1 FLOWAY HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 16.674 A Air handling unit The FLOWAY dual-flow air handling unit is a PLUG & PLAY ventilation unit equipped with a highly efficient heat recovery unit with plug fans and high performance EC motors, designed to meet all the requirements of recent ecodesign regulations. Unit supplied ready to use, prewired, preprogrammed in the factory and supplied with a remote control. It draws clean, fresh air indoors using, on average, 80% less energy than that needed for air conditioning (cooling and heating). These units are designed for use in the following applications: • Administrative buildings, Offices • Shopping Centres • Education facilities, Libraries, • Nursing homes, Community centres Healthcare facilities • Cafés, Hotels, Restaurants • Collective housing é All facilities where ventilation is required. Classic RHE model: 9 sizes, air flow from 300 to 18,000 m 3 /h. Access RHE model: 5 sizes, air flow from 350 to 8500m³/h. Classic model: 5 sizes, air flow from 300 to 6600 m 3 /h. Ground installation, horizontal position, horizontal air flow, air circuits on the sides. Vertical model: 3 sizes, air flow from 300 to 2600 m 3 /h. Ground installation, vertical position, vertical air flow, air circuits on the top. Ceiling-mounted model: 3 sizes, air flow from 300 to 1900 m 3 /h. Ceiling-mounted horizontal unit with vertical air flows and air connections on the sides. Plug & Play AHU with onboard control, Energy class A+ across the entire range, High efficiency heat recovery unit, EC fan motor assembly, high performance USE Air flow: 500 to 18 000 m 3 /h * These values are provided for guidance only and are based on a standard dual-flow unit without electric heater option. MODELS Nominal flow rate (m 3 /h) Max. power* (kW) Max current* (A) Voltage (V) 700 700 1,43 6,2 1-Ph 230 1200 1200 1,43 6,2 1600 1600 2,50 3,6 3-Ph 400 MODELS Nominal flow rate (m 3 /h) Max. power* (kW) Max current* (A) Voltage (V) 700 1000 1,43 6,2 1-Ph 230 1500 1500 2,50 3,6 3-Ph 400 2000 2000 2,50 3,6 MODELS Nominal flow rate (m 3 /h) Max. power* (kW) Max current* (A) Voltage (V) 1000 1000 1,2 5,4 1-Ph 230 2000 2000 2,5 2,9 3-Ph 400 3000 3000 4,2 6,1 5000 5000 6,1 8,8 7500 7500 7,1 10,3 MODELS Nominal flow rate (m 3 /h) Max. power* (kW) Max current* (A) Voltage (V) 1000 1000 1,43 6,2 1-Ph 230 2000 2000 2,50 3,6 3-Ph 400 3000 3000 3,82 5,5 4000 4000 4,23 6,1 5000 5000 4,23 6,1 6000 6000 6,03 8,7 7500 7500 6,03 8,7 10000 10000 12,06 17,4 15000 15000 15,45 22,3 RANGE FLOWAY Classic & Classic RHE FLOWAY Vertical FLOWAY Access RHE FLOWAY Ceiling-mounted Specifications Class Mechanical strength D2 Airtightness L2 Filter bypass leak F9 Thermal transmission T3 Thermal bridge TB2 High energy-efficiency heat recovery unit Depending on its layout, the Floway offers two different high-efficiency heat recovery systems: "CONTRA FLOW" plate heat exchanger equipped with a bypass (Classic, Vertical, Ceiling-mounted models) Rotary heat exchanger (Classic and Access RHE models) Year-round optimal heat recovery unit

Upload: others

Post on 20-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

  • 1

    FLO

    WAY

    HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 16.674 A

    Air handling unit

    The FLOWAY dual-flow air handling unit is a PLUG & PLAY ventilation unit equipped with a highly efficient heat recovery unit with plug fans and high performance EC motors, designed to meet all the requirements of recent ecodesign regulations. Unit supplied ready to use, prewired, preprogrammed in the factory and supplied with a remote control.It draws clean, fresh air indoors using, on average, 80% less energy than that needed for air conditioning (cooling and heating).These units are designed for use in the following applications:• Administrativebuildings,Offices •ShoppingCentres• Educationfacilities,Libraries, •Nursinghomes,

    Community centres Healthcare facilities• Cafés,Hotels,Restaurants •Collectivehousing

    é All facilities where ventilation is required.

    Classic RHE model: 9 sizes, air flow from 300 to 18,000 m3/h.

    Access RHE model: 5 sizes, air flow from 350 to 8500m³/h.

    Classic model: 5 sizes, air flow from 300 to 6600 m3/h. Ground installation, horizontal position, horizontal air flow, air circuits on the sides.

    Vertical model: 3 sizes, air flow from 300 to 2600 m3/h. Ground installation, vertical position, vertical air flow, air circuits on the top.

    Ceiling-mounted model: 3 sizes, air flow from 300 to 1900 m3/h. Ceiling-mounted horizontal unit with vertical air flows and air connections on the sides.

    Plug & Play AHU with onboard control, Energy class A+ across the entire range, High efficiency heat recovery unit, EC fan motor assembly, high performance

    Use

    Air flow: 500 to 18 000 m3/h

    * These values are provided for guidance only and are based on a standard dual-flow unit without electric heater option.

    MODELS Nominal flow rate (m3/h) Max. power* (kW) Max current* (A) Voltage (V)700 700 1,43 6,2 1-Ph 2301200 1200 1,43 6,2

    1600 1600 2,50 3,6 3-Ph 400

    MODELS Nominal flow rate (m3/h) Max. power* (kW) Max current* (A) Voltage (V)700 1000 1,43 6,2 1-Ph 230

    1500 1500 2,50 3,6 3-Ph 4002000 2000 2,50 3,6

    MODELS Nominal flow rate (m3/h) Max. power* (kW) Max current* (A) Voltage (V)1000 1000 1,2 5,4 1-Ph 2302000 2000 2,5 2,9

    3-Ph 4003000 3000 4,2 6,15000 5000 6,1 8,87500 7500 7,1 10,3

    MODELS Nominal flow rate (m3/h) Max. power* (kW) Max current* (A) Voltage (V)1000 1000 1,43 6,2 1-Ph 2302000 2000 2,50 3,6

    3-Ph 400

    3000 3000 3,82 5,54000 4000 4,23 6,15000 5000 4,23 6,16000 6000 6,03 8,77500 7500 6,03 8,7

    10000 10000 12,06 17,415000 15000 15,45 22,3

    RangeFLOWAY Classic & Classic RHE

    FLOWAY Vertical

    FLOWAY Access RHE

    FLOWAY Ceiling-mounted

    Specifications ClassMechanical strength D2

    Airtightness L2Filter bypass leak F9

    Thermal transmission T3Thermal bridge TB2

    High energy-efficiency heat recovery unitDepending on its layout, the Floway offers two different high-efficiency heat recovery systems:

    "CONTRA FLOW" plate heat exchangerequipped with a bypass (Classic, Vertical, Ceiling-mounted models)

    Rotary heat exchanger (Classic and Access RHE models)Year-round optimal heat recovery unit

  • 2 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 16.674 A

    Air handling unit

    FLOWAY

    Casingn Double-skin panels made from sheet steel, galvanised on both

    sides, thickness 8/10 mm. n RAL 7035 grey precoated external panels.n Class M0/A1.n Mineral wool, thickness 50 mm.

    Filtrationn M5, F7 HEE, F9 HEE filters.n Filter cells kept compressed by a special system to ensure a

    leaktight seal.n Classic, Vertical, Ceiling-mounted models: fouling value

    monitored by analogue sensor and displayed by controller.n Access model: pressure switch control on each air flow.

    Pressure switch status displayed by controller.

    Ventilationn "Plug Fan" type direct drive FMA. n Plug fan driven by an electronically commutated motor (EC

    motor, built-in variable speed control).

    Heat recovery unitsn "Contra Flow" plate heat exchanger equipped with a

    motorised bypass (Ceiling-mounted, Vertical and Classic models). é Efficiency greater than 80% across the range of air flows.

    n Rotary heat exchanger equipped with rotation speed control (Classic RHE model).é Efficiency greater than 80% at nominal flow rate.

    n Constant speed rotary heat exchanger (Access RHE model).é 80% efficiency at nominal flow rate.

    Hydraulic coiln Copper pipes, aluminium fins.n Coil can be integrated or additional (cased).n With the accessory fitted, 2- or 3-way control valve and

    0-10 V actuator controlled by FLOWAY Control for setpoint accuracy.

    n Stainless steel condensate drain pan (cooling coil or mixed coil only).

    Electrics box

    n Electrics box for power, control and internal regulation of the unit, comprising as standard:

    - Power supply (3-Ph/400 V/Earth or 1-Ph/230 V/Earth).- Main disconnect switch.- Protected transformer.- Protection and control of all electrical components by a

    circuit breaker and contact switch.- Peripheral options and power terminal block.- Factory-programmed PLC control.- Hand-held cabled micro-terminal.- Fault summary contact.- 3 temperature sensors.- 4 pressure sensors (2 pressure sensors and 2 pressure

    switches on the Access model).

    AccessoriesDamper formed of airfoil blades, powered by a servomotorOn/off with return spring.Flexible sleeve.Adjustable feet.CO2 air quality sensor.Roof.Canopy.Mixing section.Indoor environment switch.ModBus RTU, LON, KNX, ModBus communicationTCP, Bacnet IP, web interface.

    DescRiption

    Electric heatersn High-limit safety thermostat with automatic and manual reset.n Control by 2-stage on/off operation fully controlled by FLOWAY

    Control.

    MODELS & SIZES Power (kW) Current (A) Voltage (V)

    Classic & Classic RHE 1000 Vertical 700

    Ceiling-mounted 700 & 12004,5 20 1-Ph 230

    Vertical 1500 (additional casing)Ceiling-mounted 1600 (additional casing) 7,20 11

    3-Ph 400

    Vertical 1500 8,1 12Classic & Classic RHE 2000 10,8 16Classic & Classic RHE 3000 12,6 19Classic & Classic RHE 4000 16,8 25

    Classic RHE 5000 19,8 29Classic & Classic RHE 6000 22,8 34

    Classic RHE 7500 31,2 46Classic RHE 10000 N/A N/AClassic RHE 15000 N/A N/A

  • 3

    FLO

    WAY

    HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 16.674 A

    Air handling unit

    FLOWAY Control function (software V2.2) Included Options*

    Fan time schedule Built-in timer: management in series 4 events per year, per week and per day X

    Safety

    Frost protectionBy fresh air temperature control XBy exhaust air flow pressure on heat recovery unit delta control (pressure sensor) X

    Monitoring of sensor status XMonitoring operation values (thresholds) XOperating control of EC fan motor assemblies XFilter fouling control (via analogue sensor or pressure switch, depending on the model) X

    Fault summary XFire monitoring (potential free (dry) contact available (normally closed)) X

    Alarms Management of alarms and log (100) X

    Control mode

    Control of return air or supply air temperature X

    Regulated temperature control based on outdoor temperature X

    Control of room temperature with a room terminal X

    Hot air and/or cold air production

    Gradual action on the 2- or 3-way control valve on the hydraulic coil XGradual action on the electric heater TRIAC XOn/Off action on the various stages of the electric heater X

    Free coolingRotary heat exchanger shut down (Classic and Access RHE models) XOpen bypass on contra-flow plate recovery unit (Vertical, Ceiling-mounted & Classic models) X

    Night cooling functionRotary heat exchanger shut down (Classic and Access RHE models) XOpen bypass on contra-flow plate recovery unit (Vertical, Ceiling-mounted & Classic models) X

    Morning heating function Opening level control of mixing bypass (CLASSIC RHE model) X

    Eco-recycling function Opening level control of mixing bypass (CLASSIC RHE model) X

    Efficiency optimisation Variation of the rotation speed of the rotary recovery unit (CLASSIC RHE model) X

    Configuration of the air flow rate

    2 air flow rate setpoints per air flow XDisplay of the air flow rate X

    Constant flow rate oper-ation Keeps the air flow rate constant regardless of how fouled the filters are X

    Modulation of flow rates operation

    Single zoneSignal 0-10V CO2 sensor X

    ContactPresence contact XExternal contact X

    Multi zone Air supply duct constant pressure operation X

    Communicating mode Management by CMS

    ModBus RS485 protocol XLON protocol XKNX protocol XModBus TCP/BACNET IP protocol XWeb interface

    Miscellaneous

    Languages supported (French/English/German/Dutch/Spanish/Italian) XIntegrated temperature sensors (*3: fresh air supply and extraction, exhaust air extraction) XIntegrated pressure checks (*4: fresh air and exhaust air filter fouling level, fresh air and exhaust air fan) X

    Damper control XInformation provided to the user via the hand-held micro terminal XContact for controlling the pumps for the hydraulic coils (with operating control)** XContact for controlling an external outdoor heat production system (boiler, etc.)** XContact for controlling a humidifier** XElectric heater load shedding input** X

    contRolFLOWAY ControlFLOWAY features, as standard, an electrics box equipped with a factory-programmed PLC and a hand-held micro-terminal.

    Option*: Requires the component to be selected as an option: damper, coil, CO2 sensor, etc.** Except Access RHE model

  • 4 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 16.674 A

    Air handling unit

    FLOWAYaiR flow Dimensions anD oRientation

    Air FLOW OriEntAtiOnAccess and Classic rHE models

    Classic models

    FLOWAY CLAssiC, CLAssiC rHE, ACCEss rHE

    SIZES

    FLOWAY Classic, Classic RHE, Access RHE

    Height (C)(mm)

    Width (B)(mm)

    Length (A) (mm) Weight (kg)*

    Classic Classic RHEAccess

    RHE ClassicClassic

    RHE Access RHE

    1000 958 810 1580** 1266** 1266 200 201 1802000 1158 1010 1150 + 800** 510 + 800** 1310 350 309 2503000 1359 1210 1264 + 800 800 + 800 1600 465 432 3304000 1659 1510 1264 + 800 800 + 800 - 580 558 -5000 1659 1510 - 800 + 800 1600 - 604 4456000 1959 1810 1407 + 800 800 + 800 - 765 702 -7500 1959 1810 - 800 + 800 1600 - 751 580

    10000 2090 1920 - 1100 + 1100 - - 955 -15000 2340 2192 - 1100 + 1200 - - 1250 -

    AD

    B

    E

    C

    WHITE ARROW = FRESH AIR

    BLACK ARROW = EXTRACTED AIR

    * Without internal option.** Circular coupling; protrudes 47 mm on either side.

    rOts 2.1

    PLAs01

    rOts 2.2

    PLAs02

  • 5

    FLO

    WAY

    HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 16.674 A

    Air handling unit

    FLOWAY Vertical

    Ø 16 mm condensate drain pipe.

    MODELS Dimensions Weight (kg)* Height Length Width

    700 1385 1313 730 2021500 1758 1593 832 3302000 1901 1735 832 389

    size 1000

    * Without internal option

    size 1500

    n

    n

    n

    n

    n

    WHITE ARROW = FRESH AIR

    BLACK ARROW = EXHAUST AIR

    size 2000

    n

    n

    n

    n

    n

    WHITE ARROW = FRESH AIR

    BLACK ARROW = EXHAUST AIR

    1313

    1550

    1735

    730

    805

    832

    805

    492.5

    572

    620 824 248

    584.5

    730

    193

    248

    702

    832

    124

    124

    124

    250

    355 355

    355

    355

    355

    355

    355

    355

    250

    250 250

    584.5

    730

    824

    193

    248

    248

    492.5

    572

    620

    46

    46

    46

    4747

    47

    100

    100

    100

    272

    349

    385

    231

    253

    253

    253

    295

    295

    253

    239

    231

    7070

    70

    1385

    1758

    1901

    1711

    1854

    1754

    1611

    1338

    1238

    1270

    1593

    1692

  • 6 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 16.674 A

    Air handling unit

    FLOWAY

    Ø 16 mm condensate drain pipe.

    size 1200

    FLOWAY Ceiling-mounted

    MODELS Dimensions Weight (kg)Height Length Width

    700 585 1453 896 161 1200 585 1592 1174 2061600 585 1850 1456 279

    size 700

    WHITE ARROW = FRESH AIR

    BLACK ARROW = EXTRACTED AIR

    n

    WHITE ARROW = FRESH AIR

    BLACK ARROW = EXTRACTED AIR

    size 1600

    n

    n

    MODELSAir flow dimensions (MM)

    A B C D

    700 306 306 Ø160 Ø315

    1200 398 398 Ø250 Ø355

    1600 499.5 499.5 Ø250 Ø400

    WHITE ARROW = FRESH AIR

    BLACK ARROW = EXTRACTED AIR

    13.5

    13.5

    13.5

    924

    1202

    1484

    1456

    1506

    253

    896

    1174

    946

    1224

    280

    280

    280

    4745

    280

    47 1762

    1856

    280

    280

    47

    47 47

    47

    471359

    1498

    1592

    1453

    799

    938

    601

    A

    C C

    D16

    71

    B

    601

  • 7

    FLO

    WAY

    HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 16.674 A

    Air handling unit

    405 405

    221

    321

    810

    505 505

    1010

    271

    371

    1210

    759

    1069

    1810

    Additional casing (MUST ONLY BE POSITIONED IN A HORIZONTAL AIR FLOW)

    size 1

    size 3

    size 5

    size 2

    size 4

    FLOWAY MODELS Additional casing sizes (mm) Weight (kg)

    Classic RHE, Classic 1000Vertical 700Ceiling-mounted 700

    Size1542 x 496 x 810 49 kg

    Classic RHE, Classic 2000Vertical 1500 & 2000Ceiling-mounted 1200 & 1600

    Size 2 642 x 496 x 1010 62 kg

    Classic RHE & Classic 3000 Size 3 759 x 400 x 1210 68 kg

    Classic RHE & Classic 4000 & 5000 Size 4 909 x 400 x 1510 88 kg

    Classic RHE & Classic 6000 & 7500 Size 5 1059 x 400 x 1810 112 kg

    1510

    906793

  • 8 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 16.674 A

    Air handling unit

    FLOWAYclassic RHe moDel peRfoRmance

    sfpv aHU = f (flow Rate)

    Heat RecoveRy Unit efficiency = f (flow Rate)

    opeRating pRessURe = f(flow)

    200 Pa

    400 Pa

    800 Pa

    500 m3/h 2500 m3/h 4500 m3/h 6500 m3/h 8500 m3/h 10500 m3/h 12500 m3/h 14500 m3/h 16500 m3/h

    1000 2000

    3000

    4000

    5000

    6000

    7500 10000

    15000

    70,0%

    80,0%

    90,0%

    500 m3/h 2500 m3/h 4500 m3/h 6500 m3/h 8500 m3/h 10500 m3/h 12500 m3/h 14500 m3/h 16500 m3/h

    1000 2000 3000

    4000

    5000

    6000

    7500

    1000015000

    0,30W/(m3/h)

    0,40W/(m3/h)

    0,50W/(m3/h)

    0,60W/(m3/h)

    500 m3/h 2500 m3/h 4500 m3/h 6500 m3/h 8500 m3/h 10500 m3/h 12500 m3/h 14500 m3/h 16500 m3/h

    10002000

    3000

    4000

    5000

    6000

    7500

    10000

    15000

    SFPv = 0.6 W/(m3/h)RT reference output

    Efficiency

    SFPv

    Pressure

    Flow rate

    Flow rate

    Flow rate

    F5 exhaust filter, F7 intake filter, duct pressure: 200 Pa, heat recovery unit conditions: 0°C/90% - 20°C/50%

  • 9

    FLO

    WAY

    HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 16.674 A

    Air handling unit

    access RHe moDel peRfoRmance

    20001500700

    2500 m3/h2000 m3/h1500 m3/h1000 m3/h500 m3/h75,0%

    85,0%

    70.00%

    72.00%

    74.00%

    76.00%

    78.00%

    80.00%

    82.00%

    84.00%

    86.00%

    88.00%

    90.00%

    500 1500 2500 3500 4500 5500 6500 7500 8500

    1000

    2000

    3000

    50007500

    20001500

    700

    2500 m3/h2000 m3/h1500 m3/h1000 m3/h500 m3/h0,30W/(m3/h)

    0,40W/(m3/h)

    0,50W/(m3/h)

    0,60W/(m3/h)

    0.2

    0.25

    0.3

    0.35

    0.4

    0.45

    0.5

    0.55

    0.6

    500 1500 2500 3500 4500 5500 6500 7500 8500

    1000

    2000

    3000 5000

    7500

    2000

    1500

    700

    1000

    2000 3000

    500

    7500

    2500 m3/h2000 m3/h1500 m3/h1000 m3/h500 m3/h400 Pa

    800 Pa

    200

    300

    400

    500

    600

    700

    800

    900

    1000

    1100

    500 1500 2500 3500 4500 5500 6500 7500 8500

    Efficiency

    SFPv W/(m3/h)

    Pressure Pa

    Flow rate (m3/h)

    Flow rate (m3/h)

    Flow rate (m3/h)

    SFPv = 0.6 W/(m3/h)RT reference output

    sfpv aHU = f (flow Rate)

    Heat RecoveRy Unit efficiency = f (flow Rate)

    opeRating pRessURe = f(flow)F5 exhaust filter, F7 intake filter, duct pressure: 200 Pa, heat recovery unit conditions: 0°C/90% - 20°C/50%

  • 10 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 16.674 A

    Air handling unit

    FLOWAYclassic moDel peRfoRmance

    sfpv aHU = f (flow Rate)

    opeRating pRessURe = f(flow)

    200 Pa

    400 Pa

    800 Pa

    500 m3/h 1500 m3/h 2500 m3/h 3500 m3/h 4000 m3/h 5500 m3/h 6500 m3/h

    2000

    1000

    3000

    4000

    6000

    75,0%

    85,0%

    500 m3/h 1500 m3/h 2500 m3/h 3500 m3/h 4500 m3/h 5500 m3/h 6500 m3/h

    1000 2000 3000 40006000

    0,30W/(m3/h)

    0,40W/(m3/h)

    0,50W/(m3/h)

    0,60W/(m3/h)

    500 m3/h 1500 m3/h 2500 m3/h 3500 m3/h 4500 m3/h 5500 m3/h 6500 m3/h

    1000

    20003000 4000 6000

    SFPv=0.6 W/(m3/h)RT reference output

    Efficiency

    SFPv

    Pressure

    Flow rate

    Flow rate

    Flow rate

    Heat RecoveRy Unit efficiency = f (flow Rate)

    F5 exhaust filter, F7 intake filter, duct pressure: 200 Pa, heat recovery unit conditions: 0°C/90% - 20°C/50%

  • 11

    FLO

    WAY

    HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 16.674 A

    Air handling unit

    veRtical moDel peRfoRmance

    20001500700

    2500 m3/h2000 m3/h1500 m3/h1000 m3/h500 m3/h75,0%

    85,0%

    20001500

    700

    2500 m3/h2000 m3/h1500 m3/h1000 m3/h500 m3/h0,30W/(m3/h)

    0,40W/(m3/h)

    0,50W/(m3/h)

    0,60W/(m3/h)

    2000

    1500

    700

    2500 m3/h2000 m3/h1500 m3/h1000 m3/h500 m3/h400 Pa

    800 Pa

    Efficiency

    SFPv

    Pressure

    Flow rate

    Flow rate

    Flow rate

    SFPv = 0.6 W/(m3/h)RT reference output

    sfpv aHU = f (flow Rate)

    Heat RecoveRy Unit efficiency = f (flow Rate)

    opeRating pRessURe = f(flow)F5 exhaust filter, F7 intake filter, duct pressure: 200 Pa, heat recovery unit conditions: 0°C/90% - 20°C/50%

  • 12 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 16.674 A

    Air handling unit

    FLOWAYceiling-moUnteD moDel peRfoRmance

    sfpv aHU = f (flow Rate)

    0,30W/(m3/h)

    0,40W/(m3/h)

    0,50W/(m3/h)

    0,60W/(m3/h)

    700 1200

    1600

    500 m3/h 700 m3/h 900 m3/h 1100 m3/h 1300 m3/h 1500 m3/h 1700 m3/h 1900 m3/h

    Heat RecoveRy Unit efficiency = f (flow Rate)

    opeRating pRessURe = f(flow)

    400 Pa

    800 Pa

    700

    1200

    1600

    500 m3/h 700 m3/h 900 m3/h 1100 m3/h 1300 m3/h 1500 m3/h 1700 m3/h 1900 m3/h

    75,0 %

    85,0 %

    700

    12001600

    500 m3/h 700 m3/h 900 m3/h 1100 m3/h 1300 m3/h 1500 m3/h 1700 m3/h 1900 m3/h

    Efficiency

    SFPv

    Pressure

    Flow rate

    Flow rate

    Flow rate

    SFPv = 0.6 W/(m3/h)RT reference output

    F5 exhaust filter, F7 intake filter, duct pressure: 200 Pa, heat recovery unit conditions: 0°C/90% - 20°C/50%

  • This document is not legally binding. As part of its continuous drive to improve its equipment, CIAT reserves the right to make any technical modifications without prior notice.