air operated valve calibration nmv21 1. 2 terminal objective given the necessary references, tools...
TRANSCRIPT
![Page 1: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/1.jpg)
Air Operated Valve CalibrationNMV21
1
![Page 2: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/2.jpg)
2
Terminal Objective
Given the necessary references, tools and test equipment, the technician will maintain pneumatic control valve components. Mastery will be demonstrated by completion of all Laboratory Practical Evaluations and scoring at least 80 % on an end of course exam.
![Page 3: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/3.jpg)
3
Enabling Objectives
Given an example or illustration, identify the types of control valves.
Given an example or illustration, identify components associated with various valve types.
Identify flow characteristics of various valves .
Describe the operation of Pneumatic Actuators.
Describe the critical elements associated with valve packing.
Describe the operation of a flapper/nozzle detector.
Describe the operation of a booster relay.
![Page 4: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/4.jpg)
4
Enabling Objectives
Describe the operation of air regulators.
Describe the operation of valve position indication devices.
Describe the use and operation of solenoid valves on air operated valves.
Calibrate a Fisher 546 I/P Converter.
Benchset diaphragm actuators.
Calibrate Valve Positioners.
Calibrate a Steam Bypass Control Valve.
![Page 5: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/5.jpg)
5
Typical Globe Valves
FLOW
![Page 6: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/6.jpg)
6
Typical Gate Valves
![Page 7: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/7.jpg)
7
Typical Butterfly Valves
FLOW
![Page 8: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/8.jpg)
8
Typical Check Valves
FLOW
FLOW
SPRING
![Page 9: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/9.jpg)
9
Typical Diaphragm Valve
![Page 10: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/10.jpg)
10
Typical Ball Valve
![Page 11: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/11.jpg)
11
Typical Plug Valves
![Page 12: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/12.jpg)
12
Typical Globe Valve ConstructionValve Body
Two Way Three Way
Bonnet
Packing Flange
Packing
Valve Stem
Valve Plug
Seat
Cage
![Page 13: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/13.jpg)
13Some Globe Valve Plugs (discs)
Various plugs shown in
yellow
Guided Disc
Basic Plug Disc
Composition Disc
![Page 14: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/14.jpg)
14
Globe Valve Ports and Action
Reverse Action(down to open)
FLOW
Double-Ported Globe Valve
FLOW
![Page 15: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/15.jpg)
15
Typical Gate Valve Construction
Valve Body
Bonnet
Packing Flange
PackingValve Stem
Split Disc Solid Disc
Valve Seat
![Page 16: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/16.jpg)
16
Typical Butterfly Valve Construction
Valve Body
Packing Flange
Valve Stem
Valve Disc
Valve Seat
Bearings
Packing
Packing
![Page 17: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/17.jpg)
17
Typical Ball Valve Construction
Valve Body
Packing Flange
Packing
Valve Stem
Ball
Valve Seat
Bearings
Bonnet
![Page 18: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/18.jpg)
18% Valve Travel
% F
low
0
100
100
50
50
75
75
25
25
Linea
r
Qui
ck O
peni
ng
Equa
l Per
cent
age
Ideal FlowCharacteristics
![Page 19: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/19.jpg)
19
Plug and Seat Flow Characterization
Linear Equal Percentage
Quick Opening
![Page 20: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/20.jpg)
20
Trim Cage Flow Characterization
![Page 21: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/21.jpg)
21
Drag Valve Trim
![Page 22: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/22.jpg)
22
Diaphragm Actuator Construction
Diaphragm Casings
Diaphragm
Diaphragm Plate
Actuator Spring
Actuator Stem
Spring Seat
Spring Adjustor
Stem Connector
Travel Indicator Disk
Indicator Scale
Yoke
Seal Bushing
![Page 23: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/23.jpg)
23
O-RingPositioner
Piston Rod Extension
Piston Rod Boot
Cylinder
Piston / Rod
Lower Seal Bushing
Upper Seal Bushing
Yoke
![Page 24: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/24.jpg)
24
![Page 25: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/25.jpg)
25
Braided Ring
Braided Ring
Graphite Rings
CarbonSpacer
PackingGlandFollower
Va
lve
Ste
m
![Page 26: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/26.jpg)
26
![Page 27: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/27.jpg)
27
Fisher 3582 Positioner
Principle of Operation
![Page 28: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/28.jpg)
28
Fisher 3582Positioner
Construction
Travel Adjustment ScrewInput
Cam Beam
Pivot Pin
Flapper
Follower Assembl
y
Nozzle
Input Bellows
Rotary Shaft Arm
Nozzle
![Page 29: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/29.jpg)
29
Cam
Guide & Roller BearingBeam
Fisher 3582 Wear Points
Beam Off Center
Cam
Guide Wear
Roller Wear and Cut
Wear caused by Guide (“locked valve position”)
Wear caused by siezed roller
![Page 30: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/30.jpg)
30
Fisher 3570PositionerPrinciple of Operation
![Page 31: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/31.jpg)
31
3570 Positioner
Construction
Air Supply
Cylinder (Top)
Cylinder (bottom)Input
Bias Spring
Range Spring
Horizontal Relay
Vertical Relay
Input Bellows
Bellows Post
Beam
![Page 32: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/32.jpg)
32
![Page 33: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/33.jpg)
33
![Page 34: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/34.jpg)
34
NAMCO Position Switches
Operating Lever
Clamping Screw
Lever Locking Pipe PlugContacts
Cover / Gasket
![Page 35: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/35.jpg)
35
Simplified LVDT
PositionSignals
Excitation
![Page 36: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/36.jpg)
36
P&ID symbols for SOV’s
S
S
S
S
S
S
De-Energized Energized
2-Way
3-Way
4-Way
![Page 37: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/37.jpg)
37
Typical SOV Construction
Coil
Cover
Yoke
Housing
Solenoid Base
Core Assembly
Body
Disc Assembly
End Cap
![Page 38: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/38.jpg)
38
Fisher 546 I/P
![Page 39: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/39.jpg)
39Fisher 546 I/P Construction
Air SupplyOutp
ut
Input
Zero
Span
Torque Motor
AssemblyShunt Pivot(behind Torque
Motor)
![Page 40: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/40.jpg)
40
FO
FO
FC
FC
FC
FC
S
S
![Page 41: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/41.jpg)
41
FO
FO
FC
FC
FC
FC
S
S
S
![Page 42: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/42.jpg)
42
FO
FO
FC
FC
FC
FC
S
S
S
![Page 43: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/43.jpg)
43
![Page 44: Air Operated Valve Calibration NMV21 1. 2 Terminal Objective Given the necessary references, tools and test equipment, the technician will maintain pneumatic](https://reader036.vdocument.in/reader036/viewer/2022062407/56649d9f5503460f94a89b66/html5/thumbnails/44.jpg)