carrier advantage automatic standby generators product catalog product cat.pdf · 2016. 5. 26. ·...
Post on 18-Sep-2020
0 Views
Preview:
TRANSCRIPT
A member of the United Technologies Corporation family.
Stock Symbol UTX.
© Carrier Corporation 2009 01-08AS-PA36-25
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs withoutnotice or without incurring obligations.
www.carrier.com 1-800-CARRIER
Automatic Standby Generators
Product Catalog
New Revolutionary Designs
Willis Carrier invented air conditioning in 1902. Over 100 years later, we’re proud to say Carrier systems are trusted in more
homes than any other brand.
Carrier continues to be on the forefront of innovative engineering and unsurpassed standards of excellence. So when
choosing a home comfort system, you’ll want to turn to the experts. Your Carrier dealer will evaluate your home, such as
window placement and size, ductwork, other structural specifics and lifestyle to provide a customized indoor comfort plan
designed specifically for you. And when you have an expert helping you make an educated decision, you’re going to feel
more comfortable.
Turn to the Experts
Are You Prepared to Handle a Power Outage?
Most people are not.
Don’t take your power for granted, be prepared with a Carrier automatic standby
generator.
Carrier automatic standby generators take the worry out of power outages.
Carrier provides peace of mind for home and business owners. No one else in
the industry can compare.
Whether you’re at home or away, your Carrier standby generator is ready to
assume control of your electrical needs when a power outage occurs. Within sec-
onds, back-up electricity is provided to your home or business, restoring essential
items such as lights, climate control, refrigeration, etc.
Unlike a portable generator, you don’t have to go outside, run a maze of extension
cords or bother with gasoline, because an automatic standby generator operates
on your LP or natural gas supply. Plus, when utility power returns, the generator
automatically shuts down and waits for the next outage.
Owning a Carrier standby generator has never been more convenient or afford-
able. Contact your local Carrier Dealer for pricing information.
How It Works
Once your standby generator has been installed outside of your home or business,
the automatic transfer switch is installed next to your main distribution panel.
With an air-cooled system, you identify the circuits you want to protect, then you
match those circuits on your distribution panel to the transfer switch’s load center.
Larger generators may protect all circuits with an appropriate transfer switch.
● The system provides monitoring of
incoming voltage from the utility line
around the clock.
● When utility power is interrupted, the
transfer switch senses the problem
and signals for the generator to
start.
● The automatic transfer switch will
then safely close off the utility line
and open a new power line from the
generator.
● Within seconds, your home standby
system will supply electricity to your
pre-selected circuits. When utility
line voltage returns, the transfer
switch will re-transfer the electrical
load back to the utility source and
resume monitoring for subsequent
utility loss.
Carrier Advantage
● Keep heating, air
conditioning, sump
pumps, refrigerators
and water heaters
operating
● Keep lines of com-
munication open
(telephone, televi-
sion and Internet)
● Keep lights, security
systems and cash
registers running
Peace of Mind
Rated Power LPG/NG kW 20 25 35 45 60 70 80 100 100 130 150Rated Amps @ 60Hz 120/240V, 1ø, 1.0pf N/A N/A N/A N/A 250 292 333 417 417 542 625120/208V, 3ø, 0.8pf 70 87 122 156 208 243 278 347 347 452 521277/480V, 3ø, 0.8pf N/A N/A 53 68 90 105 120 151 151 196 226Engine/Alternator RPM 3600/3600 3600/3600 3600/3600 3600/3600 3600/3600 1800/1800 3600/3600 3600/3600 2300/1800 3000/1800 3600/3600Engine 1.5L 1.6L 2.4L 2.4L 3.0L 6.8L 4.6L 5.4L 6.8L 6.8L 6.8LFuel ConsumptionLiquid propane cu. ft/hr (gal/hr) 125 (3.44) 183 (5.0) 222.3 (6.1) 286 (7.86) 376.3 (10.34) 411 (11.3) 442 (12.1) 553 (15.2) 507 (13.80) 719 (19.8) 830 (22.8)Natural gas cu. ft/hr 315 442 560 720 960 1020 1100 1374 1260 1786 2061Dimensions (L”xW”XH”)* 71x29.5x36 71x29.5x36 77x34x45 77x34x45 89x34x48* 116x37x55 116x37x55* 116x37x55* 116x37x55* 116x37x55* 116x37x55*Generator Weight (lbs.) Steel 1020 1025 1393 1414 1650 2185 2010 2311 2705 2873 2666
Aluminum 930 935 1276 1297 1513 2040 1836 2137 2531 2699 2492Required Transfer Switch RTS 100-200 RTS 100-200 RTS 100-200 RTS 100-200 RTS 100-200 HTS 150-400 HTS 150-400 HTS 200-600 HTS 200-600 HTS 200-600 HTS 300-800
*Height does not include measurement of exhaust stack.
Air-Cooled
Residential / 8, 10, 14 and 16 circuits
7-17kW
Pre-packaged system includes: 100 Amp automatic transfer
switch with load center, outdoor connection box, pre-wired
harness in conduit, flexible fuel line, composite mounting pad
and installation guide.
Sizing a Generator
When choosing the right generator, you must first decide how
many circuits or rooms in your home or small business you
should protect. The more circuits that require protection, the
larger the generator you need.
The automatic transfer switch in pre-packaged, air-cooled
systems allows you to match the system’s load center circuits
to the amperage in your home’s main distribution panel. (See
Fig. A). Simply determine which circuits to protect during an
outage and choose a generator.
For whole-house protection, Carrier’s liquid-cooled
residential / light commercial models range from 22-48kW.
To get accurate sizing requirements of a liquid-cooled gener-
ator, a licensed electrician will need to apply an amp meter to
the circuits and appliances that are intended to operate on
backup power.
Carrier air-cooled standby generators are designed to supply electricity to pre-selected circuits that supply a home’s
essential items in the event of a utility power outage. The pre-wired, pre-packaged system makes installation easy
and affordable.
● Breakthrough Design: Generates high starting power
to run the items that matter most.
● Circuit Coverage: Protects 16, 14, 10 or 8 circuits of
your home (17, 14, 10 and 8kW models respectively.)
● Industrial Engine: The longest life design and most
horsepower in its class.
● Superior Paint: Tough textured paint finish for
unmatched durability.
● Enclosure: Durable steel construction.
● Safe Design: UL listed / automatic voltage regulation
for sensitive electronics.
● Continuous Fuel: Models run on natural gas or liquid
propane gas.
● Ultra Quiet Mode (17kW only): Patent-pending self-test
feature allows the generator to exercise at reduced
rpm, decreasing sound output significantly.
Liquid-Cooled
Larger Residential / Light Commercial
22-48kW
Broadest line of generators on the market.
Higher wattage requirements need larger generators. This line of
standby generators is built for larger homes and small business.
Featuring automotive style, liquid-cooled engines and the exclusive
Ultra Quiet Mode feature, their greater power output and quiet
design makes for more complete and peaceful coverage during
an electrical outage.
● High Output: Liquid-cooled engine based models
produce more electricity for greater needs.
● Ultra Quiet Mode: Patent-pending self-test feature
allows the generator to exercise at reduced rpm,
decreasing sound output significantly.
● Enclosure Options: Steel or corrosion-resistant
aluminum enclosure for coastal communities.
● Superior Paint: Tough textured paint finish for
unmatched durability.
● Safe Design: UL listed / automatic voltage regulation
and electronic governor for sensitive electronics.
● Continuous Fuel: Models run on natural gas or liquid
propane gas.
● Transfer Switches: See transfer switch section for
selection of 100 and 200 Amp, single-phase switch
gear.
17-20kW
The system includes: composite mounting pad and installation guide.
Breakthrough Design
The exclusive Ultra Quiet Mode feature allows the generator to
exercise at reduced rpm, decreasing sound output significantly.
● Breakthrough Design: Generates high starting power
to run the items that matter most.
● Ultra Quiet Mode: Patent-pending self-test feature
allows the generator to exercise at reduced rpm,
decreasing sound output significantly.
● Industrial Engine: The longest life design and most
horsepower in its class.
● Enclosure: Corrosion-resistant aluminum enclosure.
● Application Flexibility: Gives the option of complete
back-up or load management system.
● Superior Paint: Tough textured paint finish for
unmatched durability.
● Safe Design: UL listed / automatic voltage regulation
and electronic governor for sensitive electronics.
● Continuous Fuel: Models run on natural gas or liquid
propane gas.
● Transfer Switches: See transfer switch section for
selection of 100 and 200 Amp, single-phase
switch gear.
Bedroom
Bedroom
Family Room
Deck
Kitchen
Garage
Bath
Master
Bedroom
Dining
Room
Utility
Room
Walk-In
Closet
Master
Bath
Circuit
Bath
A/C Unit Circuit
(up to 5 ton)
Furnace
Water Heater
Sump Pump
Home Office
(in basement)
Commercial Series
Commercial / Light Industrial
20-150kW
Continuous standby power for every application.
Carrier commercial series standby generators offer
restaurants, gas stations, offices and other businesses
maximum blackout protection for minimal investment.
Models range in output from 20 to 150kW and offer a
choice of voltage outputs with higher amperage
transfer switches. Transfer switches sold separately.
See required transfer switches in the chart below.
● Ultra Quiet Mode: Patent-pending self-test feature
allows the generator to exercise at reduced rpm,
decreasing sound output significantly.
● Superior Paint: Tough textured paint finish for
unmatched durability.
● Safe Design: UL listed / automatic voltage regula-
tion and electronic governor for sensitive elec-
tronics.
● Continuous Fuel: Models run on natural gas or
liquid propane gas.
Transfer Switches
100-200 AMP (Single-phase)
● No service disconnect
● Installations with sub panel
● Custom installations
● Aluminum enclosure
100-200 AMP (Single-phase)
● With service disconnect
● Service entrance rated
● Economical installation
● Aluminum enclosure
For Carrier commercial models.
100-400 AMP - Designed for applications
requiring up to 400 Amps.
HTS 200-800 AMP - Designed for simple
monitoring, operation and maintenance.
Removable and adjustable components
for serviceability.
20-25kW
35-45kW
60kW
80-150kW
KGAT
KGALT
HTS-N
70kW
Figure B is an example of the circuits that can be protected
with a 16kW (16 circuits) pre-packaged air-cooled generator.
Note: Rooms and appliances are shown as example only. You may choose other items that
better fit your needs. Due to the cycling nature of some appliances, all items may not be able
to run simultaneously.
* A 240V 2-pole circuit breaker is equal to two circuits.
Model Amps Volts EnclosureHTS-N-150K 150 277/480V 3ø NEMA 1 or 3R HTS-N-200K 200 277/480V 3ø NEMA 1 or 3RHTS-N-300A 300 120/240V 1ø NEMA 1 or 3RHTS-E-300G 300 120/208V 3ø NEMA 1 or 3RHTS-N-300K 300 277/480V 3ø NEMA 1 or 3RHTS-N-400A 400 120/240V 1ø NEMA 1 or 3RHTS-N-400G 400 120/208V 3ø NEMA 1 or 3RHTS-N-400K 400 277/480V 3ø NEMA 1 or 3RHTS-N-600A 600 120/240V 1ø NEMA 12 or 3RHTS-N-600G 600 120/208V 3ø NEMA 12 or 3RHTS-N-600K 600 277/480V 3ø NEMA 12 or 3RHTS-N-800A 800 120/240V 1ø NEMA 12 or 3RHTS-N-800G 800 120/208V 3ø NEMA 12 or 3RHTS-N-800K 800 277/480V 3ø NEMA 12 or 3R
ModelsTypical Loads Circuits 8kW 10kW 14kW 17kWA/C (4-ton) (40 Amp/240V)* •A/C (3-ton or smaller) (30 Amp/240V)* • •Well Pump or Water Heater (20 Amp/120V) • • • •Family Room (20 Amp/120V) • • • •Master Bedroom (20 Amp/120V) • • •Home Office (20 Amp/120V) • •Garage (20 Amp/120V) • • •Kitchen (#1) (20Amp/120V) • •Kitchen (#2) (15 Amp/120V) • • •Bathroom (15 Amp/120V) • • • •Furnace (15 Amp/120V) • • • •Sump Pump (15 Amp/120V) • • • •Bedrooms (15 Amp/120V) • • • •
Number of Circuits Covered 8 10 14 16
Figure A
Model Amps Volts Enclosure Service DisconnectKGATD0401100 100 120/240V NEMA 3R YesKGATX0201100 100 120/240V NEMA 3R NoKGATD0401200 200 120/240V NEMA 3R YesKGATX0201200 200 120/240V NEMA 3R NoKGATX0101400 400 120/240V NEMA 3R NoKGALT0101200 200* 120/240V NEMA 3R Yes
Model ASPDS1XXA008 ASPDS1XXA010 ASPDS1XXA014 ASPDS1XXA017 ASPDY1XXA017 ASPDY1XXA020 ASPFY1XXL022 ASPFX1XXL025 ASPFY1XXL027 ASPFX1XXL030 ASPFY1XXL036 ASPFX1XXL045 ASPFY1XXL048
Rated Power (LPG/NG) kW 8/7 10/9 14/13 17/16 17/16 20/18 22/22 25/24 27/25 30/29 35/35 45/43 45/42Voltage (single-phase) 120/240V 120/240V 120/240V 120/240V 120/240V 120/240V 120/240V 120/240V 120/240V 120/240V 120/240V 120/240V 120/240VAmps @ 120/240V LPG 66.6/33.3 83.3/41.6 116.6/58.3 141.6/70.8 141.6/70.8 166.6/83.3 184/92 208.3/104.2 224/112 250/125 291.6/145.8 375/187.5 375/187.5Amps @ 120/240V NG 58.3/29.2 75/37.5 108.3/54.2 133.3/66.6 133.3/66.6 150.0/75.0 184/92 208.3/104.2 224/112 241.6/120.8 291.6/145.8 358.3/179.2 358.3/179.2Engine/Alternator RPM 3600/3600 3600/3600 3600/3600 3600/3600 3600/3600 3600/3600 1800/1800 3600/3600 1800/1800 3600/3600 1800/1800 3600/3600 1800/1800Engine OHVI/410cc OHVI/530cc OHVI/992cc OHVI/992cc OHVI/992cc OHVI/999cc In-line 4 cyl. In-line 4 cyl. In-line 4 cyl. In-line 4 cyl. V-6 In-line 4 cyl. V-6 Fuel Consumption @ full loadLiquid Propane cu. ft/hr (gal/hr) 54 (1.47) 70 (1.93) 80 (2.18) 92 (2.51) 92 (2.51) 103.5 (2.85) 120 (3.3) 175 (4.8) 147 (4.1) 209 (5.7) 185 (5.1) 286 (7.86) 240 (6.6)Natural Gas cu. ft/hr 119 156 220 245 245 262 316 437 359 525 485 720 630Ultra Quiet Mode No No No Yes Yes Yes N/A Yes Yes Yes Yes Yes YesAutomatic Transfer Switch 100 Amp 100 Amp 100 Amp 100 Amp N/A N/A N/A 200ALT N/A N/A N/A N/A N/ACircuits Protected 8 10 14 16 N/A N/A N/A N/A N/A N/A N/A N/A N/ADimensions (L”xW”xH”) 48x25x29 48x25x29 48x25x29 48x25x29 48x25x29 48x25x29 62x29x33.5 71x29.5x36 62x29x33.5 62x29x33.5 77x33.5x45 77x33.5x45 77x33.5x45Generator Weight (lbs.) 336 375 425.5 445 414 451 843 1025 891 935 1683 1414 1703Enclosure Steel Steel Steel Steel Aluminum Aluminum Aluminum Steel Aluminum Steel Aluminum Steel Aluminum
* 200A load management with 16 circuit load center.