AIRSIDE DESIGN AIRSIDE DESIGN © Copyright 2008 HVAC Design Solutions 1 Essential Design Programs with Accurate Sizing Calculations help to “Streamline Your Design” H H VAC VAC D D ESIGN ESIGN S S OLUTIONS OLUTIONS ENGINEERING SOFTWARE ENGINEERING SOFTWARE

Upload: lester-harrington

Post on 17-Dec-2015

218 views

Category:

Documents


0 download

TRANSCRIPT

AIRSIDE DESIGNAIRSIDE DESIGN

© Copyright 2008 HVAC Design Solutions 1

Essential Design Programs with Accurate Sizing Calculations help to “Streamline Your Design”

Essential Design Programs with Accurate Sizing Calculations help to “Streamline Your Design”

HHVAC VAC DDESIGN ESIGN SSOLUTIONSOLUTIONS ENGINEERING SOFTWAREENGINEERING SOFTWARE

“Airside Design” from HVAC Design Solutions is a package of software programs for many of the HVAC Designer’s sizing tasks:

Duct System Sizing -“Enhanced” Equal Friction Duct System Sizing -“Simplified” Static Regain Supply Fan Static Pressure Calcs Return/Exhaust Fan Static Pressure Calcs Duct Fitting Coefficients - Built-in Coil Psychrometrics, Preliminary Acoustics Extensive Help Files, and “Extras”

© Copyright 2008 HVAC Design Solutions 2

OverviewOverview

Reduce your dependence on Reference Books, Charts, Graphs, and “Rules of Thumb”.

Eliminate many of the usual HVAC Design Tasks

Reduce common errors and mistakes Create an easy-to-follow, step-by-

step “Procedure for Airside Design” for all projects.

© Copyright 2008 HVAC Design Solutions 3

““Streamline Your Design”Streamline Your Design”

Software Package contains most of the sizing calculations and procedures for typical projects

© Copyright 2008 HVAC Design Solutions 4

Extensive Calculation ProgramsExtensive Calculation ProgramsJUMP TO FILE

PROJECT INFORMATION

AIR SIDE DESIGN

C:\calcs1\air\INDEX1F.xls - INDEX!C10

C:\calcs1\air\INDEX1F.xls - 'SUP. FAN SP'!F14

C:\calcs1\air\INDEX1F.xls - 'RET-EXH FAN SP'!F14

C:\calcs1\air\INDEX1.xls - 'AHU-COOL. COIL'!H6

C:\calcs1\air\INDEX1.xls - 'AHU-HTG.COIL'!H6

C:\calcs1\air\INDEX1.xls - AIRBAL!A10

C:\calcs1\air\INDEX1.xls - 'SUPPLY-DUCT'!A19

C:\calcs1\air\INDEX1.xls - 'RET-EXH-DUCT'!A19

C:\calcs1\air\INDEX1.xls - 'STAT.REGAIN-DUCT'!A13

C:\calcs1\air\INDEX1.xls - 'SHEETMETAL-WT.'!B12

C:\calcs1\air\LOADCAL.XLS - 'Takeoff - Energy'!A12

C:\calcs1\air\INDEX1.xls - INDEX!C10

C:\calcs1\air\INDEX1.xls - DUCTCALC!B21

C:\calcs1\air\Bldginfo.xls - 'Ceiling Space'!A1

C:\calcs1\air\LOADCAL.XLS - 'Design Criteria'!C5

C:\calcs1\air\LOADCAL.XLS - 'Takeoff - Trace'!A12

C:\calcs1\air\LOADCAL.XLS - 'Takeoff - HAP'!A12

C:\calcs1\air\INDEXP.xls - INDEX!C10

C:\calcs1\air\INDEXP.xls - PROJ.INFO!D2

../..\calcs1\air\Bldginfo.xls - 'Bldg. Info.'!A1

C:\calcs1\air\Bldginfo.xls - 'Bldg. Info. 2'!A1

AIR HANDLING UNIT - PRELIM. COOLING COIL CALCS

AIR HANDLING UNIT - PRELIM. HEATING COIL CALCS

LOAD CALC. TAKE-OFF FORM #2

AIR BALANCE TABULATION

SUPPLY FAN EXT. STATIC PRESSURE CALC. - FINAL

RETURN/EXHAUST FAN EXT. STATIC PRESS. CALC. - FINAL

C:\calcs1\air\INDEX1.xls - EXTSPFAN!C3

C:\calcs1\air\INDEX1.xls - 'VAV REHEAT'!C6

FAN PRESSURE DROP CALCS

DUCT SIZING - TO AVOID OBSTRUCTIONS - SINGLE DUCT

SUPPLY DUCT SIZING SCHEDULE - DUCT SYSTEM

RETURN/EXH. DUCT SIZING SCHEDULE - DUCT SYSTEM

SIMPLIFIED STATIC REGAIN DUCT SIZING SCHEDULE

SHEET METAL WEIGHT AND INSULATION CALCS

FAN STATIC PRESSURE CALCS - PRELIMINARY

VAV - REHEAT COIL LOAD CALCULATIONS

ENERGY CALCULATIONS TAKE-OFF FORM

CONTENTS

BASIC PROJECT INPUT SHEET

BUILDING INFORMATION REQUEST LETTER #1

BUILDING INFORMATION REQUEST LETTER #2

CEILING SPACE INFORMATION REQUEST FORM

HEAT/COOL LOAD DESIGN CRITERIA

LOAD CALC. TAKE-OFF FORM #1

“Any One of these programs is worth the cost of the Entire Package!”

Quick Links to all calculation programs

© Copyright 2008 HVAC Design Solutions 5

HELP

BASIC PROJECT INFORMATION

PROJECT NAME :

PROJECT NUMBER :

PROJECT LOCATION :

DATE :

TYPE OF BUILDING :

SUMMER OUTDOOR DESIGN DRY BULB TEMP. (DEG. F):

WINTER OUTDOOR DESIGN DRY BULB TEMP. (DEG. F):

INDOOR DESIGN TEMP. - SUMMER (DEG. F) :

INDOOR DESIGN TEMP. - WINTER (DEG. F) :

PROJECT ELEVATION (FEET) :

PROJECT MANAGER :

PROJECT ENGINEER :

CLIENT :

CLIENT CONTACT NAME:

75.0

-6.0

OAKPARK OFFICE BLDG. 3

134-08

CHICAGO, IL

05/06/08

JOHN GOREMANN

"YOUR COMPANY NAME"

OFFICE

91.0

ADS ARCHITECTS

70.0

670

BILL REECE

JIM EDMOND

Begin with Basic Project Information input

Typical Project StartupTypical Project Startup

Information automatically transfers to all programs

Design Conditions are used in many calculations

© Copyright 2008 HVAC Design Solutions 6

Duct System Sizing - Equal FrictionDuct System Sizing - Equal Friction

PROJECT NAME:PROJECT NUMBER:DATE:

6

8

FROM TO

1 2 9500 24 0.08 84x14 1507 0.070 34 32x30 34x302 3 8750 28 0.08 60x18 1388 0.060 34 32x30 34x303 4 8000 28 0.08 50x18 1432 0.069 32 30x28 34x264 5 6500 28 0.08 44x18 1324 0.064 30 28x28 30x265 6 5500 24 0.08 52x14 1286 0.066 28 26x26 28x246 7 4250 24 0.08 44x14 1153 0.060 26 24x24 26x227 8 3000 28 0.08 24x18 1136 0.072 22 20x20 24x188 9 2000 28 0.08 20x18 917 0.054 20 20x18 22x169 10 750 28 0.08 14 702 0.052 14 14x12 18x10

SUPPLY DUCT SIZING - TO AVOID OBSTRUCTIONS (ENHANCED EQUAL FRICTION)

NOTE: IF BEAM IS FIREPROOFED, DEDUCT THICKNESS OF FIREPROOFING FROM CLEARANCE.

TEST PROJECT #11. DUCT SIZES ARE BASED ON ALLOWANCE OF 2" THICK INSULATION (TOTAL 4"),

ALTERNATE PRESS. DROP

(IN./100 FT.)

0.05

YELLOW : ASPECT RATIO EXCEEDS 5:1 - NOT RECOMMENDED (MORE EXPENSIVE)

RED : ASPECT RATIO EXCEEDS 7:1 - NOT RECOMMENDED (NEED MORE SPACE BELOW BEAMS)

670

2. SPACE BELOW BEAMS IS MEASURED FROM BOTTOM OF BEAM, OR OTHER OBSTRUCTION,

ELEVATION:

DUCT SECTION FLOW RATE (CFM)

SPACE BELOW BEAMS

(INCHES)

DESIGN PRESSURE

DROP (IN./100 FT.)

ALTERNATE SIZES (MAY NOT FIT UNDER BEAMS)

ROUND (INCHES)

RECT. 2 (W x D)

RECT. 3 (W x D)

TYPE OF DUCT

0.08

DESIGN PRESS. DROP

(IN./100 FT.)

DUCT SIZE (DIAM.) OR (W x D)

VELOCITY (FPM)

CALCULATED PRESSURE

DROP (IN./100 FT.)

1456-0706/21/07

AND 6" CLEARANCE FOR LIGHTS. SIZE SHOWN IS "INSIDE CLEAR" DUCT SIZE.

TO THE CEILING - CEILING CONSTRUCTION INCLUDED IN 6" ALLOWANCE FOR LIGHTS.

BEAM

SPACE BELOW BEAM

FLOOR (OR ROOF)

6" FOR LIGHTSCEILING

SUPPLYPRINT

RESET/CLEAR

Duct Sizing - “To Avoid Obstructions” Helps reduce Change Orders!

Alternate sizes available for “between beam” sizes, if desired

Quick and Easy Input

Most “Economical” Duct Sizes to fit the Available Space

© Copyright 2008 HVAC Design Solutions 7

Duct System Sizing - Static RegainDuct System Sizing - Static Regain

6

8

FROM TO

FAN 1 25000 36 150 94x26 1750 2

1 2 20000 36 120 100x26 1300 1

2 3 15500 36 50 100x26 1000 2

3 4 10250 30 25 108x20 850 2

4 5 7500 30 60 94x20 700 1

5 6 2000 30 125 30x20 500 3

DUCT SIZE (DIAM.) OR (W x D)

VELOCITY OF

SECTION (FPM)

ROUND 90 DEG. ELBOW

ROUND 45 DEG. ELBOW

ROUND 90 DEG.

CONICAL TEE

(FLOW TURNS)

ROUND 45 DEG.

CONICAL TEE

(FLOW TURNS)

NUMBER OF EACH TYPE OF FITTING IN THE ASSOCIATED DUCT SECTION

RECT. 90 DEG.

ELBOW (SINGLE VANES)

RECT. 90 DEG.

ELBOW (DOUBLE VANES)

RECT. 45 DEG.

ELBOW (NO

VANES)

PROJECT NAME:PROJECT NUMBER:

DUCT SECTION FLOW RATE (CFM)

SPACE BELOW BEAMS

(INCHES)

MEASURED LENGTH OF

SECTION (FEET)

DATE:

ELEVATION:

1. DUCT SIZES ARE BASED ON ALLOWANCE OF 2" THICK INSULATION (TOTAL 4"), AND 6" CLEARANCE FOR LIGHTS. SIZE SHOWN IS "INSIDE CLEAR" DUCT SIZE.2. SPACE BELOW BEAMS IS MEASURED FROM BOTTOM OF BEAM, OR OTHER OBSTRUCTION,

NOTE: IF BEAM IS FIREPROOFED, DEDUCT THICKNESS OF FIREPROOFING FROM SPACE BELOW BEAMS.

TO THE CEILING - CEILING CONSTRUCTION INCLUDED IN 6" ALLOWANCE FOR LIGHTS.

YELLOW : ASPECT RATIO EXCEEDS 5:1 - NOT RECOMMENDED (MORE EXPENSIVE - NEED MORE SPACE BELOW BEAMS)

RED : ASPECT RATIO EXCEEDS 7:1 - NOT RECOMMENDED (NEED MORE SPACE BELOW BEAMS)

INITIAL VELOCITY

OF 1st DUCT SECTION FROM FAN

(FPM)

1750

SUPPLY DUCT SIZING - TO AVOID OBSTRUCTIONS (SIMPLIFIED STATIC REGAIN)

BEAM

SPACE BELOW BEAM

FLOOR (OR ROOF)

6" FOR LIGHTSCEILING

PRINT

RESET/CLEAR

Static Regain Sizing improves system balancing and can reduce costs

Quick and Easy Input

Static Regain Sizing - But, Greatly Simplified!

© Copyright 2008 HVAC Design Solutions 8

Fan Static Pressure Calcs - #1Fan Static Pressure Calcs - #1

© 2007 hvacdesignsolutions.com

FAN OR AHU

VAV BOX

RECT. 90 DEG. ELBOW (DOUBLE VANES)

THRU TEE - FLOW STRAIGHT (45 DEG. TAP)

BRANCH TEE - FLOW TURNS (CONICAL TAP)

A2

FAN STATIC PRESSURE CALCS DIAGRAM

SOUND TRAP

FIRE/SMOKE DAMPER

DIFFUSER - MODULAR PERF. FACE (500 CFM)

5 PIECE ELBOW

BUTTERFLY DAMPER

BRANCH TEE - FLOW STRAIGHT (CONICAL TAKEOFF)

(800 CFM)

(500 CFM)

(500 CFM)

(500 CFM)

(500 CFM)

(500 CFM)

(1000 CFM)(1000 CFM)

(1200 CFM)

(2200 CFM)

(3000 CFM)

(1500 CFM)

(4500 CFM)(6500 CFM)

(2000 CFM)

(6500 CFM)

(6500 CFM)(6500 CFM)A1

L1

H1

B1

B2A3

B3

E1

J1

F1

K1

D1

M1P1

G1

J2

E2

TRANSITIONC1

C2

C3

hvacdesignsolutions.comc

(2200 CFM)

N2

N1

Typical Project Example for Fan Static Pressure Calcs

© Copyright 2008 HVAC Design Solutions 9

Fan Static Pressure Calcs - #2Fan Static Pressure Calcs - #2SUPPLY FAN EXTERNAL STATIC PRESSURE CALCS HELP PAGE 1

PROJECT ELEVATION = 670 PROJECT NAME:SUPPLY DUCT SIZING (RECOMMENDED) PROJECT NUMBER:

(IN. H2O/100 FT.) DATE:

4.06AIR FITTING VELOCITY FITTING

FITTING QUANTITY COEFF. PRESSURE LOSSELBOW 1 - SINGLE THICKNESS QUANTITY (CFM) (C) (Vp) (IN.)TURNING VANES 0 0 0 0 0.000

0 0 0 0 0.0000 0 0 0 0.0000 0 0 0 0.0000 0 0 0 0.0000 0 0 0 0.000

ELBOW 2 - DOUBLE THICKNESS 0.000TURNING VANES 2 6500 0.53 0.12 0.127

1 3000 0.53 0.08 0.0420 0 0 0 0.0000 0 0 0 0.0000 0 0 0 0.0000 0 0 0 0.000

ELBOW 3 - 45 DEGREE WITHOUT 0.170

TEST PROJECT #11456-07

06/21/07

APPROX. FAN BHP:(CALCULATED DURING INPUT)

Qc

Qc

0.08

RESET/CLEAR

Easy Input of System Components and Air Quantities

Running Total of Approx. Fan BHP

Totalized PD for Component Type

© Copyright 2008 HVAC Design Solutions 10

Fan Static Pressure Calcs - #3Fan Static Pressure Calcs - #3FITTING Qs Qc VEL. PRESS COEFF. LOSS

TEE 1 - THRU TEE - FLOW NUMBER (CFM) (CFM) (Vp) (C) (IN.)STRAIGHT (45 DEG. TAKEOFF) 1 4500 6500 0.12 0.020 0.002

2 3000 4500 0.11 0.020 0.0023 2200 3000 0.08 0.020 0.0024 0 0 0 0.000 0.0005 0 0 0 0.000 0.0006 0 0 0 0.000 0.0007 0 0 0 0.000 0.0008 0 0 0 0.000 0.000

YELLOW 9 0 0 0 0.000 0.00010 0 0 0 0.000 0.000

0.006FITTING Qb Qc VEL. PRESS COEFF. LOSS

TEE 2 - BRANCH TEE - FLOW NUMBER (CFM) (CFM) (Vp) (C) (IN.)TURNS - 45 DEG. TAKEOFF 1 0 0 0 0.000 0.000

2 0 0 0 0.000 0.0003 0 0 0 0.000 0.0004 0 0 0 0.000 0.0005 0 0 0 0.000 0.0006 0 0 0 0.000 0.0007 0 0 0 0.000 0.000

YELLOW 8 0 0 0 0.000 0.0009 0 0 0 0.000 0.000

10 0 0 0 0.000 0.0000.000

CAUTION: LEAVING CFM (Qs) EXCEEDS ENTERING CFM (Qc).

CAUTION: LEAVING CFM (Qb) EXCEEDS ENTERING CFM (Qc).

Qc Qs

Qb

Qc

Easy Input of System Components and Air Quantities

Caution Flags for Improper Input Values

Built-in Fitting Coefficients

© Copyright 2008 HVAC Design Solutions 11

Fan Static Pressure Calcs - #4Fan Static Pressure Calcs - #4OPPOSED BLADE DAMPER 0.010IN DUCT OR AT DIFFUSER(ALSO, FIRE/SMOKE DAMPER) AIR DAMPER FITTING VELOCITY FITTING

FITTING QUANTITY ANGLE COEFF. PRESSURE LOSSNUMBER (CFM) (0,10,20,30) (C) (IN.) (IN.)

1 6500 10 0.85 0.12 0.1022 0 0 0 0 0.0003 0 0 0 0 0.000

0.102BUTTERFLY DAMPERTHIN PLATE, ROUND AIR DAMPER FITTING VELOCITY FITTING

FITTING QUANTITY ANGLE COEFF. PRESSURE LOSSNUMBER (CFM) (0,10,20,30) (C) (IN.) (IN.)

1 2200 10 0.52 0.07 0.0362 500 10 0.52 0.04 0.0213 0 0 0 0 0.000

0.057

TERMINAL UNIT (VAV BOX) PRESSURE DROP FROM MANUFACTURER'S DATA (IF KNOWN) 0 (IF NOT KNOWN, USE GENERIC UNITS, BELOW) 0.000

GENERIC VAV TERMINAL -WITH REHEAT COIL (SINGLE OR DUAL DUCT)

AIR REHEAT VAV BOX COIL TOTALFITTING QUANTITY COIL ROWS LOSS LOSS LOSS

NUMBER (CFM) (0=NONE,1,2) (IN.) (IN.) (IN.)1 1000 1 0.21 0.30 0.510

0.510

Q Q

Qc

Qc

Allowance for Items in Airstream

Generic Values Built-in (Conservative) if Mfgr’s. Data Unknown

© Copyright 2008 HVAC Design Solutions 12

Fan Static Pressure Calcs - #5Fan Static Pressure Calcs - #5SOUND TRAP - PRESSURE DROP FROM MANUFACTURER'S DATA (IF KNOWN) 0 0.000GENERIC SOUND TRAPS - IF INFORMATION NOT AVAILABLE (SOUND TRAP LENGTH - FT. (0,3,5,or 7)) 5 0.431

DIFFUSER - PRESSURE DROP FROM MANUFACTURER'S DATA (IF KNOWN) 0 0.000GENERIC DIFFUSER - IF INFORMATION NOT AVAILABLE MODULAR PERF. FACE (CFM) 500 0.140

MODULAR LOUVER FACE (CFM) 0 0.000

AIR FILTERS (EXTERNAL TO AH UNIT = 1, INTERNAL = 0) 0 0.000

TOTAL LENGTH - UNLINED SHEET METAL DUCT (FT.) 350 0.280

TOTAL LENGTH - LINED DUCT (FT.) 25 0.036

TOTAL LENGTH - FLEX DUCT (FT.) 7 0.011

BUILDING PRESSURIZATION 0.100

SUBTOTAL FAN STATIC PRESSURE 1.983

ALTITUDE CORRECTION FACTOR 0.978 1.940

SYSTEM EFFECT (IF APPLICABLE) OR SAFETY FACTOR (15%) 0.15 0.291

SUPPLY FAN STATIC PRESSURE 2.231

SOURCES: ASHRAE; SMACNA; AMCACOMPILE & PRINT

Adjustments for Altitude, System Effect, and/or Safety Factor

Imput Length of “Longest Run” Ductwork (PD based on “Supply Duct Sizing” Factor, above)

Final, Totalized Fan Static Pressure for the System

© Copyright 2008 HVAC Design Solutions 13

Fan Static Pressure Calcs - #6Fan Static Pressure Calcs - #6"YOUR COMPANY NAME"

SUPPLY FAN EXTERNAL STATIC PRESSURE CALCS

PROJECT ELEVATION = 670 PROJECT NAME:SUPPLY DUCT SIZING 0.08 PROJECT NUMBER: (FT./100 FT.) DATE:

FITTING AIR VELOCITY FITTING TOTALOR FITTING QUANTITY PRESSURE COEFF. LOSS FITTING

ITEM (DESCR.) (TYPE) NUMBER (CFM) (Vp) (C) (COEFF.) (IN.) LOSSELBOW 2 - DOUBLE THICKNESS 2 6500 0.12 0.53 0.127 0.170

1 3000 0.08 0.53 0.042TEE 1 - THRU TEE - FLOW 1 6500 0.12 0.020 0.002 0.006

2 4500 0.11 0.020 0.0023 3000 0.08 0.020 0.002

TRANSITION - CONTRACTION 1 15 0.11 0.050 0.006 0.0132 15 0.08 0.050 0.0043 15 0.07 0.050 0.004

TEE 3 - THRU TEE - FLOW 1 1000 0.05 0.020 0.001 0.001TEE 4 - BRANCH TEE - FLOW 1 2200 0.07 1.000 0.070 0.110

2 500 0.04 1.000 0.040WYE 3 - THRU WYE - FLOW 1 2200 0.07 0.090 0.006 0.006ELBOW 4 - ROUND (r/d=1.5) 1 500 0.04 0.240 0.010 0.010OPPOSED BLADE DAMPER 1 6500 0.12 0.850 0.102 0.102BUTTERFLY DAMPER 1 2200 0.07 0.520 0.036 0.057

2 500 0.04 0.520 0.021GENERIC VAV TERMINAL - 1 0.510 0.510GENERIC SOUND TRAPS - IF INFORMATION NOT AVAILABLE (SOUND TRAP LENGTH - FT. (0,3,5,or 7))5.000 0.431GENERIC DIFFUSER - IF INFORMATION NOT AVAILABLE MODULAR PERF. FACE (CFM) 0.140 0.140TOTAL LENGTH - UNLINED SHEET METAL DUCT (FT.) 0.280 0.280TOTAL LENGTH - LINED DUCT (FT.) 0.036 0.036TOTAL LENGTH - FLEX DUCT (FT.) 0.011 0.011

BUILDING PRESSURIZATION 0.100 0.100SUBTOTAL FAN STATIC PRESSURE 1.983 1.983ALTITUDE CORRECTION FACTOR 0.978 1.940SYSTEM EFFECT (IF APPLICABLE) OR SAFETY FACTOR (15%)0.291 0.291SUPPLY FAN STATIC PRESSURE 2.231 2.231

TEST PROJECT #11456-0706/21/07

© 2007 hvacdesignsolutions.com

After Input is complete, press “Compile & Print” Button for full System Report

© Copyright 2008 HVAC Design Solutions 14

Coil Psychrometrics CalcsCoil Psychrometrics CalcsHELP

91 67074 1075

AHU COOLING SUPPLY MINIMUM SUPPLY AIR RETURN AIR OUTSIDE AIR RETURN AIR ENTERING AIR LEAVING AIR COOLING CHILLED FLOOR CFM PER

NUMBER LOAD * AIR TEMP. OUTSIDE AIR QUANTITY TEMP. ENTHALPY ENTHALPY ENTHALPY ENTHALPY COIL LOAD WATER AREA SQ. FT.

(MBH) (°F) (CFM) (CFM) (°F) (BTU/LB.) (BTU/LB.) (BTU/LB.) (BTU/LB.) (MBH) (GPM) (SQ. FT)

1 12.5 54.0 150 590 78.0 37.7 30.2 32.1 21.7 26.1 5.2 400 1.52 18.2 54.0 320 859 78.0 37.7 30.2 33.0 21.7 41.1 8.2 650 1.33 46.3 54.0 1550 2186 78.0 37.7 30.2 35.5 21.7 126.6 25.3 2000 1.14 244.8 54.0 5500 11556 78.0 37.7 30.2 33.8 21.7 586.9 117.4 12950 0.95 42.0 54.0 1480 1983 78.0 37.7 30.2 35.8 21.7 117.2 23.4 1820 1.16 121.7 54.0 2640 5745 78.0 37.7 30.2 33.6 21.7 289.6 57.9 4800 1.27 24.5 54.0 450 1157 78.0 37.7 30.2 33.1 21.7 55.7 11.1 820 1.48 205.9 54.0 5120 9720 78.0 37.7 30.2 34.2 21.7 509.2 101.8 11200 0.99 105.5 54.0 2200 4980 78.0 37.7 30.2 33.5 21.7 248.2 49.6 4280 1.210 33.6 54.0 1250 1586 78.0 37.7 30.2 36.1 21.7 95.8 19.2 1500 1.111 19.5 54.0 250 921 78.0 37.7 30.2 32.2 21.7 41.2 8.2 700 1.312 150.3 54.0 2850 7095 78.0 37.7 30.2 33.2 21.7 344.7 68.9 6200 1.1

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

PROJECT ELEVATION =

CHILLED WATER DELTA-T =

AIR HANDLING UNIT - PRELIMINARY COOLING COIL LOAD CALCULATIONS

TEST PROJECT #1

1456-07

06/21/07

PROJECT NAME:

PROJECT NUMBER:

DATE:

OA DESIGN DB =

OA DESIGN WB =

DESIGN ROOM TEMP. =PRINTRESET/CLEAR

Psychrometric Calculations Assist with Preliminary Equipment Selection, Pump Sizing, Etc.

© Copyright 2008 HVAC Design Solutions 15

““Preliminary” Acoustical AnalysisPreliminary” Acoustical Analysis

PROJECT NAME:

PROJECT NUMBER:

8 DATE:

0.15 W L H(INSIDE DIMENSIONS) 30 20 12

2400

63 125 250 500 1000 2000 4000 80001 2 3 4 5 6 7 8

TOTAL, LINES 1 THRU 3 95 90 85 80 75 71 67 65MINUS 3 dB SAFETY FACTOR -3 -3 -3 -3 -3 -3 -3 -3

TEST PROJECT #1

1456-07

6/21/2007

68 64 6287 82 77 72

1111

37

11 11

23 19

11

37 37

11 11

17

37 37 37

42 37 32 27

37 37

47

11

92

Line 1 thru 3

Deduct Safety Factor

100

FAN ROOM ACOUSTICAL TYPE:

LOUVER AREA (sq. ft.):

ROOM DIMENSIONS (feet):

MAX. ALLOWABLE LOUVER P.D. (in.)

4

CRITERION, Db (AMBIENT SOUND LEVELS)

DIVERGENCE, dB

ROOM ABSORPTION, dB

NOISE SOURCE PERMISSIBLE PWL, dB

1

ROOM SURFACE AREA (sq. ft.):

2

3

DISTANCE FROM LOUVER TO NOISE SOURCE - FAN (feet):

Table 1-A

Table 2

Table 3

PRELIMINARY EXTERIOR ACOUSTICAL ANALYSIS(RESULTS SHOULD BE VERIFIED BY AN ACOUSTICAL CONSULTANT)

LINE NO.

CALCULATIONS DATA SOURCEOCTAVE BAND NUMBERS

CONDITION AT POINT-OF-INTEREST:

15DISTANCE FROM LOUVER TO POINT-OF-INTEREST (feet):

Nighttime, suburban; no nearby traffic of concern

AVERAGE

PRINT

RESET/CLEAR

Program Helps to Determine whether sound control equipment will be required

© Copyright 2008 HVAC Design Solutions 16

Duct Sheet Metal Weight and Duct Sheet Metal Weight and Insulation Sq. Ft. EstimatesInsulation Sq. Ft. Estimates

HELP

* FITTINGS MULTIPLIER PROJECT NAME: ADJUSTS FOR SCRAP PROJECT NUMBER: LOSSES AT FITTINGS - DATE: (NORMALLY 10% = 1.10 MULT. )

TOTAL FITTINGS CORRECTED SQ. FT. LBS. PER LBS. PER TOTAL TOTAL

WIDTH (IN.) DEPTH (IN.) LENGTH (FT.) MULT. * LENGTH (FT.) PER LIN. FT. SQ. FT. LIN. FT. LBS. SQ. FT.

80 24 90 1.10 99 19.93 1.656 33.010 3268 197362 24 150 1.10 165 16.48 1.656 27.296 4504 272060 22 30 1.10 33 15.72 1.406 22.098 729 51954 18 24 1.10 26.4 13.80 1.406 19.403 512 36448 24 120 1.10 132 13.80 1.406 19.403 2561 182236 24 48 1.10 52.8 11.50 1.406 16.169 854 60728 22 60 1.10 66 9.58 1.156 11.078 731 63324 18 120 1.10 132 8.05 1.156 9.306 1228 106320 14 60 1.10 66 6.52 1.156 7.533 497 43018 12 45 1.10 49.5 5.75 1.156 6.647 329 28514 8 180 1.10 198 4.22 1.156 4.874 965 83512 6 380 1.10 418 3.45 0.906 3.126 1307 1442

1.10 0 0.00 0.000 0.000 0 01.10 0 0.00 0.000 0.000 0 0

TEST PROJECT #11456-0706/21/07

RECTANGULAR DUCT

SHEET METAL WEIGHT AND INSULATION CALCULATIONS

PRINT

RESET/CLEAR

Quick and Easy Input - Output Helps with Cost Estimating

Rectangular and Round Ducts with Total Lbs. And Insulation Sq. Ft.

© Copyright 2008 HVAC Design Solutions 17

Air Balance TabulationsAir Balance Tabulations

PROJECT NAME:

PROJECT NUMBER:

DATE:

ROOM OR SYSTEM AIR BALANCE TABULATION

PRINTRESET/CLEAR

ROOM NAME AND NUMBER SUPPLY RETURN EXHAUST TRANSFER

SUPPLY RETURN EXHAUST CFM CFM CFM CFM

OFFICE 101 AHU-1 AHU-1 EF-2 1500 1200 500

OFFICE 102 AHU-1 AHU-1 4500 4000 300

OFFICE 103 AHU-1 AHU-1 6250 5850 300

CONFERENCE ROOM AHU-1 AHU-1 EF-2 600 200 350

MEN'S ROOM AHU-1 AHU-1 EF-1 300 1200

WOMEN'S ROOM AHU-1 AHU-1 EF-1 300 1200

OFFICE 201 AHU-2 AHU-2 6500 6000 400

OFFICE 202 AHU-2 AHU-2 5750 5200 400

LAB #1 AHU-2 N/A EF-3 2500 5000

LAB #2 AHU-2 N/A EF-4 2500 5000

LAB #3 AHU-2 N/A EF-5 2500 5000

LAB #4 AHU-2 N/A EF-6 2500 5000

CONFERENCE #2 AHU-2 AHU-2 EF-12 600 200 350

STORAGE ROOM AHU-2 AHU-2 EF-7 450

JANITOR'S ROOM AHU-2 AHU-2 EF-7 300

MEN'S ROOM AHU-2 AHU-2 EF-8 300 1200

WOMEN'S ROOM AHU-2 AHU-2 EF-8 300 1200

OFFICE 301 AHU-3 AHU-3 5200 4600 350

OFFICE 302 AHU-3 AHU-3 4850 4200 350

LAB #5 AHU-3 N/A EF-9 2000 4000

LAB #6 AHU-3 N/A EF-10 2000 4000

LAB #7 AHU-3 N/A EF-11 2000 4000

AIR BALANCE

EQUIPMENT NUMBER

AIR CHANGE

ROOM CEILING VOLUME PER BALANCE (+) OR (-)

SQ. FT. HEIGHT CU. FT. HOUR (+,-,N) CFM1200 8 9600 9.4 (-) -2005200 8 41600 6.5 (+) 2006600 8 52800 7.1 (+) 100450 8 3600 10.0 (+) 50550 8 4400 4.1 (-) -900600 8 4800 3.8 (-) -9006100 8 48800 8.0 (+) 1005300 8 42400 8.1 (+) 1502500 8 20000 7.5 (-) -25002500 8 20000 7.5 (-) -25002500 8 20000 7.5 (-) -25002500 8 20000 7.5 (-) -2500450 8 3600 10.0 (+) 50350 8 2800 0.0 (-) -450150 8 1200 0.0 (-) -300550 8 4400 4.1 (-) -900600 8 4800 3.8 (-) -9005000 8 40000 7.8 (+) 2504600 8 36800 7.9 (+) 3002000 8 16000 7.5 (-) -20002000 8 16000 7.5 (-) -20002000 8 16000 7.5 (-) -2000

0 0.0 (N) 0

PRESSURIZATIONROOM VOLUME

Show Room-To-Room Air Balance Relationships and System Totals

Copy-and-Paste onto Drawings to show Pressure Relationship Compliance

© Copyright 2008 HVAC Design Solutions 18

Project Information Request LettersProject Information Request Letters

HELP

PROJECT NAME: DATE: 06/21/07

PROJECT NUMBER:

REQUESTED BY:

1. All Offices

2. Conference Rooms

3. Photocopy machine rooms

4. Lounge and/or lunch rooms

5. Electrical equipment rooms

6. Computer Rooms

7. Procedure Rooms

8. Other specialty rooms

B. Please indicate any special HVAC requirements such as areas requiring:

1. 24 Hour Air Conditioning

2. Relative Humidity Controls

The above information should include: PC Stations, Laser Printers, Fax Machines, Photocopy Machines, Microwaves, Vending Machines, Refrigerators, Coffee Makers, Special Lighting, etc. If available, this information should contain: quantity, location, BTU/hr, wattage, amperage, voltage, heat output to the space, operating cycle time, etc.

Please provide the following information, to expedite our design of your project. It is very important that you respond as soon as possible, with as accurate information as you have available, so we can calculate the correct air conditioning requirements and make accurate equipment selections.

A. Please provide the number of people, heat output or amperage and voltage of equipment, and any other element that might effect the HVAC load in the following areas:

1456-07

TEST PROJECT #1

BUILDING MECHANICAL INFORMATION REQUESTHELP

PROJECT NAME: DATE: 06/21/07

PROJECT NUMBER:

REQUESTED BY:

ROOM NAME/NUMBER:

NUMBER OF PEOPLE

HEAT PRODUCING EQUIPMENT (Please Indicate Quantity Below)

PC Stations Laser Printers

Photocopy Machines Fax Machines

Microwaves TV Sets or Monitors

Refrigerators (Small – S, Large – L) Vending Machines

Coffee Makers

Special Lighting (Total Watts to Room)

Special Equipment (Total Watts to Room)

Exposed Motors in Room (Horsepower)

NO HEAT PRODUCING EQUIPMENT IN THIS ROOM

SPECIAL OPERATING CONDITIONS

24 Hour Air Conditioning Required

BUILDING MECHANICAL ROOM INFORMATION REQUEST FORM

PEOPLE ACTIVITY LEVEL: (S) - Seated Office; (M) - Moderate Office; (W) - Walking or Standing; (B) - Bench Work; (H) Heavy Work

TEST PROJECT #1

1456-07

“Programming” Information Request Forms for Owner or Architect Input

© Copyright 2008 HVAC Design Solutions 19

Extensive “Quality Control” Mechanical Checklists are available in a separate “Mechanical Peer Review” Software Package

Coordination Between Disciplines

Contents: (Click on hyperlink to jump to the sheet checklist)

A Preliminary Review of Plans and SpecificationsB Demolition PlansC Architect and/or Owner CoordinationD Structural CoordinationE Mechanical CoordinationF Plumbing CoordinationG Civil Engineering CoordinationH Electrical Coordination

A Preliminary Review of Plans and Specifications1 Quickly review all Drawings in the Construction Document set, including Architectural,

Structural, Civil, Landscaping, Mechanical, Plumbing, Fire Protection, Electrical, FoodService, and any other discipline. Spend not more than one minute per sheet, average.

2 Make a list of any apparent discrepancies or questions while reviewing the set, and add‘flags’ to sheets where there are significant questions.

3 Quickly review the Specif ications by reading through the Table of Contents forMechanical and Plumbing work. Check the Table of Contents against the actualSpecification sections to verify all sections have been included. Make a list of questionsthat may come up during the cursory review.

4 Review Architectural T itle Sheet, or first sheet in the set, and make a list of the ProjectSquare Footage, Building Occupancy Type, Building Construction Type, GoverningCodes, Index of Drawings, and any other information that relates to Mechanical orPlumbing work.

5 Check for consistent appearance of Title Blocks, Drawing Scales, North Arrows,Professional Stamps, Company Logos, Sheet Numbers, Sheet Tit les, Issue Dates, andIssue Revisions on all sheets.

B Demolition Plans1 Verify that Demolition Symbols (cross-hatching, etc.) are clear and complete, and are

coordinated with other disciplines.2 Verify there are notes regarding potential hazardous materials (asbestos, lead paint,

etc.), and coordinate with Architect or other Prime Consultant and Owner.

““Mechanical Peer Review” SoftwareMechanical Peer Review” Software

Over (110) Pages of Checklists and Spreadsheets for a thorough review of Mechanical Construction Documents

© Copyright 2008 HVAC Design Solutions 20

““Mechanical Peer Review” SoftwareMechanical Peer Review” Software

Mechanical Plan Review Items

Contents: (Click on hyperlink to jump to the sheet checklist)

A Preliminary Review of Plans and SpecificationsB Legend and Symbols SheetC Schedule SheetsD Mechanical Demolition PlansE Mechanical Ductwork Floor PlansF Mechanical Piping PlansG Mechanical Roof PlansH Mechanical Central Plant PlansI Clean Room and Fabrication FacilitiesJ Mechanical Piping DiagramsK Mechanical Control DrawingsL Mechanical Detail Drawings

A Mechanical Piping Plans Return to Table of Contents1 Sum all Chilled Water Supply and Return quantities (GPM’s) from coils back to service

connection or pumps. Pencil in quantities adjacent to pipes. Verify flow rates are listedfor all coils or equipment, and that Schedules for each device are complete. Check flowdirection Arrows for completeness and correct direction.

2 Sum all Heating Water Supply and Return quantities (GPM’s) same as Chilled Water.Pencil in quantities. Verify Schedule information is complete. Check flow directionArrows.

3 Check for provisions for Water Balancing on plans or on details of coil connections.4 Check for Isolation Valves to allow servicing without shutting down and draining entire

systems.5 Verify whether Direct-return or Reverse-return piping. Suggest Reverse-return for better

water balancing, if appropriate.6 Check provisions for Condensate Drains. Coordinate with Plumbing drawings for piping

and Approved Disposal methods.7 Check on provisions for Air Venting and Drainage – on Coil Piping Details and plans.8 Check Thermostat locations (if thermostats are shown on Piping Plans) and verify all

heating and cooling elements have a corresponding Thermostat or Sensor Control.9 Spot-check pipe sizes against totalized water quantities. Use maximum of 4 ft. per 100 ft.

pipe friction, up to 5” pipe size, and maximum of 8 ft. per second Velocity for pipe 6” andlarger.

10 Check for provisions for Pipe Expansion – Pipe Loops, adequate turns (less than 50 feetof straight pipe), or expansion devices.

11 Check for restrictions to pipe movement – against columns, against solid walls, drops orrises to adjacent floors.

12 Verify that pipes are not run through Stairwells, Elevator Shafts, Columns, or ElectricalRooms.

13 Compare Totalized water quantities with associated Pumps, and analyze diversity if totalsare not equal.

14 Verify that all pipes are sized.15 Coordinate Pipe plans with Ductwork plans and identify any potential conflicts.

Example of Quality Control Check List Items

© Copyright 2008 HVAC Design Solutions 21

Calculation DocumentsCalculation Documents

PROJECT NAME:

PROJECT NUMBER:

DATE:

TEST PROJECT #1

1456-07

6/21/2007

ROOM OR SYSTEM AIR BALANCE TABULATION

ROOM NAME AND NUMBER SUPPLY RETURN EXHAUST TRANSFERSUPPLY RETURN EXHAUST CFM CFM CFM CFM

OFFICE 101 AHU-1 AHU-1 EF-2 1500 1200 500OFFICE 102 AHU-1 AHU-1 4500 4000 300OFFICE 103 AHU-1 AHU-1 6250 5850 300

CONFERENCE ROOM AHU-1 AHU-1 EF-2 600 200 350MEN'S ROOM AHU-1 AHU-1 EF-1 300 1200WOMEN'S ROOM AHU-1 AHU-1 EF-1 300 1200

OFFICE 201 AHU-2 AHU-2 6500 6000 400OFFICE 202 AHU-2 AHU-2 5750 5200 400LAB #1 AHU-2 N/A EF-3 2500 5000

LAB #2 AHU-2 N/A EF-4 2500 5000LAB #3 AHU-2 N/A EF-5 2500 5000LAB #4 AHU-2 N/A EF-6 2500 5000

CONFERENCE #2 AHU-2 AHU-2 EF-12 600 200 350STORAGE ROOM AHU-2 AHU-2 EF-7 450JANITOR'S ROOM AHU-2 AHU-2 EF-7 300

MEN'S ROOM AHU-2 AHU-2 EF-8 300 1200WOMEN'S ROOM AHU-2 AHU-2 EF-8 300 1200OFFICE 301 AHU-3 AHU-3 5200 4600 350

OFFICE 302 AHU-3 AHU-3 4850 4200 350LAB #5 AHU-3 N/A EF-9 2000 4000LAB #6 AHU-3 N/A EF-10 2000 4000

LAB #7 AHU-3 N/A EF-11 2000 4000

EQUIPMENT NUMBERAIR BALANCE AIR CHANGE

ROOM CEILING VOLUME PER BALANCE (+) OR (-)SQ. FT. HEIGHT CU. FT. HOUR (+,-,N) CFM

1200 8 9600 9.4 (-) -2005200 8 41600 6.5 (+) 2006600 8 52800 7.1 (+) 100

450 8 3600 10.0 (+) 50550 8 4400 4.1 (-) -900600 8 4800 3.8 (-) -900

6100 8 48800 8.0 (+) 1005300 8 42400 8.1 (+) 1502500 8 20000 7.5 (-) -2500

2500 8 20000 7.5 (-) -25002500 8 20000 7.5 (-) -25002500 8 20000 7.5 (-) -2500

450 8 3600 10.0 (+) 50350 8 2800 (-)150 8 1200 (-)

550 8 4400 4.1 (-) -900600 8 4800 3.8 (-) -9005000 8 40000 7.8 (+) 250

4600 8 36800 7.9 (+) 3002000 8 16000 7.5 (-) -20002000 8 16000 7.5 (-) -2000

2000 8 16000 7.5 (-) -2000(N)(N)

PRESSURIZATIONROOM VOLUME

After completing input and calculations, Output and Sizing Documents can be printed for submittal to building department officials and for addition to drawings and schedules

© Copyright 2008 HVAC Design Solutions 22

Software ContentsSoftware Contents

AIRBALROOM OR SYSTEM AIR BALANCE TABULATION

DUCTCALC

SUPPLY-DUCT

DUCT SIZING CALCULATOR - TO AVOID OBSTRUCTIONS

SUPPLY DUCT SIZING SCHEDULE - TO AVOID OBSTRUCTIONS

RET-EXH-DUCT

PRELIMINARY FAN STATIC PRESSURE CALCULATIONS

SHEETMETAL-WT.

AHU-COOL. COIL

RETURN/EXHAUST DUCT SIZING SCHEDULE - TO AVOID OBSTRUCTIONS

STAT.REGAIN-DUCT

STATIC REGAIN DUCT SIZING SCHEDULE - TO AVOID OBSTRUCTIONS

AHU-HTG.COIL

VAV REHEAT

EXTSPFAN

AHU - PRELIMINARY HEATING COIL LOAD CALCULATIONS

VAV - REHEAT COIL LOAD CALCULATIONS

AHU - PRELIMINARY COOLING COIL LOAD CALCULATIONS

SHEET METAL WEIGHT AND INSULATION CALCULATIONS

SUP. FAN SP

RET-EXH FAN SP

SUPPLY FAN EXTERNAL STATIC PRESSURE CALCULATIONS

RETURN FAN OR EXHAUST FAN EXTERNAL STATIC PRESSURE CALCULATIONS

PRELIMINARY COOLING TOWER ACOUSTICAL ANALYSIS

EXTERSOUNDPRELIMINARY EXTERIOR ACOUSTICAL ANALYSIS

TOWERSOUND

PRELIMINARY ROOM ACOUSTICAL ANALYSISROOMSOUND

Bldg. Info. 2

Ceiling Space

Bldg. Info.BUILDING MECHANICAL INFORMATION REQUEST FORM

BUILDING MECHANICAL ROOM INFORMATION REQUEST FORM

CEILING SPACE INFORMATION REQUEST FORM

Extensive Airside Programs to help “Streamline” your Design Procedures

Straightforward takeoff and input allows easy calculation and sizing of Airside Systems.

Extensive procedures, formulas, charts, and tables as prescribed by Mechanical Codes and as recommended by ASHRAE and SMACNA have been included and have been used to establish the “Accurate” Airside System Sizes.

Multiple Programs are included, covering most of the typical Airside Design Tasks for most projects.

© Copyright 2008 HVAC Design Solutions 23

Features and BenefitsFeatures and Benefits

Significantly reduces “Reference Material Dependence” which can save a great deal of time and effort.

Output in the form of Compliance Documents or System Sizing Summaries for submittal to appropriate code enforcement officials or building departments.

Extensive “Help Files” that are hyperlinked to each program, form, or table.

© Copyright 2008 HVAC Design Solutions 24

Features and BenefitsFeatures and Benefits

Limited time “Special Pricing” available at our website www.hvacdesignsolutions.com

Airside Design Package Original Price: $250 US, Special Price: $189 US

Mechanical Peer Review Package Original Price: $275 US, Special Price: $198 US

© Copyright 2008 HVAC Design Solutions 25

PricingPricing

Current Version: 2.23, with latest update (08/24/2008) Free updates, as available.

To purchase Airside Design or Mechanical Peer Review, visit our website at www.hvacdesignsolutions.com and go to the Prices/Orders page

Software can be downloaded for immediate installation (with password) after purchase is confirmed

© Copyright 2008 HVAC Design Solutions 26

AvailabilityAvailability

OS: Windows® 98, 2000, XP, 2003, Vista Processor: Pentium® or equivalent Ram: 512MB (minimum recommended) Disk Space: 100 MB (recommended) Software: MS Word®, MS Excel®

© Copyright 2008 HVAC Design Solutions 27

System RequirementsSystem Requirements

Thank you for taking your time to review our Airside Design software packages

If you have any questions or comments, you can e-mail to: steve”at”hvacdesignsolutions.com , or support”at”hvacdesignsolutions.com

We also have an interactive demo of our Airside Design software that can be delivered, on request, via e-mail.

© Copyright 2008 HVAC Design Solutions 28

Thanks!Thanks!