amadeo door manager 32 - access2 · 2017. 3. 20. · amadeo door manager are part of an expansive...

7
AMADEO DOOR MANAGER 32 Your innovative key card system for hotels and Access control systems TECHNICAL DATA SHEET

Upload: others

Post on 05-Feb-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • AMADEO DOOR MANAGER –32 Your innovative key card system for hotels and Access control systems

    TECHNICAL DATA SHEET

  • www.AMADEO systems.com

    2

    INNOVATION AND FUNCTION:

    Amadeo Door Manager are part of an expansive product portfolio in order to provide a full access control sys-

    tem solution.

    It is a combination of latest RFID and RF technologies together with the most reliable wire online bus protocols

    All communication are encrypted to guarantee the secure data transmissions.

    AMADEO DOOR MANAGER A PERFECT FIT FOR ANY HOTEL OR ACCESS CONTROL

    Amadeo solution for elevators management. Full control on the users tracking allowing them access only to predefined

    areas.

    Flexible integration with external peripheral products such a electrics strikes, energy savers or elevators if required

    Real Online time system, based on the efficiency and optimization of the communications

    The device is installed indoors to ensure secure systems

  • www.AMADEO systems.com

    3

    Wireless and Wired Online

    AMADEO Systems - Online System

    The AMADEO Systems online solution is ideal for properties seeking the ultimate in security and maximiz-

    ing operational efficiency. The wireless online system offers a two-way communication between the front

    desk and the AMADEO Systems electronic , and one wire solution based on the RS485 and Modbus proto-

    col. It enables staff to receive notifications or alerts from the Door manager to a server, an email address.

    The system can also communicate events that occur at the reader to third party devices or systems for greater

    flexibility and control options.

    • Radio Frequency (RF) communications at 868 MHz, which is globally license-free

    • Wired system based on RS485 and ModBus data protocols

    • Secure networking (128 AES encryption)

    • Self-forming networks

    - Large-scale properties

    - Asymmetric link handling network stability even when nodes are within close proximity

    - Real time Online operation.

    - Online reports like alerts and maintenance information's (status, tamper switch etc. are stored in the SQL

    database and can be send via email to the security guard

    - Online recipients as it occurs (by email, SMS, and web services)

    mobile MASTERKEYS solution together with the Wall Readers

    Clever room management with integration with AMADEO Systems

    Entering a room becomes a custom experience, tailored to the unique preferences of each person. For exam-

    ple, the lights adjust to the appropriate level, the television turns on with the appropriate channel and volume

    level, the powered blinds open or close, and the temperature adjusts – all to the professional building auto-

    mation system can be optional linked with the wireless Online link to AMADEO System. The exchange of

    the current door status our Database can be linked to any other Building automation system.

    How does it work?

    A send lock commands direct from Pc to the Door Manager

    Audit trail: System logs wireless all openings nearly in real-time and store it into the system.

    Remote access grant: Send a message to the Door manager– to activate the outputs

    Receive D alerts and notifications via email and visual information on the pc

    Door Alert: Door Manager notifies staff when door has been left in an unsecure position.

  • www.AMADEO systems.com

    4

    TECHNICAL DETAILS:

    PARAMETER TEST CONDITIONS VALUE UNIT

    RFID frequency 13,56 MHz

    RFID communication range Up to 2 cm

    Audit trail 1.000 audits

    RF Frequency/Modulation 868 -870 MHz divided into the sub-

    ranges/GFSK

    In clear line of site Up to 25 meters

    with obstacles it depends

    RF Data rate 1,2 – 500 KBaud

    Wired online system RS485 full duplex

    Power source 12 to 30 V

    Current consumption 1,5 A as average

    Wake up from standby 5 us

    Real time Clock Integrated

    Operating temperature -25 to +75 ?C

    Storage temperature -25 to +75 ?C

    Operation Humidity 0-80 %

    Number of inputs 4 dry inputs

    32 x 2A/30VDC Relays on board C/NO

    5V motor 0,5A/100mW

    IP20

    IP65(under request)

    IP class

    V(ESD) Electrostatic discharge Human-body model (HBM) ,

    per ASI/ESDA/JEDEC-JS-001± 1000 V

    Number of outputs

    RF Communication range

  • www.AMADEO systems.com

    5

    INPUT / OUTPUTS DESCRIPTION

    Amadeo management of the Input/outputs provides a full configurable rage of solutions for an optimal fit on customer need.

    All configurations can easierly be setted on the software, making possible to work with them independently or realated.

    Following tables shows all possible configurations:

    INPUT ACTION AUDITTYPE OF

    CONTACT

    RELATED

    ACTION

    RELATED

    INPUT

    RELATED

    OUTPUTEXAMPLE OF USE

    0 None No Default value. For not used Inputs.

    1 Audit Yes pulse Emergency door. To audit that it has been opened

    2 Simulate valid card No pulse 17, 19 Push Button at Reception. Will open the Main entrance

    3 Simulate valid card Yes pulse 17, 19 Push Button at Reception. Will open the Main entrance

    4Change: Normal Close --> office or

    Office --> normal closeYes pulse 18, 19 Meeting Room. Set Office at meeting starting and remove office at end

    5Change: Normal Close --> office or

    Office --> normal closeYes Level 18, 19

    Interruptor at Reception. Activated will set main entrace in Office.

    Deactivating it will remove office

    6 Change: Normal Close --> Privacy Yes pulseA card override

    privacy21

    Meeting Room. Set Privacy(Do not disturb) once meeting has started. For

    privacy removing it is needed a card which overrides privacy or another

    input with value 21

    7Change: Normal Close --> Privacy or

    Privacy --> normal closeYes level

    Meeting Room. Set Privacy(Do not disturb) once meeting has start

    activating interruptor. For privacy removing it is needed interruptor

    deactivation

    8 Change: Normal Close --> MUR Yes pulse A master card Guest hotel room. MUR remove will be only possible with a Master card

    9Change: Normal Close --> MUR or

    MUR --> normal closeYes Level

    Guest hotel room. MUR remove will be only possible with interruptor

    deactivation

    12Change: Normal Close --> block or

    block --> normal closeYes pulse

    Blocking

    card/override

    blocking card

    Room needs maintenance at need to be blocked. Only can be removed

    with a override blocking card

    13Change: Normal Close --> block or

    block --> normal closeYes Level

    Blocking

    card/override

    blocking card

    Room needs maintenance at need to be blocked. Only can be removed

    deactivating the interruptor

    15Change: Normal Close --> tamper or

    tamper --> normal closeNo Level 23, 24

    Alarm. Use with a door contact and connect it to an alarm (this alarm

    would be an ouput numbers 23 or 24) and it will be activated while the

    door is opened.

    16Change: Normal Close --> tamper or

    tamper --> normal closeYes Level 23, 24

    Alarm. Use with a door contact and connect it to an alarm (this alarm

    would be an ouput numbers 23 or 24) and it will be activated while the

    door is opened. Will be audited

    17 Change: Normal Close --> Tamper No pulse 19 23, 24If a switch is set in the server closet, it can be connected to an alarm (this

    alarm would be an ouput numbers 23 or 24) and it will not stop until

    another push button (input 19) is pressed

    18 Change: Normal Close --> Tamper Yes pulse 19 23, 24If a switch is set in the server closet, it can be connected to an alarm (this

    alarm would be an ouput numbers 23 or 24) and it will not stop until

    another push button (input 19) is pressed. Will be audited

    19 Change: Tamper --> Normal close Yes pulse 17, 18 23, 24 Used to removed the tamper status created by inputs 17 and 18,

    20Audit during OPEN/CLOSE, only for

    the OC ( this is for virtual WR, OC

    only with doormanagers to audit the

    door contact)

    Yes Not for use

    21 Change: Privacy --> Normal Close Yes pulse 6 Used to removed the Privacy status created by input 6

    INPUTS:

  • www.AMADEO systems.com

    6

    INPUT / OUTPUTS DESCRIPTION

    OUTPUTS:

    OUTPUT ACTION TIMERELATED

    ACTION

    RELATED

    INPUTEXAMPLE OF USE

    0 None Default value. For not used Outputs.

    1 to 16Activate if card has

    authorization 1 to 16t open Present card Lifts. Guest will be allowed only to go to his room floor. Needs external devices and specific wiring

    17Open if a valid card is

    presentedt open Present card 2, 3

    Use for different types of electrik strike. Relay output ALWAYS will be Topen. Even if WR is in office mode, relay

    will not be ON

    18Open if the lock is in

    office mode

    Time while lock is

    in office

    Present card

    with office

    twice

    4, 5This output can be used for a room when it is needed to know that the room is in office mode, a green light on

    the top to know that it is possible to enter

    19

    Open when a valid

    card is presented and

    maintain opened

    while the lock is in

    office

    t open and/or

    time while lock is

    in office

    Present card

    and/or card

    with office

    2, 3, 4 , 5 Standard and most used Output. Will handle the relay following Topen.

    20

    Open if a (*)card

    belongs installation

    but has not access

    granted to that lock

    t openPresent not

    valid cardFor example to put a red light showing to the user that he is not allowed to enter

    21

    Open if (*)card has

    access granted but is

    expired or not valid

    timezon

    t openPresent not

    valid cardFor example to put a red light showing to the user that he is not allowed to enter at this moment

    23 Open while tamperTime while lock is

    in tamper mode15, 16, 17, 18

    As explained with the inputs, it can be used to connect an alarm. It will be switched off when the tamper is

    removed

    24Open when tamper is

    sett open 15, 16, 17, 18 As explained with the inputs, it can be used to connect an alarm.

  • www.AMADEO systems.com

    7

    Head Quarter:

    AMADEO Systems AG

    Skrabalgasse 8, A-1220 Vienna, Austria

    Telephone +43 1 269 63 28—0

    Fax: +43 1 269 63 29

    E-Mail: [email protected]