alcopole - conical poles with consoles

6
B N L M D C H A G J I A F E Standard Lighting Column Article number (Buried) ABB.001.040 ABB.002.050 ABB.003.050 ABB.004.050 ABB.005.050 ABB.006.060 Article number (Flanged) AFB.001.040 AFB.002.050 AFB.003.050 AFB.004.050 AFB.005.050 AFB.006.060 Surface area of column / m² 1.74 2.05 2.05 2.12 2.12 2.51 Dimensions A Base 114 114 114 122 122 122 B Top 60 60 60 60 60 60 C Mass 12.5 14.5 14.4 17.5 17.3 20.5 D Wall thickness 2.5 2.5 2.5 3 3 3 E Light point height 4000 5000 5000 5000 5000 6000 F Groundrooth protection 800 800 800 800 800 1000 G Access door position 420 420 420 420 420 420 H Access door dimensions 400x85 400x85 400x85 400x85 400x85 400x85 I Cable entry dimensions 150x50 150x50 150x50 150x50 150x50 150x50 J Cable entry position 500 500 500 500 500 500 K Max. dimensions of cutout 80x60x300 80x60x300 80x60x300 80x65x300 80x65x300 80x65x300 L Bracket Lenght 750 750 750 750 750 750 M Radius 300 300 300 300 300 300 N Angle 15° 15° Column with baseplate Baseplate Article Number 600 600 600 601 601 601 Surface area of column 1.49 1.80 1.80 1.86 1.86 2.19 Ac Value in M 2 Mass / kg 10 8 8 10 10 5 136 km / hour 0.09 0.05 0.05 0.11 0.11 0.06 161 km / hour 0.05 0.02 0.02 0.06 0.06 0.02 184 km / hour 0.03 - - 0.03 0.03 - 204 km / hour 0.01 - - 0.01 0.01 - Lighting Point Height 4000 5000 5000 5000 5000 6000 Conical Poles With Consoles CONICAL POLES WITH CONSOLES Technical Data

Upload: heper-moonlight

Post on 18-Mar-2016

214 views

Category:

Documents


0 download

DESCRIPTION

Since 2009, the core activity of ALCOPOLE is the production of high quality aluminum poles.

TRANSCRIPT

Page 1: Alcopole - Conical Poles with Consoles

34

B

N

L

M

D

C

H

A

G

J

I

A

F

E

Standard Lighting Column

Article number (Buried) ABB.001.040 ABB.002.050 ABB.003.050 ABB.004.050 ABB.005.050 ABB.006.060 ABB.007.060 ABB.008.060 ABB.009.060 ABB.010.080 ABB.011.080 ABB.012.080 ABB.013.080 ABB.014.080

Article number (Flanged) AFB.001.040 AFB.002.050 AFB.003.050 AFB.004.050 AFB.005.050 AFB.006.060 AFB.007.060 AFB.008.060 AFB.009.060 AFB.010.080 AFB.011.080 AFB.012.080 AFB.013.080 AFB.014.080

Surface area of column / m² 1.74 2.05 2.05 2.12 2.12 2.51 2.51 2.72 2.72 4.03 4.03 4.21 4.32 4.32

Dimensions

A Base 114 114 114 122 122 122 122 135 135 165 165 165 165 165

B Top 60 60 60 60 60 60 60 60 60 60 60 70 76 76

C Mass 12.5 14.5 14.4 17.5 17.3 20.5 20.3 22.8 22.6 34.6 29.5 35.5 36.4 36.6

D Wall thickness 2.5 2.5 2.5 3 3 3 3 3 3 3 3 3 3 3

E Light point height 4000 5000 5000 5000 5000 6000 6000 6000 6000 8000 8000 8000 8000 8000

F Groundrooth protection 800 800 800 800 800 1000 1000 1000 1000 1200 1200 1200 1200 1200

G Access door position 420 420 420 420 420 420 420 420 420 420 420 420 420 420

H Access door dimensions 400x85 400x85 400x85 400x85 400x85 400x85 400x85 400x85 400x85 500x100 500x100 500x100 500x100 500x100

I Cable entry dimensions 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50

J Cable entry position 500 500 500 500 500 500 500 500 500 500 500 500 500 500

K Max. dimensions of cutout 80x60x300 80x60x300 80x60x300 80x65x300 80x65x300 80x65x300 80x65x300 80x90x300 80x90x300 95x110x400 95x110x400 95x110x400 95x110x400 95x110x400

L Bracket Lenght 750 750 750 750 750 750 750 750 750 750 750 750 750 750

M Radius 300 300 300 300 300 300 300 300 300 300 300 350 380 380

N Angle 5° 5° 15° 5° 15° 5° 15° 5° 15° 5° 15° 5° 5° 15°

Column with baseplate

Baseplate Article Number 600 600 600 601 601 601 601 602 602 604 604 604 604 604

Surface area of column 1.49 1.80 1.80 1.86 1.86 2.19 2.19 3.37 3.37 3.54 3.54 3.70 3.80 3.80

Ac Value in M2

Mass / kg 10 8 8 10 10 5 8 8 10 8 8 8 10 12

136 km / hour 0.09 0.05 0.05 0.11 0.11 0.06 0.06 0.17 0.17 0.19 0.19 0.18 0.18 0.18

161 km / hour 0.05 0.02 0.02 0.06 0.06 0.02 0.02 0.09 0.09 0.11 0.11 0.10 0.10 0.10

184 km / hour 0.03 - - 0.03 0.03 - - 0.06 0.06 0.07 0.07 0.07 0.07 0.07

204 km / hour 0.01 - - 0.01 0.01 - - 0.03 0.03 0.04 0.04 0.04 0.03 0.04

Lighting Point Height 4000 5000 5000 5000 5000 6000 6000 6000 6000 8000 8000 8000 8000 8000

Conical PolesWith Consoles

CONICAL POLES WITH CONSOLESTechnical Data

Page 2: Alcopole - Conical Poles with Consoles

35

Standard Lighting Column

Article number (Buried) ABB.001.040 ABB.002.050 ABB.003.050 ABB.004.050 ABB.005.050 ABB.006.060 ABB.007.060 ABB.008.060 ABB.009.060 ABB.010.080 ABB.011.080 ABB.012.080 ABB.013.080 ABB.014.080

Article number (Flanged) AFB.001.040 AFB.002.050 AFB.003.050 AFB.004.050 AFB.005.050 AFB.006.060 AFB.007.060 AFB.008.060 AFB.009.060 AFB.010.080 AFB.011.080 AFB.012.080 AFB.013.080 AFB.014.080

Surface area of column / m² 1.74 2.05 2.05 2.12 2.12 2.51 2.51 2.72 2.72 4.03 4.03 4.21 4.32 4.32

Dimensions

A Base 114 114 114 122 122 122 122 135 135 165 165 165 165 165

B Top 60 60 60 60 60 60 60 60 60 60 60 70 76 76

C Mass 12.5 14.5 14.4 17.5 17.3 20.5 20.3 22.8 22.6 34.6 29.5 35.5 36.4 36.6

D Wall thickness 2.5 2.5 2.5 3 3 3 3 3 3 3 3 3 3 3

E Light point height 4000 5000 5000 5000 5000 6000 6000 6000 6000 8000 8000 8000 8000 8000

F Groundrooth protection 800 800 800 800 800 1000 1000 1000 1000 1200 1200 1200 1200 1200

G Access door position 420 420 420 420 420 420 420 420 420 420 420 420 420 420

H Access door dimensions 400x85 400x85 400x85 400x85 400x85 400x85 400x85 400x85 400x85 500x100 500x100 500x100 500x100 500x100

I Cable entry dimensions 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50

J Cable entry position 500 500 500 500 500 500 500 500 500 500 500 500 500 500

K Max. dimensions of cutout 80x60x300 80x60x300 80x60x300 80x65x300 80x65x300 80x65x300 80x65x300 80x90x300 80x90x300 95x110x400 95x110x400 95x110x400 95x110x400 95x110x400

L Bracket Lenght 750 750 750 750 750 750 750 750 750 750 750 750 750 750

M Radius 300 300 300 300 300 300 300 300 300 300 300 350 380 380

N Angle 5° 5° 15° 5° 15° 5° 15° 5° 15° 5° 15° 5° 5° 15°

Column with baseplate

Baseplate Article Number 600 600 600 601 601 601 601 602 602 604 604 604 604 604

Surface area of column 1.49 1.80 1.80 1.86 1.86 2.19 2.19 3.37 3.37 3.54 3.54 3.70 3.80 3.80

Ac Value in M2

Mass / kg 10 8 8 10 10 5 8 8 10 8 8 8 10 12

136 km / hour 0.09 0.05 0.05 0.11 0.11 0.06 0.06 0.17 0.17 0.19 0.19 0.18 0.18 0.18

161 km / hour 0.05 0.02 0.02 0.06 0.06 0.02 0.02 0.09 0.09 0.11 0.11 0.10 0.10 0.10

184 km / hour 0.03 - - 0.03 0.03 - - 0.06 0.06 0.07 0.07 0.07 0.07 0.07

204 km / hour 0.01 - - 0.01 0.01 - - 0.03 0.03 0.04 0.04 0.04 0.03 0.04

Lighting Point Height 4000 5000 5000 5000 5000 6000 6000 6000 6000 8000 8000 8000 8000 8000

Page 3: Alcopole - Conical Poles with Consoles

36

Standard Lighting Column

Article number (Buried) ABB.015.080 ABB.016.080 ABB.017.080 ABB.018.080 ABB.019.080 ABB.020.080 ABB.021.100 ABB.022.100 ABB.023.100 ABB.024.100 ABB.025.100 ABB.026.100 ABB.027.100 ABB.028.120

Article number (Flanged) AFB.015.080 AFB.016.080 AFB.017.080 AFB.018.080 AFB.019.080 AFB.020.080 AFB.021.100 AFB.022.100 AFB.023.100 AFB.024.100 AFB.025.100 AFB.026.100 AFB.027.100 AFB.028.120

Surface area of column / m² 4.42 4.42 4.76 4.76 4.76 5.23 5.58 5.58 5.81 5.81 6.10 6.10 6.38 7.48

Dimensions

A Base 165 165 180 180 190 200 180 180 180 180 190 190 200 200

B Top 70 70 76 76 76 76 76 76 76 76 76 76 76 76

C Mass 36.7 36.4 49.6 49.6 54.1 69.5 61.7 61.7 62.7 62.3 68.2 67.8 86.4 101.1

D Wall thickness 3 3 4 4 4 5 4 4 4 4 4 4 5 5

E Light point height 8000 8000 8000 8000 8000 8000 10000 10000 10000 10000 10000 10000 10000 12000

F Groundrooth protection 1200 1200 1200 1200 1200 1200 1500 1500 1500 1500 1500 1500 1500 1700

G Access door position 420 420 420 420 420 420 420 420 420 420 420 420 420 420

H Access door dimensions 500x100 500x100 500x100 500x100 600x115 600x115 500x100 500x100 500x100 500x100 600x115 600x115 600x115 600x115

I Cable entry dimensions 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50

J Cable entry position 500 500 500 500 500 500 500 500 500 500 500 500 500 500

K Max. dimensions of cutout 95x110x400 95x110x400 95x130x400 95x130x400 110x135x485 110x145x485 95x130x400 95x130x400 95x130x400 95x130x400 110x135x485 110x135x485 110x145x485 110x145x485

L Bracket Lenght 1250 1250 1250 1250 750 1250 750 750 1250 1250 1250 1250 1250 1250

M Radius 350 350 380 380 380 380 380 380 380 380 380 380 380 380

N Angle 5° 15° 5° 15° 5° 5° 5° 15° 5° 15° 5° 15° 5° 5°

Column with baseplate

Baseplate Article Number 604 604 605 605 606 607 605 605 605 605 606 606 607 607

Surface area of column 3.91 3.91 4.21 4.21 4.19 4.63 4.90 4.90 5.12 5.12 5.39 5.39 5.63 6.63

Ac Value in M2

Mass / kg 8 10 12 12 20 20 12 12 12 12 12 12 15 12

136 km / hour 0.11 0.12 0.30 0.30 0.45 0.59 0.25 0.25 0.17 0.17 0.19 0.19 0.42 0.19

161 km / hour 0.05 0.05 0.19 0.19 0.30 0.39 0.15 0.15 0.09 0.09 0.11 0.11 0.27 0.16

184 km / hour 0.02 0.03 0.13 0.13 0.21 0.28 0.09 0.09 0.04 0.04 0.05 0.05 0.17 0.07

204 km / hour - 0.01 0.08 0.08 0.14 0.20 0.04 0.04 0.01 0.01 0.01 0.01 0.10 0.02

Lighting Point Height 8000 8000 8000 8000 8000 8000 10000 10000 10000 10000 10000 10000 10000 12000

CONICAL POLES WITH CONSOLESTechnical Data

Page 4: Alcopole - Conical Poles with Consoles

37

Standard Lighting Column

Article number (Buried) ABB.015.080 ABB.016.080 ABB.017.080 ABB.018.080 ABB.019.080 ABB.020.080 ABB.021.100 ABB.022.100 ABB.023.100 ABB.024.100 ABB.025.100 ABB.026.100 ABB.027.100 ABB.028.120

Article number (Flanged) AFB.015.080 AFB.016.080 AFB.017.080 AFB.018.080 AFB.019.080 AFB.020.080 AFB.021.100 AFB.022.100 AFB.023.100 AFB.024.100 AFB.025.100 AFB.026.100 AFB.027.100 AFB.028.120

Surface area of column / m² 4.42 4.42 4.76 4.76 4.76 5.23 5.58 5.58 5.81 5.81 6.10 6.10 6.38 7.48

Dimensions

A Base 165 165 180 180 190 200 180 180 180 180 190 190 200 200

B Top 70 70 76 76 76 76 76 76 76 76 76 76 76 76

C Mass 36.7 36.4 49.6 49.6 54.1 69.5 61.7 61.7 62.7 62.3 68.2 67.8 86.4 101.1

D Wall thickness 3 3 4 4 4 5 4 4 4 4 4 4 5 5

E Light point height 8000 8000 8000 8000 8000 8000 10000 10000 10000 10000 10000 10000 10000 12000

F Groundrooth protection 1200 1200 1200 1200 1200 1200 1500 1500 1500 1500 1500 1500 1500 1700

G Access door position 420 420 420 420 420 420 420 420 420 420 420 420 420 420

H Access door dimensions 500x100 500x100 500x100 500x100 600x115 600x115 500x100 500x100 500x100 500x100 600x115 600x115 600x115 600x115

I Cable entry dimensions 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50 150x50

J Cable entry position 500 500 500 500 500 500 500 500 500 500 500 500 500 500

K Max. dimensions of cutout 95x110x400 95x110x400 95x130x400 95x130x400 110x135x485 110x145x485 95x130x400 95x130x400 95x130x400 95x130x400 110x135x485 110x135x485 110x145x485 110x145x485

L Bracket Lenght 1250 1250 1250 1250 750 1250 750 750 1250 1250 1250 1250 1250 1250

M Radius 350 350 380 380 380 380 380 380 380 380 380 380 380 380

N Angle 5° 15° 5° 15° 5° 5° 5° 15° 5° 15° 5° 15° 5° 5°

Column with baseplate

Baseplate Article Number 604 604 605 605 606 607 605 605 605 605 606 606 607 607

Surface area of column 3.91 3.91 4.21 4.21 4.19 4.63 4.90 4.90 5.12 5.12 5.39 5.39 5.63 6.63

Ac Value in M2

Mass / kg 8 10 12 12 20 20 12 12 12 12 12 12 15 12

136 km / hour 0.11 0.12 0.30 0.30 0.45 0.59 0.25 0.25 0.17 0.17 0.19 0.19 0.42 0.19

161 km / hour 0.05 0.05 0.19 0.19 0.30 0.39 0.15 0.15 0.09 0.09 0.11 0.11 0.27 0.16

184 km / hour 0.02 0.03 0.13 0.13 0.21 0.28 0.09 0.09 0.04 0.04 0.05 0.05 0.17 0.07

204 km / hour - 0.01 0.08 0.08 0.14 0.20 0.04 0.04 0.01 0.01 0.01 0.01 0.10 0.02

Lighting Point Height 8000 8000 8000 8000 8000 8000 10000 10000 10000 10000 10000 10000 10000 12000

Page 5: Alcopole - Conical Poles with Consoles

38

Standard Lighting Column

Article number (Buried) ABB.029.120 ABB.030.140

Article number (Flanged) AFB.029.120 AFB.030.140

Surface area of column / m² 7.48 7.64

Dimensions

A Base 200 200

B Top 76 76

C Mass 100.6 100.6

D Wall thickness 5 5

E Light point height 12000 12000

F Groundrooth protection 1700 1700

G Access door position 420 420

H Access door dimensions 600x115 600x115

I Cable entry dimensions 150x50 150x50

J Cable entry position 500 500

K Max. dimensions of cutout 110x145x485 110x145x485

L Bracket Lenght 1250 1250

M Radius 380 380

N Angle 15° 15°

Column with baseplate

Baseplate Article Number 607 607

Surface area of column 3.91 3.91

Ac Value in M2

Mass / kg 12 12

136 km / hour 0.19 0.19

161 km / hour 0.16 0.16

184 km / hour 0.07 0.07

204 km / hour 0.02 0.02

Lighting Point Height 12000 14000

CONICAL POLES WITH CONSOLESTechnical Data

Page 6: Alcopole - Conical Poles with Consoles

39

Standard Lighting Column

The standard lighting column has a base-holder, thermoplastic protection and integrated mounting rail, without options or other accessories.

Dimensions

The specifications of the standard lighting column are expressed in the following units:A Base diameter - mmB Top diameter - mmC Mass - kgD Wall thickness - mmE Lighting point height - mmF Groundrooth protection - mmG Access door position - mmH Access door dimensions - mm - (height x width)

I Cable entry dimensions - mm - (height x width)

J Cable entry position - mmK Max. cutout dimensions - mm - (height x depth x width)

Surface area of lighting column …m2

Lighting Column With Baseplate

Standard lighting column with mounted baseplate (excluding base-holder length), without options or accessories.

Ac Value in m2

The Ac value is a combination of the projected surface area and the luminare fixing depth’s coef-ficient of from, expressed in m2 . The maximum Ac values permitted have been stated for the various wind speeds. The values indicated have been de-termined using the European EN-40 standard. The mass of the light fitting on which the calculations have been based is also stated.

Description