Page 1: ALKON 90 - Unical AG

ALKON 90

Page 2: ALKON 90 - Unical AG

ALKON 90

MODELmax/minnominal heatoutput

max/min heat input kW

ALKON 90

22 - 90

condensing kW

conventional kW

efficiency class (Directive 92/42)

24,0 ÷ 93,6

21,1 ÷ 87,5

Moving in the present with thefuture in mindA pioneer in condensing technology andinnovative home heating solutions, Unical hasdeveloped the ALKON 90 boiler, whichguarantees, in time, the best energeticperformances and minimum fuel consumption,even in the most difficult heating applications.

Natural habitat: outdoorinstallation A single cast heat exchanger (an exclusiveUnical design) of aluminium-silicon-magnesiumalloy for a 90 kW heat input, enclosed in acompact cabinet, built in corrosion-resistantsteel paint, ideal for both indoor and outdoorinstallations, thanks to the maximum protectiongrade IP X5D rating.

90 kW maximum and 22 kW minimummodulating input, in order to guarantee anextraordinary adaptation to the various heatdemands.

Electronic controls derived from theprestigious range of Unical Modulex boilers.

The ALKON 90 boiler can be installed in acascade formation, thanks to its specialI.TOTHEM modulating system. A single heatingcascade controller can control 2 modularbanks of 4 boilers each (720 kW).

Comprehensive versatilityA wide range of optional accessories are availablewhich permit you to create a flexible combinationvalid for every type of heating system.

Page 3: ALKON 90 - Unical AG

The reasons for choosingan ALKON 90 boiler

Contained dimensions: Height: 130 x Width: 51 x Depth: 60 cm

Innovational combustion: pre-mix multigas modulatingburner with constant C02 emission

Up to 109% efficiency on N.C.V.

Low NOx emissions – CLASS 5 rating (EN 483)

Elevated modulating ratio: 1:4

Easy to install: compact and simple connections

Standard modulating pump controlled directly by the boiler

BCM (Burner Cascade Manager) interface for remote control (optional)

I.TOTHEM cascade formation for a bank of up to 4 boilers (2x)

IP X5D protection grade for outdoorinstallation

Dedicated series of accessories:- Mixing headers- Additional safety devices- E8 heating controller- Acidic condensate neutralizing kit

Page 4: ALKON 90 - Unical AG

MODULATING FANFLUE OUTLETDUCT Ø 100

IGNITION ELECTRODE CAST ALUMINIUM-SILICON-MAGNESIUM ALLOY HEATEXCHANGER

CONDENSATEDRAIN POINT

PRE-MIX AIR/GASANTECHAMBER

FLAMEDETECTIONSENSOR

Thanks to its particular technicalconfiguration, synonymous of quality and safety,

the ALKON 90’s heat exchanger is suppliedwith a 5 year guarantee.

Analysis ...

Discovering the ALKON 90 boiler

The heat exchangerA real work of art in aluminium-silicon-magnesium alloy, weighing 35 kg, with a surfaceof heat transfer superior to 2 m2 and compactdimensions (50x23x34 cm). It is characterizedby its very fast water circulation circuit, designedfor maximum efficiency, thanks to the hydraulicdistribution which, from a central collector,converges the water flow to the external walls.It contains about 8 litres of water and is completelyinsulated. Thanks to these characteristics, the ALKON 90 boiler reacts rapidly to everytype of user request, favoured by:• The primary ring appositely dimensioned by

Unical• NTC temperature sensors positioned on the

flow and return pipes, which by controllingthe difference in temperature in real time, are able to adapt the output constantly andinstantaneously.

Therefore heat inertial is nonexistent, theappliance fires or stops immediately, therebyavoiding energy waste when unrequested (aninevitable phenomenon with high water contentgenerators, obviously much more slower inresponding).

The burnerThe new modulating multigas burner (Naturalgas/LPG), fitted with a two-valve one block Dungssystem, is avant-garde in the field of combustiontechnology. Combined with the special doublestainless steel metallic fibre burner, it offers youreliability, silent operation and very highcombustion efficiency.

ModulationThe optimal modulation ratio (1:4) permits thefollowing types of performances:• Steady CO2 equal to 9,6% on all the output

range from 22-90 kW.• NOx equal to 35,62 mg/kWh which classifies

the ALKON 90 boiler in the 5th NOx Class.• CO equal to 104,4 mg/kWh• Condensate production from 1,8 kg/h

to 14,5 kg/h

guaranteeyear

Page 5: ALKON 90 - Unical AG

MAXIMUM OUTPUT:

93,6 kW

MINIMUM OUTPUT:

24 kW

∆t 23 K ∆t 13 K

ALKON 90’s USEFUL EFFICIENCY IN FUNCTION OF THE OUTPUT ANDINTERVENTION OF THE MODULATING PUMP

THE MODULATING PUMP ENSURES THAT THE ∆T (REFER TO TABLE) BETWEEN THE FLOW AND RETURNIS MAINTAINED AT A HIGH LEVEL AND SUBSEQUENTLY THE BOILER WILL OPERATE IN CONDENSING MODE

FOR A LONGER PERIOD.

90

106

92

94

96

98

100

102

104

108

110

... point by point

Standard modulating pump• Maximum efficiency• Drastic reduction of fuel and electricity

consumption• Condensate production optimization

The ALKON 90 boiler incorporates anadvanced microprocessor control boardwhich is able to constantly control the dataregarding the temperature difference (∆T between the flow and return rateand the rated output).Thanks to this supervision, if themanometric head is not within thecalculated parameters the pump adapts itsflow rate immediately, thereby ensuringoptimization of the condensate productionand maximum efficiency, as well as adrastic reduction of electricity consumptionabsorbed by the pump:

ALKON with MODULATING PUMP 3360 ÷ 1400 l/h

A close-up view of the 3-way valve

Electrical absorption(W)

Modulation(%)

100 % 170 max

25 % 95 min

Safety measuresThe standard safety measures of the ALKON 90 boiler have been increased with:

• a gas pressure switch: it shuts down the boiler if the gas supply pressure is lowerthan 14 mbar;

• a low water pressure switch: it shuts down the boiler in case of pressure drops;• safety level sensor: it shuts down the boiler if the condensate does not drain away

correctly• safety valve: set at 7 bar• electrical connection for additional safety devices.

Moreover, for practical drainage of the appliance at the condensate drainage pointand for total safety in case of maintenance, the ALKON 90 is supplied with a:• 3-way valve with full opening on the flow pipe• 2-way valve integrated with flow-stop on the return pipe.

Use

ful e

ffic

ienc

y (%

)

Output (kW)

90 80 70 60 50 40 30 2093,6

97,3

108,64108,64107

106

101,5

108,64108,64107

106

101,5

97,3

Page 6: ALKON 90 - Unical AG

The control panel

Fault diagnostic display

DHW set key CH selection key: Stand-by/Central heating

Reset key/Fault code display

Central heating adjustment key

Temperature increase key

Temperature decrease key

BCM control boardThe ALKON 90 boiler is able to reach itsmaximum performance when the optionalaccessory BCM (Burner Cascade Manager)is incorporated in the heating system.

• Heating demand control: it controlsthe modulation level and thetemperature

• Boiler operation management

• Communication with PLC controlledplants

• Burner controller alarm reset.

• Emergency function in case of E8 failure

BCM board(Burner Cascade Manager)

Simple to useThe ALKON 90 is a versatile boiler. Particularcare has been given to the flexibility of thecontrols. The control panel is equipped withan alphanumerical display with 6 pre-selectionkeys, which enable the user to view the following information:Boiler operation• Boiler status; flow and return temperature;• Fault diagnostic display;

User’s parameters• Maximum temperature settings• On/off central heating

Parameters with access code• Type of mode selected: room thermostat (on/off),remote heating control, on-off or modulatingpump;• Pump overrun• Fan ignition speed

Data readout• Global flow and return temperature• DHW temperature (if incorporated with a hotwater cylinder)

Page 7: ALKON 90 - Unical AG

Functions whichcan be activated with the E8

Domestichot waterproductionThere are manyprogrammeswhich controlthe domestichot waterproduction.You canchoose from the maximum of comfort to themaximum fuel saving. In order to permit thestorage cylinder to supply hot water rapidly,the heating controller brings the boiler’stemperature to the maximum set value.

AntilegionEvery 20th heating start-up or once a weekon Saturday at 01:00 hrs, the storage tank isheated up to 60°C. This function will eliminateany eventual pathogens which have formedin the DHW.

Frost protection modeThe frost protection operation mode preventsthe CH system from freezing by automaticallyswitching heating operation on. In the frostprotection mode, the room temperature forall the heating circuits is set to 5°C and thestorage tank sensor frost protection is activatedwhen the temperature drops below 10°C.

DHW optimization (loadingpump)The DHW loading pump is switched ononly if the boiler temperature exceeds by5°C the storage tank temperature. It isdeactivated when the boiler temperaturedrops below the storage tank temperatureor if the storage tank temperature is higherthan the nominal temperature.

Slope offset (heating slopedistance)The boiler temperature that is required for

a mixed circuit is calculatedby adding to the calculatedtemperature setting for theheating circuit temperature the heating slope distance. The heating slope distancecompensates for sensortolerances and heat loss up tothe mixer.

Number of burner ignitionsIt stabilizes the number of ignitions of eachburner

Burner run hoursIt stabilizes the run hours of each burner

Valve opening timeBased on the characteristics of theservomotor

Integration with renewableenergy sourcesAs for example: solar systems and/or solidfuel fired boilers

And more:

• Management of up to 15 mixed circuitscontrolled by the outdoor sensor (refer toaccessories: BM8 digital remote control withinterface for bus-can, outdoor temperature sensorfor BM8)

• 0-10 volt signal: the great flexibility of the E8also permits the ALKON 90 set point to becontrolled by an external control signal. This willenable, having at disposal an even more complexsystem, to exploit all the heating control’s functions.

• Remote controls: available in the near future

via appropriate software, this function enablesthe reduction of system management, remoteindication of boiler run, thereby avoidingunnecessary inspection visits.

Self-adaptionThrough the elaboration of data transmittedby the room sensor, this function adjusts theboiler’s ouput to the building’s characteristics,ensuring a constant monitoring of the indoortemperature on the basis of the variation ofthe outdoor temperature, keeping inconsideration the building’s thermal inertiaand the contribution of “free” heat (solarradiation, internal heat sources etc).

Boiler heating OptimizationThe heating controller, on the basis of thetimer/heating programme set by the user,once the system’s characteristics have beenevaluated, will activate the function forautomatically bringing forward the heatingignition time so as to ensure that the settemperature is reached at the time requestedby the user.

Fast set temperatureThis is obtained by calculating the optimumignition start-up time. This calculation canbe carried out taking into consideration theoutdoor temperature or the room temperature.

Overheating protectionThe boiler’s safety temperature is controlledvia the pump’s overrun time in order to getrid of any thermal inertia.

Multiple zone controlWith the same heating control device youcan control 2 independent circuits withdifferent characteristics, though havingensured all the described functions, includingthe deep sliding temperature function.

Programme settingThe heating programmes can be set dailyor weekly, with more than one On-Off firingtimes or temperature reductions during thearch of the day.

Swimming pool heating function

E8: the intelligent heating controllerThe application and connection of the dedicated E8heating controller (optional), permits a decisive qualitativeleap in boiler management in function of the appliedloads. The E8, as well as becoming the window ofdialogue with the boiler, thanks to its features, permitsthe complete management of the CH system, exploitingthe maximum modulating output and the maximumobtainable condensation.

ALKON’s intelligent brain

Page 8: ALKON 90 - Unical AG

Note: Several additional safetydevices are not supplied

because their setting is subject tothe type of heating system

installed.

Range of system components

The new visionof the modern heating system

is no longer satisfiedwith just the boiler!

Therefore, Unical placesat your disposal a rich

catalogue of componentswhich facilitate the system’s

layout and enable youto obtain the maximum result

from the technologyemployed and the heating

system design.

BOILER ALKON 90 “MASTER” boiler natural gas cod. 41010081

LPG cod. 41010082

Complete with:Side panels, blind flanges with bolts and nuts, single boiler top, gas feed pipings, flow and return system pipings, modulating pump.Note: It is possible to order the outdoor cover kit (code 00361529) for containing and protecting the additional safety devices kit. In this case the Cover for 2 is needed (code 00361522 – incorporated with an unused flue outlet closure tap).

COMPONENTS FOR EXPANDING THE ELECTRONIC CONTROLS E8 heating controller kit cod. 00361332

Composed of:Electronic heating control, outdoor sensor, mixed flow sensor, boiler sensor, DHW storage tank sensor, terminal strip

E8 WAG holder for wall mounting installation cod. 00361359 Expanding module E8.1124 cod. 00361545 Additional zone control BM8 cod. 00361358

(digital timer with outdoor sensor for connection to CAN-BUS 4 wires) BCM board cod. 00361602

MIXING HEADER and additional safety devices Mixing header up to 180 kW cod. 00361499 Mixing header connection kit DN 65 cod. 00361484 Y filter DN 65 cod. 00361488 Additional safety devices pipe kit + hydraulic and gas collectors cod. 00361528 Additional safety devices kit cod. 00361316

Composed of:3-way cock 1/2”, pressure gauge R 3/8”, n°2 bulb holders, 100°C H.L. thermostat, 5 bar safety max pressure switch, thermometer, shock absorber for pressure gauge.

Outdoor cover kit complete with additional safety device holders cod. 00361529 Additional safety devices holder kit cod. 00361463

ACIDIC CONDENSATE NEUTRALIZER Condensate neutralizing kit NH 500 cod. 00361551

FLUE OUTLET ACCESSORIES (in aluminium) Vertical flue terminal Ø 100 cod. 00361493 Horizontal flue terminal Ø 100 cod. 00361494 Extension Ø 100 L=1000 cod. 00361495 90° elbow Ø 100 cod. 00262514 45°elbow Ø 100 cod. 00262476

Page 9: ALKON 90 - Unical AG

KIT NH 500FLOW RATE

BOILER OUTPUT

FLUID TEMPERATURE

STAGNATION POINT HEIGHT

NEUTRALIZING SUBSTANCE

DURATION OF NORMAL CONDENSATE

CONDENSATE/AMBIENT WATER TEMPERATURE

DIMENSIONS (lengthxwidthxheight)

INLET/OUTLET CONNECTION

INLET/OUTLET HEIGHT

l/h

kW

°C

mm

°C

mm

mm

UP TO 70

UP TO 500

5-40

90

GENO® - Neutralit -Hz12 months(1500 working hours)

5 - 60

476x300x185

DIN 15

50/90

DHW STORAGE – PRODUCTION CYLINDERS

To complete the heating system, in the catalogue, there are different models of DHW storage and production cylinders available,with a coil heat exchanger and with solar integration (from 100 to 2000 litre capacity, and supplied with a magnesium anode)

Solar integration

SANICAL SC 150 cod. 32703 SANICAL SC 200 cod. 32704 SANICAL SC 300 cod. 32705 SANICAL SC 400 cod. 32706 SANICAL SC 500 cod. 32707 SANICAL SC 600 cod. 32708 SANICAL SC 800 cod. 32709 SANICAL SC 1000 cod. 32710

Integration with only boiler

From the left: SANICAL, SANRIS, BIKOMPACT, and BISER

BISER 300 BISER 500 BISER 800 BISER 1000 BISER 1500 BISER 2000 BIKOMPACT 300 SANRIS 500 SANRIS 800 SANRIS 1000 SANRIS 1500 SANRIS 2000

The NH 1000 kit is available for higher outputs

Other accessories

Neutralizing kit

cod. 00262490cod. 00262493cod. 00262485cod. 00262494cod. 00262486cod. 00262487cod. 00262310cod. 00262495cod. 00262496cod. 00262497cod. 00262488cod. 00262489

The condensate water, produced during combustion,reacts with NOx forming acidic molecules (pH value=4,5). It could become necessary to neutralize thesesubstances before their emission in the drainagesystem water. In order to respect the ecosystem Unicalproposes the NH condensate neutralizer.

Optional acidic condensateneutralizing kit

KIT NH 500 – for boiler outputs up to 500 kW (cod. 00361551). Neutralization occurs according to theprinciple of the passage of acidic condensate throughthe granular neutralizing material. The passage takesplace from the bottom to the upper direction.

Page 10: ALKON 90 - Unical AG

The key quality features

I.TOTHEM: heat module complete with primary ring, composedof additional safety devices kit and mixing header

Pre-mixed combustion system with constant CO2 emission (modulating gas valve, modulating fan and stainless steel burner)

Aluminium (AlSiMg) heatexchanger/condenser (a detail of the combustion chamber)

Modulating pump for maximumcondensate production

The control panel can be opened tofacilitate maintenance

E8 heating controller (optional) for complex heating plantsand cascade applications with WAG holder

Microprocessor boiler control board

Simple installation(detailed view flange/flange)

BCM board for remote control(optional accessory)

Page 11: ALKON 90 - Unical AG

Dimensions and technical data

MODEL ALKON 90

1300

FRONT VIEW

Legend:

R - Heating system return DN 80

M - Heating system flow DN 80

G - Gas inlet DN 50

Sc - Condensate siphon drain outlet Ø 32 mm

24 ÷ 93,6

21,1÷ 87,5

22 - 90

97,26

105,2

104,0

108,64

98,15 / 98,31

0,90

9,6

21,5 - 104,4

35,62

14,54

5

II2H3P

30 / 85

0,5 - 8 *

15,14

303

230/50

X5D

135

kW

kW

kW

%

%

%

%

%

%

%

mg/kWh

mg/kWh

kg/h

°C

bar

l/min

W

V/Hz

IP

kg

Output

MIN/MAX NOMINAL HEAT OUTPUT IN CONDENSING MODE

MIN/MAX NOMINAL HEAT OUTPUT IN STANDARD MODE

MIN/MAX HEAT INPUT

Efficiency

EFFICIENCY CLASS (DIRECTIVE CEE 92/42)

REQUIRED EFFICIENCY AT NOMINAL LOAD (100%)

REQUIRED EFFICIENCY AT 30% PART LOAD

ACTUAL EFFICIENCY AT NOMINAL LOAD (100%) IN CONDENSING MODE

ACTUAL EFFICIENCY AT 30% PART LOAD IN CONDENSING MODE

COMBUSTION EFFICIENCY AT NOMINAL LOAD (100%)/ PART LOAD

STAND-BY LOSSES (MIN-MAX)

Combustion

CO2

CO AT 0% OF O2 (MIN)

NOx (VALUE ACCORDING TO EN 483)

MAX CONDENSATE PRODUCTION

NOx Class

APPLIANCE’S GAS CATEGORY

Central Heating

MIN/MAX OPERATING TEMP. IN CH MODE

MIN/MAX PRESSURE IN CH CIRCUIT

MIN. WATER FLOW RATE IN CH CIRCUIT ∆T 20°C

Electrical Supply

MAXIMUM ABSORBED POWER

ELECTRICAL SUPPLY / VOLTAGE / FREQUENCY

ELECTRICAL PROTECTION

Weight

NET WEIGHT

(* ) Boilers approved at 8 bar. Safety valves are available on request.Note: Values measured at room temperature = 20°C

REAR VIEW

513

607

Page 12: ALKON 90 - Unical AG

I.TOTHEM

Integration and perfectcompatibilityALKON 90 multiplies itself!The flexible E8 heating controller, via the e-Bus connection system,permits the management, with onlytwo wires, of up to 8 heating modules.The I.TOTHEM range of boilers with two banks of 4 boilers each, can supply a total output of up to720 kW, for maximum flexibility of use. All approved and certifiedaccording to the relevant Standardsand requirements.

Rapid installation andmaximum compactThe ALKON 90 boiler has been designedwith a modular structure. The externalcover is made in steel (with noncorrosive paint and a IP X5D protectivelevel) and contains a heat exchanger,pump, and pre-fitted pipings. Installationis simplified by the rapid flange/flangeassembly on both the water and gassides. The same cover can also containand protect the additional safety devicesand an eventual primary expansionvessel.

Easy to service• Doors with reversible openings• Control panel which can be opened

for facilitating access and removingcomponents for inspection

• Rapid division of the circuits andisolation of each heating modulevia the ball valves supplied asstandard.

Very high efficiencyThis gives us the advantage of havingat disposal, where space is at a

Page 13: ALKON 90 - Unical AG

I.TOTHEM: a bank of n°4 ALKON 90 units with a coverfor outdoor installation, completed with additional safety devices.

Custom made for the heatingsystemThe versatility of combinations which the ALKONI.TOTHEM modular system offers is practicallyendless. In this case you can choose an ALKON 90 as the lead boiler who, via the E8heating controller “controls” the successive ALKON 90 boilers, who are also equipped with a pump. Choosing from the accessoriesavailable, the multiple formation of boilers willbe constructed on the basis of the system’srequirements. Each boiler can be fitted with asingle flue outlet or the flue gases can be conveyedinto a sole collector.

premium, high efficiency heatingmodules, guaranteeing:

Recovery and restoration of oldheating plants.

Better efficiency levels thanks tothe excellent modulation ratiowhich reduces the output in allthe boilers proportionally to theload required and shuts themdown in sequence.

Reliable operation under everycondition thanks to loadmatching.

Page 14: ALKON 90 - Unical AG

Maximum efficiency in every situationThe ALKON 90 boiler has an approvedefficiency which, when the load reduces,increases progressively from 104 to 109%(in condensing mode).

This is possible because the heat exchangerincreases its efficiency and the fluetemperature decreases when the input isreduced.

One of the prominent features of the E8heating controller is to maintain the majornumber of ALKON 90 units, in theI.TOTHEM multiple boiler formation, firingat the lowest possible rate in order toincrease the total operating efficiency.

Reduced heating loadAs illustrated in the sequence on this page,this proportional partition of the outputreduces each heating module to 22 kW.If the required load is inferior to the totalminimum output of the single units (n° units x 22 kW), only the ALKON 90boilers needed to reach the requestedoutput at the maximum efficiency levelwill be fired, and the other units will beshut down.

Moreover, in order to ensure an equaldaily rotation of each module, every 24hours each unit will be fired alternately,so as to ensure that each one operates forthe same number of hours.

I.TOTHEMmaximum output and efficiency

360 kWRequested output

η = 104Total efficiency

90 kW 90 kW 90 kW 90 kW

180 kWRequested output

η = 107,2Total efficiency

45 kW 45 kW 45 kW 45 kW

20 30 40 50 60 70 80 90

104

106

108

Output (kW)

ALKON 90 EFFICIENCY

Eff

icie

ncy

(%)

66 kWRequested output

η = 109Total efficiency

22 kW 22 kW 22 kW OFF

22 kWRequested output

η = 109Total efficiency

22 kW OFF OFF OFF

109

Page 15: ALKON 90 - Unical AG

the configurationsI.TOTHEM

I.TOTHEM: a bank of n°4 ALKON 90 unitswith a casing for outdoor installation,

completed with an additional safety devices kit.

5

4

6

19

7

8

Ed

. n°

1 -

02/2

007

- c

od. 3

3795

3

9

1

2

7

8

3

2

2

2

1

Note: Several additional safety devices are not supplied because their setting is subject to the typeof heating system installed. If installing a heating system with outputs superior to 360 kW pleasecontact our After Sales Service Department .

* If the casing kit for outdoor installation complete with additional safety devices support kit (pos. 9) is installed, order the top (equipped with an unused flue outlet closure tap) consideringan additional element (for example, for n°3 ALKON 90 units with the casing kit for outdoor installation complete with additional safety devices support kit, order the Top for 4)

COMPONENTS FOR EXPANSION ELECTRONIC MANAGEMENT E8 heating controller kit cod. 00361332 WAG holder kit for wall mounting installation cod. 00361359 Zone heating E8.1124 expansion kit cod. 00361545 BM8 remote control kit cod. 00361358 BCM board cod. 00361602

ACIDIC CONDENSATE NEUTRALIZERS Condensate neutralizing kit NH 500 cod. 00361551

ADDITIONAL FLUE OUTLET ACCESSORIES Vertical flue terminal Ø 100 cod. 00361493 Horizontal flue terminal Ø 100 cod. 00361494 Extension Ø 100 L=1000 cod. 00361495 90° elbow Ø 100 cod. 00262514 45° elbow Ø 100 cod. 00262476

ADDITIONAL FLUE OUTLET ACCESSORIES FOR MULTIPLEBOILER FORMATION (in pps) Flue thermostat cod. 00361451

for n°2 boilers Basic cascade kit n°2 ALKON 90 boilers Ø 160 cod. 00361339

for n°3 boilers Basic cascade kit n°2 ALKON 90 boilers Ø 160 cod. 00361339 Extension kit n°3 ALKON 90 boilers Ø 200 cod. 00361340

for n°4 boilers Basic cascade kit n°2 ALKON 90 boilers Ø 160 cod. 00361339 Extension kit n°3 ALKON 90 boilers Ø 200 cod. 00361340 Extension kit n°4 ALKON 90 boilers Ø 200 cod. 00361341

BASIC BOILER CONFIGURATION ALKON 90 “MASTER” natural gas cod. 41010081

LPG cod. 41010082

ALKON 90 combined with “MASTER” natural gas cod. 41010046LPG cod. 41010048

it does not include: Side panels, blind flanges with bolts and screw nuts, single boiler top.

Top for 2 * cod. 00361522 Top for 3 * cod. 00361523 Top for 4 * cod. 00361524 Top for 5 * cod. 00361525

MIXING HEADERfor n°2 boilers Mixing header up to 180 kW cod. 00361499 Mixing header connection kit DN 65 cod. 00361484 Y filter DN 65 cod. 00361488

for n°3÷4 boilers Mixing header up to 360 kW cod. 00361500 Mixing header connection kit DN 100 cod. 00361487 Y filter DN 100 cod. 00361489

Additional safety devices Stub pipe kit + water and gas collectors cod. 00361528 Protection and control kit for water collector cod. 00361316 Casing kit for outdoor installation complete