ALFO SYSTEM VERSION 01.06.02
UPGRADING PROCEDURE
1. PRELIMINARY
Start installed SCT program
Connect to Alfo
2. SOFTWARE DOWNLOAD
Select Equipment Version window
Click on Download SW Setup
In Download type mark Forced and Bench switch
In Download file path select this dwl file: 010602_lclfe1.dwl Click on Start and confirm by clicking on Proceed to download button. Bench status will
become Downloading
At download end, a result banner will appear
Wait for Alfo restart and Sct reconnection
Check new loaded software version by re-opening Equipment Version window
Software Version 010602 (LC-LF-E1)
FW Boot
FW Appl
FPGA 0FPGA 1
E82089 010012 or 010011
N90538 010402
Not presentN90560 000200
3. CONFIGURATION AND ALARMS UPDATING
After upgrading will appear Unit Sw Mismatch Alarm because Alfo is without PPP
configuration. In order to remove this alarm is needed to install SCT 4.5.2 (or successive)
otherwise is possible to remove alarm using a WEB browser (Internet Explorer, Mozilla)
3.1 CONFIGURATION AND ALARMS UPDATING WITH SCT 4.5.2 (or successive)
Click on Equipment-Communication SetUp Port Configuration
Select 2Mb EOC tab
Set the wished configuration or a default one (No 2Mb used means ALFO without PPP)
Unit Sw Mismatch Alarm should disappear
Click on Equipment-Alarm Severity Config
Set Properties of new alarm Tru SW RadioEquipment2MbEocLinkAlarm (This is the
alarm used to show a PPP protocol connection fail, normally is Warning-Trap on)
-
7/30/2019 ALFO Indonesia
2/2
3.2 CONFIGURATION AND ALARMS UPDATING WITH WEB-BROWSER
Disconnect SCT from unit (if connected)
Connect to unit using WEB browser: insert on Address line Http://
Login page will appear: insert password siaemicr and click Login button
If login is accepted, 3 frames will appear:
A main frame on the center-right of the screen (to view status and set parameters)
An option list frame on the left (to select option and view related main frame)
An alarm summary frame on the high-left (to view current alarms/operations summary)
On the list frame, select CONFIGURATION E1 settings
On the main frame, change E1 Network configuration, or confirm the default one, clicking on
related Apply button
On the list frame, select CONFIGURATION Alarm settings
On the main frame, scroll alarms to find E1 Eoc link alarm
Select this alarm clicking on related check box
Change alarm properties (from Disabled to sev. Warning-trap On) and then click on related
Apply button