6
THIS PROJECT ENTAILS THE UPGRADE OF COMMUNICATION PATHWAYS TO FIBER CABLING FOR KEY BHCS FACILITIES ON THE FAIRMONT HOSPITAL CAMPUS. THE OBJECTIVE IS TO UPGRADE THE EXISTING BACKBONE CABLING INFRASTRUCTURE TO SUPPORT FUTURE DATA SERVICES. DIRECTORY CLIENT COUNTY OF ALAMEDA GSA/TSD 1401 LAKESIDE DRIVE, SUITE 800 OAKLAND, CA 94612 P: 510-208-9825 CONTACT: GERALD LOEPER ALAMEDA HEALTH SYSTEM 15400 FOOTHILL BLVD SAN LEANDRO, CA 64578 P: 510-895-4556 CONTACT: NILESH LAL ELECTRICAL AND TECHNOLOGY ENGINEER INTERFACE ENGINEERING 135 MAIN STREET, SUITE 400 SAN FRANCISCO, CA 94105 P: 415 489 7242 F: 415 489 7289 CONTACT: JOEL CRUZ MACK5 1900 POWELL STREET, SUITE 470 EMERYVILLE, CA 94608 P: 510-595-3022 CONTACT: MANIL BAJRACHARYA PROJECT DESCRIPTION VICINITY MAP PROJECT LOCATION FAIRMONT HOSPITAL CAMPUS SAN LEANDRO, CA 94575 SHEET INDEX CODE REFERENCE 2013 CALIFORNIA BUILDING CODE (CBC) PART 2, TITLE 24, CCR (2012 IBC AND 2013 CALIFORNIA AMENDMENTS) 2013 CALIFORNIA ELECTRICAL CODE (CEC) PART 3, TITLE 24, CCR (2012 NEC AND 2013 CALIFORNIA AMENDMENTS) 2013 CALIFORNIA FIRE CODE (CFC) PART 9, TITLE 24, CCR (2012 IFC AND 2013 CALIFORNIA AMENDMENTS) CALIFORNIA CODE REGULATIONS (CCR), TITLE 8 - INDUSTRIAL RELATIONS, SUBCHAPTER 4, CONSTRUCTION SAFETY ORDERS. CALIFORNIA CODE REGULATIONS (CCR), TITLE 19 - PUBLIC SAFETY VOLUME 25, ARTICLE 14, SECTION 18958, HEALTH AND SAFETY CODE. THE CONTRACTOR IS REQUIRED TO COMPLY WITH THE ABOVE CODES AND REGULATIONS AND ALL OTHER CODES OR ZONING REQUIREMENTS. ADVISE ENGINEER AND CLIENT OF ANY NON-COMPLIANCE IN THE CONSTRUCTION DOCUMENTS PRIOR TO PROCEEDING WITH WORK. ALAMEDA COUNTY FAIRMONT CAMPUS BHCS DATA UPGRADE 15430 FOOTHILL BLVD SAN LEANDRO, CA 94575 PROJECT NO. 15024 REVISIONS DATE JOB NO. CHECKED BY DRAWN BY SHEET NUMBER SHEET TITLE 135 Main Street Suite 400 San Francisco, CA 94105 TEL 415.489.7240 FAX 415.489.7289 www.interfaceengineering.com Jason Nguyen Westley Anastasio 2016-0272 11-02-2016 ALAMEDA COUNTY FAIRMONT CAMPUS BHCS DATA UPGRADE 15430 FOOTHILL BLVD SAN LEANDRO, CA 94575 CONTACT PROJECT 135 Main Street Suite 400 San Francisco, CA 94105 TEL 415.489.7240 FAX 415.489.7289 www.interfaceengineering.com Jason Nguyen 2016-0272 T0.1 SYMBOL LIST & GENERAL NOTES T1.1 SITE PLAN - TECHNOLOGY T2.1 SOBERING BUILDING PLAN, ENLARGED PLAN & PANEL SCHEDULE - TECHNOLOGY T3.1 DETAILS - TECHNOLOGY T3.2 PHOTOS - TECHNOLOGY T0.0 TITLE SHEET

Upload: lynhan

Post on 01-Apr-2018

214 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: ALAMEDA COUNTY FAIRMONT CAMPUS BHCS DATA UPGRADE - ACGOV.org · this project entails the upgrade of communication pathways to fiber cabling for key ... approval by alameda health

THIS PROJECT ENTAILS THE UPGRADE OF COMMUNICATION PATHWAYS TO FIBER CABLING FOR KEY

BHCS FACILITIES ON THE FAIRMONT HOSPITAL CAMPUS. THE OBJECTIVE IS TO UPGRADE THE EXISTING

BACKBONE CABLING INFRASTRUCTURE TO SUPPORT FUTURE DATA SERVICES.

DIRECTORY

CLIENT

COUNTY OF ALAMEDA GSA/TSD

1401 LAKESIDE DRIVE, SUITE 800

OAKLAND, CA 94612

P: 510-208-9825

CONTACT: GERALD LOEPER

ALAMEDA HEALTH SYSTEM

15400 FOOTHILL BLVD

SAN LEANDRO, CA 64578

P: 510-895-4556

CONTACT: NILESH LAL

ELECTRICAL AND TECHNOLOGY ENGINEER

INTERFACE ENGINEERING

135 MAIN STREET, SUITE 400

SAN FRANCISCO, CA 94105

P: 415 489 7242

F: 415 489 7289

CONTACT: JOEL CRUZ

MACK5

1900 POWELL STREET, SUITE 470

EMERYVILLE, CA 94608

P: 510-595-3022

CONTACT: MANIL BAJRACHARYA

PROJECT DESCRIPTION

VICINITY MAP

PROJECT LOCATION

FAIRMONT HOSPITAL CAMPUS

SAN LEANDRO, CA 94575

SHEET INDEX

CODE REFERENCE

2013 CALIFORNIA BUILDING CODE (CBC)

PART 2, TITLE 24, CCR

(2012 IBC AND 2013 CALIFORNIA AMENDMENTS)

2013 CALIFORNIA ELECTRICAL CODE (CEC)

PART 3, TITLE 24, CCR

(2012 NEC AND 2013 CALIFORNIA AMENDMENTS)

2013 CALIFORNIA FIRE CODE (CFC)

PART 9, TITLE 24, CCR

(2012 IFC AND 2013 CALIFORNIA AMENDMENTS)

CALIFORNIA CODE REGULATIONS (CCR), TITLE 8 - INDUSTRIAL RELATIONS, SUBCHAPTER 4,

CONSTRUCTION SAFETY ORDERS.

CALIFORNIA CODE REGULATIONS (CCR), TITLE 19 - PUBLIC SAFETY VOLUME 25, ARTICLE 14,

SECTION 18958, HEALTH AND SAFETY CODE.

THE CONTRACTOR IS REQUIRED TO COMPLY WITH THE ABOVE CODES AND REGULATIONS AND

ALL OTHER CODES OR ZONING REQUIREMENTS. ADVISE ENGINEER AND CLIENT OF ANY

NON-COMPLIANCE IN THE CONSTRUCTION DOCUMENTS PRIOR TO PROCEEDING WITH WORK.

ALAMEDA COUNTY FAIRMONT CAMPUS BHCS DATA UPGRADE

15430 FOOTHILL BLVD

SAN LEANDRO, CA 94575

PROJECT NO. 15024

REVISIONS

DATE

JOB NO.

CHECKED BY

DRAWN BY

SHEET NUMBER

SHEET TITLE

135 Main Street

Suite 400

San Francisco, CA 94105

TEL 415.489.7240

FAX 415.489.7289

www.interfaceengineering.com

Jason Nguyen

Westley Anastasio

2016-0272

11-02-2016

AL

AM

ED

A C

OU

NT

Y F

AIR

MO

NT

C

AM

PU

S

BH

CS

D

AT

A U

PG

RA

DE

15430 F

OO

TH

IL

L B

LV

D

SA

N L

EA

ND

RO

, C

A 94575

CONTACT

PROJECT

135 Main Street

Suite 400

San Francisco, CA 94105

TEL 415.489.7240

FAX 415.489.7289

www.interfaceengineering.com

Jason Nguyen

2016-0272

T0.1 SYMBOL LIST & GENERAL NOTES

T1.1 SITE PLAN - TECHNOLOGY

T2.1 SOBERING BUILDING PLAN, ENLARGED PLAN & PANEL SCHEDULE

- TECHNOLOGY

T3.1 DETAILS - TECHNOLOGY

T3.2 PHOTOS - TECHNOLOGY

T0.0

TITLE SHEET

Page 2: ALAMEDA COUNTY FAIRMONT CAMPUS BHCS DATA UPGRADE - ACGOV.org · this project entails the upgrade of communication pathways to fiber cabling for key ... approval by alameda health

GENERAL NOTES

A. DO NOT COMMENCE INSTALLATION OF ELECTRICAL SYSTEMS AND EQUIPMENT

WITHOUT RELATED SHOP DRAWING APPROVALS.

B. ELECTRICAL CIRCUITS SHALL BE INTERRUPTED ONLY WITH PRIOR WRITTEN CONSENT.

SUCH INTERRUPTIONS SHALL BE PRECEDED BY ALL POSSIBLE PREPARATIONS BY THE

CONTRACTOR WHICH ARE NECESSARY TO KEEP THE ELECTRICAL CIRCUITS OFF FOR A

MINIMUM PERIOD IN AN EXPEDITIOUS MANNER PURSUANT WITH GOOD WORKMANSHIP.

THIS INCLUDES CIRCUIT TRACING TO IDENTIFY THE ELECTRICAL LOAD BEING SERVED

AND THE ORIGIN OF THE CIRCUIT.

C. COORDINATE WITH OWNER SO THAT WORK CAN BE SCHEDULED NOT TO INTERRUPT

OPERATIONS, NORMAL ACTIVITIES, BUILDING ACCESS, ACCESS TO DIFFERENT AREAS.

THE OWNER WILL COOPERATE TO THE BEST OF THEIR ABILITY TO ASSIST IN A

COORDINATED SCHEDULE, BUT WILL REMAIN THE FINAL AUTHORITY AS TO TIME OF

WORK PERMITTED.

D. COORDINATE THE EXACT LOCATION OF EXISTING UTILITIES AND EQUIPMENT PRIOR TO

COMMENCEMENT OF WORK. COMPENSATE THE OWNER FOR DAMAGES CAUSED BY THE

FAILURE TO LOCATE AND PRESERVE UTILITIES. REPLACE DAMAGED ITEMS WITH NEW

MATERIAL TO MATCH EXISTING.

E. MAINTAIN ELECTRICAL CONTINUITY OF EXISTING SYSTEMS. REMOVE OR RELOCATE

ELECTRICAL BOXES, CONDUIT, WIRING, EQUIPMENT, LUMINAIRES, AND THE LIKE, AS

REQUIRED IN REMOVED OR REMODELED AREAS IN THE EXISTING CONSTRUCTION

AFFECTED BY THIS WORK.

F. REMOVE AND RESTORE WIRING WHICH SERVES USABLE EXISTING OUTLETS CLEAR OF

THE CONSTRUCTION OR DEMOLITION.

G. IF EXISTING JUNCTION BOXES WILL BE MADE INACCESSIBLE, OR IF ABANDONED

OUTLETS SERVE AS FEED THROUGH BOXES FOR OTHER EXISTING ELECTRICAL

EQUIPMENT WHICH IS BEING RETAINED, PROVIDE NEW CONDUIT AND WIRE TO BYPASS

THE ABANDONED OUTLETS.

H. IF EXISTING CONDUITS PASS THROUGH PARTITIONS OR CEILING WHICH ARE BEING

REMOVED OR REMODELED, PROVIDE NEW CONDUIT AND WIRE TO REROUTE CLEAR OF

THE CONSTRUCTION OR DEMOLITION AND MAINTAIN SERVICE TO THE EXISTING LOAD.

I. CONCEALED CONDUIT LOCATED IN CONCRETE WALLS OR HARDBOARD CEILING

SPACES MAY BE ABANDONED IN PLACE. REMOVE CONDUCTORS AND TAG ABANDONED

CONDUITS WITH CORRESPONDING SYSTEM AND TERMINATION POINT. CUT AND CAP

ABANDONED CONDUIT. DO NOT EXTEND STUBS ABOVE FINISHED FLOOR.

J. PROVIDE TEMPORARY SUPPORT FOR ELECTRICAL SYSTEMS THAT REMAIN IN PLACE.

K. PROVIDE BLANK COVER PLATE FOR ABANDONED FLUSH OUTLETS.

L. MAINTAIN ACCESS TO EXISTING ELECTRICAL INSTALLATIONS WHICH REMAIN ACTIVE.

MODIFY INSTALLATION OR PROVIDE ACCESS PANEL AS APPROPRIATE.

M. PROVIDE SUITABLE ANCHORAGE AND SUPPORT FOR ELECTRICAL EQUIPMENT IN RATED

WALLS, SLABS AND CEILINGS. MOUNT DEVICES AND RACEWAYS IN ACCORDANCE WITH

ESTABLISHED CODES AND SPECIFICATIONS.

N. CONNECT EQUIPMENT AND DEVICES FURNISHED UNDER OTHER DIVISIONS OF THIS

CONTRACT, BY OWNER OR BY OTHER CONTRACTS.

O. UNLESS OTHERWISE NOTED, PROVIDE CONCEALED AND FLUSH MOUNTED

INSTALLATION OF DEVICES AND EQUIPMENT IN AREAS.

P. FOR 120 VOLT, 20 AMP CIRCUITS, WHERE CIRCUIT DISTANCE FROM PANELBOARD TO

FARTHEST DEVICE/FIXTURE EXCEEDS 75 FEET, PROVIDE #10 SIZE CONDUCTOR.

Q. RUN ELECTRICAL CONDUIT CONCEALED AND PARALLEL TO BUILDING LINES. VERIFY

WITH ENGINEER.

R. RECEPTACLE OUTLETS SHALL COMPLY WITH CEC SECTION 210.7.

S. BRACE ELECTRICAL EQUIPMENT TO RESIST A HORIZONTAL FORCE THAT ACT IN ANY

DIRECTION. COMPLY WITH TITLE 24 REQUIREMENTS.

T. INSTALL COMPLETE SYSTEM OF CONDUCTORS IN RACEWAY SYSTEM THROUGHOUT

BUILDING FOR FEEDERS, BRANCH CIRCUITS, ETC.

U. DESIGN OF TEMPORARY POWER FOR CONSTRUCTION SHALL BE THE CONTRACTOR'S

RESPONSIBILITY. REMOVE TEMPORARY POWER PRIOR TO COMPLETION OF PROJECT.

V. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL CONDUIT TRENCHING WITH OTHER

DISCIPLINES TO AVOID CONFLICT.

W. MINIMUM SIZE FOR EXTERIOR BELOW GRADE CONDUIT SHALL BE 1-1/4", U.O.N.

X. COMMUNICATIONS PATHWAYS, MANHOLES AND POLES ARE SHOWN

DIAGRAMMATICALLY. LOCATIONS ARE APPROXIMATE UNLESS SPECIFICALLY

DIMENSIONED. FIELD COORDINATE ALL WORK.

Y. CONSTRUCTION DETAILS SHOW TYPICAL INSTALLATION, UON, AND APPLY TO ALL

COMMUNICATIONS WORK INCLUDED IN THE SUMMARY OF WORK FOR THIS PACKAGE

EVEN THOUGH NOT SPECIFICALLY REFERENCED ON THE PLAN DRAWINGS.

Z. INSTALL PULL STRINGS IN ALL CONDUITS AT THE TIME OF CONDUIT AND CABLE

INSTALLATION.

AA. CONTRACTOR SHALL REPLACE ALL PAVING, LANDSCAPING, IRRIGATION, LIGHTING,

ELECTRICAL WIRING, ETC. REMOVED AND/OR DAMAGED DURING THE COURSE OF

THEIR WORK.

AB. CONTRACTOR SHALL DEVELOP AND SUBMIT TRAFFIC ROUTING & CONTROL PLANS FOR

APPROVAL BY ALAMEDA HEALTH SYSTEM (ATTN: NILESH LAL 510-895-4556) AND

PROVIDE TRAFFIC CONTROL PER APPROVED PLANS DURING CONSTRUCTION.

AC. CONTRACTOR SHALL DEVELOP AND SUBMIT A WORK PLAN THAT INCLUDES BUT NOT

LIMITED TO CONSTRUCTION PHASING & SEQUENCING, STAGING AREA, TRENCHING

PLAN & SAFETY PROCEDURES.

AD. DRAWINGS AND SPECIFICATIONS COMPLIMENT EACH OTHER. REQUIREMENT BY EITHER

INFERS REQUIREMENT FOR BOTH.

AE. REFER TO DIVISION 26 SPECIFICATIONS FOR ADDITIONAL ELECTRICAL REQUIREMENTS.

AF. REFER TO DIVISION 27 SPECIFICATIONS FOR ADDITIONAL COMMUNICATIONS

REQUIREMENTS.

Equipment

2-POST EQUIPMENT RACK

DOUBLE-SIDED VERTICAL WIRE MANAGEMENT

Abbreviations

EXISTING(E)

NEW(N)

AMPERES, AMBERA

ABOVE FINISHED CEILINGAFC

AUTHORITY HAVING JURISDICTIONAHJ

AMERICAN NATIONAL STANDARDS INSTITUTEANSI

ABOVE RAISED FLOORARF

AMERICAN WIRE GAUGEAWG

CONDUIT, CLOSE, CONTROLC

CABLECA

CATEGORYCAT

CEILINGCLG

COMMUNICATIONCOM

COORDINATECOORD

COPPERCU

DIAMETERDIA

DIMENSIONDIM

DIVISIONDIV

DETAILDTL

DRAWINGDWG

EMERGENCYE

ELECTRICAL METALLIC TUBINGEMT

FOOT, FEETFT

GROUNDG, GND

INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERSIEEE

INCH, INCHESIN

KILOVOLTKV

KILOVOLT AMPERESKVA

KILOWATTKW

LIGHT EMITTING DIODELED

NEUTRALN

NATIONAL ELECTRIC CODENEC

NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATIONNEMA

NATIONAL ELECTRIC SAFETY CODENESC

NOT TO SCALENTS

PHASEPH

REQUEST FOR INFORMATIONRFI

TYPICALTYP

UNDERWRITERS LABORATORIESUL

UNLESS OTHERWISE NOTEDUON

VOLTS, VOLTAGEV

Connections / Equipment

JUNCTION BOX

JJ

OR

General

EXISTING WORK

NEW WORK

KEYED NOTE

1

SECTION NUMBER AND SHEET LOCATION

XXX

A

Miscellaneous

BRANCH CIRCUIT WIRING. ARROW INDICATES HOME RUN TO PANEL WITH

CIRCUITS AS NOTED. WIRE SIZE IS #12 AWG MINIMUM UNLESS NOTED

OTHERWISE. SHORT TICK MARKS INDICATE PHASE CONDUCTORS. LONG

TICK MARKS INDICATE NEUTRAL CONDUCTORS. A SINGLE CURVED TICK

MARK INDICATES INSULATED GREEN GROUND CONDUCTOR. SECOND

CURVED TICK MARK INDICATES "ISOLATED GROUND" (GREEN INSULATION

WITH YELLOW STRIPE) CONDUCTOR.

B-27,29,31.

#10

BRANCH PANEL

Raceways

CONDUIT CONCEALED IN WALL OR CEILING SPACE

CONDUIT ROUTED BELOW FLOOR / GRADE

CONDUIT ELLED DOWN

CONDUIT ELLED UP

CONDUIT/WIRING CONTINUATION

CONDUIT/WIRING STUBBED OUT WITH END CAP OR INSULATED PLASTIC

BUSHING

Switches and Receptacles

DUPLEX RECEPTACLE (MULTIPLE LETTERS INDICATE MULTIPLE OPTIONS)

A = ABOVE COUNTER

E = EMERGENCY

G = GROUND FAULT CIRCUIT INTERRUPTER

L = ISOLATED GROUND

R1 = HALF SWITCHED BY OCCUPANCY SENSOR RELAY

R2 = FULLY SWITCHED BY OCCUPANCY SENSOR RELAY

W = WEATHERPROOF CONTINUOUS USE COVER, GFCI PROTECTED,

WITH WEATHER-RESISTANT RECEPTACLE

DOUBLE DUPLEX RECEPTACLE. SEE LETTER CODE LIST AT DUPLEX

RECEPTACLE FOR OPTIONS

SYMBOL LIST

NOTE: This is a standard symbol list and not all items listed may be used.

T0.1

SYMBOL LIST &

GENERAL NOTES

REVISIONS

DATE

JOB NO.

CHECKED BY

DRAWN BY

SHEET NUMBER

SHEET TITLE

135 Main Street

Suite 400

San Francisco, CA 94105

TEL 415.489.7240

FAX 415.489.7289

www.interfaceengineering.com

Jason Nguyen

Westley Anastasio

2016-0272

11-02-2016

AL

AM

ED

A C

OU

NT

Y F

AIR

MO

NT

C

AM

PU

S

BH

CS

D

AT

A U

PG

RA

DE

15430 F

OO

TH

IL

L B

LV

D

SA

N L

EA

ND

RO

, C

A 94575

CONTACT

PROJECT

135 Main Street

Suite 400

San Francisco, CA 94105

TEL 415.489.7240

FAX 415.489.7289

www.interfaceengineering.com

Jason Nguyen

2016-0272

Page 3: ALAMEDA COUNTY FAIRMONT CAMPUS BHCS DATA UPGRADE - ACGOV.org · this project entails the upgrade of communication pathways to fiber cabling for key ... approval by alameda health

GENERAL SHEET NOTES

A. CONTRACTOR TO VISIT SITE AND VERIFY THE EXACT CONDITIONS RELATING TO

SITE WORK AND OBTAIN SUCH INFORMATION AS MAY BE NECESSARY TO

PRESENT AN INTELLIGENT AND CONCLUSIVE BID. NO ALLOWANCE WILL BE

MADE FOR ANY EXTRA EXPENSE DUE TO FAILURE TO MAKE SUCH A VISIT.

VERIFY ALL ACTUAL FIELD CONDITIONS.

B. ALL SITE WORK IS SHOWN DIAGRAMMATICALLY. CONTRACTOR TO VERIFY

EXACT DISTANCES AND ROUTING IN FIELD. CONTRACTOR IS RESPONSIBLE

FOR LOCATING AND COORDINATING EXISTING UTILITIES LINES PRIOR TO THE

START OF CONSTRUCTION.

C. THE NATURE OF THE WORK REQUIRES DISTURBANCES OF EXISTING SITE

SURFACE INSTALLATIONS BY TRENCHING. CONTRACTOR SHALL CONSULT WITH

OWNER'S REPRESENTATIVE A MINIMUM OF SEVEN DAYS PRIOR TO OPENING

ANY TRENCH OR DOING EXCAVATION. TAKE PROPER STEPS TO PROTECT

EXISTING PLANTINGS IN THE AREA TO BE DISTURBED. CONTRACTOR SHALL

REPLACE IN KIND ANY DAMAGED SOD, PLANTS OR IRRIGATION LINES.

D. THE ROUTING OF TRENCHING IS GENERALLY SHOWN ON THE DRAWINGS,

WHICH WERE PREPARED WITHOUT INDICATION OF EXISTING VEGETATION.

CONTRACTOR, CONSULTING WITH THE OWNER'S REPRESENTATIVE WHERE

NECESSARY, SHALL ROUTE TRENCHES TO AVOID TREES, AND WHERE

POSSIBLE, SHRUBBERY, AND OTHER LANDSCAPING. THE ROUTE OF TRENCHES

SHALL BE STAKED, AND SUFFICIENT TIME ALLOWED PRIOR TO EXCAVATION

FOR OWNER TO VERIFY AND APPROVE ROUTE.

E. CONTRACTOR SHALL PLAN HIS OPERATION TO AVOID DAMAGE TO ADJACENT

PLANTINGS. DO NOT DISTURB EXISTING EARTH GRADES WITHIN THE DRIP LINE

OF EXISTING TREES TO REMAIN.

F. CONTRACTOR SHALL PROVIDE ADD ALTERNATE FOR ALL NEW WORK

ASSOCIATED WITH TRAILER #1.

SHEET KEYNOTES

1 PROVIDE (2) NEW 4" UNDERGROUND CONDUITS. ROUTING TO FOLLOW EXISTING

UNDERGROUND COMMUNICATIONS CONDUIT PATHWAY. SEE 3/T3.1 FOR

TRENCHING DETAIL AND 2/E4.1 FOR CABLING QUANTITIES.

2 PROVIDE NEW OVERHEAD AERIAL FIBER CABLING WITH MESSENGER CABLE.

MOUNT CABLING TO EXISTING POLES WITH A MINIMUM 3' SEPARATION BELOW

POWER LINES. REFER TO DETAIL 2/T3.1 FOR CABLING QUANTITIES.

3 PROVIDE (1) NEW 4" UNDERGROUND CONDUIT. ROUTING TO FOLLOW EXISTING

UNDERGROUND COMMUNICATIONS CONDUIT PATHWAY. SEE 3/T4.1 FOR

TRENCHING DETAIL AND 2/T4.1 FOR CABLING QUANTITIES.

4 EXISTING COMMUNICATIONS MANHOLE, TYPICAL.

5 EXISTING POWER/TELEPHONE POLE, TYPICAL.

6 EXISTING UNDERGROUND COMMUNICATIONS PATHWAY. PROVIDE NEW 2"

INNERDUCT, PULL TAPE AND PULL STRING BETWEEN SOBERING BUILDING AND

ADMIN BUILDING. APPROXIMATELY 600 FEET.

7 SEE DRAWING 2/T2.1 FOR ENLARGED TELE/DATA ROOM.

8 ADD ALTERNATE: PROVIDE NEW OVERHEAD AERIAL FIBER CABLING. MOUNT

CABLING TO EXISTING POLES WITH A MINIMUM 3' SEPARATION BELOW POWER

LINES. REFER TO DETAIL 2/T3.1 FOR CABLING QUANTITIES.

9 ADD ALTERNATE: CABLING TO TERMINATE IN NEW FIBER ENCLOSURE AT

EXISTING IDF LOCATION IN TRAILER #1. SEE PHOTO 5/T3.2.

10 EXISTING UNDERGROUND UTILITY TUNNEL.

11 CABLING TO TERMINATE IN NEW FIBER ENCLOSURE AT EXISTING IDF LOCATION

IN SOBERING BUILDING. SEE PHOTOS 1/T3.2 & 6/T3.2, RACK ELEVATION 4/T3.1

AND ENLARGED PLAN 2/T2.1.

12 CABLING TO TERMINATE IN NEW FIBER ENCLOSURE AT EXISTING IDF LOCATION

IN DETOX BUILDING. SEE PHOTO 2/T3.2.

13 CABLING TO TERMINATE IN NEW FIBER ENCLOSURE AT EXISTING IDF LOCATION

IN EDEN BUILDING. SEE PHOTO 3/T3.2.

14 CABLING TO TERMINATE IN NEW FIBER ENCLOSURE AT EXISTING IDF LOCATION

IN TRAILER #3. SEE PHOTO 4/T3.2.

15 SEE 7/T3.2 FOR EXISTING POWER/TELE POLE DETAIL.

T1.1

SITE PLAN-TECHNOLOGY

REVISIONS

DATE

JOB NO.

CHECKED BY

DRAWN BY

SHEET NUMBER

SHEET TITLE

135 Main Street

Suite 400

San Francisco, CA 94105

TEL 415.489.7240

FAX 415.489.7289

www.interfaceengineering.com

Jason Nguyen

Westley Anastasio

2016-0272

11-02-2016

AL

AM

ED

A C

OU

NT

Y F

AIR

MO

NT

C

AM

PU

S

BH

CS

D

AT

A U

PG

RA

DE

15430 F

OO

TH

IL

L B

LV

D

SA

N L

EA

ND

RO

, C

A 94575

CONTACT

PROJECT

135 Main Street

Suite 400

San Francisco, CA 94105

TEL 415.489.7240

FAX 415.489.7289

www.interfaceengineering.com

Jason Nguyen

2016-0272

NO SCALE

1 SITE PLAN - TECHNOLOGY

Page 4: ALAMEDA COUNTY FAIRMONT CAMPUS BHCS DATA UPGRADE - ACGOV.org · this project entails the upgrade of communication pathways to fiber cabling for key ... approval by alameda health

FIREHYDRANT

FIRE VALVE

ENTRY

INTAKE/CONTROL

HC SAFETY

SAFETY #1 SAFETY #2 SAFETY #3

TEL/DATA

SLEEPING AREA #1

STORAGEELECTRICAL

WATER HEATER

REPORT PREP

JAN. CLOSETSLEEPING AREA #2

OFFICEBREAK ROOM

SLEEPING AREA #3

CORRIDOR

STORAGE

RESTROOM

OFFICE

RESTROOM

CORRIDOR

CORRIDOR

2

T3.1

TEL/DATA

SLEEPING AREA #1

STORAGEELECTRICAL

WATER HEATER

REPORT PREP

JAN. CLOSET

(E) PANEL 'ELS'

E

1

2

3

(E)

5

4

E

1

6

ELS-8,10.

7

8.

10.

GENERAL SHEET NOTES

A. FIELD VERIFY EXISTING CONDITIONS PRIOR TO START OF NEW WORK.

SHEET KEYNOTES

1 PROVIDE (2) NEW QUAD RECEPTACLES. PROVIDE CIRCUIT LABEL AND RED

COVER PLATE TO INDICATE EMERGENCY.

2 PROVIDE NEW 3/4" FIRE RATED PLYWOOD BACKBOARD. REMOVE AND REINSTALL

EXISTING ENTRANCE TERMINAL, 110 BLOCK AND NETWORK DEVICE ON NEW

BACKBOARD. SEE ALSO 6/T3.2 FOR PHOTO OF EXISTING WALL EQUIPMENT.

3 EXISTING 2-POST EQUIPMENT RACK WITH BUILT IN VERTICAL WIRE

MANAGEMENT. SEE DETAIL 4/T3.1 FOR RACK ELEVATION.

4 PROVIDE NEW 12" LADDER RACK.

5 EXISTING TO REMAIN.

6 EXISTING GROUND BUS BAR TO REMAIN.

7 CONNECT COMPLETE TO EXISTING SPARE 20A/1PH BREAKERS IN THE EXISTING

PANEL "ELS."

T2.1

SOBERING BUILDINGPLAN, ENLARGED PLAN &PANEL SCHEDULE- TECHNOLOGY

REVISIONS

DATE

JOB NO.

CHECKED BY

DRAWN BY

SHEET NUMBER

SHEET TITLE

135 Main Street

Suite 400

San Francisco, CA 94105

TEL 415.489.7240

FAX 415.489.7289

www.interfaceengineering.com

Jason Nguyen

Westley Anastasio

2016-0272

11-02-2016

AL

AM

ED

A C

OU

NT

Y F

AIR

MO

NT

C

AM

PU

S

BH

CS

D

AT

A U

PG

RA

DE

15430 F

OO

TH

IL

L B

LV

D

SA

N L

EA

ND

RO

, C

A 94575

CONTACT

PROJECT

135 Main Street

Suite 400

San Francisco, CA 94105

TEL 415.489.7240

FAX 415.489.7289

www.interfaceengineering.com

Jason Nguyen

2016-0272

0 16' 32'

SCALE: 1/16"=1'-0"

8'

1 SOBERING BUILDING PLAN - ELECTRICAL

0 8' 12'

SCALE: 3/16"=1'-0"

4'

2 ENLARGED PLAN - ELECTRICAL & TELE/DATA ROOM

2015-0007

Ckt. C.B. C.B. Ckt.

No.

Description / Location

A/Pole Note Ph. Note A/Pole

Description / Location

No.

1 EXISTING LOAD 500 C 20/1 A 20/1 200 C EXISTING LOAD 2

3 EXISTING LOAD 400 G 20/1 B 20/1 400 R EXISTING LOAD 4

5 EXISTING LOAD 200 G 20/1 C 20/1 800 K EXISTING LOAD 6

7 EXISTING LOAD 400 G 20/1 A 1 20/1 360 R RECEP - TEL/DATA 8

9 EXISTING LOAD 400 G 20/1 B 1 20/1 360 R SPARE 10

11 EXISTING LOAD 400 G 20/1 C 20/1 SPARE 12

13 EXISTING LOAD 800 G 20/1 A 20/1 SPARE 14

15 EXISTING LOAD 800 G 20/1 B 20/1 SPARE 16

17 EXISTING LOAD 800 G 20/1 C 20/1 SPARE 18

19 SPACE A SPACE 20

21 SPACE B SPACE 22

23 SPACE C SPACE 24

Total Connected Load: Ph. A

2,260

VA 19

Amps

Panel Connected Load: 6.8 KVA 18.9

Amps

Total Connected Load: Ph. B

2,360

VA 20

Amps

Sub-Fed Connected Load: 0.0 KVA 0.0

Amps

Total Connected Load: Ph. C

2,200

VA 18

Amps

Total Demand Load: 7.0 KVA 19.4

Amps

Notes: Accessories:

1. LOADS SHOWN INDICATE NEW LOADS ONLY.

Provide Feed-Thru Lugs

2.

3.

4.

5.

(E) Panel 'ELS'

120/208V, 3 Ph., 4 W.; 100A Bus with 30A Main Circuit Breaker Surface Mounted Panelboard with a

minimum Available Fault rating of 10834A RMS

Load Load

(VA)|Type (VA)|Type

Page 5: ALAMEDA COUNTY FAIRMONT CAMPUS BHCS DATA UPGRADE - ACGOV.org · this project entails the upgrade of communication pathways to fiber cabling for key ... approval by alameda health

A.H.S.

ADMIN

VILLA

SHORT

STAY

SOBERING

DETOX

BHCS

EDEN

TRAILER #3

1 PROVIDE (4) 24-STRAND SINGLE MODE OUTDOOR FIBER

CABLE IN 1-1/2" FIBER INNERDUCT. APPROXIMATELY 700

FEET. SUPPORT INNERDUCT RUN INSIDE UNDERGROUND

UTILITY TUNNEL.

2 PROVIDE 24-STRAND SINGLE MODE OUTDOOR RATED

AERIAL FIBER CABLE. APPROXIMATELY 800 FEET CABLE

RUN FROM FIBER BOX TO TRAILERS.

3 PROVIDE OUTDOOR RATED LOCKABLE FIBER SPLICE BOX

ON EXISTING POLE.

4 PROVIDE 24-STRAND SINGLE MODE OUTDOOR RATED

FIBER CABLE IN 1-1/2" INNERDUCT. APPROXIMATELY 800

FEET CABLE RUN FROM SOBERING TO FIBER BOX ON

POLE. SUPPORT INNERDUCT RUN INSIDE UNDERGROUND

UTILITY TUNNEL. SINGLE CONTINUOUS FIBER RUN FROM

SOBERING TO SPLICE BOX.

1 NEW OVERHEAD/AERIAL PATHWAY ON EXISTING

POLES

2 EXISTING MANHOLE/VAULT

TRAILER #1

6

5

4

3

3

3 EXISTING UNDERGROUND COMMUNICATIONS

PATHWAY

4 NEW (2)-4" UNDERGROUND CONDUIT RUN

ALONGSIDE EXISTING CONDUIT TO EXISTING

UTILITY TUNNEL. APPROXIMATELY 250 FEET.

5 NEW (2)-4" UNDERGROUND CONDUIT IN (E)

TUNNEL AND BEYOND TO (E) APPROXIMATELY

300 FEET.

6 NEW (1)-4" UNDERGROUND CONDUIT.

APPROXIMATELY 100 FEET.

2

1

TYP.

NEW 2U HORIZONTAL

WIRE MANAGER

NEW 4U FIBER

ENCLOSURE

EXISTING 48-PORT PATCH

PANEL TO REMAIN.

SPACE RESERVED FOR

OWNER FURNISHED

EQUIPMENT

NOTE: ENTIRE FIBER RUN TO TRAILER #1 TO BE PRICED AS

SEPARATE ADD ALTERNATE.

NOTE: ENTIRE FIBER RUN FOR TRAILER #1 TO BE PRICED AS

SEPARATE ADD ALTERNATE.

SOBERING

DETOX

BHCS

EDEN

TRAILER #1

4

2

3

TRAILER #3

1

1

4

A. ALL FIBER CABLING TO TERMINATE ON LC TYPE CONNECTORS

AT INDICATED IDF ROOMS. SEE ALSO SPECIFICATION 27 13 00.

T3.1

DETAILS- TECHNOLOGY

REVISIONS

DATE

JOB NO.

CHECKED BY

DRAWN BY

SHEET NUMBER

SHEET TITLE

135 Main Street

Suite 400

San Francisco, CA 94105

TEL 415.489.7240

FAX 415.489.7289

www.interfaceengineering.com

Jason Nguyen

Westley Anastasio

2016-0272

11-02-2016

AL

AM

ED

A C

OU

NT

Y F

AIR

MO

NT

C

AM

PU

S

BH

CS

D

AT

A U

PG

RA

DE

15430 F

OO

TH

IL

L B

LV

D

SA

N L

EA

ND

RO

, C

A 94575

CONTACT

PROJECT

135 Main Street

Suite 400

San Francisco, CA 94105

TEL 415.489.7240

FAX 415.489.7289

www.interfaceengineering.com

Jason Nguyen

2016-0272

NO SCALENO SCALE

NO SCALE NO SCALE

Page 6: ALAMEDA COUNTY FAIRMONT CAMPUS BHCS DATA UPGRADE - ACGOV.org · this project entails the upgrade of communication pathways to fiber cabling for key ... approval by alameda health

T3.2

PHOTOS- TECHNOLOGY

REVISIONS

DATE

JOB NO.

CHECKED BY

DRAWN BY

SHEET NUMBER

SHEET TITLE

135 Main Street

Suite 400

San Francisco, CA 94105

TEL 415.489.7240

FAX 415.489.7289

www.interfaceengineering.com

Jason Nguyen

Westley Anastasio

2016-0272

11-02-2016

AL

AM

ED

A C

OU

NT

Y F

AIR

MO

NT

C

AM

PU

S

BH

CS

D

AT

A U

PG

RA

DE

15430 F

OO

TH

IL

L B

LV

D

SA

N L

EA

ND

RO

, C

A 94575

CONTACT

PROJECT

135 Main Street

Suite 400

San Francisco, CA 94105

TEL 415.489.7240

FAX 415.489.7289

www.interfaceengineering.com

Jason Nguyen

2016-0272

NO SCALE NO SCALE NO SCALE NO SCALE

NO SCALE NO SCALE NO SCALE