OVERVIEWThe DTS is a dimming bypass module used with an inverter or generator in emergency systems. The DTS works by constantly sensing for the presence of utility power. When utility power is no longer sensed (during a power outage), the DTS will bypass any dimming or controls integral to or networked with the fixture. Fixtures that can be dimmed must return to an undimmed (or pre-determined) state with loss of utility power, to meet UL924 requirements.
LUMINAIRE USEThe DTS cannot be used in conjunction with GTD, ATSD or ELL14/40 (Emergency Battery Pack) options. Each luminaire has different restrictions of use, please check individual specification sheets for compatibility. The DTS is available only as a factory-installed option.
EMERGENCY CIRCUITSWhile the DTS is UL924 listed, it is not used to transfer power. The transfer of power must happen through a UL1008 module, (such as an AETS – Automatic Emergency Transfer Switch), to meet building code. The DTS is to be used in conjunction with an emergency AC power supply, such as an inverter or generator.
These systems are designed/specified by qualified professionals.
CONNECTIONS FROM FIXTURE TO BUILDING SYSTEMThe following 10 cases are outlined in the included wiring diagram package if further information is needed. The following outlines key connections to perform when installing new fixtures, as well as wiring internal to the fixture.
© 2019 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd • Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
Page 2/9 Rev. 08/21/19COL-DTS-IMP
DTS Dimming Bypass ModuleSYSTEM LAYOUT EXAMPLES
Integration Guide
Utility Power
Un-Switched
Emergency Line
Switched
Switched
Transfer Switch (AETS) (UL1008 Device)
1
2
3
4
Luminaire with In-Fixture Control
Luminaire with In-Fixture Control
DTS Enabled Luminaire with In-Fixture Control
DTS Enabled Luminaire with In-Fixture Control
Refer to wiring diagrams for speci�c cases
EmergencyAC Power
SITUATION 1: NORMAL UNDIMMED OPERATION• Each luminare has in-fixture control and is not dimmed• Luminaires 3 & 4 are also emergency enabled with DTS modules
EXAMPLE OF BASIC SYSTEM LAYOUT
Emergency Line
Switched
50% Dim
50% Dim
Utility Power
Un-Switched
Switched
Transfer Switch (AETS) (UL1008 Device)
1
2
3
4
Luminaire with In-Fixture Control
Luminaire with In-Fixture Control
DTS Enabled Luminaire with In-Fixture Control
DTS Enabled Luminaire with In-Fixture Control
EmergencyAC Power
Emergency Line
Switched
Utility Power
(Resumes to undimmed state)
Un-Switched
Switched
Transfer Switch (AETS) (UL1008 Device)
1
2
3
4
Luminaire with In-Fixture Control
Luminaire with In-Fixture Control
DTS Enabled Luminaire with In-Fixture Control
DTS Enabled Luminaire with In-Fixture Control
EmergencyAC Power
Below are 3 situations of a system layout using a DTS module*Specific layouts may vary
SITUATION 1 (below)Normal Undimmed Operation
SITUATION 2 (pg. 3)Dimmed Operation
SITUATION 3 (pg. 4)Emergency Operation
Utility Power
Un-Switched
Emergency Line
Switched
Switched
Transfer Switch (AETS) (UL1008 Device)
1
2
3
4
Luminaire with In-Fixture Control
Luminaire with In-Fixture Control
DTS Enabled Luminaire with In-Fixture Control
DTS Enabled Luminaire with In-Fixture Control
Refer to wiring diagrams for speci�c cases
EmergencyAC Power
© 2019 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd • Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
Page 3/9 Rev. 08/21/19COL-DTS-IMP
DTS Dimming Bypass ModuleSYSTEM LAYOUT EXAMPLES
Integration Guide
Emergency Line
Switched
50% Dim
50% Dim
Utility Power
Un-Switched
Switched
Transfer Switch (AETS) (UL1008 Device)
1
2
3
4
Luminaire with In-Fixture Control
Luminaire with In-Fixture Control
DTS Enabled Luminaire with In-Fixture Control
DTS Enabled Luminaire with In-Fixture Control
EmergencyAC Power
SITUATION 2: NORMAL UTILITY POWER OPERATION, INDIVIDUAL DIMMING CONTROL• Luminaires 1 & 3 are in a dimmed state by user choice
© 2019 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd • Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
Page 4/9 Rev. 08/21/19COL-DTS-IMP
DTS Dimming Bypass ModuleSYSTEM LAYOUT EXAMPLES
Integration Guide
Emergency Line
Switched
Utility Power
(Resumes to undimmed state)
Un-Switched
Switched
Transfer Switch (AETS) (UL1008 Device)
1
2
3
4
Luminaire with In-Fixture Control
Luminaire with In-Fixture Control
DTS Enabled Luminaire with In-Fixture Control
DTS Enabled Luminaire with In-Fixture Control
EmergencyAC Power
SITUATION 3: LOSS OF UTILITY POWER• Transfer switch will transfer power from utility to emergency power source• Luminaires 1 & 2 lose power • DTS opens dimming circuits in luminaires 3 & 4 which then resume their undimmed state to meet
UL924 requirements
DTS Dimming Bypass ModuleWIRING DIAGRAMS
© 2019 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd • Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
Page 5/9 Rev. 08/21/19COL-DTS-IMP
Integration Guide
DTS/NXFM-O/I
DRIVER
WHITE
WHITEBLACK
REDBLUE
GRAY
ORANGE
VIOLET
SMALL YELLOW (CAPPED)
TO LED BOARD(S)
GND
WHITE/BLUE
YELLOW
BLUE
BLACK
WHITE/BLUE
TO EMERGENCY
NXFM-O
RED
REDWHITE
BLACK
FERRITE CHOKE
1 LOOPOF WHT & BLK WIRE AROUND CHOKE
TO UTILITY
TO EMERGENCY
VIOLET
KEYColor Connects WithWhite/Blue Emergency NeutralBlue Emergency LineBlack Utility line (Unswitched Hot)White Utility Neutral
CASE 2: DTS WITH INTERNAL NXFM-O OR NXFM-I
DTS
DRIVER
WHITE
WHITEBLACK
RED
REDBLUE
GRAYVIOLET
VIOLET
ORANGE
SMALL YELLOW (CAPPED)
TO LED BOARD(S)
TO DIMMING
GND
TO UTILITY
WHITE/BLUE
YELLOW
BLUE
WHITE/BLUE
TO EMERGENCY
TO EMERGENCY
BLACK
KEY
Color Connects WithWhite/Blue Emergency NeutralBlue Emergency LineBlack Utility line (Unswitched Hot)White Utility NeutralRed Switched HotViolet Dimming Gray Dimming
CASE 1: DTS WITH EXTERNAL DIMMING CONTROL
DTS Dimming Bypass ModuleWIRING DIAGRAMS
© 2019 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd • Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
Page 6/9 Rev. 08/21/19COL-DTS-IMP
Integration Guide
DTS/CTC
DRIVER
WHITE
WHITEBLACK
BLACK
REDBLUE
GRAYVIOLET
VIOLET
ORANGE
SMALL YELLOW (CAPPED)
TO DIMMING
GND
TO UTILITY
WHITE/BLUE
YELLOW
BLUE
RED
WHITE/BLUE
TO EMERGENCY
TO EMERGENCY
NEGPOSNEGPOS
CH1 NEGCH2 NEGCH1 POSCH2 POS
LED0-10V
DRIVER
CTCREDBLUE
WHITE/BLUE
TO LED BOARD(S)
VIOLETGRAY
TO CTC DIMMING
KEY
Color Connects WithWhite/Blue Emergency NeutralBlue Emergency LineBlack Utility line (Unswitched Hot)White Utility NeutralRed Switched HotViolet Dimming Gray Dimming
CASE 4: DTS WITH INTERNAL CTC MODULE FOR SpectraSync™
DTS/NXFM-LV
WHITERED
VIOLET
SMALL YELLOW (CAPPED)
TO UTILITY
WHITE/BLUE
BLUE
BLACK
WHITE/BLUE
WHI
TE
TO EMERGENCYDIM 1+DIM 2+
COM+12V
NHG
+-
+- DIM
LED
AUX
YELLOW
GND
GRA
Y
YEL L
OW
ORA
NGE
VIOLET
GRA
Y
RED
BLUEBLUE
TO LED BOARD(S)
BLACK
NXCBL-I TO:NXSMP SENSOR AND/ORNXRM-H RADIO MODULE AND/ORNXDSP/NXFSP SMART PORT
KEY
Color Connects With
White/Blue Emergency Neutral
Blue Emergency LineBlack Utility line (Unswitched Hot)White Utility NeutralRed Switched Hot
CASE 3: DTS WITH INTERNAL NXFM-LV
DTS Dimming Bypass ModuleWIRING DIAGRAMS
© 2019 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd • Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
Page 7/9 Rev. 08/21/19COL-DTS-IMP
Integration Guide
WHITE BLACKVIOLET
ORANGE
SMALL YELLOW (CAPPED)
TO UTILITY
WHITE/BLUE
BLUE
YELLOW
RED
WHITE/BLUE
N
+- E2
L
E1
WHI
TEBL
UE
E1 LABELE2 LABEL
VIOLET
VIOLET
GRAY
CAP INSIDE FIXTURE
CAP INSIDE FIXTURE
CAP INSIDE FIXTURE
REDBLUE
TO LED BOARD(S)
BLUE
TO EMERGENCY
TO DIMMING
DTS LUTRON H/5 SERIES
KEY
Color Connects With
White/Blue Emergency NeutralBlue Emergency LineBlack Utility line (Unswitched Hot)White Utility NeutralRed Switched HotViolet Dimming Gray Dimming
CASE 6: DTS WITH LUTRON H SERIES DRIVER OR LUTRON 5 SERIES DRIVER
DTS/NX/CTC
DRIVER
WHITE
WHITEBLACK
GRAY
ORANGE
VIOLET
SMALL YELLOW (CAPPED)
GND
WHITE/BLUE
YELLOW
BLUE
BLACK
WHITE/BLUE
TO EMERGENCY
NXFM-O
RED
REDWHITE
BLACK
FERRITE CHOKE
1 LOOPOF WHT & BLK WIRE AROUND CHOKE
TO UTILITY
TO EMERGENCY
RED
NEGPOSNEGPOS
CH1 NEGCH2 NEGCH1 POSCH2 POS
LED0-10V
DRIVER
CTCREDBLUE
WHITE/BLUE
TO LED BOARD(S)
VIOLET
VIOLET/WHITE
GRAYGRAY
BLUE
KEY
Color Connects WithWhite/Blue Emergency NeutralBlue Emergency LineBlack Utility line (Unswitched Hot)White Utility Neutral
CASE 5: DTS WITH INTERNAL CTC AND NXFM-O OR NXFM-I FOR SpectraSync™ USED WITH NX
DTS Dimming Bypass ModuleWIRING DIAGRAMS
© 2019 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd • Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
Page 8/9 Rev. 08/21/19COL-DTS-IMP
Integration Guide
DTS/ODPG
WHITERED
VIOLET
TO UTILITY
WHITE/BLUE
BLUE
BLACK
WHITE/BLUE
WHI
TE
YELLOW
GND
RED
ORANGECAP INSIDE FIXTURE
NHG
+- LED
+-
SRSRBLUE
TO LED BOARD(S)
BROWN
BROWN
VIOLET
SMAL
L YE
LLO
W
VIOLET
BRO
WN
TO EMERGENCY
KEY
Color Connects With
White/Blue Emergency NeutralBlue Emergency LineBlack Utility line (Unswitched Hot)White Utility NeutralRed Switched Hot
CASE 8: DTS WITH INDIVIDUAL FIXTURE ODPG SENSOR
DTS/LVR/LVS
WHITERED
VIOLET
TO UTILITY
WHITE/BLUE
BLUE
BLACK
WHITE/BLUE
WHI
TE
TO EMERGENCYYELLOW
GND
RED
ORANGECAP INSIDE FIXTURE
NHG
+- LED
+-
SRSRBLUE
TO LED BOARD(S)
BROWN
BROWN
VIOLET
SMAL
L YE
LLO
W
VIOLET
BLUE
BLUE
KEY
Color Connects With
White/Blue Emergency NeutralBlue Emergency LineBlack Utility line (Unswitched Hot)White Utility NeutralRed Switched Hot
CASE 7: DTS WITH INDIVIDUAL FIXTURE LVR OR LVS SENSOR
DTS Dimming Bypass ModuleWIRING DIAGRAMS
© 2019 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd • Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
Page 9/9 Rev. 08/21/19COL-DTS-IMP
Integration Guide
CASE 10: DTS/NXFM-0/I WITH FLEX
KEY
Color Connects With
Violet Emergency NeutralGray Emergency LineBlack Utility line (Unswitched Hot)White Utility NeutralGreen Ground
CASE 9: DTS WITH FLEX
DRIVER
WHITE
WHITEBLACK
REDBLUE
GRAY
ORANGE
VIOLET
SMALL YELLOW (CAPPED)
TO LED BOARD(S)
WHITE/BLUE
YELLOW
BLUE
BLACK
WHITE/BLUE
TO EMERGENCY
NXFM-O
RED
REDWHITE
BLACK
FERRITE CHOKE
1 LOOPOF WHT & BLK WIRE AROUND CHOKE
TO UTILITY
TO EMERGENCY
VIOLET
5-WIRE
F LEX
GREEN
VIOLET
WHITE
BLACK
GRAY
GND
GROUND TO HOUSING
6- WIRE FLEX KEY
Color Connects With
Black Utility Line (Unswitched Hot)White Utility NeutralRed Switched HotViolet DimmingGray DimmingGreen Ground
3-WIRE FLEX KEY
Color Connects With
White Emergency NeutralBlack Emergency LineGreen Ground
DRIVER
WHITE
WHITEBLACK
RED
REDBLUE
GRAYVIOLET
VIOLET
ORANGE
SMALL YELLOW (CAPPED)
TO LED BOARD(S)
TO UTILITY
WHITE/BLUE
YELLOW
BLUE
WHITE/BLUE
BLACK
6-WIRE
FL EX
3-WIRE
FL EX
BLAC
KW
HITE
GND
TO EMERGENCY
GRAYVIOLET
BLACK REDWHITE
GND
GND
GROUND TO HOUSING
top related