ak-6we fireplace combustion air vent 112098-01e
TRANSCRIPT
-
8/18/2019 AK-6WE Fireplace Combustion Air Vent 112098-01E
1/1
1. Locate air inlet cover plate on replace‘s outer surround. Remove screws and plate.
2. Cut out any visible insulation that may obstruct airow.
3. Extend ex duct to attach air inlet tube.
4. Insert inner tab of inlet tube into slot next to opening. Place outer tab of inlet tube over hole next to opening.
5. Secure with screws removed from cover plate in step 1.
6. Construct a 8" x 8" inside framing or opening on exterior wall.
7. Install outside air vent termination in a location that would not eventually be obstructed by bushes, snow or other obstructions. Locate vent near replace to make ex duct installation easier.
8. The ex duct supplied measures approximately 10" compressed and up to 3 feet extended.
Outside Air VentTermination
112098-01
Rev. E
09/08NOT A UPC112098 01
AK-6WEOUTSIDE AIR KIT
FOR WOOD BURNING FIREPLACE
INSTALLATION INSTRUCTIONS
Insulation
Left SideMountingShown
Secure to Collar withMetal Tape, Screwsor Tie Straps(Not Supplied)
Insert Inner Tab ofInlet Tube Into Sloton Outer Surround
Air Vent LocationMust Allow ForBushes, Snow andOther PossibleObstructions
Remove Knockout
Sheet Metal ScrewTab in Notch Air Inlet Tube
The maximum height for the air vent can not exceed3 feet below the ue gas outlet of the termination.
DESA Heating, LLC
2701 Industrial Drive
Bowling Green, KY 42101
www.desatech.com