alternative mwd magnetic qc-test...proposal for an alternative mwd magnetic qc-test inge edvardsen...
TRANSCRIPT
![Page 1: Alternative MWD Magnetic QC-test...Proposal for an Alternative MWD Magnetic QC-test Inge Edvardsen Baker Hughes](https://reader030.vdocument.in/reader030/viewer/2022040508/5e4ac4ae007d7b25336467c9/html5/thumbnails/1.jpg)
Proposal for an Alternative MWD Magnetic QC-test
Inge EdvardsenBaker Hughes
![Page 2: Alternative MWD Magnetic QC-test...Proposal for an Alternative MWD Magnetic QC-test Inge Edvardsen Baker Hughes](https://reader030.vdocument.in/reader030/viewer/2022040508/5e4ac4ae007d7b25336467c9/html5/thumbnails/2.jpg)
AGENDA
•Definition of Magnetic Total Field and Dip Angle tests
•The 90/90 QC case
•Examples
•Considerations
2
![Page 3: Alternative MWD Magnetic QC-test...Proposal for an Alternative MWD Magnetic QC-test Inge Edvardsen Baker Hughes](https://reader030.vdocument.in/reader030/viewer/2022040508/5e4ac4ae007d7b25336467c9/html5/thumbnails/3.jpg)
Total Magnetic Field/Dip Test
•Earth’s magnetic field strength and dip angle calculated from tool’s magnetometer and accelerometer outputs
•Compared with the Reference Field values
•Error model estimations for the directional sensors and the reference field define how well the two should agree
3
![Page 4: Alternative MWD Magnetic QC-test...Proposal for an Alternative MWD Magnetic QC-test Inge Edvardsen Baker Hughes](https://reader030.vdocument.in/reader030/viewer/2022040508/5e4ac4ae007d7b25336467c9/html5/thumbnails/4.jpg)
Drilling at 90/90
•Azimuth is sensitive to axial interference, Bt and Dip are not
•Standard QC tests are insensitive to excessive axial interference
– SPE 133417 (ISCWSA)
•Stimulus for finding new QC test
4
Y
Z
X
![Page 5: Alternative MWD Magnetic QC-test...Proposal for an Alternative MWD Magnetic QC-test Inge Edvardsen Baker Hughes](https://reader030.vdocument.in/reader030/viewer/2022040508/5e4ac4ae007d7b25336467c9/html5/thumbnails/5.jpg)
Alternative QC Tests
•Bh-
Horizontal component of the Earth’s magnetic field
•Bv-
Vertical component of the Earth’s magnetic field
•Bz-
Magnetic field along the axial direction
5
![Page 6: Alternative MWD Magnetic QC-test...Proposal for an Alternative MWD Magnetic QC-test Inge Edvardsen Baker Hughes](https://reader030.vdocument.in/reader030/viewer/2022040508/5e4ac4ae007d7b25336467c9/html5/thumbnails/6.jpg)
Examples
•QC test limit values
– BH and Statoil method (presented at ISCWSA 12 and 13)
– BH error models used
•
Axial Interference: 150nT (1σ) everywhere
•Error assumptions
– All error sources assumed to be zero
– One out of spec condition introduced at a time
6
![Page 7: Alternative MWD Magnetic QC-test...Proposal for an Alternative MWD Magnetic QC-test Inge Edvardsen Baker Hughes](https://reader030.vdocument.in/reader030/viewer/2022040508/5e4ac4ae007d7b25336467c9/html5/thumbnails/7.jpg)
Example 1:
•
Btotal
50000 nT•
DIP
70 Deg•
Bz-bias
600 nT
7
![Page 8: Alternative MWD Magnetic QC-test...Proposal for an Alternative MWD Magnetic QC-test Inge Edvardsen Baker Hughes](https://reader030.vdocument.in/reader030/viewer/2022040508/5e4ac4ae007d7b25336467c9/html5/thumbnails/8.jpg)
8
![Page 9: Alternative MWD Magnetic QC-test...Proposal for an Alternative MWD Magnetic QC-test Inge Edvardsen Baker Hughes](https://reader030.vdocument.in/reader030/viewer/2022040508/5e4ac4ae007d7b25336467c9/html5/thumbnails/9.jpg)
9
Example 2:
Btotal
50000 nTDIP
0.00DegBz-bias
600nT
![Page 10: Alternative MWD Magnetic QC-test...Proposal for an Alternative MWD Magnetic QC-test Inge Edvardsen Baker Hughes](https://reader030.vdocument.in/reader030/viewer/2022040508/5e4ac4ae007d7b25336467c9/html5/thumbnails/10.jpg)
10
![Page 11: Alternative MWD Magnetic QC-test...Proposal for an Alternative MWD Magnetic QC-test Inge Edvardsen Baker Hughes](https://reader030.vdocument.in/reader030/viewer/2022040508/5e4ac4ae007d7b25336467c9/html5/thumbnails/11.jpg)
11
Example 3:
Btotal
50000 nTDIP
45 DegBxy-bias
600nT
![Page 12: Alternative MWD Magnetic QC-test...Proposal for an Alternative MWD Magnetic QC-test Inge Edvardsen Baker Hughes](https://reader030.vdocument.in/reader030/viewer/2022040508/5e4ac4ae007d7b25336467c9/html5/thumbnails/12.jpg)
12
![Page 13: Alternative MWD Magnetic QC-test...Proposal for an Alternative MWD Magnetic QC-test Inge Edvardsen Baker Hughes](https://reader030.vdocument.in/reader030/viewer/2022040508/5e4ac4ae007d7b25336467c9/html5/thumbnails/13.jpg)
Considerations
•Add the Bz test to the standard set of QC tests for non- axial interference corrected surveys.
•Evaluate the Bh
& Bv
QC tests
• ISCWSA peer review welcomed
13
![Page 14: Alternative MWD Magnetic QC-test...Proposal for an Alternative MWD Magnetic QC-test Inge Edvardsen Baker Hughes](https://reader030.vdocument.in/reader030/viewer/2022040508/5e4ac4ae007d7b25336467c9/html5/thumbnails/14.jpg)
Proposal for an Alternative MWD Magnetic QC-test
Inge EdvardsenBaker Hughes