Configuration Manual
Auto Tracking System
Auto Tracking Sytem1
DOC-000064 Arch. 4914 26/08/2015
Auto Tracking System2
DOC-000064 Arch. 4914 26/08/2015
VideoVideoAudioAudioDataData
Auto Tracking System3
DOC-000064 Arch. 4914 26/08/2015
1 2 3 4 5Device
SiteEK-MFR/2 EK-MFR/Fly EK-HCT/4 EK-HCT/4-I EK-UNM/3 EK-UCM/x EK-AMP/x EK-DCM/x
BranchingSystem
EK-CDP/2Tx
ODURx
ODU
OutdoorBranching
SystemEK-TPN/120 EK-ALH/1
RFAntenna
RadioModemRadioModem
AntennaGPS
AntennaADS-B
Antenna
Fix SiteTX ● ● ● ● ● ● ● ● ● ●(1)* ●(1)* ●(2)*RX ● ● ● ● ● ● ● ● ● ●(1)* ●(1)* ●(2)*
RTX ● ● ● ● ● ● ● ● ● ● ● ●(1)* ●(1)* ●(2)*
OBVanTX ● ●* ● ● ● ● ●* ●* ● ●(1)* ● ●(2)*RX ● ●* ● ● ● ● ●* ●* ● ●(1)* ● ●(2)*
RTX ● ●* ● ● ● ● ● ● ●* ●* ● ●(1)* ● ●(2)*
MotorcycleTX ● ● ● ● ●* ● ● ●(1)* ●(1)* ●RX ● ● ● ● ●
AircraftTX ●(3) ●(3) ● ● ● ● ● ●(1)* ●RX ●(3) ●(3) ● ● ● ● ● ●(1)* ●
RTX ●(3) ●(3) ● ● ● ● ● ● ●(1)* ●
* Optional1. Link to/from mobile unit (i.e. aircraft)2. Link to/from aircraft3. One exclude the other
Device Description NoteEK-MFR/2 1RU 6 slots Modular Frame with on-board Controller and redundant hot-swappable SMPS(see Table 1 for available SMPS units) Needed to install different kind of boards to be used in a fixed rackEK-MFR/Fly Avionic/Mobile 8 slots Modular Frame Needed to install different kind of boards in a mobile frameEK-MFR/3 Controller plug-in board for Modular Frames Controller to be used with EK-MFR/FlyEK-HCT/4 Tracking Controller plug-in board equipped with geodata processor, RadioModem I/F, Pan/Tilt positioner I/F, ADS-B receiver (optional)EK-HCT/4-I Tracking Controller plug-in board equipped with geodata processor, RadioModem I/F, Pan/Tilt positioner I/F, Inertial Measurement Unit, Magnetic
Compass, Barometer, ADS-B receiver (optional)EK-UNM/3 QAM Modem plug-in board with GbE, 2 ASI outputs, 2 ASI inputsEK-UCM/x Agile Up-Converter plug-in board (see Table 2 for frequency band availability)
EK-AMP/x RF Power Amplifier plug-in board (see Table 3 for frequency band availability)
EK-DCM/x Agile Down-Converter plug-in board (see Table 4 for frequency band availability)
Branching System Filters assembly for filtering and/or combining Tx and Rx
EK-CDP/2 Coaxial Adapter plug-in board for Tx and Rx OutDoor Units (ODUs)
Tx ODU Agile Transmitter Out Door Unit with medium and high power option (see Table 5 for frequency band availability)Rx ODU Agile Receiver Out Door Unit (see Table 6 for frequency band availability)Outdoor Branching System Assembly for combining Tx and Rx ODUs
EK-TPN/120 Heavy Duty High Reliability Pan/Tilt positionerEK-ALH/1 1RU Power Supply Unit for EK-TPN/120RF Antenna Microwave Antenna (see Tables 7)RadioModem NEXEDGE VHF/UHF Digital Mobile Radio (see Table 8)RadioModem Antenna (see Table 9)GPS Antenna GPS Active Antenna (see Table 10)ADS-B Antenna Heavy Duty Active Collinear ADS-B Antenna Used to receive location data from aircraft compliant with Mode S ADS-B technology
Auto Tracking Sytem4
DOC-000064 Arch. 4914 26/08/2015
Table 1 – SMPS units
Unit Description Code
EK-PWS/A AC power supply plug-in board (85 ÷ 264 Vac) 601-000962
EK-PWS/D DC power supply plug-in board (20 ÷ 75 Vdc) 601-000963
Note: EK-MFR/2 unit can holds one or two SMPS units.
Table 2 – Up converter frequency bands
Frequency Band (MHz) Equipment Code
2300 ÷ 2700 EK-UCM/2 601-000333
3230 ÷ 3830 EK-UCM/4L 601-001304
3600 ÷ 4200 EK-UCM/3 601-001303
3930 ÷ 4440 EK-UCM/4H 601-001305
4400 ÷ 4900 EK-UCM/4 601-000138
5200 ÷ 5400 EK-UCM/5 601-000375
5900 ÷ 6400 EK-UCM/59 601-000509
6400 ÷ 7200 EK-UCM/6 601-000379
7000 ÷ 8000 EK-UCM/7 601-000377
7700 ÷ 8500 EK-UCM/8 601-000365
10000 ÷ 10900 EK-UCM/10 601-000479
10700 ÷ 11700 EK-UCM/11 601-000369
11700 ÷ 12500 EK-UCM/12 601-000367
12700 ÷ 13300 EK-UCM/13 601-000373
13700 ÷ 14500 EK-UCM/14 601-000370
14500 ÷ 15250 EK-UCM/15 601-001302
Table 3 – Down converter frequency bands
Frequency Band (MHz) Equipment Code
2300 ÷ 2700 EK-DCM/2 601-000334
3230 ÷ 3830 EK-DCM/4L 601-001308
3600 ÷ 4200 EK-DCM/3 601-001307
3930 ÷ 4440 EK-DCM/4H 601-001309
4400 ÷ 4900 EK-DCM/4 601-000137
5200 ÷ 5400 EK-DCM/5 601-000374
5900 ÷ 6400 EK-DCM/59 601-000510
6400 ÷ 7200 EK-DCM/6 601-000378
7000 ÷ 8000 EK-DCM/7 601-000376
7700 ÷ 8500 EK-DCM/8 601-000364
10000 ÷ 10900 EK-DCM/10 601-000508
10700 ÷ 11700 EK-DCM/11 601-000368
11700 ÷ 12500 EK-DCM/12 601-000366
12700 ÷ 13300 EK-DCM/13 601-000372
13700 ÷ 14500 EK-DCM/14 601-000370
14500 ÷ 15250 EK-DCM/15 601-001306
Table 4 – RF Power Amplifier frequency bands
Frequency Band (MHz) Equipment Code
2300 ÷ 2700 EK-AMP/2 601-000299
5200 ÷ 5400 EK-AMP/5 601-000579
5900 ÷ 6400 EK-AMP/59 601-000360
6400 ÷ 7200 EK-AMP/6 601-000578
7000 ÷ 8000 EK-AMP/7 601-000575
7700 ÷ 8500 EK-AMP/8 601-000574
10000 ÷ 10900 EK-AMP/1 601-000590
10700 ÷ 11700 EK-AMP/11 601-000573
11700 ÷ 12500 EK-AMP/12 601-000572
12700 ÷ 13300 EK-AMP/13 601-000571
13700 ÷ 14500 EK-AMP/14 601-000570
14500 ÷ 15250 EK-AMP/15 601-001310
Auto Tracking Sytem5
DOC-000064 Arch. 4914 26/08/2015
Table 5 – Agile Transmitter Out Door Unit frequency bands
Frequency Band (MHz) Equipment Code
2300 ÷ 2700 A4D-ES2T/1 601-001018
3230 ÷ 3830A4D-ES4LT/1 601-001311
A4D-ES4LT/1H * 601-001312
3600 ÷ 4200A4D-ES3T/1 601-000038
A4D-ES3T/1H * 601-001313
3930 ÷ 4440A4D-ES4HT/1 601-001314
A4D-ES4HT/1H * 601-001315
4400 ÷ 4900A4D-ES4T/1 601-001316
A4D-ES4T/1H * 601-001317
5200 ÷ 5400A4D-ES5T/1 601-000954
A4D-ES5T/1H * 601-001318
5900 ÷ 6400A4D-ES59T/1 601-000978
A4D-ES59T/1H * 601-001319
6400 ÷ 7200A4D-ES6T/1 601-000178
A4D-ES6T/1H * 601-000009
7000 ÷ 8000A4D-ES7T/1 601-000028
A4D-ES7T/1H * 601-001320
8000 ÷ 8500A4D-ES8T/1 601-000956
A4D-ES8T/1H * 601-001321
10000 ÷ 10900A4D-ES10T/1 601-000259
A4D-ES10T/1H * 601-001322
10700 ÷ 11700A4D-ES11T/1 601-000018
A4D-ES11T/1H * 601-001323
11700 ÷ 12500A4D-ES12T/1 601-001324
A4D-ES12T/1H * 601-001239
12700 ÷ 13300A4D-ES13T/1 601-000096
A4D-ES13T/1H * 601-001288
13700 ÷ 14500A4D-ES14T/1 601-000972
A4D-ES14T/1H * 601-001325
14500 ÷ 15250A4D-ES15T/1 601-001326
A4D-ES15T/1H 601-001327
17700 ÷ 18000 A4D-ES181T/1 601-000475
18000 ÷ 18400 A4D-ES182T/1 601-001201
18400 ÷ 18700 A4D-ES183T/1 601-000517
18700 ÷ 19000 A4D-ES184T/1 601-000518
19000 ÷ 19400 A4D-ES185T/1 601-001328
19400 ÷ 19700 A4D-ES186T/1 601-001329
21100 ÷ 21400 A4D-ES23L1T/1 601-000626
21200 ÷ 21500 A4D-ES23L2T/1 601-000120
21500 ÷ 21800 A4D-ES23L3T/1 601-000121
21800 ÷ 22100 A4D-ES23L4T/1 601-000122
22000 ÷ 22300 A4D-ES23H6T/1 601-000124
22100 ÷ 22400 A4D-ES23H1T/1 601-000123
22300 ÷ 22600 A4D-ES23H7T/1 601-000131
22400 ÷ 22700 A4D-ES23H2T/1 601-000130
22700 ÷ 23000 A4D-ES23H3T/1 601-000132
23000 ÷ 23300 A4D-ES23H4T/1 601-000133
23300 ÷ 23600 A4D-ES23H5T/1 601-000134
* High Power version
Auto Tracking System6
DOC-000064 Arch. 4914 26/08/2015
Table 6 – Agile Receiver Out Door Unit frequency bands
Frequency Band (MHz) Equipment Code
2300 ÷ 2700 A4D-ES2R/1 601-001338
3230 ÷ 3830 A4D-ES4LR/1 601-001330
3600 ÷ 4200 A4D-ES3R/1 601-000037
3930 ÷ 4440 A4D-ES4HR/1 601-001331
4400 ÷ 4900 A4D-ES4R/1 601-001332
5200 ÷ 5400 A4D-ES5R/1 601-000953
5900 ÷ 6400 A4D-ES59R/1 601-000977
6400 ÷ 7200 A4D-ES6R/1 601-000177
7000 ÷ 8000 A4D-ES7R/1 601-000029
8000 ÷ 8500 A4D-ES8R/1 601-000955
10000 ÷ 10900 A4D-ES10R/1 601-000260
10700 ÷ 11700 A4D-ES11R/1 601-000017
11700 ÷ 12500 A4D-ES12R/1 601-001333
12700 ÷ 13300 A4D-ES13R/1 601-000095
13700 ÷ 14500 A4D-ES14R/1 601-000971
14500 ÷ 15250 A4D-ES15R/1 601-001334
17700 ÷ 18000 A4D-ES181R/1 601-000476
18000 ÷ 18400 A4D-ES182R/1 601-001200
18400 ÷ 18700 A4D-ES183R/1 601-000336
18700 ÷ 19000 A4D-ES184R/1 601-000337
19000 ÷ 19400 A4D-ES185R/1 601-001335
19400 ÷ 19700 A4D-ES186R/1 601-001336
21100 ÷ 21400 A4D-ES23L1R/1 601-001337
21200 ÷ 21500 A4D-ES23L2R/1 601-000115
21500 ÷ 21800 A4D-ES23L3R/1 601-000116
21800 ÷ 22100 A4D-ES23L4R/1 601-000117
22000 ÷ 22300 A4D-ES23H6R/1 601-000119
22100 ÷ 22400 A4D-ES23H1R/1 601-000118
22300 ÷ 22600 A4D-ES23H7R/1 601-000126
22400 ÷ 22700 A4D-ES23H2R/1 601-000125
22700 ÷ 23000 A4D-ES23H3R/1 601-000127
23000 ÷ 23300 A4D-ES23H4R/1 601-000128
23300 ÷ 23600 A4D-ES23H5R/1 601-000129
Table 7a – Parabolic Antennas
Frequency Band (MHz) Diameter Equipment Code
2300 ÷ 2700 60 cm EK-T60L/2 601-000661
5000 ÷ 6000 60 cm EK-T60L/5 601-000660
5900 ÷ 6400 60 cm EK-T60L/59 601-000979
6400 ÷ 720060 cm EK-T60L/7 601-000659
90 cm EK-T90L/7 601-000530
7700 ÷ 8500 60 cm EK-T60L/8 601-000297
10000 ÷ 15000 60 cm EK-T60L/1 601-000679
Table 8 – Radio Modem models
Model Frequency Band Code
NX-700 136 ÷ 174 MHz 601-001339
NX-800-1 450 ÷ 520 MHz 601-001340
NX-800-2 400 ÷ 470 MHz 601-001341
Table 9 – Radio Modem antennas
Model Type Gain Frequency Band Code
SPO 145-2 Dipole 2 dBi 145 ÷ 175 MHz 601-001342
WY140-2N 2 elements Yagi 5 dBi 140 ÷160 MHz 601-001343
WY155-2N 2 elements Yagi 5 dBi 155 ÷ 175 MHz 601-001344
Auto Tracking Sytem7
DOC-000064 Arch. 4914 26/08/2015
Table 10 – GPS Antennas
Model Code
ANT-GPSMG 1.0/2.3 601-001345
Auto Tracking System8
DOC-000064 Arch. 4914 26/08/2015