case study: subsea pump pump condition monitoring

Post on 24-Feb-2022

4 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Pioneering Innovation in Optical Fiber Sensing Pioneering Optical Fibre Sensing

Case Study: Subsea pump Pump Condition

Monitoring 2007-2010

© Smart Fibres Ltd

1

Partners: Smart Fibres, Flowserve, SKF, Teledyne ODI Project Sponsor: Shell Upstream Americas – Deepwater Platform: Subsea twin-screw pump and motor Objective: Develop fibre optic condition monitoring Why fibre: Harsh environment, no subsea electronics

© Smart Fibres Ltd

2

18 motor temperature sensors

© Smart Fibres Ltd

3

Pump lube oil pressure & temperature

© Smart Fibres Ltd

4

Bearing housing tri-axis acceleration

© Smart Fibres Ltd

5

Bearing condition monitoring (with SKF)

© Smart Fibres Ltd

6

Bearing loads match FE model within 5%

© Smart Fibres Ltd

7

10 kHz raw data. Odd signal on one roller

Enveloping shows defect. Time period = cage speed

© Smart Fibres Ltd

8

Enveloping of FFT

Healthy bearing

Damage bearing

© Smart Fibres Ltd

9

Data analysis predicted: 3.0 mm scratch length, minimal scratch depth

© Smart Fibres Ltd

10

Inspection found… 3mm scratch length, and 2 micron scratch depth

© Smart Fibres Ltd

11

Image c/o Shell

on a bearing inside here

visible on an instrument here

A 2 micron scratch here

+44 1344 484111 info@smartfibres.com smartfibres.com Smart Fibres Ltd, Spectrum House, Brants Bridge, Bracknell, RG12 9BG, United Kingdom

Pioneering Optical Fibre Sensing

Thank You

top related