bridgelux olm series olm™ series modules enable a simple and easy way to develop outdoor...
Post on 25-Apr-2018
218 Views
Preview:
TRANSCRIPT
1
Bridgelux® OLM™ SeriesProduct Data Sheet DS60
OLMB-40X000 | 50X000 | 57X000 |
2
Benefits
• Designed to replace HPS bulbs in outdoor luminaires
• Optimizedforcolorandefficacy
• Long lifetime with a strong return on investment
• Uniform lighting patterns designed for targeted applications
• Improvedthermalmanagement
• Simplifiedrobustluminairedesignandassembly
• Improvedinventorymanagementandqualitycontrol
Introduction
BridgeluxOLM™Seriesmodulesenableasimpleandeasywaytodevelopoutdoorluminaires.Themodulesdeliverhighquality,
energyefficientlightingforcommercial,industrial,andexteriorapplications.Designedforrapidproductdevelopmentand
integration,OLMmodulesmechanicallyattachwithfourscrews.Soldering,glues,andepoxiesareremovedfromtheassembly
processandreplacedwitharobustelectricalconnection.Theintegrationofopticsandenvironmentalprotectionfurthersimplify
luminairedesign.
OLMmodulescontainIP66ratedprotectionandproprietaryopticstoenablethelonglifeandstableperformancerequired
fromluminairesusedinoutdoorlighting.OLMSeriesmodulesleveragetheseventhgenerationVero®Seriesproductfamily,the
latestgenerationofBridgeluxLEDarrays,todeliverlumenoutputlevelstoreplacehighpressuresodium(HPS)andmetalhalide
technologiesusedinoutdoorluminaires.
Features
• Typicalefficacyofupto156lm/Wat70°C
• Typicallumenoutputrangesfrom1600to4600lumens
• BroadrangeofCCToptionsfrom4000Kto5700K
• Minimum70,80CRIoptionsavailable
• Asymmetricandsymmetriclightingpatterns
• IP66ratedforreliableoutdooruse
• High level of component integration
OL
M S
erie
s
3
Contents
Product Feature Map 4
Product Nomenclature 4
Product Selection Guide 5
ElectricalCharacteristics 6
AbsoluteMaximumRatings 7
PerformanceCurves 8
OpticalCharacteristics 9
Mechanical Dimensions 10
DesignResources 11
Precautions 11
Disclaimers 11
About Bridgelux 12
4
Product Feature Map
OLMincorporatesseveralfeaturestosimplifythedesignintegrationandmanufacturingprocess,acceleratetimetomarketandreducesystemcosts.PleaseconsulttheBridgeluxOLMSerieswebpageatwww.bridgelux.comformoreinformation.
Product Nomenclature
ThepartnumberdesignationforBridgeluxOLMSeriesisexplainedasfollows:
1234-5678910-11121314-1516171819
Product Family Internal Code
Minimum CRIC=70CRIE=80CRI
Nominal CCT40=4,000K50=5,000K57=5,700K
OLMB – 40 E 000 – A – 02A AA000
Internal Code
Optical OrientationA=AsymmetricS=Symmetric
Optical PatternSeecharacterizationsinTable5
2D Bar code provides full
manufacturing traceability
Tc Measurement point
located directly under the array
Aluminum mounting plate
adds stability and thermal
spreading
Mechanical mounting holes
Electrical connection wire harness
IP66 rated protection from water and dust
Proprietary asymmetric and symmetric optics
Pressure vent allows moisture and gas removal during thermal cycling
5
Product Selection Guide
Thefollowingproductconfigurationsareavailable:
Table 1: Selection Guide
NotesforTable1:
1. Bridgeluxmaintainsatoleranceof±0.20VonforwardvoltageforOLMmodules.
2. TestedinpulsedconditionsatTc =25°C.Pulsewidthis10ms.3. Bridgeluxmaintainsa±10%toleranceonfluxvaluesforOLMmodules.
4. TypicalperformancewhendrivenunderDC(directcurrent)withOLMmodulecasetemperature(Tc) maintainedat70°C.OLMmoduleismountedtoaheatsinkwiththermalinterfacematerial..Valuesmayvarydependingonthethermaldesignoftheluminaireand/ortheexposedenvironmenttowhichtheproductissubjected.
5. TypicalstabilizedDCperformancevaluesareprovidedasreferenceonlyandarenotaguaranteeofperformance.
Part NumberNominal CCT (K)
CRIDrive
Current (mA)
Typical Vf1
Tc = 25ºC (V)
Typical Power
Tc = 25ºC (W)
Typical Pulsed Flux2,3
Tc = 25ºC(lm)
Typical Efficacy Tc = 25°C(lm/W)
Typical DC Flux4,5
Tc = 70ºC(lm)
Typical Efficacy Tc = 70°C(lm/W)
OLMB-40C000-xxxx-xx000 4000 70
500 21.9 11.0 1802 164 1676 154
750 22.7 17.0 2649 156 2463 146
900 23.1 20.8 3139 151 2918 142
1500 24.4 36.6 4968 136 4619 127
1800 24.8 44.7 5803 130 5395 122
OLMB-40E000-xxxx-xx000 4000 80
500 21.9 11.0 1659 151 1542 142
750 22.7 17.0 2438 143 2266 135
900 23.1 20.8 2889 139 2686 131
1500 24.4 36.6 4572 125 4251 117
1800 24.8 44.7 5341 119 4966 112
OLMB-50C000-xxxx-xx000 5000 70
500 21.9 11.0 1818 166 1691 156
750 22.7 17.0 2672 157 2484 148
900 23.1 20.8 3167 152 2944 143
1500 24.4 36.6 5012 137 4660 129
1800 24.8 44.7 5855 131 5443 123
OLMB-57C000-xxxx-xx000 5700 70
500 21.9 11.0 1755 160 1631 150
750 22.7 17.0 2578 152 2397 142
900 23.1 20.8 3056 147 2841 138
1500 24.4 36.6 4836 132 4496 124
1800 24.8 44.7 5649 126 5252 119
6
Electrical Characteristics
Table 2: ElectricalCharacteristicsandDriverSelectionVoltages
Part NumberDrive Current
(mA)
Forward VoltagePulsed, Tc = 25º C (V) 1, 2, 3 Typical Coeffi-
cient of Forward Voltage4 ∆Vf/∆T
(mV/º C)
Typical Thermal Resistance
Array case to Module case
(º C/W)
Driver Selection Voltages5
(V)
Minimum Typical Maximum Vf Min. Hot
Tc = 105º C (V)
Vf Max. Cold Tc = -40º C (V)
OLMB-xxx000-xxxx-xx000
900 21.4 23.1 24.9 -5.4 0.42 21.0 25.2
1800 23.0 24.9 26.7 -5.4 0.48 22.6 27.1
NotesforTable2:
1. Partsaretestedinpulsedconditions,Tc=25°C.Pulsewidthis10ms.
2. Voltageminimumandmaximumareprovidedforreferenceonlyandarenotaguaranteeofperformance.
3. Bridgeluxmaintainsatoleranceof±0.20VonforwardvoltageforOLMmodules.
4. Typicalcoefficientofforwardvoltagetoleranceis±0.1mV.
5. Vfminhotandmaxcoldvaluesareprovidedasreferenceonlyandarenotguaranteed.Thesevaluesareprovidedtoaidindriverdesignandselectionovertheoper-atingrangeoftheproduct.
7
Absolute Maximum Ratings
Table 3:MaximumDriveCurrentandReverseVoltageRatings
Parameter Maximum Rating
StorageTemperature -40°Cto+55°C
AmbientTemperature(Ta) 55°C
OperatingModuleCaseTemperature(Tc) 70°C
MaximumDriveCurrent1,2 1800mA
MaximumPeakPulsedDriveCurrent3 2580mA
MaximumReverseVoltage4 -20V
NotesforTable3:
1. Lumenmaintenance(L70)andlifetimepredictionsarevalidfordrivecurrentandcasetemperatureconditionsusedforLM-80testingasincludedintheapplicableLM-80testreportforthesearrays.ContactyourBridgeluxsalesrepresentativesforLM-80report.
2. OLMmodulesmaybedrivenathighercurrents.However,lumenmaintenancemaybereduced.
3. Bridgeluxrecommendsamaximumdutycycleof10%andpulsewidthof20mswhenoperatingOLMmodulesatmaximumpeakpulsedcurrentspecified.MaximumpeakpulsedcurrentsindicatevalueswhereLEDArrayscanbedrivenwithoutcatastrophicfailures.
4. OLMmodulesarenotdesignedtobedriveninreversevoltageandwillnotproducelightunderthiscondition.Maximumratingprovidedforreferenceonly.
8
Performance Curves
Figure 3: Typical DC ccy Shift vs. Case Temperature
0%
25%
50%
75%
100%
125%
150%
175%
200%
0 300 600 900 1200 1500 1800
Re
lati
ve
Flu
x
Drive Current (mA)
90%
92%
94%
96%
98%
100%
102%
0 10 20 30 40 50 60 70 80
Re
lati
ve
Flu
x
Case Temperature (°C)
Figure 1: Typical Relative Luminous Flux vs. Drive Current (Tc = 25°C)
NotesforFigure1.
1. TestedinpulsedconditionsatTc =25°C.Pulsewidthis10ms.
Figure 2: Typical DC Flux vs. Case Temperature
-0.0080
-0.0070
-0.0060
-0.0050
-0.0040
-0.0030
-0.0020
-0.0010
0.00000 10 20 30 40 50 60 70 80
cc
y S
hif
t
Case Temperature (°C)
25° C pulsed
5000 K, 70 CRI
-0.0050
-0.0045
-0.0040
-0.0035
-0.0030
-0.0025
-0.0020
-0.0015
-0.0010
-0.0005
0.00000 10 20 30 40 50 60 70 80
cc
x S
hif
t
Case Temperature (°C)
25° C Pulsed
5000 K, 70 CRI
Figure 4: Typical DC ccx Shift vs. Case Temperature
9
Optical Code DescriptionIES
ClassificationNEMA
ClassificationEN 13-201Guidance
A01A Asymmetric;Narrow,ShortWidth TypeII,Med 7Hx7V ME2-ME4
A06A Asymmetric;Medium,ShortWidth TypeIII,Short 7Hx7V ME2-ME4
Table 4: Optical Pattern Descriptions
Figure 5: Photometric Performance (Optical Code: A01A)
Figure 6: Photometric Performance (Optical Code: A06A)
Optical Characteristics
10
Figure 7: Mechanical Dimensions
NotesforFigure7:
1. Mountingholes(4x)accommodateM4or#8screws.
2. Screwswithflatshoulders(pan,dome,button,round,truss,mushroom)provideoptimaltorquecontrol.DoNOTuseflat,countersink,orraisedheadscrews.
3. Drawingdimensionsareinmillimeters.
4. Unlessotherwisespecified,tolerancesare±1.00mm.
5. RefertoApplicationNoteAN61forproducthandling,mountingandheatsinkrecommendations.
Mechanical Dimensions
11
Application Notes
Bridgelux has developed a comprehensive set of application notes and design resources to assist customersinsuccessfullydesigningwiththeOLMmodules.Foralistofresourcesunderdevelopment,visitwww.bridgelux.com.
Optical Files
Farfieldopticalfilesareavailablein.IESand.LDTformat.Con-tactyourBridgeluxsalesrepresentativefordetails.Pleaseuseappropriateprecautions.ItisimportantthatusersworkingwithLEDsaretrainedtousethemsafely.
MINOR PRODUCT CHANGE POLICY
TherigorousqualificationtestingonproductsofferedbyBridgeluxprovidesperformanceassurance.Slightcosmeticchangesthatdonotaffectform,fit,orfunctionmayoccurasBridgeluxcontinuesproductoptimization.
CAUTION: CHEMICAL EXPOSURE HAZARD
Exposuretosomechemicalscommonlyusedin luminairemanufacturingandassemblycancause damagetotheLEDarray.PleaseconsultBridgelux ApplicationNoteAN61foradditionalinformation.
CAUTION: EYE SAFETY
PleasecontactyourBridgeluxsalesrepresentativeforEyesafetyclassificationandIECspecifications.
3D CAD Models
ThreedimensionalCADmodelsdepictingtheproductoutlineareavailableinbothIGSandSTPformats.PleasecontactyourBridgeluxsalesrepresentativeforassis-tance.
CAUTION
CONTACT WITH OPTICAL AREA
TheOLMismanufacturedwithmoldedpolycarbonatelenses.Thelensisextremelydurable,butnotindestruc-tible.Excessiveforceonthelensmaycausedamagetothemodule.
CAUTION: RISK OF BURN
Donottouchthemodulelensduringoperation.Allowthemoduletocoolforasufficientperiodoftimebeforehandling.
Design Resources
Precautions
Disclaimers
12
About Bridgelux: We Build Light That Transforms
©2016Bridgelux,Inc.Allrightsreserved.Productspecificationsaresubjecttochangewithoutnotice.BridgeluxandtheBridgeluxstylizedlogodesignareregisteredtrademarks,OLMSeriesisatrademarkofBridgelux,Inc.Allothertrademarksarethepropertyoftheirrespectiveowners.
Bridgelux OLM Series Product Data Sheet DS60 Rev. C (11/2016)
101 Portola Avenue
Livermore, CA 94551
Tel (925) 583-8400
www.bridgelux.com
AtBridgelux,wehelpcompanies,industriesandpeopleexperiencethepowerandpossibilityoflight.Since2002,we’vedesignedLEDsolutionsthatarehighperforming,energyefficient,costeffectiveandeasytointegrate.Ourfocusisonlight’simpactonhumanbehavior,deliveringproductsthatcreatebetterenvironments,experiencesandreturns—bothexperientialandfinancial.Andourpatentedtechnologydrivesnewplatformsforcommercialandindustrialluminaires.
For more information about the company, please visit bridgelux.comtwitter.com/Bridgeluxfacebook.com/Bridgeluxhttps://www.linkedin.com/company/bridgelux-inc-_2WeChat ID: BridgeluxInChina
top related