S

W W

W

W

CE

CE

E

E

SBC

W

G

G

G

NC

NC

NC

NC

NCNC

NC

NC

RCN

RCN

BUILDING

BUILDING

DR

IVE

0368018

0368034

15062

E N

OR

TH

WA

TE

R

N McCLURG

9.91'

\A1;9.91'

14.35'

5.8

7'

5.2

1'

\A1;5.21'

2.44'

\A1;2.44'

19.6

0'

\A1;19.60'

3.57'

\A1;3.57'

25.10'

\A1;25.10'

0+

00 1+00 1+11

0+

00

0+89

4.00'

\A1;4.00'

2.00'

\A1;2.00'

2.00'

\A1;2.00'

CMCT

4.02'

PROPOSED UNDERGROUND

(1)- 16/13 2-WAY

MICRODUCT, 112' LONG @ A

MINIMUM DEPTH OF 48" BY

OPEN CUT/TRENCH

SEE WATER NOTE

(3 FT MAX. TRENCH)

SEE COMED NOTE

SEE COMED NOTE

STA 0+22

STA 1+11A

STA 0+00

CONTRACTOR TO REMOVE EXISTING

LIGHT POLE AND FOUNDATION.

REPLACE WITH NEW FOUNDATION

(DEO SPECIFICATION# 818 - 9'-0” DEEP)

AND NEW POLE (CDOT DEO

SPECIFICATION #907) (SEE SHEET 6

FOR DETAILS)

DEARBORN NODE #6

LAT: 41.889447

LONG: -87.617442

11.14' NSL (NORTH WATER)

2.49' WEL (McCLURG)

STA 0+03

PROPOSED 25" x 15" QUAZITE BOX

10.72' NSL (NORTH WATER)

2.01' EEL (McCLURG)

PROPOSED UNDERGROUND

(1)- SINGLE MICRODUCT &

(1)-1.25" PVC SCH. 80 CONDUIT,

2' LONG @ A MINIMUM DEPTH

OF 48" BY OPEN CUT/TRENCH

PROPOSED UNDERGROUND (1)- 16/13

2-WAY MICRODUCT & (1)-2.00" PVC SCH. 40

CONDUIT, 22' LONG @ A MINIMUM DEPTH

OF 48" BY OPEN CUT/TRENCH

SEE COMED NOTE

STA. 0+89

CONNECT TO EXISTING COMED

MH # 368018

19.54' SNL (NORTH WATER)

48.02' EEL (McCLURG)

PROPOSED UNDERGROUND (1)-2.00" PVC

SCH. 40 CONDUIT, 57' LONG @ A MINIMUM

DEPTH OF 48" BY OPEN CUT/TRENCH

SEE GAS NOTE

SEE GAS NOTE

SEE WATER NOTE

(3 FT MAX. TRENCH)

SEE GAS NOTE

36" SEWER SUPPORT,

SEE SHTS, 9 & 10 FOR

DETAILS

W

STA. 0+00A

CONNECT TO EXISTING

SBC MH # 15062

25.07' NSL (NORTH WATER)

7.30' WWL (McCLURG)

E

BUILDING

W

SEE SEWER NOTE

SEE SEWER NOTE

0+00

-05

00

05

10

15

-05

00

05

10

15

0+00A 0+50A 1+00A

-05

00

05

10

15

-05

00

05

10

15

18" MIN.18" MIN.

18" MIN.

18" MIN.

\A1;18" MIN.

0+50 1+00

18

" M

IN.

18

" M

IN.

18

" M

IN.

18" MIN.

\A1;18" MIN.

18

" M

IN.

\A1;18" MIN.

18" MIN.

18" MIN.

48" MIN. 48" MIN.36"

CONNECT SBC

MH #15062

TOP OF

PAVEMENT

(McCLURG)

PROPOSED

CONDUIT(S)

16" WATER12" WATER

CONNECT TO COMED

MH #368018 TOP OF PAVEMENT

(McCLURG)

PROPOSED

CONDUIT(S)

12" WATERSBC

4-COMED DEORCN8-COMED

24" STORM

(SEE SEWER NOTE)

12" STORM

2.56' INVERT

(SEE SEWER NOTE)

36" STORM

(SEE SEWER

SUPPORT DETAILS)

SBC

RCN8" GAS

STA 0+22

STA 1+11A

PROPOSED 25" x 15"

QUAZITE BOX

CONNECT TO

PROPOSED POLE

20 COMED

4" GAS

STA 1+09

STA 0+22A

2" GAS

8" GAS

18

" M

IN.

\A1;18" MIN.

DRAWN BY:

NO. DATE DESCRIPTION

SHEET NUMBER

OF 20

CJ

REVISIONS

PERMIT

DATE DRAWN:

6/26/18

PROJECT

NUMBER:DASC-1883-003-U06R

TITLE:

ENGINEER:

OWNER:

DEVELOPER:

OUC

NUMBER:EFP-101563

DRAWING SCALE:

OUTSIDE PLANT FIBER

OPTIC BUILD

AT&T DEARBORN

(NODE #06)

401 N MCCLURG CT,

CHICAGO, IL 60611

2649 GARDNER RD

BROADVIEW, IL 60155

OFFICE 630.572.9999

FAX 630.572.9998

930 NATIONAL PKWY.

SCHAUMBURG, IL 60173

OFFICE 847.592.3000

1351 E. IRVING PARK RD.

ITASCA, IL 60143

OFFICE 847.463.5950

FAX 630.250.1353

6/26/18

SEWER REV.17 9/18/19

RESUBMITTAL01/28/20

RCN REV.18 02/05/20

WATER & COMCAST19 02/17/20

MWRD REV.20 02/24/20

COMED REV.21 02/27/20

SEWER REV.22 03/10/20

{\LLOCATION: SEC 3, T39N-R14E,\PCHICAGO, COOK COUNTY, ILLINOIS}

LOCATION: SEC 3, T39N-R14E,

CHICAGO, COOK COUNTY, ILLINOIS

AS NOTED

{\fArial|b1|i0|c0|p34;\LCONSTRUCTION NOTE:\fArial|b0|i0|c0|p34;\P}FOR FIBER PULL ASSISTANCE, LEAVE STRATEGIC PULL ACCESS POINTS EXPOSED AND PLATED (WHEN NOT UNDER CONSTRUCTION) UNTIL THE FIBER PULL IS COMPLETED. ONCE THE PULL IS COMPLETED, INSTALL SPLIT DUCT ON EXPOSED ROUTE AND ENCASE IN CONCRETE. ALL RESTORATION SHOULD BE IN COMPLIANCE WITH CDOT RESTORATION GUIDELINES. (SEE SHEET 5 FOR FURTHER DETAIL.)

CONSTRUCTION NOTE:

FOR FIBER PULL ASSISTANCE, LEAVE STRATEGIC

PULL ACCESS POINTS EXPOSED AND PLATED

(WHEN NOT UNDER CONSTRUCTION) UNTIL THE

FIBER PULL IS COMPLETED. ONCE THE PULL IS

COMPLETED, INSTALL SPLIT DUCT ON EXPOSED

ROUTE AND ENCASE IN CONCRETE. ALL

RESTORATION SHOULD BE IN COMPLIANCE WITH

CDOT RESTORATION GUIDELINES. (SEE SHEET 5

FOR FURTHER DETAIL.)

2020

20'

1" = 20'HORIZONTAL SCALE OF DRAWING

10' 0 20'

PLAN

{\fArial|b1|i0|c0|p34;\LCOMED NOTE:}\PHAND DIG IS REQUIRED WHEN CROSSING COMED UNDERGROUND CABLE/CONDUITS. MAINTAIN 12 INCHES VERTICAL CLEARANCE (18 INCHES IF POSSIBLE) FROM ANY COMED FACILITIES. WHEN FIELD CONDITIONS REQUIRE COMED ASSISTANCE, PLEASE CONTACT COMED NEW BUSINESS @ 1-866-NEW-ELEC TO REACH OUT TO A PROJECT ENGINEER AT LEAST 5 WEEKS PRIOR TO CONSTRUCTION. PROJECT IS IN LINDSAY LIGHT STREETERVILLE THORIUM MONITORIING AREA, SOIL SAMPLING/MONITORING IS REQUIRED.

COMED NOTE:

HAND DIG IS REQUIRED WHEN CROSSING

COMED UNDERGROUND

CABLE/CONDUITS. MAINTAIN 12 INCHES

VERTICAL CLEARANCE (18 INCHES IF

POSSIBLE) FROM ANY COMED FACILITIES.

WHEN FIELD CONDITIONS REQUIRE

COMED ASSISTANCE, PLEASE CONTACT

COMED NEW BUSINESS @

1-866-NEW-ELEC TO REACH OUT TO A

PROJECT ENGINEER AT LEAST 5 WEEKS

PRIOR TO CONSTRUCTION. PROJECT IS IN

LINDSAY LIGHT STREETERVILLE THORIUM

MONITORIING AREA, SOIL

SAMPLING/MONITORING IS REQUIRED.

{\fArial|b1|i0|c0|p34;\LGAS NOTE:\fArial|b0|i0|c0|p34;\P}PEOPLES GAS FACILITIES ARE PRESENT WITHIN AREA OF CONSTRUCTION. USE EXTREME CAUTION NEAR ALL GAS FACILITIES DURING CONSTRUCTION AND RELATED EXCAVATION ACTIVITIES. HAND EXCAVATION IS REQUIRED TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF GAS MAIN(S) PRIOR TO CROSSING AND WORKING WITHIN 3 FEET OF ALL GAS FACILITIES. A MINIMUM OF 3' HORIZONTAL EDGE TO EDGE CLEARANCE IS REQUIRED FOR GAS MAINS WITH DIAMETERS OF 16" OR SMALLER, AND 5FT

GAS NOTE:

PEOPLES GAS FACILITIES ARE PRESENT

WITHIN AREA OF CONSTRUCTION. USE

EXTREME CAUTION NEAR ALL GAS FACILITIES

DURING CONSTRUCTION AND RELATED

EXCAVATION ACTIVITIES. HAND EXCAVATION

IS REQUIRED TO FIELD VERIFY THE

HORIZONTAL AND VERTICAL LOCATION OF

GAS MAIN(S) PRIOR TO CROSSING AND

WORKING WITHIN 3 FEET OF ALL GAS

FACILITIES. A MINIMUM OF 3' HORIZONTAL

EDGE TO EDGE CLEARANCE IS REQUIRED

FOR GAS MAINS WITH DIAMETERS OF 16" OR

SMALLER, AND 5FT EDGE TO EDGE

CLEARANCE FOR GAS MAINS WITH

DIAMETERS 18" AND LARGER. MAINTAIN A

MINIMUM OF 18” EDGE TO EDGE VERTICAL

CLEARANCE ON GAS MAINS 16" OR LESS IN

DIAMETER, AND 24" EDGE TO EDGE VERTICAL

CLEARANCE ON 18" AND LARGER DIAMETER

GAS MAINS. CONTACT DIGGER 312-744-7000

FOR LOCATES 48 HOURS PRIOR TO START OF

CONSTRUCTION.

THE USE OF CONCRETE, FLOW FILL, OR THE

LIKE IS PROHIBITED WITHIN 24 INCHES OF

ALL GAS FACILITIES, NOR SHALL IT ENCASE

ANY GAS FACILITY. A MINIMUM OF 6” FA-02 OR

FM-02 SAND SHALL BE USED WHEN

BACKFILLING AROUND ANY EXPOSED GAS

FACILITY. CONTRACTOR EXPOSING GAS

FACILITY IS RESPONSIBLE FOR PROVIDING

THE SAND.

PEOPLES GAS CAST IRON AND DUCTILE IRON

GAS MAINS MAY REQUIRE SUPPORT DURING

CONSTRUCTION AND RELATED EXCAVATION

ACTIVITIES. ANY EXPOSED JOINTS MUST BE

SUPPORTED AND CAST IRON JOINTS SEALED

BY GAS COMPANY PERSONNEL. CONTACT

CENTRAL SHOP ENGINEERING

SUPERVISOR,JOSHUA AUMICK, 773-542-7971,

A MINIMUM OF 5 BUSINESS DAYS PRIOR TO

EXCAVATION TO SET UP ON-SITE

INSPECTION. INSPECTION BY PEOPLES GAS

IS REQUIRED PRIOR TO BACK FILL.

N

PROFILE1" = 5'VERTICAL SCALE

0 5 102.53.755

{\fArial|b1|i0|c0|p34;\LRCN NOTE:\fArial|b0|i0|c0|p34;\P}RCN FACILITIES ARE PRESENT IN THE AREA OF CONSTRUCTION. USE EXTREME CAUTION NEAR ALL RCN FACILITIES. HAND EXCAVATION IS REQUIRED TO LOCATE AND EXPOSE FIBER OPTIC FACILITIES PRIOR TO CROSSING AND WHEN WORKING WITHIN 3 FEET OF ALL RCN FACILITIES. CONTACT DIGGER FOR LOCATES A MINIMUM OF 48 HOURS PRIOR TO START OF CONSTRUCTION.

RCN NOTE:

RCN FACILITIES ARE PRESENT IN THE AREA OF

CONSTRUCTION. USE EXTREME CAUTION NEAR ALL

RCN FACILITIES. HAND EXCAVATION IS REQUIRED

TO LOCATE AND EXPOSE FIBER OPTIC FACILITIES

PRIOR TO CROSSING AND WHEN WORKING WITHIN 3

FEET OF ALL RCN FACILITIES. CONTACT DIGGER

FOR LOCATES A MINIMUM OF 48 HOURS PRIOR TO

START OF CONSTRUCTION.

{\fArial|b1|i0|c0|p34;\LWATER NOTE:}\P{\H0.83333x;A REPRESENTATIVE OF THE DWM MUST BE PRESENT DURING THE EXCAVATION AND INSTALLATION NEAR THE EXISTING 16-INCH FEEDER MAIN. IT IS REQUIRED THAT THE FORCE ACCOUNT CONSTRUCTION MANAGER BE CONTACTED AT \L\C0;[email protected]\l\C256; TWO WEEKS PRIOR TO THE ANTICIPATED CONSTRUCTION DATE SO A RESIDENT ENGINEER CAN BE ASSIGNED TO THE PROJECT.\~ THE DWM REPRESENTATIVE WILL ADHERE TO THE SCHEDULE PROVIDED BY CCSI NETWORKS, UNLESS NOTIFIED OTHERWISE.\fArial

WATER NOTE:

A REPRESENTATIVE OF THE DWM MUST BE PRESENT DURING

THE EXCAVATION AND INSTALLATION NEAR THE EXISTING

16-INCH FEEDER MAIN. IT IS REQUIRED THAT THE FORCE

ACCOUNT CONSTRUCTION MANAGER BE CONTACTED AT

[email protected] TWO WEEKS PRIOR TO THE

ANTICIPATED CONSTRUCTION DATE SO A RESIDENT ENGINEER

CAN BE ASSIGNED TO THE PROJECT.  THE DWM

REPRESENTATIVE WILL ADHERE TO THE SCHEDULE PROVIDED

BY CCSI NETWORKS, UNLESS NOTIFIED OTHERWISE. FAILURE TO

COMPLY WITH THIS REQUIREMENT MAY RESULT IN ADDITIONAL

EXPENSES TO THE PROPOSED PROJECT TO VERIFY THAT ALL

WORK CONFORMS TO DWM'S STANDARDS.

HAND EXCAVATION IS REQUIRED TO FIELD VERIFY THE

HORIZONTAL AND VERTICAL LOCATION OF THE 16-INCH WATER

MAIN PRIOR TO CROSSING.  IF A TRENCHLESS METHOD OF

INSTALLATION IS USED, A MINIMUM 4-FOOT OF UNDISTURBED

SOIL IS TO REMAIN ON EITHER SIDE OF THE EXISTING WATER

MAIN.  IF THE PROPOSED FACILITY WILL BE INSTALLED VIA

OPEN-CUT METHOD, THE EXCAVATION MUST BE PROPERLY

SHORED TO MAINTAIN A MAXIMUM 3-FOOT TRENCH WIDTH.  THE

TRENCH SHALL BE BACKFILLED TO THE SPRINGLINE OF THE

WATER MAIN WITH CLSM BACKFILL (NON-FLY ASH), AND CA-16

FROM THE SPRINGLINE OF THE WATER MAIN TO GRADE. USE OF

POLYETHYLENE WRAP AS A BOND BREAKER BETWEEN THE

WATER MAIN AND THE CLSM BACKFILL IS REQUIRED .  FAILURE

TO COMPLY WITH THESE REQUIREMENTS MAY RESULT IN

ADDITIONAL EXPENSES TO THE PROPOSED PROJECT TO VERIFY

THAT ALL WORK CONFORMS TO DWM'S STANDARDS. 

{\fArial|b1|i0|c0|p34;\LCOMCAST NOTE:\fArial|b0|i0|c0|p34;\P}COMCAST HAS EXISTING UNDERGROUND IN THE AREA. PLEASE PROCEED WITH EXTREME CAUTION, MAKE SURE TO CALL DIGGER PRIOR TO START EXCAVATION, USE HAND DIGGING IN THE AREAS WHERE COMCAST FACILITIES ARE MARKED. PLEASE BE NOTED THAT COMCAST HAS RESERVES THE RIGHT TO MAINTAIN, REPLACE AND RELOCATE THEIR FACILITIES IF NEEDED AND THE COST IS 100% BILLABLE TO REQUESTER

COMCAST NOTE:

COMCAST HAS EXISTING UNDERGROUND IN THE

AREA. PLEASE PROCEED WITH EXTREME CAUTION,

MAKE SURE TO CALL DIGGER PRIOR TO START

EXCAVATION, USE HAND DIGGING IN THE AREAS

WHERE COMCAST FACILITIES ARE MARKED. PLEASE

BE NOTED THAT COMCAST HAS RESERVES THE

RIGHT TO MAINTAIN, REPLACE AND RELOCATE

THEIR FACILITIES IF NEEDED AND THE COST IS 100%

BILLABLE TO REQUESTER

{\fArial|b1|i0|c0|p34;\LMWRD NOTE:}\P{\H0.83333x;THE DISTRICT HAS FACILITIES ALONG THE NORTH WATER STREET. DISTRICT FACILITIES SHALL BE LOCATED PRIOR TO PROCEEDING WITH ANY CONSTRUCTION WORK. NO HEAVY CONSTRUCTION EQUIPMENTS AND DRIVING OF SHEET PILES IN THE VICINITY OF DISTRICT FACILITIES SHALL BE ALLOWED. IT IS REQUESTED THAT DURING CONSTRUCTION EXTRA CAUTION BE TAKEN FOR THE SAFETY AND INTEGRITY OF OUR FACILITIES. ALL ACCESS HATCHES/MANHOLE COVERS ON DISTRICT STRUCTURES/MANHOLES WITHIN PROJEC

MWRD NOTE:

THE DISTRICT HAS FACILITIES ALONG THE NORTH WATER

STREET. DISTRICT FACILITIES SHALL BE LOCATED PRIOR TO

PROCEEDING WITH ANY CONSTRUCTION WORK. NO HEAVY

CONSTRUCTION EQUIPMENTS AND DRIVING OF SHEET PILES IN

THE VICINITY OF DISTRICT FACILITIES SHALL BE ALLOWED. IT IS

REQUESTED THAT DURING CONSTRUCTION EXTRA CAUTION BE

TAKEN FOR THE SAFETY AND INTEGRITY OF OUR FACILITIES. ALL

ACCESS HATCHES/MANHOLE COVERS ON DISTRICT

STRUCTURES/MANHOLES WITHIN PROJECT AREA SHALL NOT BE

BURIED/COVERED. NO DEBRIS SHALL ENTER THE DISTRICT

STRUCTURES/SEWERS/FACILITIES

{\fArial|b1|i0|c0|p34;\LSEWER NOTE:\fArial|b0|i0|c0|p34;\P}THERE ARE NO AVAILABLE RECORDS FOR THE EXIST. 12” AND 24” DIAMETER SEWER PIPE INVERTS AT PROPOSED CONDUIT CROSSINGS. THEREFORE, PRIOR TO CONSTRUCTION CONTRACTOR SHALL VERIFY SEWER INVERTS. SEWER PIPE SUPPORTS WILL BE REQUIRED IF INSTALLATION OF CONDUITS ARE TO BE INSTALLED BELOW. IN THIS CASE, CONTRACTOR SHALL NOTIFY ENGINEER OF RECORD AND DWM- SEWER SECTION IMMEDIATELY FOR RESOLUTION. \P\P\P\P

SEWER NOTE:

THERE ARE NO AVAILABLE RECORDS FOR

THE EXIST. 12” AND 24” DIAMETER SEWER

PIPE INVERTS AT PROPOSED CONDUIT

CROSSINGS. THEREFORE, PRIOR TO

CONSTRUCTION CONTRACTOR SHALL

VERIFY SEWER INVERTS. SEWER PIPE

SUPPORTS WILL BE REQUIRED IF

INSTALLATION OF CONDUITS ARE TO BE

INSTALLED BELOW. IN THIS CASE,

CONTRACTOR SHALL NOTIFY ENGINEER OF

RECORD AND DWM- SEWER SECTION

IMMEDIATELY FOR RESOLUTION.

DESCRIPTION

VISIONVISIONVISIONSIONISIONSIONISIONISIONSIONSIONSIO SSSSSSSSSS

PERMIT

SEWER REV.

RESUBMITTAL

RCN RERCN REVRCN RERCN RRCN RERCN RERCN RERCN RERCN REVRCN REVN REVRCN REVRCN REVRCN REVN REVRCN RCN REEVN REVREE ..

WATER &ATER &ATEATER &ATER &ATER TER &ATER &ATER &ATER &ATER &ATER &ATER &ATER &ATER &ER &ER &ER &ATER &ATER & COMCASCOMCASCOMCCOMCASCCOMCASCOCOMCCOMCASCOCOCOMCASCOMCASCOMCCOCOCOMCASCOCO TTTTTTTT

MWRD REMMWRDMWRD RMWRD REMWRD REMWRD RMWRD RMWRD RMWRD RMWRD REMWRD REMWRDMWRD REEMWRD RMWRD WRD EVVV.VVVV.VV

EFP-101563

03/20/20

7/28/2020 3:36:37 PM

Page 7: AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 ......2020/07/12  · AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 312-939-4198 fax Chicago, Illinois 60606 C:\Users\kornders\Documents\2ndQrt2020\CDPH

PHOTOGRAPHS AND GAMMA RESULTS

Page 8: AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 ......2020/07/12  · AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 312-939-4198 fax Chicago, Illinois 60606 C:\Users\kornders\Documents\2ndQrt2020\CDPH

PICTURE 1: VIEW OF THE TRENCH EXCAVATION AT THE INTERSECTION OF MCCLURG CT AND NORTH WATER ST (LOOKING NORTHWEST).

Page 9: AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 ......2020/07/12  · AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 312-939-4198 fax Chicago, Illinois 60606 C:\Users\kornders\Documents\2ndQrt2020\CDPH

PICTURE 2: VIEW OF THE TRENCH EXCAVATION AT THE INTERSECTION OF MCCLURG CT AND NORTH WATER ST (LOOKING EAST)

Page 10: AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 ......2020/07/12  · AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 312-939-4198 fax Chicago, Illinois 60606 C:\Users\kornders\Documents\2ndQrt2020\CDPH

PICTURE 3: VIEW OF THE LIGHT POLE FOUNDATION EXCAVATION AT THE SOUTHEAST CORNER OF MCCLURG CT AND NORTH WATER ST.

Page 11: AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 ......2020/07/12  · AECOM 312-939-1000 tel 303 E. Wacker Drive, Suite 1400 312-939-4198 fax Chicago, Illinois 60606 C:\Users\kornders\Documents\2ndQrt2020\CDPH

Location Depth (inches)Maximum 

Readings (cpm)  Location Depth (inches)Maximum 

Readings (cpm) 0‐12 concrete 0‐6 top soil12 1,900 18 2,10024 1,850 30 2,80032 2040 44 2,4000‐12 concrete 60 1,76012 1,850 80 1,69024 2,040 96 1,59032 2,550 110 1,5600‐12 concrete 122 1,62012 1,760 Notes:  ‐ Long cord24 2,32032 3,0400‐12 concrete12 1,80024 2,22032 2,8500‐12 concrete12 1,70024 1,99032 2,2800‐12 concrete12 1,80024 2,05032 2,3900‐12 concrete12 2,82524 2,10032 2,0800‐12 concrete12 2,05024 2,17032 2,1900‐12 concrete12 1,95024 2,28032 1,8600‐12 concrete12 1,79024 2,12032 2,3200‐12 concrete12 1,85024 1,99532 2,0800‐12 concrete12 1,80024 1,97032 2,1600‐12 concrete12 2,20024 2,01032 2,1500‐12 concrete12 2,10024 2,09032 2,100

Gamma Survey ResultsJohn Burns Construction Company

11

12

13

14

Light Pole (Hydro‐Vac)*

6

7

8

9

10

3

5

4

Survey Results

6,818 cpm short cord

Survey Equipment

Ludlum 2221 S/N: 326720CDOT: 1250968

1

2

6/17, 18, 19, 22 and 24/2020

Date of Screening:

Location: 401 N. McClurg Ct.

E. Sulita

2,800 cpm short cord

Personnel:

Cutoff:4,991 cpm long cord

Background:2,050 cpm long cord

U:\60616106_John_Burns\400_Technical\Task 200 ‐ 401 N McClurg\Report\Gamma Results.xlsx